Centro-Matic Automated Lubrication Systems Grease Injectors

Similar documents
Centro-Matic Automated Lubrication Systems Grease Injectors

Centro-Matic Automatic Lubrication Systems Grease Injectors

Lincoln Centro-Matic automatic lubrication systems

Centro-Matic. Automated Lubrication Systems

- C8. SINGLE AND MANIFOLD TYPE INJECTORS for dispensing fluid lubricants and greases not exceeding Lincoln ventmeter viscosity of 600 psi.

CXL2 Injectors & Manifolds

Pumping Ratio 50:1. ( bar) Max. Output 7500 psi. Air Inlet. Material Outlet. Airmotor Bore Dia. 3 in. (76.2 mm) Stroke

Model No , -2, -3, -4, -5, , , -2, -3, -4, -5, and SL-V INJECTOR Series A

Modular Lube. Automated Lubrication Systems

Grease and Oil Injectors

Installation Components AirCare Air Preparation Systems

Industrial Pumping Equipment PileDriver III Series III Air Motor Features

Modular Lube Lubrication Systems

Quicklub Lubrication Systems

Lincoln Quicklub centralized and automatic lubrication systems

Section 9: Centralized Lubrication Systems

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA

FIT-2. Inch. Ø Â" to Ë" O/D tube

Automatic Lubrication

QUICKLUB CENTRALIZED & AUTOMATED LUBRICATION SYSTEMS

Lubrication Installation Components, Accessories & Fittings Table of Contents

Installation Components AirCare Air Preparation Systems

HOSE REELS 151. Heavy-Duty Series

THE REVOLUTIONARY P653S ELECTRIC CENTRO-MATIC PUMP

SINGLE LINE PARALLEL SYSTEMS. GL-1 Series Grease Injectors.

People, Capabilities and Systems to Save Money and Increase Productivity

People, Capabilities and Systems to Save Money and Increase Productivity

Series 3000 Divider Valve Manifold

Injection Lubricators

Tubing and Accessories

Quicklub Lubrication Systems Fittings, Adapters and Accessories

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

Lincoln installation components, accessories and lubrication fittings

SOLUTIONS. Airless Spray System. In This Issue: Airless Spray System pg. 2. Improved FlowMaster pg. 5

POLYMED CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

Centralized & Automated Lubrication Systems. I design Quicklub and other systems to satisfy each customer s unique requirements.

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

Quicklub Lubrication Systems Fittings, Adapters and Accessories

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

ZEM Injector. Series 32, 33, 34, 35, 39. General. Operation. Features. Technical Data. Injector Outputs R2 08/10

General Lubrication Products High Pressure Stationary Grease Pumps

Industrial Pumping Equipment PowerMaster III

Spray & Foam Dispenser Item #

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

Accessories BSP BONDED SEALS

LubePro Series Pumps For Simple, Injector-based Automatic Lubrication Systems

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

SERVICE KITS PUMP DATA INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: XX-XXX-C. Figure 1. RELEASED 13/Nov/ :24:02 GMT

GREASE GUNS SECTION TWO. Battery Powered Grease Guns

RAM PUMP. With Alemite s wide range of pumps, you re sure to find one to meet almost any fluid transfer or dispensing application.

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

OPERATOR S MANUAL A

FRL/AirCare Air Controls & Accessories

Compact Cleaning System

Description operation Metering devices VSKH-KR Stage 1 Pressurised lubricant is supplied to the metering device via main line I. The control piston (1

Product Information Report Industrial Hose: Multipurpose Air and Water Hose

OPERATOR S MANUAL

3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

: ENLARGING ADAPTER - joints. Used to connect dissimilar taper joint sizes. Code # Top Outer Bottom Inner Code # Top Outer Bottom Inner

L3 SERIES COMPACT PUMPS

SECTION FIVE INDUSTRIAL LUBRICATIONFITTINGS

Spray Clean 606T-2 Installation Instruction

Cylinder Head Installation - Left Side

Pneumatic Division North America Richland, MI 49083

OPERATOR S MANUAL SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

SPECIAL LIMITED 5 YEAR WARRANTY* JSG Industrial Systems PMV PUMPS & ACCESSORIES Material Dispensing

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

Table of Contents. Page. See Catalog and Product Updates on our Website

AIR HYDRAULIC PUMP SIDE VIEW

1-1/2" DIAPHRAGM PUMP 1:1 Ratio (metallic) with Cone Checks

66M170-XXX-C RELEASED: REVISED: (REV. 05) 1-1/2" DIAPHRAGM PUMP

> Vacuum Brake Standard automotive vacuum brake (NABT)...Nylon air brake tubing, color coded...105

Tubing & Hose Metric. Nylon, Polyurethane, Polyester Reinforced PVC, Metal Braided Rubber, Copper, Double Wall Brazed Steel

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

General Lubrication Products Series

Husky 3275 Aluminum Pumps Air-Operated Double-Diaphragm

Neoprene. Steel or Brass

VACUUM CUPS 2 SECTION 2 VACUUM CUPS 2: EDCO USA.

Control valves, meters and accessories

SECTION SIX. Reels. Introduction

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

SERIES PA PNEUMATIC CYLINDERS FOR VALVE ACTUATION BORE SIZE: 3 1/4 TO 20 RATING: 150 PSIG (1000 KPA)

Pressure Control Valves

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

DEMA Pro-Fill I Sink Dispenser

LF90C thru current printed 7/19/2012 Page 1 of 5

Drill Serial Number Range: LF90C thru current

& Tower for PWM Control. Maximum Application Rates with Two 5.3 GPM Electric Pumps

Certo Chemical Dilution System

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

COUPLINGS. Series Page. Couplings HOSE

Transcription:

SL-33 For dispensing petroleum-based lubricants with a viscosity up to NLGI No. 2 (refer to Design Guide). May be combined in a circuit of Injectors SL-32, SL-V, SL-V XL, SL-1 and/or SL-11. Available in stainless steel SAE 304, for application where environmental conditions are hazardous to carbon steel or in industries preferring stainless steel. SL-33 Output Operating Pressure.001 cu. in..003 cu. in. 1200 psig 3500 psig 1500 psig 200 psig.016 cc.049 cc 83 bar 241 bar 103 bar 14 bar Connections Dimensions Stainless Manifold Injector A B Steel Steel (304) Inlet Outlet in. mm in. mm 83309-1 83715-1 1 1 1 8 29 1 5 8 41 83309-2 83715-2 2 1 7 8 48 2 3 8 60 83309-3 83715-3 3 1 8" O.D. 2 5 8 67 3 1 8 79 83309-4 83715-4 4 1 8" NPTF (F) Tube 3 3 8 86 3 7 8 98 83309-5 5 4 1 8 105 4 5 8 117 83309-6 83715-6 6 4 7 8 124 5 3 8 137 83715-7 7 5 5 8 143 6 1 8 156 83900 83900-9 1 1 8" NPTF (M) Single Injector/No Manifold 83314 83314-9 Single Replacement Injector 1. Injectors, except replacement injectors for manifold, include compression nut and ferrule for tubing ¹ ₈" O.D. as standard. Other outlet connectors for feed line optional. 2. Injectors with manifolds include two mounting clips and screws. 3. Injectors have Nitrile packings (200 F max. / 93 C). Check packing compatibility with synthetic lubricants. 4. Output with indicator cap hand-tightened is.001 cu. in. Maximum output is achieved with two turns at.001 cu. in./turn. 5

SL-32 For dispensing petroleum-based lubricants with a viscosity up to NLGI No.2 (refer to Design Guide). May be combined in a circuit of injectors SL-33, SL-V, SL-V XL, SL-1 and/or SL-11. Available in stainless steel SAE 304, for application where environmental conditions are hazardous to carbon steel or in industries preferring stainless steel. SL-32 Output Operating Pressure.001 cu. in..008 cu. in. 1200 psig 3500 psig 1500 psig 200 psig.016 cc.131 cc 83 bar 241 bar 103 bar 14 bar Connections Dimensions Stainless Manifold Injector A B Steel Steel (304) Inlet Outlet in. mm in. mm 83336-1 83724-1 1 1 1 4 32 1 3 4 44 83336-2 83724-2 2 1 4" NPTF (F) 2 51 2 1 2 63 83336-3 83724-3 3 1 8" O.D. 2 3 4 70 3 1 4 83 83336-4 83724-4 4 Tube 3 1 2 89 4 102 83338 1 1 4" NPTF (M) Single Injector/No Manifold 83337 83337-9 Replacement for manifold injectors 1. Injectors, except replacement injectors for manifold, include compression nut and ferrule for tubing ¹ ₈" O.D. as standard. Other outlet connectors for feed line optional. 2. Injectors with manifolds include two mounting clips and screws. 3. Injectors have Nitrile packings (200 F max. / 93 C). Check packing compatibility with synthetic lubricants. 4. Output with indicator cap hand-tightened is.001 cu. in. Maximum output is achieved with five turns at.0014 cu. in./turn. 6

SL-V 8 3 /4" (222mm) 3 /8" (19mm) 1 1 /4" (32mm) 1 /8" NPTF 13 /32" (10.3mm) Mounting Holes 2 1 /8" (54mm) 3 /8" NPTF (both ends) 1 1 /2" (38mm) A B 1 3 /8" (35mm) For dispensing lubricants compatible with polyurethane seals up to NLGI No. 2 (refer to Design Guide). May be combined in a circuit of injectors SL-32, SL-33, SL-1, SL-V XL and/or SL-11. Each SL-V injector includes a clear polycarbonate protective cap. Output Operating Pressure Connections Material Manifold Injector Inlet Outlet SL-V 1850 psig 6000 psig 2500 psig 1000 psig 3 8" 1 8" 0.015 0.08 Steel 128 bar 415 bar 170 bar 70 bar NPTF(F) NPTF(F) Dimension A Dimension B Type in. mm in. mm 85770-1 One Injector Manifold 1 2 1 /2 63 Single Mounting Hole 85770-2 Two Injector Manifold 2 3 76 85770-3 Three Injector Manifold 3 1 1 /4 32 4 1 /4 108 85770-4 Four Injector Manifold 4 2 1 /2 63 5 1 /2 140 85770-5 Five Injector Manifold 5 3 3 /4 95 6 3 /4 171 85770-6 Six Injector Manifold 6 5 127 8 203 85771 Replacement for manifold injectors 85772 Single injector/no manifold ( 3 8" NPTF(M) inlet) 1. Injector manifolds have 13 32" (10.3 mm) dia. mounting holes for 3 8" bolt. 2. Injectors have polyurethane seals Check compatibility with synthetic lubricants. 3. Injector rated for 180 F (80 C) max. ambient temperature, depending on lubricant used. 4. Injectors include fitting for filling feedlines via alternate outlet port. 5. Output with adjustment screw hand-tightened is.015 cu. in. Maximum output is achieved with five turns at.014 cu. in./turn. 7

SL-V XL High-Output 11 3 /16" (284mm) 1 1 /4" (32mm) 3 /4" (19mm) 1 /8" NPTF 13 /32" (10.3mm) Mounting Holes 2 1 /8" (54mm) 3 /8" NPTF (both ends) For dispensing lubricants compatible with polyurethane seals up to NLGI No. 2 (refer to Design Guide). May be combined in a circuit of injectors SL-32, SL-33, SL-1, SL-V and/or SL-11. Two SL-V XL injectors are required to replace one SL-11 injector. Each SL-V XL injector includes a clear polycarbonate protective cap. 1 1 /2" (38mm) A B 1 3 /8" (35mm) Output in 3 (cc) Operating Pressure Connections Material Manifold Injector Inlet Outlet SL-V XL 0.015 0.305 1850 psig 6000 psig 2500 psig 1000 psig 3 8" 1 8" Steel (0.25) (5.00) 128 bar 413 bar 172 bar 69 bar NPTF(F) NPTF(F) Dimension A Dimension B Type in. mm in. mm 85780-1 One Injector Manifold 1 2 Single Mounting Hole /2 63 85780-2 Two Injector Manifold 2 3 76 85780-3 Three Injector Manifold 3 1 1 /4 32 4 1 /4 108 85780-4 Four Injector Manifold 4 2 1 /2 63 5 1 /2 140 85780-5 Five Injector Manifold 5 3 3 /4 95 6 3 /4 171 85780-6 Six Injector Manifold 6 5 127 8 203 85781 Replacement for Manifold Injectors 85782 Single Injector/No Manifold ( 3 /8" NPTF(M) inlet) Spectrum Adjustment Sleeves: Number Output Ratio from Ratio from Sleeve (10/bag only) in 3 (cc) Minimum Output Maximum Output Color N/A 0.015 (0.25) 1 0.05 NA 85785-1 0.030 (0.50) 2 0.10 red 85785-2 0.045 (0.75) 3 0.15 silver 85785-3 0.060 (1.00) 4 0.20 gold 85785-4 0.075 (1.25) 5 0.25 green 85785-5 0.113 (1.88) 7.5 0.37 black 85785-6 0.150 (2.50) 10 0.50 purple 85785-7 0.188 (3.13) 12.5 0.62 blue 85785-8 0.225 (3.75) 15 0.75 orange 85785-9 0.263 (4.38) 17.5 0.87 brown 85785-10 0.300 (5.00) 20 1.00 yellow 1. Injector manifolds have 13/32" (10.3 mm) dia. mounting holes for 3/8" bolt. 2. Injectors have polyurethane seals Check compatibility with synthetic lubricants. 3. Injector rated for 180 F (80 C) max. ambient temperature, depending on lubricant used. 4. Injectors include fitting for filling feedlines via alternate outlet port. 5. Output with adjustment screw hand-tightened is.015 cu. in. Maximum output is achieved with 20 1 2 turns at.014 cu. in./turn. 8

SL-1 For dispensing lubricants compatible with Viton packings and viscosity up to NLGI No. 2 (refer to Design Guide). May be combined in a circuit of injectors SL-32, SL-33, SL-V, SL-V XL and/or SL-11. Available in stainless steel SAE 316, for application where environmental conditions are hazardous to carbon steel or in industries preferring stainless steel. SL-1 Output Operating Pressure Connections Manifold Inlet.008 cu. in..080 cu. in. 1850 psig 3500 psig 2500 psig 600 psig.131 cc 1.31 cc 127 bar 241 bar 172 bar 41 bar * For complete assembly, you must order stainless steel manifold and corresponding quantity of #84776 Injectors separately. ³ ₈" NPTF (F) Injector Outlet ¹ ₈" NPTF (F) Dimensions Stainless A B Steel Steel (316) in mm in mm 81770-1 239351* One Injector Manifold 1 Single Mounting 2 1 2 63 81770-2 239352* Two Injector Manifold 2 Hole 3 76 81770-3 239353* Three Injector Manifold 3 1 1 4 32 4 1 4 108 81770-4 239354* Four Injector Manifold 4 2 1 2 63 5 1 2 140 81770-5 239355* Five Injector Manifold 5 3 3 4 95 6 3 4 171 81770-6 6 5 23 8 203 81713 Single injector/no manifold, [ 3 8" NPTF (M) inlet] 81713A 84776* Injector Replacement for manifolded injectors 1. Injector manifolds have ¹³ ₃₂" (10.3 mm) dia. mounting holes for ³ ₈" bolt. 2. Injectors have Viton packings. Check compatibility with synthetic lubricants. 3. Injector rated for 350 F (176 C) max. ambient temperature, depending on lubricant used. 4. Injectors include fitting for filling feedlines via alternate outlet port. 5. Output with adjustment screw hand-tightened is.009 cu. in. Maximum output is achieved with eight turns at.009 cu. in./turn. 9

SL-11 For dispensing lubricants compatible with Viton packings and viscosity up to NLGI No. 2 (refer to Design Guide). May be combined in a circuit of injectors SL-32, SL-33, SL-V, SL-V XL and/or SL-1. Available only as single unit with 1 2" NPTF Female inlet. SL-11 Output Operating Pressure.050 cu. in..500 cu. in. 1000 psig 3500 psig 2500 psig 800 psig.82 cc 8.2 cc 69 bar 241 bar 172 bar 55 bar Connections Steel Inlet Outlet 85497 1 1 2" NPTF (F) 1 4" NPTF (F) 1. Injectors have Viton packings. Check packing compatibility with synthetic lubricants. 2. Injector rated for 350 F (176 C) max. ambient temperature. 3. Injectors supplied with fitting for filling feed line via alternate outlet port. 4. Output with adjustment screw hand-tightened is.05 cu. in. Maximum output is achieved with 11 1 /2 turns at.040 cu. in./turn. 10