FPC815 Pneumatic Rivet Tool

Similar documents
FPC835M Air Hydraulic Rivet Tool

Air Hydraulic Rivet Tool

MP-4V Heavy Duty Riveter / 39048

POP 4000 SERIES RIVET TOOLS

M39075 ( IF- 1) Integra- Fuse Rivet Tool

RH160E. Rivet Nut setting Tool (Spin /Pull) Instructions & Parts List

Safety, Operation and Maintenance Instructions For Long & Short Nose Upholstery Air Stapler (NS10 & NS11)

MODEL EGA200 OWNERS MANUAL

18 GAUGE FLOORING STAPLER. Models: /13

1/4 ANGLE DIE GRINDER

MODEL EGA130 OWNERS MANUAL

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

MODEL EGA220 OWNERS MANUAL

RIV302-E Heavy Duty Riveter / 39062

39223 (140-SP) Rivet Nut setting Tool (Spin /Pull)

- Keep children and other people away while operating the rivet tool. Distractions can cause you to lose control of the tool.

MINI AIR ANGLE DIE GRINDER

Single shot MODEL EGA700 OWNERS MANUAL

Operating Instructions & Parts Manual. Air/Manual Hydraulic Bottle Jacks

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

4069 Operating Instructions

SERIES OPERATION AND MAINTENANCE MANUAL

20 TON AIR/MANUAL BOTTLE JACK

GBP784B INSTALLATION TOOL

AIR PAINT SHAKER OWNER'S MANUAL

Dome-Loaded Pressure Reducing BD-Series

Hydraulic PTO Flow Device

TUG HD BELT CLAMP. Safety and Operation Manual WARNING

Abrasive Blast Cabinet Assembly & Operating Instructions

BOLT TENSIONERS. carefully before use and retain it for reference.

OPERATING INSTRUCTIONS

Hydraulic Truck Jack

Air Actuated Hydraulic Bottle Jacks

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

GB7624 GAGE BILT MADE IN U.S.A. HYDRAULIC INSTALLATION TOOL

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Operating Manual. FloorMaster FS Flooring Stapler A18201 READ ALL SAFETY INSTRUCTIONS

CRD610 Automatic Fitting Inserter

110 Volt/12 Volt Portable Inflator

Long Chassis Hydraulic Service Jacks

Hydraulic Long Jacks

Hydraulic Knockout Sets

ANGLE DIE GRINDER KIT

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

1/4 Die Grinder. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

REED MANUFACTURING COMPANY

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

HYDRAULIC ROLL GROOVING ATTACHMENT 1/2-12

CRD600 Automatic Fitting Inserter

Hydraulic Bead Breaker Kit

USER INSTRUCTIONS FOR OPERATION & MAINTENANCE 4068 Pneuma c / Hydraulic Installa on Tool

Telescoping Pressure Washer Wand 18'

Hydraulic Immediate Need Power Pack

Low Profile Service Jack Jack Stand Combo

Angle Grinder Holder

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

2-in-1 Air Operated Waste Oil Drainer

1500- LB. HIGH POSITION HOIST STAND OWNER S MANUAL

SB20G. Large Pressurized Abrasive Blaster Assembly & Operating Instructions

12V Oil Extractor Pump

POLISHER KIT Model 95030

SAFETY AND OPERATING MANUAL. Lithium-Ion cordless hammer drill WX372 WX372.1 WX372.9

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

HEAVY DUTY TROLLEY JACK. Operation Manual

LS100L Battery-powered Punch Driver

SPECIFICATIONS CONTENTS:

Air Actuated Hydraulic Bottle Jack on Wheels

Alligator Staple Gold Class Plus

Air-Assist Service Jack Max. Capacity: 10 Tons

2 Speed Hydraulic Hand Pump

MagicLift Hydraulic Service Jack Model (w/one piece handle) (w/one piece handle)

Fast Lift Service Jack, Low Profile

Large Hydraulic Bead Breaker

Operating Instructions & Parts Manual

AIR/HYDRAULIC TRUCK JACK 22T

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

Hydraulic Bottle Jack Manual

CAMBELT TENSION GAUGE

Mini Jacks Instruction Manual

Pressure Washer Hose Reel

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

Heavy Duty Bottle Jacks

Low Profile Service Jack

AIR-POWERED IMPACT WRENCH

Air-Operated 5:1 Oil Pump

SPECIFICATIONS CONTENTS: Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

OWNER S MANUAL PRODUCT CODE: 2006T

Hydraulic Transmission Jack, Telescopic

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Auto-Locking Pintle Hook

150-Lb. Drywall and Panel Hoist

MODEL HD99 HYDRAULIC ONE MAN TOWABLE EARTHDRILL

12 Volt Heavy-Duty Air Inflator

Heavy Duty Engine Cranes

SPECIFICATIONS CONTENTS:

750-LB. OUTBOARD MARINE ENGINE JACK

High Lift Transmission Jack

Transcription:

WARRANTY If you have any problems with this tool, please call FPC Corporation toll-free at 1-800-860-3838 before returning it to the place of purchase. FPC815 Pneumatic Rivet Tool FPC Corporation warrants this product to be free from defects in material and workmanship, under normal conditions of use and when used in accordance with FPC operating instructions, for a period of 90 days from the date of purchase by the user. Within the 90 day warranty FPC at its option shall repair or replace product. The product must be returned at the distributor/user expense, either within warranty or out. Repaired or replaced products will receive a 60 day warranty. Visit us at surebonder.com for our full line of products FPC Corporation - 355 Hollow Hill Drive - Wauconda, IL 60084 Phone: (847) 487-4583 Fax: (847) 487-0174 website: www.surebonder.com e-mail: sales@surebonder.com 1010 Operating Instructions Read All Safety Rules and Instructions Carefully Save this manual for Future Reference

! DANGER This manual contains important information about product safety. Read and understand this entire manual before operating this tool. SEAL AND SPRING PIN KITS 815M-400 PARTS s not sold separately Call for price s sold separately B01 815M-B01 "O" Ring Included 2 1 815M-314 NOSEPIECE 3/32" Call 1 B02 815M-B02 "O" Ring Included 1 1 815M-414 NOSEPIECE 1/8" Call 1 B03 815M-B03 "O" Ring Included 1 1 815M-514 NOSEPIECE 5/32" Call 1 B04 815M-B04 "O" Ring Included 2 1 815M-614 NOSEPIECE 3/16" Call 1 IMPORTANT SAFETY WARNINGS: THE SAFETY WARNINGS BELOW CANNOT COVER ALL POSSIBLE SITUATIONS THAT MAY OCCUR. THESE BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO PROTECT AGAINST PERSONAL INJURY TO THE OPERATOR OR OTHER PERSONNEL IN THE AREA, AS WELL AS DAMAGE TO THE EQUIPMENT. READ AND UNDERSTAND THESE WARNING BEFORE USING EQUIPMENT. Keep tool away from children, and DO NOT allow children near work area. Do not allow children or untrained personnel to handle this tool. DO NOT operate this tool while tired, or under the influence of drugs, alcohol, or medication that makes you drowsy. Never point the tool at yourself or others - always assume that the tool is loaded, and proceed with caution. Wear safety glasses and ear protection. The operator and all personnel in the work area must wear safety glasses that protect the front and side, to avoid eye injury. Ear plugs should be worn to avoid hearing damage. Never use oxygen, bottled gas or any type of combustible fuel as a power source - it can cause an explosion and serious injury. Use an air hose that will withstand at least 150 PSI, OR 150% of the maximum pressure of the compressor. Never connect this tool to compressed air if the pressure could exceed 200 PSI, as the tool could burst. Use only clean, dry, regulated compressed air, with pressure not exceeding 95PSI. Do not use an air hose that is too long-tool operator can trip over it. Make sure all connections are tight. (WARNINGS continued next page) ANSI Z87.1 B05 815M-B05 "O" Ring Included 1 2 815M-02 OUTER SLEEVING Call 1 B06 815M-B06 SPRING PIN Included 1 3 815M-03 JAW CASE Call 1 B07 815M-B07 SPRING PIN Included 2 4 815M-04 JAWS Call 1 B08 815M-B08 SPRING PIN Included 1 5 815M-05 JAW PUSHER Call 1 B09 815M-B09 "O" Ring Included 1 6 815M-06 COMPRESSION SPRING Call 1 B10 815M-B10 "O" Ring Included 1 7 815M-07 JAW CYLINDER Call 1 B11 815M-B11 "O" Ring Included 1 8 815M-08 LOCK NUT Call 1 B12 815M-B12 "O" Ring Included 1 14 815M-14 PLASTIC RING Call 1 B13 815M-B13 "O" Ring Included 1 15 815M-15 PRINCIPAL AXIS Call 1 B14 815M-B14 "O" Ring Included 1 16 815M-16 RESTORE SPRING Call 1 B15 815M-B15 SPRING PIN Included 1 17 815M-17 RESTORE SPRING Call 1 18 815M-18 AIRPROOF LID Call 1 20 815M-20 AIR CYLINDER Call 1 21 815M-21 LOCK NUT Call 1 22 815M-22 POLE Call 1 26 815M-26 TRIGGER Included 1 23 815M-23 CUSHION Call 1 27 815M-27 LINKER Included 1 24 815M-24 PISTON Call 1 28 815M-28 PRESS PLANK Included 1 25 815M-25 NUT Call 1 B07 815M-B07 SPRING PIN Included 2 29 815M-29 AIR VALVE Call 1 TRIGGER ASSEMBLY 815M-410 s not sold separately Call for price HANDLE ASSEMBLY 815M-420 s not sold separately Call for price 30 815M-30 VALVE SPRING Call 1 31 815M-31 SILENCER Call 1 32 815M-32 VALVE BASE Call 1 33 815M-33 STEEL BALL Call 1 9 815M-9 PLASTIC RING Included 1 34 815M-34 AIRPROOF SPRING Call 1 10 815M-10 HANDLE Included 1 35 815M-35 AIRPROOF NUT Call 1 11 815M-11 OIL FILL GASKET Included 1 36 815M-36 BOTTOM Call 1 12 815M-12 OIL FILL SCREW Included 1 37 815M-37 BASE COVER Call 1 13 815M-13 HOOK Included 1 38 815M-38 LINKER COVER Call 1 B01 815M-B01 "O" Ring Included 2 39 815M-39 GASKET Call 1 B04 815M-B04 "O" Ring Included 2 40 815M-40 NUT Call 1 19 815M-19 PLASTIC RING Included 1 41 815M-41 BOTTLE Call 1 Call 847-487-4583 to order parts and kits 1 10

FPC 815 parts list IMPORTANT SAFETY WARNINGS: continued Disconnect air hose from tool: -before performing maintenance. -when clearing a jam. -when tool is not in use. -when moving it to another location. Carry tool by the handle only, not by the air hose. Never use the tool if it is leaking air, tool has missing or damaged parts, or requires repair. Make sure all screws and caps are tightened. Inspect the tool before each use to insure all parts are operating properly. Lock the tool in a clean, dry storage area between uses. Only use parts and accessories supplied or recommended by FPC Corporation. Unauthorized parts or fasteners can lead to malfunction and serious injury. Only personnel trained by FPC Corporation or the distributor shall repair the tool. Do not modify this tool in any way. Do not store the tool in a cold weather environment. Keep the tool in a warm area until the start of work. If it is in a cold area, bring it in a warm area and allow it to warm up before use. Manufacturer assumes no responsibility for consequential or indirect damages from the use of this product. Save this manual and have it available for tool operators reference! 2

APPLICATIONS Installing 3/32, 1/8, 5/32 and 3/16 aluminum, steel, stainless steel blind rivets. Note: (3/16 stainless steel not recommended). Use for: Furniture, automotive, watercraft, ductwork, sheet metal, gutters, playgrounds, etc. FEATURES - Lightweight die cast aluminum body - 3 piece jaw design for greater pulling power - Mandrel collector MAINTENANCE (continued) Servicing and Cleaning Jaws To access jaws (part#4), remove outer sleeving (part#2) to expose pulling mechanism and jaw case (part#3). To remove jaw case from pulling mechanism, use 2 wrenches (included). Jaws will be under slight spring pressure from the jaw pusher. Separate jaw case from pusher. Jaws will now be loose. Clean jaws with a wire brush. Place a small dab of multipurpose Lithium grease or Lubriplate on outside of jaws (not serrated side). Return jaws into jaw case ensuring proper placement of jaws. All serrated faces should be touching each other. Note: see parts list on page 10 for all parts and descriptions AIR SUPPLY! DANGER NEVER use oxygen or other bottled gases. Explosion may occur. This tool is designed to operate on clean, dry, regulated compressed air, between 65 and 95 PSI. It is preferable to include an air filter and pressure regulator within 15 feet of the tool, if possible. Remove outer sleeving Remove jaw case An air filter is needed to remove contaminates and moisture that are contained in compressed air; filtering will significantly prolong the life of the tool. Do not install a quick coupler directly into the tool. Higher pressure drastically reduces tool life. The tool must always be connected to the air supply with a coupling that removes all pressure when it is disconnected. NOTE: All components used with this tool (air hose, connectors, regulators, filters, etc) must be rated at 120 PSI, or 120% of the maximum compressor potential, whichever is higher. Do not connect this tool to a system with maximum potential air pressure greater than 120 PSI. AIR CONNECTION SET UP To Tool Quick Connector Quick Coupler 60 80 100 40 120 20 140 0 160 To compressor SPECIFICATIONS Overall Dimensions: 8.75" x 10.75 Stroke:.625 Air Pressure: 65-95 PSI Pull Force: 1,800 lbs. Weight of Tool: 3.0 lbs. Air Consumption: 4.2 CFM Air Inlet: 1/4 NPT Fastener Selection Sets: 3/32", 1/8", 5/32", 3/16 aluminum, steel, stainless steel rivets (3/16 stainless steel rivets not recommended) 1.71" 10.750" Dimensions 8.750" Regulator Filter 3 8

OPERATION OPERATION Identification Outer Sleeving Oil Fill Screw Hook TOOL PREPARATION Determine the size rivet that you are going to use. The 3/16 nosepiece is factory installed. Also included are the 3/32, 1/8 and 5/32 nosepieces stored on bottom of the rivet tool. Note: Attach mandrel deflector to your tool at all times during use for your safety (see mandrel deflector instructions below). 3/16 Nosepiece Trigger Air Exhaust Mandrel Deflector Changing Nosepieces: Use wrench included to remove and replace your desired nosepiece. Unscrew nosepiece counter-clockwise. (Fig. 1) Select nosepiece that corresponds to the size rivet you are using and screw nosepiece clockwise onto rivet tool head. Attach air line to air supply (1/4 quick connect recommended (not included). Setting Rivets: Insert a rivet mandrel into the nosepiece until head of the rivet touches the nosepiece. Place the rivet into the hole of the material being used until contact is made with head of the rivet. (See chart below for correct hole sizes to drill) Squeeze the trigger to set the rivet. Release the trigger once the rivet is set. The spent mandrel will be ejected into the mandrel deflector by tilting the rivet tool backwards. The spent mandrels will drop out of the bottom of your deflector during use. Fig.1: Unscrew nosepiece counter clockwise onto rivet tool head. Air Inlet Base Cover Mandrel Deflector: Note: Mandrel deflector must be attached to tool at all times for your safety. Deflector should be screwed on rivet tool until deflector opening is facing downwards (Fig.2). The spent mandrels will be ejected in the deflector by tilting the rivet tool backwards. The spent mandrels will drop out of the bottom opening of your deflector during use. Fig.2: For your safety, mandrel deflector should be screwed on rivet tool with opening facing downwards before each use. Rivet Size Hole Size to Drill Drill Bit No. Extra nosepieces: 3/32, 1/8, and 5/32 are stored on bottom of rivet tool. The 3/16 nosepiece comes factory installed. 3/32".097"-.100" #41 1/8".129"-.133" #30 5/32".160"-.164" #20 3/16".192"-.196" #11 5 6

MAINTENANCE Lubrication It is important that the tool be properly lubricated. Every 10,000 cycles the tool should be oiled with lubricating oil. There may be insufficient oil if the stroke of the tool is too short for proper installation. Without proper lubrication the tool will not work properly and parts will wear prematurely. 1) Keep the tool upright during all operations. Disconnect the tool from the air supply. 2) Unscrew the oil fill screw from the body using an allen wrench (not included) (Fig. 5). 3) Fill the syringe (included) with hydraulic oil - use ISO 68 or AW 68 Anti-foaming high pressure hydraulic fluid (not included). 4) Screw the filled syringe in the oil fill screw hole. Then slowly inject the oil into the tool making sure no air is injected (Fig.6). Adequate oil has been added as soon as resistance is sensed. The excess oil will flow back when the syringe is release if more oil is added than necessary. 5) Unscrew and remove the syringe from the body. 6) Screw the oil fill screw into the hole using the allen wrench. 7) Wipe off any excess oil. To test oil level, reconnect rivet tool to air supply and depress trigger 2-3 times. Insert rivet into nosepiece (use the largest diameter rivet that tool accepts (3/16 ). Check to see if rivet mandrel can be inserted completely into nosepiece - head of rivet must touch nosepiece. If rivet cannot be completely inserted into tool, too much oil has been added and some must be removed. To remove excess oil unscrew oil fill screw approximately 1/4 turn. Once the tool is properly adjusted, tighten the oil fill screw firmly with the allen wrench and wipe off any excess oil. When the oil fill screw is unscrewed, oil will seep from the chamber. After the rivet mandrel is fully seated into the nosepiece, the oil level is then ready for operation. Air Supply Requirements Use a dry, filtered air supply regulated to 65-95 PSI (5-6 bar). A minimum of 65 PSI is recommended. If the recommended operating pressure is exceeded the tool may not function because of built up line pressure. For optimum performance connect the tool air line to an air supply of at least 1/4". If problems should occur with the setting of the pressure, disconnect the tool from the compressed air supply, to release pressure from the tool. Verify that the tool is in proper working order and that air-pressure level is properly set on the air compressor. Mode of Operation When the tool is connected to an air supply and the trigger is pulled, pressurized air pushes the air piston which acts on the hydraulic ram assembly. The hydraulic ram assembly forces hydraulic fluid from the reservoir in the handle into the main hydraulic bore where it moves the hydraulic piston together with the attached pulling mechanism rearward. As the pulling jaws move rearward they close on and grip the rivet mandrel and set the rivet. When the trigger is released air at line pressure forces the hydraulic piston forward to the starting position. As the hydraulic piston moves forward the hydraulic fluid is also forced back returning the hydraulic fluid and the ram assembly and air piston to the starting position. The compressed air used to set the rivet is exhausted through the base of the intensifier chamber. When the hydraulic piston is fully returned the broken rivet mandrel is released as the jaws are forced open again by the nosepiece. (Fig. 5.) (Fig. 6.) Unscrew oil fill screw Slowly inject the oil into the tool 7 4