We have achieved Miniaturization and Low Power -port valves for high value-added new generation New Valve for the New Century Thin and compact Valve w

Similar documents
SOLENOID VALVES SERIES

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves)

SOLENOID VALVES. HEB series SOLENOID VALVES EA, EB SERIES. (2, 3-port pilot type solenoid valves) 53mm. 10mm

Solenoid Valves JC, JE Series

SOLENOID VALVES, SERIES

SOLENOID VALVES INDEX VALVES GENERAL CATALOG SERIES

SOLENOID VALVES SERIES

Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

SOLENOID VALVES JC JE SERIES INSTRUCTION MANUAL

SOLENOID VALVES, SERIES

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

SOLENOID VALVES, SERIES

SOLENOID VALVES 010 SERIES INSTRUCTION MANUAL

SOLENOID VALVES SERIES

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS

Micro 3-port Solenoid Valve 005 Series

The first in the world!

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS

ACTUATORS GENERAL CATALOG

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders

The first in the world!

ACTUATORS GENERAL CATALOG

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES

MICRO EJECTORS CONTENTS

BKUA002 Ver.1.0. Vacuum MICRO EJECTOR. INSTRUCTION MANUAL Ver.1.0

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

MULTI SLIDERS CONTENTS

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

SOLENOID VALVES SERIES

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Air Valve AIR-PILOTED VALVES

SLIDE TABLES CONTENTS

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

Specifications. Fluid Ambient and fluid temperature ( C)

Series VQ Port Solenoid Valve

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

3 Port Solenoid Valve

3 Port Solenoid Valve

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Free position locking flat and compact cylinder UFCD Series

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL

Soft Start-up Valve. AV2000/3000/4000/5000 Series

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

Compact direct acting precision regulator

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Installation Manual For ISL98, ISL03, ISL07, ISC07

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

TUBES CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBES

A/C COMPRESSOR SERVICING Article Text 1991 Saab 9000 For Copyright 1997 Mitchell International Friday, October 15, :22PM

ACTIVAL Two-way Ball Valve with Threaded-end Connection

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Series AV2000/3000/4000/5000

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Maintenance Manual 3-INCH INTERNAL VALVE F660 SERIES

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Maintenance Manual. 3-Inch Internal Valve. F660 Series

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series SYJ300/500/700

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

SPEED CONTROLLERS WITH QUICK FITTINGS

SG-B1 SERIES / SG-A1 SERIES

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

Series. High-speed valve. K2 Series 2-port valves. K3/K4 series. High-speed response 0.4 to 3.0 ms (ON)

Tooling Assistance Center

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Model INTERNAL/BOTTOM LOADING VALVES SM Maintenance & Repair Manual. July Applicable addition manuals: None

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Pilot Operated 2 Port Solenoid Valve for Dry Air

Maintenance & Repair Manual

Maintenance Information

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

CVE2/CVSE2 CVE3/CVSE3

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Door Interlock Switches

Compact Proportional Solenoid Valve

CHAS FRONT FORK FRONT FORK LEGS 4-45 FRONT FORK. Order Job/Part Q ty Remarks

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

11.Preparation for Overhaul

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Purging Air From Divider Block Lubrication Systems

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

HS6B Series Subminiature Interlock Switch

MAGNET TYPE RODLESS CYLINDERS SERIES CONTENTS

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

EISHO TEK. Vacuum Circuit Breaker

HS5E Miniature Interlock Switches with Solenoid

Seven Features of the Koganei Vacuum Valve

Transcription:

Catalog HJA- Series Solenoid Valves Options are increased. Compact Body & Wire Saving!

We have achieved Miniaturization and Low Power -port valves for high value-added new generation New Valve for the New Century Thin and compact Valve width of only 0.5 mm [0.in.] achieves a thin and compact size valve, enabling space saving in equipment design. Effective area :.5mm (Cv: 0.9) Suitable for operating up to0 [ /in.] bore size cylinders. Manifold height 50mm [in.] Wide Product Range Select from a choice of five types for customer s applications. Sub-base Series Solenoid Valves Low power consumption Standard: 0.5W (ma at DCV, ma at DCV) Low current type: 0.5W (0.5mA current at DCV) Note Note: Using power saving circuit (Starting current is ma.) Minus common is available Plus or minus common is selectable on connector side using the same valve type. (Excluding serial transmission type) Photo shows split type manifold plugin type with flat cable and 0-pin connector with built-in muffler on exhaust port in the piping block. Monoblock Manifold Type Split Manifold Non-Plug-in Type Split Manifold Plug-in Type Serial Transmission Type

Consumption as well as the addition of Tandem valves. Tandem -port -position valve Two -port valve functions in one valve body. The same port valve operation with half the number of the current valves. Two -port valves can be operated independently in the same valve. valve types are available. HJA0AANormally closed & Normally closed type HJA0ABNormally open & Normally open type HJA0ACNormally closed & Normally open type The same valve operation is possible as -position valve. HJA0AA works as ABR connection valve HJA0AB works as PAB connection valve Wire saving is possible Common terminal prewired plug connector Caution Always read the Safety Precautions on page before use. Flat cable connector on top surface Note Flat cable connector on side surface Note D-sub connector on top surface Note D-sub connector on side surface Note Serial transmission type Note: Connector mounting direction can be changed. But in the -D70U, D-sub connector on top surface is only available. Model (A) side With 5/6 tube quick fitting type With / tube quick fitting type With /8 tube quick fitting type (B) side Normally Normally HJA0AA closed closed (NC) (NC) Normally Normally HJA0AB open open (NO) (NO) Normally Normally HJA0AC closed open (NC) (NO) Symbol Built-in muffler type Common terminal pre-wired type (available for monoblock manifold and split manifold non-plug-in type) Flat cable connector and D-sub connector (available for split manifold plug-in type) Conforming to serial transmission (Conforming to CC-Link, DeviceNet and CompoBus/S) Back pressure preventive valve installed (optional) This prevents incorrect operation occuring from back pressure, in such as single acting cylinder applications. Individual air supply spacer (optional) By installing dedicated air supply spacer between the manifold and the valve, individual air supply is possible. Individual air supply spacer (M5) Back pressure preventive valve Supply or exhaust piping block You can select either quick fitting type or built-in muffler type for exhaust port except for monoblock type manifold. INDEX Safety Precautions Handling Instructions and Precautions Disassembly Diagram of Split Manifold 8 Detailed Diagram of Wiring Block Internal Connections Serial Transmission Block Specifications Operating Principle and Symbol Order Code 6 Pin Locations by Wiring Specification Pin No. and Corresponding Solenoid 5 Specifications Dimensions of Single Valve Unit Dimensions of Monoblock Manifold 6 Dimensions of Split Manifold Non-Plug-in Type 7 Dimensions of Split Manifold Plug-in Type 8 Dimensions of Serial Transmission Type 55

Safety Precautions (HJA Series Solenoid Valves) Always read these precautions carefully before use. Mounting General precautions. While any mounting direction can be allowed, avoid directly applying shocks or vibrations on the valves.. Avoid using in the locations and environments listed below because they could result in valve breakdowns. If you must use in such conditions, always provide a cover and take other adequate protective measures. Locations where the valve is directly subjected to dripping water or oil, etc. Environments where moisture condenses on the valve body. Locations where the valve is directly subjected to metal chips or dust.. Always thoroughly blow off (use compressed air) the piping before connecting it to the valve. Entering chips, sealing tape, rust, etc., generated during piping work could result in air leaks or other defective operation.. The valve cannot be used with the (A) and (B) ports left open. 5. If mounting the valve inside a control panel, or if energizing it for long periods of time, provide air ventilation or other methods to effectively radiate the heat. Media. Use air for the media. For the use of any other media, consult with Humphrey.. Use clean air that does not contain deteriorated compressor oil or other contaminants. Install an air filter (with filtration of 0m or less) close to the valve to catch any airline condensate or dust. Moreover, clean the air filter at regular intervals.. When the supplied pressure is low, use piping with a sufficiently large diameter for the (P) port tube. Lubrication While the system can be used without lubrication, if you must use oil for the actuators, etc., use Turbine Oil Class (ISO VG) or an equivalent. Avoid using spindle oil or machine oil. Also be aware that excessive amounts of lubricating oil can result in defective operation. Atmosphere The product cannot be used when the media or the ambient atmosphere contains any of the substances listed below. Organic solvents, phosphoric acid ester-based hydraulic oil, sulfuric acid gas, chlorine gas, or acids, etc. Wiring Upon completion of wiring work, always check to confirm that no wiring misconnection exists. Prevention of erroneous operation in the manifold type Whenever using the manifold type valve, such as operating air cylinder or performing air blow work, defective operation due to errors caused by the exhaust or to inadequate flow rate could occur. Take the countermeasures listed below before starting use of the manifold type.. Erroneous operation due to large exhaust flow rate Cause: When using large bore cylinders or simultaneous operation of a number of cylinders, the pressure of the collected exhaust can cause the exhaust to flow back through the exhaust ports of other solenoid valves, obstructing the operations of other cylinders, or could cause the air in singleacting cylinders or air hands, etc., to flow backward, causing errors in operation. The cause is insufficient exhaust (large exhaust resistance) in the manifold. Countermeasure: To reduce the exhaust resistance in the monoblock manifold, open the exhaust ports on both ends. For the split-type manifold, mount piping blocks on both ends, to exhaust from both sides. If there is still an exhaust interference even exhausting on both ends, either split the manifold, or if already a split-type manifold, attach a split to isolate the exhaust or use the back pressure preventive valve.. Defective operation due to insufficient pressure or flow rate Cause: If using a manifold type for operating a large bore cylinder or simultaneous operation of multiple cylinders, or for circuits for blowing air, etc., sudden large consumption of air could result in insufficient flow into the neighboring cylinder, causing a drop in speed or a shortage of cylinder thrust. Moreover, in the pilot type valve, insufficient pressure for the pilot signal can lead to erroneous operation of the stem. Countermeasure: To prevent air supply shortage to the manifold, supply air from the both ends of the manifold, or from P ports on the piping block mounted on both sides. For air blowing, either separate the air lines and use individually, or consider using an external pilot valve.

Handling Instructions and Precautions Internal circuit Solenoid Plus commondcv, DCV Single solenoid Inside connector Lead wire Lead wire Double solenoid Inside connector Lead wire Black Lead wire Lead wire White Single solenoid Inside connector Lead wire Red Lead wire Black Cautions:. Do not apply megger between the pins.. Leakage current inside the circuit could result in failure of the solenoid valve to return to the rest position or in other erratic operation. Always use at less than the allowable leakage current shown in the solenoid specifications on p.. If circuit conditions, etc., cause the leakage current to exceed the maximum allowable leakage current, consult us.. For the double solenoid specification, avoid energizing both solenoids simultaneously. (Excluding the tandem -port valve). The standard housing type is colored blue, while the low current type is light blue. 5. The low current type will not activate if the power supply voltage is raised slowly. Always apply the appropriate voltage. Operating principles of low current type The low current type uses a timer circuit, as shown in the above, that achieves power savings by switching to holding operations mode after a certain period of time to operate at about / of the start-up power consumption. Power cycle Red Timer circuit Red Red Green Low current typedcv Double solenoid Inside connector Lead wire Black Red Timer circuit Lead wire Red Lead wire White Green Solenoid valves Power consumption Timer circuit Minus commondcv, DCV Single solenoid Inside connector Lead wire Red Lead wire Black Double solenoid Inside connector Lead wire Red Lead wire Black Lead wire White Single solenoid Red Red Green Low current typedcv Inside connector Lead wire Red Lead wire Black Red Double solenoid Inside connector Lead wire Red Lead wire Black Lead wire White Red Green Timer circuit Timer circuit Timer circuit Wiring instructions (When using as a single unit or non-plug-in type manifold). Attaching and removing plug connector Pick up connector with fingers to insert it into the pin, push in until the lever claw catches the convex section on the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the convex section on the housing, and pull out.. Attaching and removing plug connector and contact Attaching Insert the contact with a lead wire into a plug connector hole until the contact hook catches and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. (See below) Removing To remove, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook of the contact, and then pull out the lead wire. When re-using the contacts, restore the hook back so that they spread outward. Hook Contact Housing Convex section Pin Lead wire. Common terminal and short bar Plug connector Plug connector Contact Lead wire Indication of polaritydc Lever Caution: When removing the connector, confirm that the lever claw is completely disengaged from the convex section before pulling out. The housing may be damaged if it is pulled out while engaging with the convex section. A short bar is attached to the plug connector to ensure that the solenoid A and B wiring become plus common or minus common. Do not remove the short bar. For plus common Short bar Contact (without lead wire) Plug connector (Ivory) For minus common Short bar Contact (without lead wire) Plug connector (Gray) Reduced power consumption Caution: The plug connectors for plus common and minus common differ in shape. Handling Instructions and Precautions Start-up state time

5. Crimping of connecting lead wire and contact To crimp lead wires into contacts, strip off mm [0.6in.] of the insulation from the end of the lead wire, insert into the contact, and crimp it. Be sure to avoid catching the insulation on the expose wire crimping section. Insulation crimp holder Expose wire crimping section Contact Hook Insulation Maximum outer diameter: Expose wire mm [0.6in.] Lead wire Applicable wire Cautions:. Do not pull the lead wire too hard.. Always use the dedicated tool for crimping of connecting lead wire and contact. Contact: Model 706-MK Manufactured by Sumiko Tech, Inc. rimping tool: Model F (For 706-MK) Manufactured by Sumiko Tech, Inc. 5. Common connector assembly for manifold Using common connector assembly for the solenoid valve for manifold provides common wiring for all solenoid valves and greatly reduces wiring work. The common connector types are determined by looking from the lead wire side, the right end one is A type, the left end one is C type, and all others are B type. (See below) For plus common Single solenoid valve Double solenoid valve Common wire Red C type For minus common Single solenoid valve Double solenoid valve Common wire Black C type B type A type B type A type Common wire Red Common wire Red Common wire Black Common wire Black For common connector assembly, order the common connector assemblies listed below. For plus common A type ModelHJAZ-PA B type ModelHJAZ-PB C type ModelHJAZ-PC For minus common A type ModelHJAZ-MA B type ModelHJAZ-MB C type ModelHJAZ-MC Manual override Red : Common wire A side B sideinsert when using as double solenoid Red : Common wire A side B sideinsert when using as double solenoid Red : Common wire A side B sideinsert when using as double solenoid Red : Common wire Lead wire length : 00mm[in.] : 000mm[8in.] : Common wire A side B sideinsert when using as double solenoid : Common wire A side B sideinsert when using as double solenoid : Common wire A side B sideinsert when using as double solenoid : Common wire Lead wire length : 00mm[in.] : 000mm[8in.] Manual override (: Non-locking type, -8: Locking protruding type) To lock the locking protruding type, use a small screwdriver to push down on the manual override all the way and turn it clockwise 90 degrees. When locked, turning the manual override 90 degrees in a counterclockwise direction releases a spring on the manual override, returns it to the original position, and releases the lock. If the manual override is never turned, this type acts just like the non-locking type, like the valve energizing status as long as the manual override is pushed down, and returning to the rest position upon release. SB side manual override (Green) SA side manual override (Pink) Non-locking type PUSH Locking protruding type Cautions:. The HJA series are pilot type solenoid valves. As a result, the manual override cannot switch the main valve without supplying air from the (P) port.. Always release the lock on the locking protruding type manual override before commencing normal operation.. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button.

Split Manifold Installing and removing valves To remove the valve body from the subbase or manifold, loosen the valve mounting screws ( places), and pull valve straight out in the direction of the arrow (see diagram at right). For mounting, conduct the same procedure in reverse. The recommended tightening torque for the valve mounting screw is 7.6Ncm{.8kgfcm} [.56lbfin.]. In the split manifold, inserting splits to the (P), (R), and 5(R) ports between each of the stations isolate the air path between stations equipped with splits and stations with smaller station numbers. Note, however, that a piping block must be placed on both ends. Split for (P) port (Model: HJAZ-S) Split for (R) and 5(R) ports (Model: HJAZ-S) Split for (P), (R) and 5(R) ports (Model: HJAZ-SA) -SSplit for (R) and 5(R) ports Cover Can supply two different pressures. Can isolate exhaust air. (prevents exhaust interference) Can supply two different pressures, and can isolate exhaust air. (prevents exhaust interference) -SSplit for (P) port Caution:Mounting splits requires the disassembly and re-assembly of manifolds. See the disassembly diagram, unit adding procedure, and cautions found on p. 80. Replacement of muffler When using a piping block with built-in muffler, use the following procedure to replace the muffler. (Muffler single unit model: HJAZ-M) q Remove the mounting screws ( screws) holding the cover on top of the piping block. w Remove the muffler to be replaced. e Insert the new muffler so that it reaches the bottom of the groove. r Reinstall the cover, and tighten the mounting screws. Tightening torque: 9Ncm {5kgfcm}[.lbfin.] MufflerHJAZ-M Fitting Replacement of fitting Replacement of output port fitting for split manifold qloosen the mounting screws of the valve for the fitting to be replaced, and remove the valve. wuse a minus screwdriver (blade width mm [0.08in.]) to remove the stopper pin holding the fitting to the valve base from the valve base hook, and pull it out. eremove the fitting to be replaced, and push in and attach the new fitting as far as it will go. rpush in the stopper pin until it hooks onto the valve base. tmount the valve back into place. Note: Ensure that the fitting and the stopper pin mounting in place are firmly tightened. (Fitting single unit model: HJAZ-J/8, HJAZ-J5/, HJAZ-J/ ) Tube Hook Stopper pin Fitting Release ring.attaching and removing tubes For tube connection, insert an appropriate size tube as far as contacting with the tube stopper, and lightly pull it to check the connection. For tube removal, push the tube against the tube stopper, then push the release ring and at the same time pull the tube out..either a nylon tube or urethane tube can be used. Use tubes with an outer diameter tolerance within 0.mm [0.00in.] of the nominal diameter, and allowance of out-of-ellipticity (difference between large diameter and small diameter) is 0.mm [0.008in.] or less. (Using a Koganei tube is recommended.) Cautions:. Do not use extra-soft tubes since their pull-out strength reduces significantly.. Only use tubes without scratch on the outer surface. If scratch is made during repeated use, cut off the scratched section.. Do not bend the tube excessively near the fittings.the minimum bending radius for nylon tubes is as shown in the table below.. When attaching or removing tubes, always stop air supply. In addition, always confirm that air has been completely exhausted from the manifold. Tube size /8 in. 5/ in. 5/6 in. / in. /8 in. mm [in.] Minimum bending radius 0 [0.8] 0 [0.8] 50 [.0] 0 [.] 50 [.0] 6 Handling Instructions and Precautions

7 Precautions for use of back pressure preventive valve Mounting the back pressure preventive valve on the manifold serves to prevent erroneous cylinder operation due to exhaust flowing from other valves. This is particularly effective when using single acting cylinders or ABR connection valves. Note, however, that the effective OUT-EXH area is reduced to.5mm [Cv:0.] when using the back pressure preventive valve. In addition, do not let the manifold's exhaust port throttle the exhaust air, since the back pressure preventive valve allows back pressure leaks. If mounting additional back pressure preventive valve to an existing unit, observe the following items. q Loosen the valve mounting screws holding the back pressure preventive valve, and remove the valve. w For the monoblock manifold, temporarily remove the gasket from between the valve and manifold, insert the back pressure preventive valve into the exhaust port, place the gasket, and then mount the valve. Mounting screw Gasket Back pressure preventive valve For the split type manifold, remove the gasket from between the valve and manifold, insert the back pressure preventive valve into the exhaust port, mount the dedicated gasket provided, and then install the valve. Mounting screw Dedicated gasket Back pressure preventive valve Tightening torque of mounting screw : 7.6Ncm {.8kgfcm} [.56lbfin.] Back pressure preventive valve single unit model: HJAZ-E (for monoblock type), HJAZ-E (for split type) Precautions for use of individual air supply spacer By mounting an individual air supply spacer on the manifold, air supply can be provided individually on the unit. Note that when spacers are used, the effective area is reduced by about 0%. When mounting additional spacers to an existing unit, observe the following items. Mounting method of spacers qloosen the valve mounting screws for the added individual air supply spacer, and remove the valve. winstall the gaskets provided with the individual air supply spacer, use the mounting screws provided to mount the valve on the manifold. (See below) For plug-in type, install also the connector Ass'y provided. Tightening torque of the mounting screw: 7.6Ncm {.8kgfcm} [.56lbfin.] (Individual air supply spacer single unit model: HJAZ-NPM, HJAZ-PPM) (Illustration shows the split manifold plug-in type) Connector Ass y Remark: When attaching fittings to the Individual air supply spacer, use the recommended fittings shown below. TSH-M5M, TSH-M5, TSH6-M5M, TS-M50, TS-M5M Note, however, that only the TSH-M5M can be attached to HJA0A7, A8, and A9 (-position valve). Dimensions mm [in.] For non-plug-in type HJAZ-NPM Changing the direction of the connector bracket Change the connector from an upward facing to a side facing by removing the wiring block mounting screws, setting the connector bracket in the position shown in the diagram, and then turning the connector 90 degree so that it faces to the outside. Tightening torque of mounting screw: 9Ncm {5kgfcm}[.lbfin.] Mounting screw Gasket Individual air supply spacer For plug-in type HJAZ-PPM Connector Ass'y Connector bracket Mounting screw Caution: In the -D70U, direction of the connector cannot be changed, D-sub on top is only available.

HJA Series Disassembly Diagram of Split Manifold Non-Plug-in Type Figure Mounting screw Adding valve base unit End block Piping block assembly Use the valve base assembly for adding units. qloosen the mounting screw on the end block until the end block can slide (see Fig.). wdisconnect the link between the bases of valve base assembly where the new unit is to be added. emount the valve base assembly to be added on the DIN rail shown in Fig.. rpress the bases together from both sides to ensure that there is no gap between them, and then tighten the end block mounting screws, and install the units in place on the DIN rail (see Fig. ). Tightening torque: 7Ncm {5kgfcm} [lbfin.] Note: Confirm that the DIN rail mounting bracket hooks securely hold the DIN rail (see Fig. ). Caution Always cut off the power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. Be careful not to be trapped or lose gaskets. Before supplying air to the manifold, always confirm that the bases are connected and the end block mounting screws are tightened, etc. Supplying air when either of the end blocks does not securely hold the DIN rail could result in air leaks or separate manifold bases. When there are large number of valves simultaneously requiring air to the secondary side, or when there is a large number of valve units, we recommend using two sources of air supply and exhaust (on each side). Note that adding units of the piping block assembly is performed in the same way as adding units of the valve base assembly. Valve base assembly Manifold Unit Adding Procedure (HJA Series Non-Plug-in Type) Figure Figure End block End block Use hooks on both sides to hold the DIN rail in place. First let the hook catch on this side, and then press down on the base to fit it into the DIN rail. Mounting screw 8 Disassembly Diagram of Manifold

HJA Series Disassembly Diagram of Split Manifold Plug-in Type Figure Mounting screw End block Additional position Piping block assembly Plug-in connector Valve base assembly End block Manifold Unit Adding Procedure (HJA Series Plug-in Type) Adding valve base unit Use the valve base assembly for adding units. qloosen the mounting screw on the end block until the end block can slide (see Fig.). wadd units on the side shown in Fig. (with the solenoid on top and the right). Disconnect the link between the bases where the new unit is to be added. emount the valve base assembly to be added on the DIN rail shown in Fig.. rpress the bases together from both sides to ensure that there is no gap between them, and then tighten the end block mounting screws, and install the units in place on the DIN rail (see Fig. ). Tightening torque: 7Ncm {5kgfcm} [lbfin.] Note: Confirm that the DIN rail mounting bracket hooks securely hold the DIN rail (see Fig. ). Figure Figure End block Piping block assembly First let the hook catch on this side, and then press down on the base to fit it into the DIN rail. Mounting screw Use hooks on both sides to hold the DIN rail in place. 9

Wiring Procedure (for plus common) q Pressing down the upper part of the cover, and open the cover. Loosen the mounting screws of the valves next to the valve base assemblies to be added, remove the valves, and remove the plug-in connector (see Fig. ). w End terminal lead wire (short, red wire) is inserted into pin insert section of the plug-in connectors removed in step q (see Fig. 5). (At time of delivery, end terminal lead wire is inserted into the plug-in connectors of the end unit valve.) Remove this end terminal lead wire, and insert it into the insert section (No. ) of the plug-in connector for the valve base assembly to be added. Afterward, insert the common wire (red) of this plug-in connector into the insert section (No.) of the removed plug-in connector. Note: When inserting the lead wire, confirm that the short bar of the plug-in connector s common wire insert section has been inserted. e Install each of the wired plug-in connectors in step w to the valve base, and mount the valve. r Remove the wiring block mounting screws and place them in the position shown in Fig. 7, then connect the lead wire (white) of the added valve base after confirming the pin location (For details, see the detailed diagram of the wiring block internal connections on p.). t Return the connector brackets to their original position, and tighten the wiring block mounting screws in place, then install the cover while watching to ensure that the lead wires are not trapped by the cover. Wiring Procedure (for minus common) q Pressing down the upper part of the cover, and open the cover. Loosen the mounting screws of the valves next to the valve base assemblies to be added, remove the valves, and remove the plug-in connectors (see Fig. ). w End terminal lead wire (short, black wire) is inserted into pin insert section of the plug-in connectors removed in step q (see Fig. 6). (At time of delivery, end terminal lead wire is inserted into the plug-in connectors of the end unit valve.) Remove this end terminal lead wire, and insert it into the insert section (No.) of the plug-in connector for the valve base assembly to be added. Afterward, insert the common wire (black) of this plug-in connector into the insert section (No.) of the removed plug-in connector. Note: When inserting the lead wire, confirm that the short bar of the plug-in connector s common wire insert section has been inserted. e Install each of the wired plug-in connectors in step w to the valve base, and mount the valve. r Remove the wiring block mounting screws and place them in the position shown in Fig. 7, then connect the lead wire (white) of the added valve base after confirming the pin location (For details, see the detailed diagram of the wiring block internal connections on p. ). t Return the connector brackets to their original position, and tighten the wiring block mounting screws in place, then install the cover while watching to ensure that the lead wires are not trapped by the cover. Caution Always cut off the power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. When removing lead wires from the plug-in connector, use an item with a fine tip (such as a small screwdriver) to press lightly on the contact hook from a window on the side of the plug-in connector, and pull out the lead wire. When re-inserting the lead wire to the connector, spread the contact hooks so that they face outward, and then insert into the plug-in connector. At this time, pull lightly on the lead wire to confirm that it is securely inserted. Always connect the end terminal lead wire. (see Figs. 5 and 6) Be careful not to be trapped or lose gaskets. Before supplying air to the manifold, always confirm that the bases are connected, the end block mounting screws are tightened, etc. Supplying air when either of the end blocks do not securely hold the DIN rail could result in air leaks or separate manifold bases. Be aware that the number of valve units that can be added is limited in the manifold, by the wiring specifications and wiring connection type, etc. When there are large number of valves simultaneously requiring air to the secondary side, or when there is a large number of valve units, we recommend using two sources of air supply and exhaust (on each side). Note that adding units of the piping block assembly is performed in the same way as adding units of the valve base assembly. When wiring specification is -D70U and adding units is required, please contact us. Figure Figure 5 For plus common End terminal lead wire (Red) Figure 7 Plug-in connector Pull straight out Common wire (Red) Lead wire (White) Replace the end terminal lead wire. : Always insert end terminal lead wire. : Shows when both A and B are used. Figure 6 For minus common End terminal lead wire (Black) Common wire (Black) Lead wire (White) Replace the end terminal lead wire. Newly added plug-in connector Lead wire (White) Contact Common wire (Red) End terminal lead wire (Short, red wire) Newly added plug-in connector Contact End terminal lead wire (Short, black wire) : Always insert end terminal lead wire. : Shows when both A and B are used. Common wire (Black) Lead wire (White) Note: For the serial transmission type, remove the serial transmission block. Connector bracket Tightening torque of mounting screw:9ncm {5kgfcm} [.lbfin.] Mounting screw See Detailed Diagram of Wiring Block Internal Connections on p.. 0 Disassembly Diagram of Manifold

Detailed Diagram of Wiring Block Internal Connections Flat cable connector 0, 6 pins D-sub connector Unused pin Position with protruding part upward. NC NC 5 9 7 5 NC 6 0 8 6 Connection to power supply terminal'spole Connection to power supply terminal'spole 5 7 9 5 6 8 0 6 Insert so that protruding part engaged. For the position shown in the above illustration, for the upper part, insert the contact facing upward, and for lower part, insert the contact facing downward. Connection to power supply terminal'spole Connection to power supply terminal'spole Insert into the added locations To plug-in connector Serial transmission block Unused pin NC Position with protruding part upward. 0 9 8 7 6 5 0 9 8 7 6 5 Connection to power supply terminal'spole Connection to power supply terminal'spole 8 7 6 5 8 7 6 5 Connection to power To plug-in supply terminal's connector pole Connection to power supply terminal'spole Insert into the added locations To plug-in connector Position with protruding part upward. Unused pin NC NC 5 Note: As shown in the left illustration, remove the connector and then perform the wiring. For -F00 For -F0 For -F60 To plug-in connector Position with protruding part upward. For -D50 For -D5 For -D70U NC 7 6 Unused pin NC 9 7 5 8 6 0 8 6 0 8 6 9 7 5 9 7 5 0 COMFor minus common COMFor plus common 0 8 9 5 0 5 7 9 5 7 9 6 8 0 6 8 0 NC NC Connection to power supply terminal'spole Connection to power supply terminal'spole Unused pin Insert into the added locations To plug-in connector To plug-in connector Note: Serial transmission blocks compatible with 8- point output cannot use pin Nos. 85. Insert so that protruding part engaged. For the position shown in the left illustration, for the upper part, insert the contact facing upward, and for lower part, insert the contact facing downward. Note: As shown in the illustration above, remove the connector and then perform the wiring. To plug-in connector

5 6 O N 5 6 7 8 9 0 O N O N Serial Transmission Block Specifications General Specifications Voltage DCV 0% Operating temperature range 550 C Vibration resistance 9.0m/s {5.0G} (Conforms to JIS C 09) Shock resistance 98.m/s {0.0G} (Conforms to JIS C 09) For details about specifications, see the user s manual.(see below) Serial Transmission Block and Terminal Block (LED) Part Names For OMRON CompoBus/S Transmission block specification: -A (6-point output), -A (8-point output) Dip switch for various settings BS BDH BDL BS PWR COMM ERR LED names Marking State Display color Description PWR COMM ERR Lights up During power supply Green Shut off When power is not supplied Lights up During normal communication Yellow Shut off Communication fault, or standby Lights up Communication fault occurred Red Shut off During normal communication, or standby Remarks For details about CompoBus/S, see the OMRON catalog, user s manual, etc. Number of outputs per block 6 solenoids (transmission block specification: -A) 8 solenoids (transmission block specification: -A) Related materials: User s manual, document No.HV00 For Mitsubishi Electric CC-Link Transmission block specification: -B PW L RUN L ERR. S D R D DA DB DG SLD Dip switch for various settings V FG 0V LED names Marking Description PW Lights up when power is turned on Lights up when normal data is L RUN received from a master station SD Lights up for data sending RD Lights up for data receiving Lights up for transmission error, and shut off for time over. L ERR. Lights up for a station number setting error or transmission speed setting error Remarks For details about CC-Link, see the Mitsubishi Electric catalog, user s manual, etc. Number of outputs per block 6 solenoids (transmission block specification: -B) Since the block occupies one station, if the block is entirely composed of remote I/O stations, a maximum of 6 units can be connected to one master station. Related materials: User s manual, document No.HV0 Application Examples for Serial Transmission Block of General Purpose Products Type If manifolds with flat cable connectors sold previously have F0 wiring specifications (with plus common specifications only), the serial transmission blocks (general purpose type with flat cable of F0) YS5U can be connected to the manifold to convert it into a serial transmission-compatible manifold. Connectable Manifolds Humphrey solenoid valves HJA series Voltage requirements follow DCV specifications. O N 5 6 7 8 9 0 For DeviceNet (OMRON CompoBus/D) Transmission block specification: -D Dip switch for various settings V 0V FG LED names Marking State Display color Description MS NS Lights up Flashing Lights up Flashing Shut off Lights up Flashing Lights up Flashing Shut off Green Red Green Red Normal status No setting status Serious breakdown Minor breakdown No power supply Communication connection achieved No communication connection Serious communication fault Minor communication fault No power supply Remarks Conforms to DeviceNet (CompoBus/D) Number of outputs per block Maximum of 6 solenoids Related materials: User s manual, document No.HV0 For details about specifications and handling, see the above-listed user s manuals (Document No. HV00HV0). MS NS V CAN L Drain CAN H V Wiring Details and Serial Transmission (Flat cable length approximately 90mm [.5in.], DIN rail length 75mm [in.])

Operating Principle and Symbol -port Column Plunger Molded solenoid Manual override Flapper Valve body Lip seal End cover -port Normally closed (NC) Normally closed (NC) Normally open (NO) HJA0A De-energized HJA0A De-energized Plunger spring Piston Exhaust valves Stem Normally open (NO) HJA0A De-energized HJA0A De-energized 5-port, -position Single solenoid HJA0A5 De-energized Major Parts and Materials Valve Manifold Parts Materials Body Aluminum alloy (anodized) Stem Aluminum alloy Exhaust valve Lip seal Synthetic rubber Flapper Sub-base Aluminum alloy (anodized) Plunger Column Magnetic stainless End cover Plastic Monoblock Aluminum alloy (anodized) Split type Plastic Block-off plate Steel (nickel plated) Seal Double solenoid Synthetic rubber HJA0A6 De-energized condition after energizing solenoid (SB) Body

5-port, -position All port block HJA0A7 Tandem -port, -position Both (SA) and (SB) are de-energized Normally closed (NC), Normally closed (NC) HJA0AA Both (SA) and (SB) are de-energized ABR connection HJA0A8 Normally open (NO), Normally open (NO) HJA0AB PAB connection HJA0A9 Normally closed (NC), Normally open (NO) HJA0AC Operating Principle and Symbol

5

Series Order Code The solenoid valves HJA series order code is classified into the following 5 categories. For details on order codes, see the designated pages. HJA0ASingle valve unit HJAMAMonoblock manifold p. 7 p. 9 HJAMNJSplit manifold non-plug-in type p. HJAMPJSplit manifold plug-in type HJAMSJSerial transmission type p. 5 p. 9 6 Order Code

Single Valve Unit Order Code Model Model HJA0 HJA0L HJA0 Standard type HJA0L Low current type Valve specification A:-port normally closed A:-port normally open A:-port normally closed A:-port normally open A5:5-port -position, single A6:5-port -position, double Valve specification A A A A A5 A6 A7 A8 A9 AA AB AC A7:-position, all port block A8:-position, ABR connection A9:-position, PAB connection AA:Tandem -port (normally closed & normally closed) AB:Tandem -port (normally open & normally open) AC:Tandem -port (normally closed & normally open) Sub-base -5 Note Manual override -8 Sub-base Without sub-base Note With sub-base Note -5 Manual override Non-locking type Locking protruding type -8 Wiring specification -PN -PS -PS -MS -MS Wiring specification Plug-in Voltage -D VDC -D5 VDC Plus common S type plug connector Lead wire 00mm[in.] -PS Minus common S type plug connector Lead wire 00mm[in.] Note -MS S type plug connector Without connector and leads Voltage -D -D5 -PN Plus common S type plug connector Lead wire 000mm[8in.] -PS Minus common S type plug connector Lead wire 000mm[8in.] Notes:. Cannot be used as a single valve unit. Two manifold mounting screws are provided.. If using with a sub-base, the (plug-in) cannot be selected as wiring specifications. Select from among -PN, -PS, -PS, -MS or -MS.. -D5(VDC) is not available in the low current type. Note Note -MS 7

Additional Parts Order Code for Single Valve Unit Parts for single valve unit HJAZ - Connector-related HJAZ - Parts content 5 : Sub-base (sub-base and gasket) Note GS : Gasket Note Notes:. Valve mounting screws are not included.. Be aware that this gasket is different from the GS gasket for the split manifolds. Connector specification CP : Plus common plug connector, lead wire length 00mm[in.] CP : Plus common plug connector, lead wire length 000mm[8in.] CPN : Plus common plug connector, without lead wire (short bar and contacts included) CM : Minus common plug connector, lead wire length 00mm[in.] CM : Minus common plug connector, lead wire length 000mm[8in.] CMN : Minus common plug connector, without lead wire (short bar and contacts included) HJAZ-GSGasket HJAZ-5Sub-base Order Code 8

Monoblock Manifold Order Code Left side Model HJA0 Standard type HJA0L Low current type Valve specification A:-port normally closed A:-port normally open A:-port normally closed A:-port normally open A5:5-port -position, single A6:5-port -position, double Model HJAM Number of units 0 Manifold code Right side A Manual override Non-locking type Station stn. stn. Note Locking protruding type Model HJA0 HJA0L Valve specification Notes:. Valve mounting location is from the left, with solenoid on top, and (A) and (B) ports in front.. -D5(VDC) is not available in the low current type. -8 A7:-position, all port block A8:-position, ABR connection A9:-position, PAB connection AA:Tandem -port (normally closed & normally closed) AB:Tandem -port (normally open & normally open) AC:Tandem -port (normally closed & normally open) Wiring specification S type plug connector Without connector and leads Plus common S type plug connector Lead wire 00mm[in.] A A A A A5 A6 A7 A8 A9 AA AB AC -PN -PS -PS -CPS -CPS Minus common S type plug connector Lead wire 00mm[in.] Manual override -8 -MS Plus common Minus common S type plug connector S type plug connector Lead wire 000mm[8in.] Lead wire 000mm[8in.] -MS Plus common pre-wired connection Minus common pre-wired connection S type plug connector S type plug connector Lead wire 00mm[in.] Lead wire 00mm[in.] -CMS Plus common pre-wired connection Minus common pre-wired connection S type plug connector S type plug connector Lead wire 000mm[8in.] Lead wire 000mm[8in.] HJABP (for block-off plate) -CMS Wiring specification Mounting valve code -PN -PS -PS -CPS -CPS -MS -MS -CMS -CMS Back pressure preventive valve Without back pressure preventive valve -E With back pressure preventive valve Back pressure preventive valve -E Individual air supply spacer -NPM Individual air supply spacer Without spacer Voltage -D With individual air supply spacer -NPM Voltage -D VDC -D5 VDC -D5 Note Note 9

Additional Parts Order Code for Monoblock Manifold Manifold parts HJAZ - HJABP Connector-related HJAZ - Parts description GS : Gasket E : Back pressure preventive valve ( pcs. for monoblock type) NPM: Individual air supply spacer (Spacer body, gasket and mounting screws) Block-off plate (block-off plate and mounting screws) HJAM6A Connector specification CP : Plus common plug connector, lead wire length 00mm[in.] CP : Plus common plug connector, lead wire length 000mm[8in.] CPN : Plus common plug connector, without lead wire (short bar and contacts included) PA : Plus common A type, plug connector lead wire length 00mm [in.] PA : Plus common A type, plug connector lead wire length 000mm [8in.] PB : Plus common B type, plug connector lead wire length 00mm [in.] PB : Plus common B type, plug connector lead wire length 000mm [8in.] PC : Plus common C type, plug connector lead wire length 00mm [in.] PC : Plus common C type, plug connector lead wire length 000mm [8in.] CM : Minus common plug connector, lead wire length 00mm[in.] CM : Minus common plug connector, lead wire length 000mm[8in.] CMN: Minus common plug connector, without lead wire (short bar and contacts included) MA : Minus common A type, plug connector lead wire length 00mm [in.] MA : Minus common A type, plug connector lead wire length 000mm [8in.] MB : Minus common B type, plug connector lead wire length 00mm [in.] MB : Minus common B type, plug connector lead wire length 000mm [8in.] MC : Minus common C type, plug connector lead wire length 00mm [in.] MC : Minus common C type, plug connector lead wire length 000mm [8in.] For details, see p.5. Manifold Order Code Example (6 units of HJA series) stn. HJA0A5-PS-D stn.5 HJA0A6-PS-D stn.6 HJABP Note: This order code example has no relation to the illustration above. Precautions for Order Code Order for valves only Place orders by Single Valve Unit Order Code on p. 7. For common terminal wiring connections, order separately the common connector assemblies listed above. HJAZ-GSGasket HJABPBlock-off plate 0 Order Code

Split Manifold Non-Plug-in Type Order Code Left side Model HJAM Right side Piping block specification (air supply and exhaust) -JR :(P) and 5(R) ports 5/6 tube fitting right-side mounting -JL :(P) and 5(R) ports 5/6 tube fitting left-side mounting -JD :(P) and 5(R) ports 5/6 tube fitting both-side mounting -JR/ :(P) and 5(R) ports / tube fitting right-side mounting -JL/ :(P) and 5(R) ports / tube fitting left-side mounting -JD/ :(P) and 5(R) ports / tube fitting both-side mounting -JR/8 :(P) and 5(R) ports /8 tube fitting right-side mounting -JL/8 :(P) and 5(R) ports /8 tube fitting left-side mounting -JD/8 :(P) and 5(R) ports /8 tube fitting both-side mounting The photo shows the -JR type. -MR :(P) port 5/6 tube fitting, 5(R) ports built-in muffler right-side mounting -ML :(P) port 5/6 tube fitting, 5(R) ports built-in muffler left-side mounting -MD :(P) port 5/6 tube fitting, 5(R) ports built-in muffler both-side mounting -MR/ :(P) port / tube fitting, 5(R) ports built-in muffler right-side mounting -ML/ :(P) port / tube fitting, 5(R) ports built-in muffler left-side mounting -MD/ :(P) port / tube fitting, 5(R) ports built-in muffler both-side mounting -MR/8 :(P) port /8 tube fitting, 5(R) ports built-in muffler right-side mounting -ML/8 :(P) port /8 tube fitting, 5(R) ports built-in muffler left-side mounting -MD/8 :(P) port /8 tube fitting, 5(R) ports built-in muffler both-side mounting The photo shows the -MR type. Valve units 0 Manifold code Model HJA0 Standard type HJA0L Low current type NJ Valve specification A: -port normally closed A: -port normally open A: -port normally closed A: -port normally open A5: 5-port -position, single A7: -position, all port block A8: -position, ABR connection A9: -position, PAB connection AA: Tandem -port (normally closed & normally closed) AB: Tandem -port (normally open & normally open) A6: 5-port -position, double AC: Tandem -port (normally closed & normally open) Piping block specification (air supply and exhaust) -JR -JL -JD -JR/ -JL/ -JD/ -JR/8 -JL/8 -JD/8 -MR -ML -MD -MR/ -ML/ -MD/ -MR/8 -ML/8 -MD/8

Manual override Non-locking type Station stn. stn. Note Locking protruding type -8 Model HJA0 HJA0L Wiring specification Plus common S type plug connector S type plug connector Without connector and leads Lead wire 00mm[in.] -PN Valve specification A A A A A5 A6 A7 A8 A9 AA AB AC Manual override -8 HJABP (for block-off plate) -PS -PS Plus common Minus common pre-wired connection pre-wired connection S type plug connector S type plug connector Lead wire 00mm[in.] Lead wire 00mm[in.] -CPS -CPS Minus common S type plug connector Lead wire 00mm[in.] Wiring specification -PN -PS -PS -CPS -CPS -MS -MS -CMS -CMS -MS Plus common Minus common S type plug connector S type plug connector Lead wire 000mm[8in.] Lead wire 000mm[8in.] -MS -CMS Plus common Minus common pre-wired connection pre-wired connection S type plug connector S type plug connector Lead wire 000mm[8in.] Lead wire 000mm[8in.] -CMS Manifold fitting specification Mounting valve code -J/8 -J5/ -J/ Manifold fitting specification With /8 tube fitting Back pressure preventive valve Without back pressure preventive valve -E With back pressure preventive valve Back pressure preventive valve Notes:. Valve mounting location is from the left, with solenoid on top, and (A) and (B) ports in front.. Splits can be installed only when piping blocks are mounted on both sides. In addition, only location of each split can be mounted in one manifold for -SA, or one each split for -S and -S for a total of two locations. When in delivery, the designated splits are mounted between the designated station and the station to its immediate left (the next smaller stn. No.).. -D5(VDC) is not available in the low current type. -J/8 With fitting -J5/ With / tube fitting -J/ -E Individual air supply spacer -NPM Individual air supply spacer Without spacer Split With individual air supply spacer -NPM : Without split -S : For (P) port -S : For (R) and 5(R) ports -SA : For (P), (R) and 5(R) ports Voltage -D VDC -D5 VDC Split -S Note -S Note -SA Note Note Voltage -D -D5 Note Order Code

Additional Parts Order Code for Split Manifold Non-Plug-in Type Manifold parts HJAZ - Connector-related HJAZ - Parts description GS : Gasket (for split type) E : Back pressure preventive valve ( pcs. for split type and pce. gasket) J/8 : pcs. /8 tube fittings, and pce. stopper pin J5/ : pcs. 5/ tube fittings, and pce. stopper pin J5/6 : pcs. 5/6 tube fittings, and pce. stopper pin J/ : pcs. / tube fittings, and pce. stopper pin J/P : pcs. / tube fittings for (P) and 5(R) ports, and pce. stopper pin J/8 : pcs. /8 tube fittings, and pce. stopper pin M : Muffler for piping block NPM : Individual air supply spacer (spacer body, gasket and mounting screws) S : Split for (P) port S : Split for (R) and 5(R) ports SA : Split for (P) port, (R) and 5(R) ports Block-off plate (block-off plate and mounting screws) HJABP Piping block assembly HJAZ - End blocks (one set of left and right) HJAZ - E HJAZ - Connector specification CP : Plus common plug connector, lead wire length 00mm[in.] CP : Plus common plug connector, lead wire length 000mm[8in.] CPN : Plus common plug connector, without lead wire (short bar and contacts included) PA :Plus common A type, plug connector lead wire length 00mm [in.] PA :Plus common A type, plug connector lead wire length 000mm [8in.] PB :Plus common B type, plug connector lead wire length 00mm [in.] PB :Plus common B type, plug connector lead wire length 000mm [8in.] PC :Plus common C type, plug connector lead wire length 00mm [in.] PC :Plus common C type, plug connector lead wire length 000mm [8in.] CM : Minus common plug connector, lead wire length 00mm[in.] CM : Minus common plug connector, lead wire length 000mm[8in.] CMN: Minus common plug connector, without lead wire (short bar and contacts included) MA :Minus common A type, plug connector lead wire length 00mm [in.] MA :Minus common A type, plug connector lead wire length 000mm [8in.] MB :Minus common B type, plug connector lead wire length 00mm [in.] MB :Minus common B type, plug connector lead wire length 000mm [8in.] MC :Minus common C type, plug connector lead wire length 00mm [in.] MC :Minus common C type, plug connector lead wire length 000mm [8in.] For details, see p.5. Piping specification PJ (P) and 5(R) ports 5/6 tube fitting PJ/ (P) and 5(R) ports / tube fitting PJ/8 (P) and 5(R) ports /8 tube fitting PM (P) port 5/6 tube fitting, 5(R) port built-in muffler PM/(P) port / tube fitting, 5(R) port built-in muffler PM/8(P) port /8 tube fitting, 5(R) port built-in muffler Valve base assembly (valve base and gasket) Piping specification VJ/8 With /8 tube fitting VJ5/With 5/ tube fitting VJ/ With / tube fitting