ILCS EDGE Jr EDP Installation Manual

Similar documents
ILCS EDGE System Installation Manual

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

On-Premise Pro Instruction Manual

Table of Contents. Introduction. KP1H Components... 2 Installation and Assembly

OP-500 On-Premise Series Instruction Manual

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

SOLUTION STATION Instruction Manual

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

Intended Use: Explanation of Signal Word Consequences

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

Reference Manual FM-200 Series

BIOACTIVE SOLUTIONS AC DRAIN STATION

FRS Dispenser (Foam-Rinse-Sanitize) Model # ol Systems. Dilution Control OPERATION SERVICE PARTS CARE

Trident Laundry Chemical Delivery System

SAFETY INFORMATION & INSTRUCTION MANUAL

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

I Button Chemical Dispenser. Overview. Installation Instructions

Items # and #

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

DEMAMaster TM DM-811 Series Installation Manual

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

On-Premise Plus Instruction Manual

Dilution Control Systems. Multi-Task Dispenser Model #421700PL OPERATION SERVICE PARTS CARE. Dema #i GAPDB-MC2

Certo Chemical Dilution System

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

EBS PRODUCTS

PeroxiDraw Dispenser

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

G8 Portable Fuel Transfer Pump Owner s Manual

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA SQUIRT DRAIN UNIT

Spray & Foam Dispenser Item #

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

665 Series Dispenser. Metering tip kit

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

SPLASH-N-DASH. Coleman Hanna Carwash Systems. World Class Manufacturing in Car Wash Equipment. Splash-N-Dash Installation/Operation Manual

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

Spray Clean 606T-2 Installation Instruction

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

EBS PRODUCTS

Owner's Manual GROUNDHOG JETTER

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

VEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

DEMA Pro-Fill I Sink Dispenser

PARTS AND INSTALLATION MANUAL

Installation Instructions

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

ProFlo FatBoy

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

CRD600 Automatic Fitting Inserter

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

DEMA Pro-Fill II Sink Dispenser

Installation and Maintenance Manual

Multi-Tank Submersible Pump Install Manual

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

MODEL 1385 & 1385-H Professional Rotary Drum Pump

Installation Instructions / Warranty. Starck Semi-Pro

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

Owner s Manual SMT PORTABLE SERIES IMPORTANT DOCUMENT - DO NOT DISCARD 600PE 1100PE 1100HC. SprayMasterTech.com. Date Manufactured: / / 600PE 1100PE

Installation Instructions

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

EQUIPMENT OWNERS MANUAL MATTHIESEN HEAVY DUTY SHAKER

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Dilution Control Systems. 2-Button Station Model OPERATION SERVICE PARTS CARE

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

CRD610 Automatic Fitting Inserter

Installation and Operation Manual

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

BUG PREP KIT 2.0 HAND-PREP SYSTEM. User Manual REV A reva0616

Transcription:

ILCS EDGE Jr EDP Installation Manual 0900933 Rev: REL (05/09) Page 1 of 8

TABLE OF CONTENTS System Overview...3 System Components...3 Pre-Installation...4 Control Box & Power Supply Installation...4 Pump Cabinet Installation...4 Label Change Procedure...5 Control Box Diagram...5 Pump Cabinet Diagram...6 Flush Manifold Diagram...6 Wiring Diagram...7 Warranty Information...8 Knight Locations...8 CAUTION: Wear protective clothing and eyewear when dispensing chemicals or other materials. Observe safety handling instructions (MSDS) of chemical mfrs. CAUTION: To avoid severe or fatal shock, always disconnect main power when servicing the unit. CAUTION: When installing any equipment, ensure that all national and local safety, electrical, and plumbing codes are met. Page 2 of 8 0900933 Rev: REL (05/09)

SYSTEM OVERVIEW The ILCS EDGE Jr (Intelligent Liquid Control System) is an automated chemical control system that accumulates critical usage data of chemicals used for cleaning in food plants. Using the very latest concepts in process control technology, the ILCS EDGE Jr provides key benefits: Ease of Operation: ILCS EDGE Jr eliminates messy drum pumps and the need to lift heavy drums of chemical that can splash hazardous chemicals or spill on the ground. Pre-determined formulas can be dispensed into a gerry can or other container. Cost Control: ILCS EDGE Jr does more than just dispense chemicals. It gives all users the opportunity to get real control of every aspect of day-to-day operation. Safety: The system limits the worker from coming in contact with concentrated cleaners by automatically dispensing products into standard containers to use throughout the food plant. Environmental Safety: By dispensing directly to a product container the system limits spillage or waste. Chemical concentrations and volumes are computer controlled to eliminate waste and guarantee the exact amount of product used for each cleaning process. Main Control: The ILCS EDGE Jr control panel allows direct programming of the system at the keypad, and also stores report information. PC interface to the control panel expands the data management capabilities. SYSTEM COMPONENTS See the diagram on the following page for identification of the system components listed below. (A) Power Supply: Isolates high voltage system operating power from the control box. The power supply box contains a transformer and electrical noise filter for added protection. (B) Control Box: Contains all system electronics and is the main command center for operation. The keypad allows programming of all system operating parameters and entry of access codes for batch dispensing. The system can also be equipped with an optional proximity card reader for convenient and secure access code entry. (C) Pump Cabinet: EDP pumps are available in 1.5 GPM and 3.2 GPM flow rates. Also housed inside the control box are the optional flush manifolds and water flush valves (used for diluting and blending chemicals with water). The system has two separate water flush solenoids and dual manifolds to prevent cross-contamination of noncompatible chemicals. A B C 0900933 Rev: REL (05/09) Page 3 of 8

PRE-INSTALLATION Before the equipment is installed, you should survey the installation site thoroughly. Listed below are some of the factors to consider when picking your location. Work Area the unit should be mounted in a centralized area to work areas. Chemical location unit should be mounted close to the chemical tanks. Mounting surface ensure there is a sturdy wall (or panel) with enough space for all system components and routing of chemical tubes and cables. Electrical requires 115 VAC or 230 VAC power source (depending on model) 20 amp service recommended. Water Service system requires ambient water service to flush manifold (if so equipped). Recommended minimum 25 PSI flow pressure. Familiarize yourself with all applicable safety, electrical, and plumbing codes. CONTROL BOX & POWER SUPPLY INSTALLATION (1) Mount the joggle bracket to the wall at a height that all users can access and read the display screen. Use the hardware in the accy kit or other appropriate hardware for the mounting surface. (2) Hang the control box unit on the joggle bracket. Secure the control box to the wall with provided hardware. (3) Mount the power supply box in close proximity to the control box unit. (4) Connect main power from a suitable breaker to the power input terminal block inside the power supply box, and per local wiring codes. (5) Connect power from the power supply box to the appropriate terminals on the main control board inside the control box using the cable provided (see wiring diagram for details). (6) Connect water supply hardware not provided. Unit has 8-port manifold standard and can be equipped with additional 4-port manifold option. PUMP CABINET INSTALLATION Before installation, choose a mounting location for the chemical pumps that is as close as possible to the chemical containers. (1) Mount the pumps as close as possible to the chemical supply and no more than 10 ft above the chemical containers. (2) Connect braided tubing between the barb fitting on the suction (right) side of the pump and the barb fitting on the chemical pickup tube. Use stainless steel hose clamps to secure the tubing to the fittings. (3) Install braided tubing between the barb fitting on the discharge (left) side of the pump and the corresponding port on the manifold. Use stainless steel hose clamps to secure the tubing to the fittings. (4) Insert pickup line into appropriate chemical container. (5) Prime all chemical pumps. This can be done with manual prime buttons on the POB board or the control panel of the ILCS EDGE Jr system. Page 4 of 8 0900933 Rev: REL (05/09)

LABEL CHANGE PROCEDURE (1) Shut off power to the system. (2) Remove screws that hold the LFP circuit board to the front panel of the control box. (3) Disconnect ribbon cable from the LFP circuit board. (4) Use 2 of the screws to temporarily hold the board onto the front panel while changing the label. (5) Carefully remove old label. Start by prying up on a corner with a sharp edge blade. Use of a heat gun may be helpful to loosen the adhesive. (6) Clean old adhesive from the front panel with alcohol in preparation for adhering the new label. (7) Carefully remove the backing paper from the new label. Route the ribbon cable through the slot in the front panel and adhere the label in place using the keyhole and LFP window for proper alignment. (8) Push out any air bubbles that may have gotten trapped while attaching the new label. Work from the middle region of the label to outer edges. (9) Remove the 2 screws that were temporarily holding the LFP circuit board in place and attach the ribbon cable. (10) Re-attach the LFP circuit board back on the front panel using all mounting screws. (11) Turn power to system back on. (12) Test each button of the new label to ensure proper function. CONTROL BOX DIAGRAM 0900933 Rev: REL (05/09) Page 5 of 8

PUMP CABINET DIAGRAM FLUSH MANIFOLD DIAGRAM Page 6 of 8 0900933 Rev: REL (05/09)

SYSTEM WIRING DIAGRAM 0900933 Rev: REL (05/09) Page 7 of 8

DISCLAIMER Knight LLC does not accept responsibility for the mishandling, misuse, or non-performance of the described items when used for purposes other than those specified in the instructions. For hazardous materials information consult label, MSDS, or Knight LLC. Knight products are not for use in potentially explosive environments. Any use of our equipment in such an environment is at the risk of the user, Knight does not accept any liability in such circumstances. WARRANTY All Knight controls and pump systems are warranted against defects in material and workmanship for a period of ONE year. All electronic control boards have a TWO year warranty. Warranty applies only to the replacement or repair of such parts when returned to factory with a Knight Return Authorization (KRA) number, freight prepaid, and found to be defective upon factory authorized inspection. Bearings and pump seals or rubber and synthetic rubber parts such as O rings, diaphragms, squeeze tubing, and gaskets are considered expendable and are not covered under warranty. Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equipment. Product abuse or misuse voids warranty. FOOTNOTE The information and specifications included in this publication were in effect at the time of approval for printing. Knight, LLC reserves the right, however, to discontinue or change specifications or design at any time without notice and without incurring any obligation whatsoever. Knight Headquarters Tel: 949.595.4800 Fax: 949.595.4801 USA Toll Free Tel: 800.854.3764 Fax: 800.752.9518 KNIGHT LLC, A Unit of IDEX Corporation (www.knightequip.com) Knight Canada Tel: 905.542.2333 Fax: 905.542.1536 Knight Europe Tel: 44.1293.615.570 Fax: 44.1293.615.585 Knight Australia Tel: 61.2.9725.2588 Fax: 61.2.9725.2025 Knight N. Asia Tel: 82.2.3481.6683 Fax: 82.2.3482.5742 Knight S. Asia Tel: 65.6763.6633 Fax: 65.6764.4020 Page 8 of 8 0900933 Rev: REL (05/09)