Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

Similar documents
SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR HYDRAULIC PTO DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG FIRE FIGHTING SYSTEM

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

Darley UHP-HV Diesel Specification 1

DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

PyroLance B 2000 M-G Technical Manual

OPTIONS SLIP-ON FIREFIGHTING UNITS

PRODUCT RELEASE CKMTA12 / 24

HIGH VELOCITY PUMP PUMP END

3.2 UTLI41A AND UTLI46A GENERAL SPECIFICATIONS

Portable Pumps Transportable MaxStream Diesel Floating Pumps Pro Kit Skid and Trailer

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

B Pump Mounting. Page 1 of 7

Car Wash / Pressure Washer

Cartridge Valves Technical Information. Spreader Valves. Spreader Valves SCHEMATIC MODEL PRESSURE FLOW* WEIGHT SPR-2FFL12 SPR-2FFLC12 SPR-2FFLW86

Priming Systems Installation Instructions

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 13 Pumps and Accessory Equipment Revised

PUMPERS CUSTOM AND COMMERCIAL. Discover Innovation. Experience Technology.

Custom Vac 822 Hydrovac with the following specifications (Tri Drive Mounted):

HOT WATER PRESSURE WASHER BREAKDOWN

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

FOR YOUR SKID SPRAYER?

Solenoid Operated Block Valves A2800 Series

SECTION D Engine 6.0L Diesel

Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

Pump Mounting and Drive Arrangements

32 quarts Transmission Allison HT 740 Automatic Fluid

UNIVERSAL, INDEPENDENT DUAL SYSTEM HYDRAULIC TEST STAND


Fog Misting System. Misting systems have been used in outdoor cooling applications for decades. These systems can provide outdoor cooling

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

2 YEAR WARRANTY HOSE REELS. reelmaster Series heavy duty, quality hose reel engineered to save space

(800)

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

The EL-FHT is a. The FH-series line of fire hose testers, offers testing. Pressure Wands Fire Hose Testers Hose Restraints Hand Pumps MINI HOSE TESTER

PRODUCT OVERVIEW. Our Mission:

UNIVERSAL ATOMIC DIESEL MODEL (16 H.P.) PARTS MANUAL. Universal Motors

System Models 3020/3040/3060 INSTALLATION AND OPERATION MANUAL. Unit Serial Number

M-B Companies, Inc. Specification. Model 155 PLS-155. Palletized Striper. High Pressure Airless. 2 x 55 Gallon Drum. Standard Rev. 2 January 11, 2008

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

DARLEY PUMPS CAF SYSTEMS DAVEY PORTABLES DIESEL PORTABLE FAST ATTACK SKIDS

(800)

Albemarle County Virginia Brush Fire Truck Specification

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

REPAIR MANUAL AFX8010

OWNER S MANUAL. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/5.5 HP Engine, 4-Roller Pump & Deluxe Handgun) Assembly Instructions

KJ Motor/Pump Assembly. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

FMC COMMANDER-15 CONTAINER/PALLET LOADER

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

5200 ITH Specifications and Features

MITSA INTERNATIONAL P.O.

AccuMax 3060 Multi-Point Detailed Specifications

05 Water Pressure Systems INTRODUCTION

CALIFORNIA Proposition 65 Warning:

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

MODEL NO. UTL-60-7

The TR-Series are large volume,

Turn On Your EnPak. EnPak.com. Turn Off Your Truck... EnPak Mechanic Series. A revolutionary, fully integrated power system for mechanic s trucks

PUMP ACCESSORIES. Pump Accessories 40,000 PSI

PARTS LIST FOR CW ME3 (AFTER SERIAL # )

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Electric Fuel Pump FPM

MODEL NO. TSSK GALLON SKID-MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Engine Diagrams

KJ Motor/Pump Assembly. Jetter. Printed in U.S.A. Ridge Tool Company/Elyria, Ohio, U.S.A.

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

ERWC RM Shown with Optional Akron Brass Junction Box and Guide Roller

MODEL: PX10-200ET70 / PX15-280ET140

AMERICAN EAGLE COMPRESSOR AND ACCESSORIES CATALOG. Your Contact: Telephone:

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

LIQUIDYNAMICS 1:1, 3:1 and 5:1 RATIO AIR OPERATED OIL PUMPS

Table of Contents WARRANTY

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

FIRE KNAPSACK FIRE RESPONSE UNITS FIRE TRAILERS. Fire Fighting. Pages Designed to perform better.

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

DIAMOND P R O D U C T S

Sprague Air Driven Pumps, Gas Boosters & Power Units

Sullair: An Industry Leader

EXPLODED VIEW SERVICE MANUAL PRESSURE WASHER PSI Models Rev. 08/12. (Reversed View) (Reversed View) WARNING

2017 Price List Foam proportioning base pump, 3.3 gpm, 12V $6, G

EnPak. Turn Off Your Truck Turn On Your EnPak. A revolutionary, fully integrated power system for work trucks

Commercial Traditional Engine 1250 GPM Side Mount Pump Rating 1200 Gallon - Stainless Body

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

INSULATED TELESCOPING AERIAL DEVICE SPECIFICATIONS Van Mounted 31July2002

Transcription:

== B-2000 M-P, PTO, Manual - 2013.002 11/26/13 == SPECIFICATIONS FOR PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P 1

SPECIFICATIONS FOR FIRE FIGHTING SYSTEM HIGH PRESSURE FIRE FIGHTING SPECIFICATIONS Scope and General Design Requirements A fire-fighting system shall be provided for offensively attacking a fire. The high pressure fire-fighting system shall allow the operator to attack fire from a safe position. The system shall be extremely effective in fire attack operations with limited water supplies. Components and Base Plate Design The fire-fighting system shall consist of: Hydraulic Drive Package (Pump, Motor, Reservoir, Cooler, Control Valve)(PTO supplied by fire truck OEM) Water pump: High pressure positive displacement piston pump Hose Reel: Ultra-high pressure hose reel and attack hose Nozzle: Manually operated ultra-high pressure pistol grip style fog nozzle The major components shall be assembled on a removable assembly. The entire system shall be designed to be a quickly installed or removable module. Performance Capabilities The fire-fighting system shall be tested and proven to be highly effective in the following scenarios: Wildland, grass, and brush fire applications Automobile and truck fires Limited structural fires Confined or concealed space fires Limited industrial fires Shipboard and marine firefighting Military fire-fighting applications Container fires ENCLOSURE MOUNTING The fire-fighting system shall be packaged in a self-supporting framework with dimensions of 36 (915 mm) wide, 24 (610 mm) deep, and 26 (660 mm) high. The mounting assembly shall be powder coated and shall be designed to contain the specified major components of the system. ULTRA-HIGH PRESSURE FIRE PUMP SPECIFICATIONS 2

The fire-fighting system shall be equipped with a heavy duty ultra-high pressure plunger type positive displacement fire pump. The pump shall have the following features: Pump rating: 20 GPM @ 2,200 PSI (80 LPM @ 150 bar) System operational rating: 20 GPM @ 1,400PSI (80 LPM @ 100 bar) Brass Manifold Stainless Steel Check Valve Stainless Steel Plunger Rods Bronze Connecting Rods Tapered Roller Bearings Solid Ceramic Plungers Heavy Duty Flat Base High Pressure Seals Heat Treated Crankshaft HYDRAULIC DRIVE SYSTEM SPECIFICATIONS The hydraulically driven ultra high pressure water pump shall be controlled by a PTO that is activated on the pump control panel via the master PTO switch. The hydraulic drive motor shall be engaged via a pressure compensating hydraulic pump flow control switch which will activate when water flow in the fire pump circuit is sensed. This allows the variable speed hydraulic drive pump to spool up to maximum flow regardless of engine RPM with high idle being the starting point. If the flow condition in the water circuit is stopped it will the pump will be put into standby mode that will allow the hydraulic pump to flow 1 GPM @2400PSI until the situation is reversed. As soon as water begins to flow again through the UHP fire pump, the demand on the hydraulic drive pump will return the system to pumping the full rated hydraulic pump capacity regardless of engine RPM. The system shall: 1. Reduce engine RPM when the pump is in by-pass. 2. Prolong pump life by reducing potential heat build-up while the pump is in by-pass. 3. Allow the PyroLance system to be shut down in case of emergency by activating the Master/Emergency stop switch. 4. Allow rapid on/off throttle response eliminating pressure control delays when the PyroLance system is in operation. Hydraulic drive system shall consist of the following components (supplied by PyroLance, except the PTO and Hydraulic Motor): Hydraulic Motor 3

40 gallon (152 L) Hydraulic Reservoir Hydraulic Cooler Thermostat Hydraulic Pump* PTO * The PTO and Hydraulic Pump shall be supplied and installed by the apparatus OEM truck builder. The PTO ratio and coupling shall be approved by PyroLance prior to the installation of the unit. The system shall be capable of delivering full rated output at apparatus high idle rpm. ELECTRIC SUPPLY CABLE AND CONNECTION The unit shall be powered by the chassis power system. There shall be a 12V+ power stud, and a ground stud provided for the OEM / installer to power the system. The OEM / installer shall be responsible for supplying the power to the unit with a circuit breaker. INSTRUCTIONS AND LABELING A fire-fighting pump instruction nameplate and necessary warning labels shall be installed on the assembly. (English language) PANEL LIGHT The pump control panel shall be provided with an LED 12 volt light with switch. PUMP CONTROL PANEL The control panel shall be ergonomically designed and operator friendly. The panel shall be labeled and installed to be easily visible from the operator s position. The following instruments and controls shall be installed: Master electrical switch Emergency stop (red) switch Reel discharge control valve Control panel light and switch One (1) UHP pressure gauge Tank to pump open/closed switch PLUMBING The fire-fighting system shall be plumbed with high pressure hydraulic type hose, plumbing and fittings. This shall include double wire braided high pressure hoses of various sizes, zinc plated steel hose ends, and plated steel hydraulic fittings. The threads shall be male and female NPT, JIC and SAE O-ring style in various sizes. Rigid plumbing shall be in zinc plated steel piping with pipe fittings of zinc plated steel. BYPASS UNLOADER VALVE 4

The ultra-high pressure plumbing system shall include a bronze adjustable by-pass unloading valve set for the proper working pressure of the system. The valve shall unload the excess pressure to the intake side of the pump. PRESSURE SAFETY, EASY START, THERMAL RELIEF VALVE The ultra-high pressure plumbing system shall include the following devices: e.) One (1) pressure safety relief valve which shall relieve water pressure to atmosphere; set at a slightly higher pressure than the unloading valve. f.) One (1) thermal relief valve which shall open if water temperatures exceed 145 F (62 C) degrees; designed to protect the pump from high temperature conditions and relieve the water to atmosphere. g.) One (1) EZ start valve. INTAKE FILTER A 1-1/4" (31 mm) water filter with 32 mesh stainless steel screen shall be installed in the water supply line to the fire pump. The filter shall be accessible for cleaning the screen. ELECTRICAL WIRING Necessary low voltage automatic circuit breaker protection shall be provide where required. Wiring shall be stranded copper automotive type, sized for the appropriate electrical load. Exposed wiring shall be protected with convoluted split plastic loom; such looms shall be mechanically secured. Wiring shall be run in protected areas or enclosed in metal panels where subject to mechanical injury. Electrical connections and termination of wiring shall be within weather proof plastic enclosures with waterproof strain reliefs and connectors. NO WATER TANK SUPPLY LINE No tank to pump valve shall be used with the system. Water shall be constantly supplied to the UHP pump. DISCHARGE PRESSURE GAUGE One (1) 2.5 (62 mm) liquid filled pressure gauge shall be installed from the discharge side of the ultra-high pressure fire pump, with the gauge mounted on the pump panel. THROTTLE CONTROL GOVERNOR (OEM SUPPLIED) Once the PyroLance system is engaged the engine RPM shall be controlled by an electronic throttle control governor via the wireless remote control nozzle, which shall automatically increase engine speed to 1,450 RPM when actuated, and when released return the engine speed to idle. The electronic throttle control governor is an engine type specific part and shall be supplied and fitted by the OEM in consultation with the specific engine/chassis manufacturer. The electronic throttle control governor shall be interfaced with the engine electronic control module (ECM) and will be active once the PyroLance system is engaged and master/emergency stop switch is activated on the PyroLance control panel. 5

The system shall: Reduce engine RPM when the pump is in by-pass resulting in reduced engine wear. Prolong pump life by reducing potential heat build-up while the pump is in by-pass. Reduce fuel consumption because the engine is not continually running at full RPM. Allow the PyroLance system to be shut down in case of emergency by activating the Master/Emergency stop switch. Allow the hydraulic bypass unloader valve to go into by-pass mode and drop the hydraulic system pressure to 300 PSI (20 bar) or less when the water flow control valve is closed. Allow rapid on/off throttle response eliminating pressure control delays when the PyroLance system is in operation. ELECTRIC REWIND HOSE REEL ULTRA-HIGH PRESSURE One (1) ultra-high pressure steel hose reel shall be installed with a maximum capacity of 200' of 3/4" hose per reel. The reel shall have a leak proof ball bearing swing joint, electric 12 volt rewind provisions. The reel system shall be designed for a 2,000 PSI (135 bar) working pressure. The reel shall be painted red. Each reel shall be equipped with a locking pin assembly. The high pressure hose reel shall be supplied by a 1/2 (12 mm) hydraulic type wire braided flexible hose line. One (1) push button electric rewind control shall be installed near the reel. The wiring from the hose reel electric box shall be protected with conduit or loom. The hose reel shall be equipped with a electrical wiring junction box of plastic construction with a sealed cover assembly. The box shall house the reel solenoid, circuit breaker, and electrical wiring for the rewind control circuit and electric rewind motor power supply. The electrical supply shall be sized for the reel motor for both positive and neutral cables. The electrical supply wiring shall be supplied from the main electrical supply box for high pressure pump skid or module. The supply line to the reel shall have a quick disconnect connection at the main electrical supply box. One (1) stainless steel hose roller assembly shall be supplied with reel for protection of the hose during hose removal and rewind operations. REEL MOUNTED ULTRA-HIGH PRESSURE HOSE 150 foot (45 m) length x 3/4" (19 mm) hose shall be installed with threaded couplings. The hose shall have a working pressure of 3,125 psi (215 bar). The hose reel(s) shall be installed by the OEM. NOZZLE -- ULTRA-HIGH PRESSURE One (1) 20 GPM (80 LPM) ultra-high pressure pistol grip fog nozzle shall be provided for the high pressure fog reel. FACTORY TESTING PRIOR TO SHIPMENT The entire pump and the plumbing system shall undergo a complete factory test. These test results shall be provided with shipment. 6

CRATING The equipment shall be properly crated, sealed, and protected for shipment. The crate shall be approximately: 48" (1219 mm) wide x 48" (1219 mm) long x 54" (1372 mm) high in size and less than 2,000 lbs. (907 kg) in weight. WARRANTY The PyroLance ultra-high pressure type firefighting system components shall be covered by a one (1) year parts and labor warranty. The installation portion of the warranty shall be covered by the final stage assembler. TECHNICAL MANUAL The ultra-high pressure firefighting system shall be covered by a detailed technical manual covering installation, testing, operation, maintenance, and parts. This manual shall have various levels of warnings and caution notices provided. Paper and electronic portions will be supplied with the apparatus. 7