S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Similar documents
Matala. VersiFlow Series. Instruction and Maintenance Manual

ESE Series Cast Iron Sewage Pumps

GeyserMax-Flow Series

StormPro BA Series Sump Pump

StormPro BCV400 Sewage Ejector Pump

Owner s Manual Drill and Light Weight Portable Utility Pumps

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

SUBMERSIBLE SUMP PUMPS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PRE-PLUMBED SEWAGE SYSTEM

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Ion Technologies WC33 Submersible Sump Pump

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Your Premier Pump Choice!

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

EBARA Fluid Handling

SUBMERSIBLE PUMP HSE RANGE

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SHEF30 Submersible Sump/ Effluent Pump

GARDEN HOSE UTILITY PUMP

SP40 Submersible Sewage Ejector Pump

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

SUBMERSIBLE PUMP HSE RANGE

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

SUNC3000 / Item #40885

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

PUMP VAULT S.T.E.P. SYSTEM

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

SUBMERSIBLE SEWAGE PUMPS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Submersible Effluent Pump

Installation Manual DIAPHRAGM WELL TANK

HALLMARK INDUSTRIES INC

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Installation Operation Parts

MODELS WGL20, WGL20H and WGL20F

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Intelligent Flap Controller

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Installation Manual. Q Series Quadplex Grinder Systems. Contents

2460 / 2472 / Series Simplex Grinder Systems

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Pump Installation and Service Manual HRS Hydromatic Retractable System

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

MODELS 125M/B, 150M/B and 200M/B

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

SHALLOW WELL JET PUMP

MODELS 125M/B, 150M/B and 200M/B

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

Powerful & Intelligent Submersible Pumps

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

SPC-PANEL Simplex, Single Phase Pump Control Panel

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

INSTALLATION & OPERATION MANUAL

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

MODELS HPGF/HPGFH, HPGH/HPGHH

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

STAR STOP SHALLOW WELL JET PUMP

Unilift KP 150, KP 250, KP 350

Safety-TrimTM. Dual axis servo controller. with 2 speed presets

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Installation Manual. Engineered Pump Systems (EPS) Common Components: Manual Contents:

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

Transcription:

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C

WARNING risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Pumps can be installed with ABS, PVC or polyethylene plastic pipe, or galvanized or copper pipe. Proper adapters are required to connect plastic pipe to pump. The discharge is threaded for 1-1/2 inch pipe. NOTE: DO NOT OVERTIGHTEN DISCHARGE PIPE INTO PUMP PLASTIC DISCHARGE FITTING. A CHECK VALVE MUST BE USED IN THE DISCHARGE LINE FOR ALL PUMPS. A shut-off valve should be used. Always install check valve with arrow on body in direction of flow. AIR LOCKING A sump pump is said to be air locked if water traps air in the pump and it cannot get out, thus preventing pump from operating. All Myers sump pumps have a small air vent hole in the impeller chamber to let out trapped air. If this hole becomes plugged, pump may air lock. This usually happens on pumps that are used mainly in the wet seasons. In summer months,the pump may be turned off as sump water dries up. When pump is turned on again and water comes up in the sump, the air will trap in pump if not vented. AS A SECONDARY PRECAUTION IN INSTALLATIONS OF THIS TYPE, EXAMPLE: TYPE A 1/8" HOLE SHOULD BE DRILLED IN THE DISCHARGE PIPE BELOW THE CHECK VALVE. THE CHECK VALVE SHOULD BE 12 TO 18 INCHES ABOVE PUMP DISCHARGE. DO NOT PUT CHECK VALVE DIRECTLY INTO PUMP DISCHARGE OPENING. In normal sumps where the pump is operating daily, air locking rarely occurs. P. 2

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION Failure to follow these instructions may cause serious bodily injury and/or property damage. Warranty void if product modified, drilled, painted, or altered in any way; if used to pump hot water, or to pump liquids other than water (such as but not limited to chemicals, fertilizers, flammable liquids, herbicides, mud, tar, cement, wood chips); or otherwise abused. WARNING, risk of electric shock This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. This pump has not been investigated for use in swimming pool areas. DO NOT WORK ON PUMP UNTIL POWER IS UNPLUGGED. DO NOT cut off ground pin or use an adapter fitting. DO NOT use an extension cord. The pump power cord should be connected to a separately fused, grounded 115 volt line with a capacity of 15 amps. NEVER touch the pump when it is connected to electrical power. 1. Before installing or servicing your pump, BE CERTAIN pump power source is disconnected. 2. Installation and electrical wiring must adhere to state and local codes and must be complete before priming pump. Check appropriate community agencies, or contact local electrical and pump professionals. 3. CALL AN ELECTRICIAN WHEN IN DOUBT. Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse block. Plugging into existing outlets may cause low voltage at motor, causing blown fuses, tripping of motor overload, or burned out motor. 4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory. Myers sump pumps come with a grounding conductor and a groundingtype attachment plug. Do not connect pump to a power supply until permanently grounded. For maximum safety, ground pump to a circuit equipped with a fault interrupter device. PERFORMANCE TABLE (in gallons per minute) PUMP MODEL S33 TOTAL HEAD (vertical pumping distance) IN FEET 6 8 10 12 14 16 18 20 22 22 33 30 29 27 25 23 17 15 12 2 5. Voltage of power supply must match the voltage of the pump. All Myers sump pumps are factory preset to 115V, 60Hz. 6. Before installing pump, clear sump basin of any water, debris, or sediment. WARNING: Sump basin must be vented in accordance with local plumbing codes. Myers sump pumps are not designed for and CANNOT be installed in locations classified as hazardous in the National Electric Code, ANSI/NFPA 70. 7. The sump basin should be between 14" and 18" in diameter for the S33A1, S33P-1, S33A1C, S33PC-1, S33M1C and 12" 18" for the S33V1, S33V1C, S33PV1 made of plastic, fiberglass, or concrete. 8. The following may cause severe damage to pump and will void warranty: Using the pump without a check valve. Using an extension cord. Cutting off the ground pin or using an adapter fitting. Working on pump or switch while plugged in. Removing motor housing, unscrewing impeller, or otherwise removing impeller seal. Running the pump continuously. Pumping chemicals or corrosive liquids. Pumping gasoline or other flammable liquids. PIPING Plastic PVC pipe is shown in the illustrations, but drain hose, galvanized steel or copper pipe may be used if desired. All piping must be clean and free of all foreign matter to prevent clogging. Use thread compound on all threaded joints unless specified otherwise. 9. Do not open pump housing to attempt repair this will cause a severe shock hazard. 10. Any finished basement or living area should be equipped with a sump pump alarm to warn of a pump failure and protect against water damage. 11. Cycle the pump at least once per month when regular use isn t occurring. 12. Always use a properly installed check valve with this sump pump. A CHECK VALVE MUST BE USED IN THE DISCHARGE LINE FOR ALL PUMPS. A shut-off valve should be used. Always install check valve with arrow on body in direction of flow. PUMP MOTOR NEVER REMOVE MOTOR HOUSING OR UNSCREW PUMP IMPELLER. Warranty on pump is void if motor housing, impeller or seal have been removed. Any repair on motor must be done by an authorized Myers service center. 23833A587 P. 3 Bag #18812A108

COMPLETE SUBMERSIBLE SUMP PUMP INSTALLATION Refer to the installation illustrations below and on the following page for the following instructions. Be certain sump basin is clean and all power to pump is shut off. If pump fails to operate properly after installation, refer to the troubleshooting checklist on page 6 or contact your Myers distributor. All parts with part numbers are quality Myers parts. Tools Needed for All Pump Installation Pipe wrench, slot screwdriver, hacksaw, round file, drill, 1/8" drill bit, pvc cement. 1 Thread male PVC adapter into pump discharge opening. 3-5/8" Minimum or 2 Cement a 15" piece of PVC pipe to adapter. Use appropriate diameter piping. Drill a 1/8" relief hole in the pipe 5" above pump connection. This hole prevents pump from air-locking. Retrofit 5" 3 Clamp Check Valve to top of 15" PVC pipe with water flow arrow pointing away from pump. 4 Lower pump into basin. Clamp needed PVC discharge pipe and fittings to open end of Check Valve. 5 Fill sump basin with water and plug in pump. Perform several ON-OFF cycles to assure satisfactory operation. P. 4

STARTING PUMP - S33A (AUTOMATIC) 1. These pumps have an integral mechanical (mercury-free) ball float switch as shown on installation drawing. Vertical switch models have a vertical actuated cylinder float. 2. Plug cord into a 115 volt GROUNDED RECEPTACLE. 3. Run water into sump until pump starts. 4. Allow pump to operate through several on-off cycles to be sure operation is satisfactory. 5. If shut-off valve is used in discharge line, be sure valve is open. 6. If pump does not operate properly, see trouble service chart for remedy. NOTE: TETHER LENGTH OF SWITCH CORD ON BALL FLOAT MUST BE MINIMUM OF 3-5/8" AS NOTED IN INSTALLATION 1, PAGE 4. USING THE S33M SUMP PUMP FOR MANUAL OPERATION The pump cord for these units can be plugged directly into proper GROUNDED RECEPTACLE for continuous pump operation. CAUTION: THIS TYPE OF OPERATION SHOULD BE USED ONLY FOR EMERGENCY USE OR WHERE A LARGE VOLUME OF WATER IS TO BE PUMPED, SUCH AS FLOODED BASEMENT. PUMP MUST NOT BE RUN CONTINUOUSLY OUT OF WATER. NOTE: RUNNING PUMP CONTINUOUSLY WILL VOID WARRANTY. DO NOT USE WITH EXTENSION CORD. AUTOMATIC/MANUAL MODEL The Model S33 sump pump can be changed from one style, Automatic or Manual, to the other by interchanging only the plug ends of the float control with the manual plug. The ball floats must be tethered with a cable clamp, as shown. DO NOT REMOVE THE MOTOR CAP. HOW MECHANICAL SWITCH FLOAT OPERATES This level control uses a mechanical switch sealed in a polypropylene float cylinder. The switch is not position sensitive; that is, it will operate regardless of position. When level rises in the sump, the cylinder floats up with the level. When the cylinder position is at an angle of about 45º, the steel ball rolls over a detent and actuates the switch. This starts the pump motor. As the sump level draws down, the cylinder floats down and when it is again at an angle of about 45º, the steel ball drops away, deactivating the switch and the motor stops. BE SURE CYLINDER FLOATS FREELY IN SUMP BASIN WITHOUT TOUCHING THE BASIN WALLS. ADJUST PUMP POSITION IN SUMP IF NECESSARY. PUMP MOTOR NEVER REMOVE MOTOR HOUSING OR UNSCREW PUMP IMPELLER. Warranty on pump is void if motor housing, impeller or seal have been removed. Any repair on motor must be done by an authorized Myers service center. MAINTENANCE AND SERVICE If pump does not operate properly, follow steps shown on servicing chart. If trouble cannot be located with these steps shown, call Myers service dealer, or take pump to Myers authorized service center. CAUTION: FOR ANY WORK ON PUMP OR SWITCH, ALWAYS UNPLUG POWER CORD. CLEANING FLOAT If pump becomes inoperative because of accumulation of trash on the float, remove from sump and clean float. 1. Wipe all water and dirt from pump and float and also the vertical rod on vertical models. 2. Be sure float operates freely after cleaning. CLEANING IMPELLER AND VOLUTE CASE 1. Remove (3) screws that hold bottom plate to volute case. 2. Remove (4) screws that hold volute case to metal motor housing. 3. Use screwdriver to pry plastic case from metal housing. Use care not to gouge groove in the plastic. Pry in several spots to loosen. 4. Remove volute case and clean impeller and volute passage. 5. Be sure impeller turns freely after cleaning. 6. Clean out holes in plastic pump base and wash thoroughly before replacing. 7. DO NOT UNSCREW IMPELLER. 23833A587 P. 5 Bag #18812A108

Service Chart SYMPTOMS SOLUTIONS Pump does not run or hum. X X X X X X Pump runs but does not deliver water. X X X X X X Pump runs and pumps out sump but does not stop. Line circuit breaker may be off, or fuse, if used, may be blown or loose. Water level in sump may be too low. Run in more water. Turn-on level is 12 to 13 inches above sump bottom. Pump runs but delivers only small amount of water. X X X X Pump cord plug may not be making contact in receptacle. If pump is using the series cord plug, the two plugs may not be plugged tight together. Fuse blows or circuit breaker trips when pump starts. X X X X Motor runs for short time then stops. Then after short period starts again. Indicates tripping overload X X X caused by symptom shown. For any other symptoms call Myers Service Dealer. Check tether length of switch per directions. Float may be stuck. Be sure float operates freely in basin. If all symptoms check OK, motor winding may be open. Take to service center for check. Check valve may be installed backward. Arrow on valve points in direction of flow. Discharge shut-off valve, if used, may be closed. Pump may be air locked. Start and stop several times by plugging and unplugging cord. Check vent hole in pump case for plugging. Pump head may be too high. Pump cannot deliver water over 18 ft. vertical. Horizontal distance does not affect pumping, except loss due to friction. Inlet holes in pump base may be clogged. Remove pump and clean out openings. Impeller or volute openings may be plugged or partially plugged. Remove pump and clean per maintenance instructions. Float is stuck in up position. Be sure float operates freely in basin. X Fuse size or circuit breaker is too small. Must be 15 amps. Defective motor stator; return to Myers service center. P. 6

MYERS LIMITED WARRANTY SUMP & RESIDENTIAL SEWAGE During the time periods and subject to the conditions hereinafter set forth, F.E. Myers will repair or replace to the original user or consumer any portion of your new MYERS product which proves defective due to defective materials or workmanship of MYERS. Contact your nearest Authorized MYERS Dealer for warranty service. At all times MYERS shall have and possess the sole right and option to determine whether to repair or replace defective equipment, parts, or components. Damage due to lightning or conditions beyond the control of MYERS is NOT COVERED BY THIS WARRANTY. WARRANTY PERIOD Pumps: 12 Months from date of purchase or 18 months from date of manufacture. Labor, etc. Costs: MYERS shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and/or reaffixing any MYERS product, part or component thereof. THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and the parts used in connection with such service; (d) to units which are not installed in accordance with applicable codes, ordinances and good trade practices; or (e) unit is used for purposes other than for what it was designed and manufactured; and (f) if three phase submersible motors are installed on a single phase power supply using a phase converter or if three phase power is supplied by only two transformers, making an open Delta system. RETURN OR REPLACEMENT COMPONENTS: any item to be replaced under this Warranty must be returned to MYERS in Ashland, Ohio, or such other places MYERS may designate, freight prepaid. PRODUCT IMPROVEMENTS: MYERS reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and/or shipped prior to such change or improvement. WARRANTY EXCLUSIONS: MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AFTER THE TERMINATION OF THE WARRANTY PERIOD SET FORTH HEREIN. Some states do not permit some or all of the above warranty limitations and, therefore, such limitations may not apply to you. No warranties or representations at any time made by any representatives of Myers shall vary or expand the provision hereof. LIABILITY LIMITATION: IN NO EVENT SHALL MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION MYERS RECOMMENDS FOLLOWING THE INSTRUCTIONS IN THE INSTALLATION MANUAL. WHEN IN DOUBT, CONSULT A PROFESSIONAL. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights and you may also have other rights which vary from state to state. In the absence of suitable proof of this purchase date, the effective date of this warranty will be based upon the date of manufacture. DETERMINATION OF UNIT DATE OF MANUFACTURE: Submersible sump pump (8-95) month and year stamped on nameplate; column sump pump month and year on red warranty tag. F.E. Myers, 1101 Myers Parkway, Ashland, Ohio 44805 419-289-1144 FAX: 419-289-6658 www.femyers.com 23833A587 P. 7 Bag #18812A108