DS100C6S. 2 Years or 2000 Hours Warranty. Power Your Dream! Enclosed structure, Small in size, High safety, Easy installation and operation

Similar documents
WPS60/S EP Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

WPS100/S EP Series. Features:

WPS350/S EP Series. Features:

WPS150/S EP Series. Features:

WPS250/S EP Series. Features:

WPS20/S EP Series. Features:

GMS100C/S EC Series. Features:

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GMS350C/S EC Series. Features:

GMS200C/S EC Series. Features:

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

EP series WPS150BS-AU rpm,3-phase/5-wiring

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Diesel Generating Set

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

CGT Stamford UCI 274 E1

FE - C KW / 650KVA 600KVA

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

EP series WPS100S-AU rpm,3-phase/5-wiring

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

TPD2250H6.3 TECHNICAL DATA

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

EP series WPS800S rpm,3-phase/5-wiring

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

PGKT / / / / / / / / / / / /

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel Generating Set

Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

EC series GMS30CS-AU 50

PGDLS / / / / / / / / /

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Rental Power QSB7 series engine

Diesel Generating Set. Generator Ratings

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Spark-ignited generator set

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel generator set 6BT5.9 series engine

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Rental Power QSL9 series engine

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

WCS2000 / WCS2000S. Features: WCS Series

Model NA 2 L

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Diesel Generating Set

Diesel generator set 4BT3.3 series engine

Technical Data 1600KW / 2000KVA 1450KW / 1813KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz)

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Diesel generator set QSK23 series engine

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

Rating Definitions and Conditions

Model MP150 W W

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Diesel generator set QSX15 series engine

Diesel generator set QSK50 series engine

DIESEL GENERATOR SET. 60 Hz FEATURES

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

DIESEL GENERATOR SETS

APD-ULJ250. Standby Power

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PPU Diesel Power 50/60Hz Containerized Generator Set

Spark-ignited generator set

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Prime Ratings (KW/KVA) 400/ / / /910

Diesel Generating Set

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel generator set QSL9-G7 series engine

SIVASA Doosan Series. SD250 Technical Data

Diesel generator set QSB7 series engine

RENTAL DIESEL GENERATOR SET

Rating Definitions and Conditions

Transcription:

Power Your Dream! 2 Years or 2000 Hours Warranty Enclosed structure, Small in size, High safety, Easy installation and operation www.potise.com

kva Prime Power 110 88 Standby Power 121 125 97 100 Basic Information kw Prime Power: Continuous duty operation, under variable load 2424h-10% over load permissible 1 hour12 hours; Standby Power: Standby duty, operation under variable load, without over load; Power rating: Permissible average power output during 24 hours of operation is approved up to 75%; Excitation system: self-excited shunt Emergency stop button ATS receptacle Lockable battery isolator switch Powder coated canopy Dry type air filter Base fuel tank for 8-12 hours running, with drain point Engine-generator set tested to ISO 8528-5 for transient response Ratings and Performance Data Engine brand Cummins Engine model 6BT5.9-G2 Accepts rated load in one step per NFPA 110 Global product support Cooling system with 50 raditor Permanent magnet generator Alternator brand Potise -Brushless, rotating field generator Alternator model PL3B -300% short circuit capability Control system Noise level @ 7m Circuit breaker type Frequency and phase Engine speed: rpm Structure type ComAP-AMF 65dB(A) -23 pitch windings Terminal box 60 Hz & 3 Phase 1800 Sound proof Fuel tank capacity 180L 220L Fuel consumption 20 Lh at 75% load Standard Reference Conditions: Note: Standard reference conditions 25 C (77 F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Certified: Engine-generator set is designed and manufactured in facilities certified to standards ISO 9001:2008 Model Dimensions Dry Weight L*W*H mm (kg 2850*1100*1650

Strong Power, Reliable Performance Engines Excellent engines featured with strong power, high torque, quick start, easy maintenance and operation. Torque Nm Speed RPM - RPM 0% 5-10% 10-14% World class engines and alternators featured with strong power, high torque, quick start, easy maintenance and operation. Advanced AVM device significantly reduce vibration during operation, ensuring stable operation of the genset. The air filter can adopt double-element, which can be used in larger occasions. Excellent cooling system and 50 radiator. All movable devices are fixed firmly, and therefore help reduce vibration. Reasonable air intake design ensures sufficient combustion of engine Excellent exhaust pipe endures high temperature and makes sure tough working condition.

Stable Performance H class insulation IP 23 (or NEMA 1) protection class Sustained voltage(v) Overload Overload-trip Self-excitation (brushless) 4-pole rotate magnetic field Voltage fluctuation rate within ±0.5% Speed variation rate within 5% 5% ±0.5 UN Sustained voltage dip Shunt Shunt Arep PMG Arep Load range from 0 to 100%, the frequency fluctuation rate shall be±0.25%; ±0.2 100% 180% 300% Load% Three phase load, the maximum line voltage wave form distortion rate is less than 5%; Three phase Reliable Single phase Alternator Data Alternator manufacture brand Alternator model: Exciter Cooling fan Windings Insulation class Winding pitch Terminals Drip proof Potise PL3B Brushless Cast alloy aluminum 100% copper H 23 12 IP21 Emergency voltage curve Sudden voltage warp 520 464 408 352 296 Sudden increase warp Sudden decrease warp +1% -1% 380 240 0 1 2 3 4 5 6 7 8 9 10 11 12 Benchmark phase: A Min. voltage: 310.9V Recovery time: δu%: -18.18 1.95s Benchmark phase: A Max. voltage: 413.8V Recovery time: δu%: 8.89 0.12s Emergency frequency curve Altitude 1000m Over-speed 2250rpm Air flow 0.514m3s Voltage regulation ±1.0% Total harmonic TGHTHC at no load 5% Telephone interference THF 2%; TIF 50 In conformity with ISO8528:2005; Ambient temperature: -25 to 45. The coolant heater is needed when the temperature is below 5 ; Humidity: less than 80%. Sudden voltage warp 70 62 54 46 38 Sudden increase warp Sudden decrease warp +1% -1% 50 30 0 1 2 3 4 5 6 7 8 9 10 11 12 δf%: -10.64 Benchmark phase: A Min. frequency: 44.68Hz Recovery time: 1.95s Benchmark phase: A Max. frequency: 53.87Hz Recovery time: δf%: 7.74 0.54s

Humanized Design and Easy Operation Control Panel Emergency Stop Button Alternator Air Inlet Output Fuel Drain Air Filter Protective Cover Radiator Excessive Kettle Manual Fuel Inlet Fuel tank (1000-2000L) The water filling device on top of the canopy makes it convenient to fill water. The generator is mounted with a vehicle type base frame fuel tank, fuel intake and The generator set can be easily connected to an external fuel tank for a long period of continuous operation. fuel level monitoring system; High performance maintenance-free batteries can provide 1300 amp current for 30 seconds under the temperature of 18. Lubricating oil can be transferred to the outside of the soundproof canopy; The automatic fuel filling device is also optional.

Easy Maintenance Two-side inspection design The generator set is complete equipped. The daily maintenance work can be performed on both sides of the machine, and the wide doors allow easy access to all areas of the machine. Flat base frame design Flat structure design of the base frame under the generator set make it convenient for inside cleaning work of the generator set. Lifting lugs located on top of canopy make it easier to move the machine by crane. The canopy ceiling consists of mounted cold rolled sheet and U-shaped rings. The U-shaped rings are galvanized and rust-proof. 8-30 hour double layer base fuel tank (for more information about the big tank, please check our technical data page) 1 3 2 5 4 1 Air Filter 4 Fuel Inlet Outer filling fuel port; 2 Wire Harness 5 Oil Filter 3 Fuel water seperator

Intelligent Control System ComAP-AMF is an advanced control module based on micro-processor, containing all necessary functions for protection of the genset and the breaker control. It can monitor the mains supply, and automatically start the engine when the mains is abnormal. Accurately measure various operational parameters and display all values and alarms information on the LCD. In addition, the control module can automatically shut down the engine and indicate the engine failure. Simple and safe microcomputer modular operation Microprocessor control, with high stability and credibility; Monitoring and measuring operational parameters of the mains supply and genset; Indicating operation status, fault conditions, all parameters and alarms; Multiple protections; multiple parameters display, like pressure, temperature, etc; Manual, automatic and remote work mode selectable; Real time clock for time and date display, overall runtime display, 200 log entries; Overall power output display; Integral speed frequency detecting, telling status of start, rated operation, over-speed, etc; Communication with PC via RS485 or RS232 interface, using MODBUS protocol; The controller integrates digital, intelligent and network technology; Micro-processor cored digital system makes the control of the genset much more convenient and intelligent; Multi-language optional for easy operation; Whole system performance status display to ensure efficient and reliable operation of the machine; Automatic control, and cost-effective operation; Connected with the mains through ATS, which can help realize automatic transfer between the mains and generators. Also, multiple generators can be paralleled for bigger power needs.

Enhanced Safety Safe soundproof canopy device The gensets are equipped with grounding protection, access door lock, cable outlet, mouse proof device, oil tank leak-proof device, water tank hood and overflow kettle. Leakage protection device: the genset is equipped with NFB leakage protection device, which helps to cut off circuit when sensing the condition of leakage; High-temperature protection: high-temperature alarm device is equipped to avoid injury caused by direct contact of the genset by operator. Automatic alarm system: the genset is equipped with monitoring system and emergency stop device, which greatly enhance the safety of the operation. Output terminal The double protection for the cable connection panel lowers the probability of leakage caused by unintended touch or rain falling. At the same time, the terminal connection lugs (UVWNE) make connection and wiring much more simple and well-ordered. Safety protection All rotary parts are enclosed in a metal box, which ensures the safety of the operator. Exhaust system high temperature protection package. Intelligent monitoring of operation situation Automatic control module for multi-directional monitoring meets multilevel demands and considerate protection of or for customers. Item Operation display Engine stop Load stop Display failure Low oil pressure High water temperature Over current Electric leakage Adverse charge Block of air filter Rising of fuel and water level Over speed

Environmental The high quality electrolysis board has a service life of 15 to 20 years. The canopies are coated by ultraviolet-proof powder, which has a service life of 5 years. The canopies are all galvanized and with the material of stainless steel. IP 45 class dust and rain proof design. Canopy materials: Specular Powder Coating High Standard Sheet Metal production processes Reasonable Design of Inlet One Key System The Image of The Logo Design Materials Used on Canopy and Base Perfect Emission System Component Soundproof Canopy Bracket Material Advanced Electrolysis Board Hot-rolled Plate Thickness(mm) 2.0 6.0 Extraordinarily low emission, economic and environmental-friendly, ensuring cleanliness and no pollution to environment even it is used outdoors. Main Supporting Column Base 55-75dBA@7m Sound Pressure Level Silencer, muffler pipe system and airproof rubber around the doors dramatically reduce the noise of the generator during operation. Hot-rolled Plate Hot-rolled Plate Emission-Noise (routine sound value) 6.0-10.0 4.0-12.0 0 20 40 60 80 100 120 140 db audible threshold Forest Library Office Truck Jet aircraft pain threshold Two-segment air filtering rate 50-62dBA@7m Centrifugal Pre-Filter Action Ejected Dust Swept Through Filter and Collected in Dust Cup Filter Element Vacuator Valve (Optional) Empties Dust Cup Automatically Safety Element included Ultra silent Soundproof genset Open genset 55-75dBA@7m Soundproof

Compact Structure and Safe Package The genset is in compact structure, which makes it easy for transportation. The generating set is packed with beautiful and neat UV protection thin aluminum material which is dust proof and rain proof, and can be used repeatedly. Excellent Parts Fuel tank The muffler Battery charger Made of high standards mould forming process. With leakage protection, high tension, high quality of weld neat, well paint, etc. Directly observe the oil level from the tube. Impedance integrated. Adopted anti-rust materials. Surface under high temperature lacquer bake process. Not easy to rust even if under open air and rains. Reduce noise more than 15db. Switch power supply structure, wide input alternating voltage range, small size, light weight, high efficiency rate. Short-circuit protection. Air filter Wiring harness and pipeline Screws and locks Double layer filter. Suitable for large dust places. Such as mines, construction sites, processing workshops and extreme weather conditions. Circuit wiring harness sheath adopts standard corrugated tube. Oil-resistant pipeline fixed by pipe clamp. All screws and locks used in the genset are made of stainless steel or galvanized material.

Specification and Configuration Ratings and Performance Data Exhaust System No. of cylinders alignment: 6 Vertical in line Silencer type: Industrial Cycle: 4 Stroke Diameter of exhaust pipe Bore stroke: mm (in) 102X120 recommended: 75 Induction: Turbocharged Maximum allowable back Cooling method: Water cooled Pressure (mmhg): 76 Governing type: Electrical Exhaust gas flow (m³min) Governing class: ISO 8528 G2 - Prime: 250 Compression ratio: 16.8:1 - Standby: 280 Displacement (L): 5.9L Exhaust gas temperature Speed droop: 5% - Prime ( C): 526 Engine Electrical System: - Standby ( C): 565 -Battery voltage: 1224V - Battery Charger Amps: 63A40A Weight (kg) - Dry: 411 - Wet: NA Performance Air Systems Engine speed (rpm): 1800 Air filter type: Dry Gross engine power (kw) Max. air intake restriction: - Prime: 86 mmh2o - Standby: 92 -Clean filter: 254 Distance between gravity -Dirty filter: 635 center and rear surface of Diameter of intake pipe cylinder block (mm): 544 recommended (mm) : 100 Lubrication System Cooling System Rated speed (kpa): 345 Low idle (kpa): 207 Max. oil temperature permitted in oil pan ( ): 121 Fuel System Total fuel overflow amount 30 (Lh) : Fuel consumption: lhr lhr Power 100% load 75% load 50% load 25% load NA NA NA NA Coolant capacity (L): 9.9 Max. coolant cycling resistance exterior engine (kpa): 28 Thermostat adjusting temperature (range) ( ): 82-95 Min. opening pressure of radiator cap (kpa): 69 Max. coolant temperature permitted( -Prime power: 100 -Standby power: 104 Designed to operate in ambient conditions up to 50 C (122 F). Contact your local PowerLink Dealer for power ratings at specific site conditions. (Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2)

Application Due to its advantages of compact structure and easy operation, the generator sets are widely used in various industries, such as mining, oil field, telecom, military, aviation, municipal construction, as well as residential and office building, etc. Building Hospital Rail Station Bank Telecommunication Oil field Outdoor engineering Mine Power Plant Military Field Prime Power Warranty Limited Warranty for New Generating Sets Base Warranty Coverage Duration (Whichever occurs first) Rating Months Max. Hours Delivery time Months COP Continuous Power 12 2000 hrs 18 PRP Prime Power 12 2000 hrs 18 LTP Limited-Time Running Power 24 500 hrs 27 (2 years or 2000-hour quality guarantee) Optional For genset equipped with double layer fuel tank or super low noise device and low emission performce, please contact the salesman before ordering. www.potise.com Potise reserves the right to make changes in model, sepcification, colour, configuration and accessories without prior notice. Please contact the salesperson before ordering.