CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

Similar documents
Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Spring-loaded cover seats against neoprene gasket.

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

EDS / EFS Series Control Stations

EDS / EFS Series Control Stations

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

Division 2 Contender Series Factory Sealed Control Stations

EDS / EFS Series Control Stations

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

Hazardous Factory Sealed Control Devices

Plugs and Receptacles: Hazardous Location

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Push Button. Rocker Arm

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

FACTORY SEALED CONTROLS - INTRODUCTION

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

FACTORY SEALED CONTROLS - INTRODUCTION

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

Areamaster LED Flood/High Bay Luminaires

Motor Starters Hazardous and Non-Hazardous

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Applications. Standard Materials

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Control Stations Hazardous and Non-Hazardous

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Hazardous Duty Applications

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Conduit Bushings for Rigid Metal Conduit and IMC

Condulet Single Gang Cast Device Boxes With and Without Mounting Lugs for Threaded Rigid and IMC Conduit

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Enclosures. Section E

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Applications. Standard Materials. Certifications and Compliances

Junction Boxes Hazardous and Non-Hazardous

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Cable Connectors & Conduit Sealing Bushings

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

EPOXY POWDER COATED COPPER FREE ALUMINUM

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Circuit Breakers Hazardous

General Cable Support Information

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

Applications. Illustrated Features

Cable Connectors & Conduit Sealing Bushings

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

L-1. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit.

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Applications. Standard Materials. Certifications and Compliances

Condulet Cast Device Boxes and Covers Application and Selection

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Transcription:

Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. Applications Designed to prevent arcing of enclosed switches in ignitable atmospheres during connect and disconnect operation of lighting and light power loads. For use in classified areas where ignitable vapors, gases or highly combustible dusts are present. For installation in: Chemical plants Petrochemical plants Refineries Other process industries Features Enclosures have external mounting lugs for ease of mounting. Smooth, rounded integral bushing in each hub protects conductor insulation. Enclosures furnished with internal ground screw. 20 Amp and 30 Amp units available for use with 120-277 Vac. Smooth ground mating surfaces assure flame-tight joint between cover and mounting enclosure. Stainless steel hex head cap screws for attaching cover to mounting enclosure. Choice of front-operating or side rocker arm handle each may be locked in ON or OFF position. Each handle has close-tolerance threaded stainless steel shaft to meet Explosionproof requirements. Enclosures furnished with internal ground screw. Options 1- or 2-gang copperfree (4/10 of 1% max.) aluminum bodies and covers available. Add suffix SA. NPBRKT nameplate mounting bracket to make circuit description/identification easy. Pre-drilled holes in bottom of bracket allow direct mounting to control stations with existing cover bolts. Pre-drilled holes in middle of bracket allow mounting of customer s circuit identification nameplate; epoxy glue may also be used for mounting (phenolic nameplate not included). Bracket eliminates costly field installation of drilling and tapping to accommodate circuit identification nameplate. Brackets fit side-by-side on 2-, 3- and 4-gang boxes and 3-devices. Standard Materials Body and cover: malleable iron Handle: nylon 6/6 Optional nameplate mounting bracket: corrosion resistant stainless steel Standard Finishes Tumbler switches: triple-coat (1) zinc electroplate, (2) chromate, and (3) epoxy powder coat NEC/CEC Certifications and Compliances UL Standards: UL 894, UL 1203 CSA Standards: C22.2 No. 14 culus Listed: E10449 Illustrated Features Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models. Explosionproof Labyrith Switch Used on all 20 Amp models excluding 4-way. Indicates items which are suitable for Class I, Division 2, Group B. See product selection pages for suitable items. 86

Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground. 1-Gang 2-Gang Hub Size (Inches) 20 Amp 120-277 Vac Switch 1/2 1-Pole EDS1129 EDSC1129 1/2 2-Pole EDS118 EDSC118 1/2 3-Way EDS1130 EDSC1130 1/2 4-Way EDS1140 EDSC1140 3/4 1-Pole EDS2129 EDSC2129 3/4 2-Pole EDS218 EDSC218 3/4 3-Way EDS2130 EDSC2130 3/4 4-Way EDS2140 EDSC2140 1 1-Pole EDS3129 EDSC3129 1 2-Pole EDS318 EDSC318 1 3-Way EDS3130 EDSC3130 1 4-Way EDS3140 EDSC3140 30 Amp 120-277 Vac 1 1-Pole EDS3591 EDSC3591 1 2-Pole EDS3593 EDSC3593 1 3-Way EDS3594 EDSC3594 20 Amp 120-277 Vac 1/2 1-Pole EDS1229 EDSC1229 1/2 2-Pole EDS128 EDSC128 1/2 3-Way EDS1230 EDSC1230 1/2 4-Way EDS1240 EDSC1240 3/4 1-Pole EDS2229 EDSC2229 3/4 2-Pole EDS228 EDSC228 3/4 3-Way EDS2230 EDSC2230 3/4 4-Way EDS2240 EDSC2240 1 1-Pole EDS3229 EDSC3229 1 2-Pole EDS328 EDSC328 1 3-Way EDS3230 EDSC3230 1 4-Way EDS3240 EDSC3240 For Aluminum body and cover, add suffix SA. 20 Amp Switches 1 HP at 120 Vac and 2 HP at 240 Vac. 30 Amp Switches 2 HP at 120 Vac or 240 Vac. Contains Factory Sealed Switch; no sealing chamber. Suitable for Class I, Division 2, Group B. 87

Switch Covers and Sealing Chamber/Switch Assemblies. Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw. NE/CEC: Factory Sealed Front Cover/Chamber/Switch Assembly Switch Type 20 Amp 120-277 Vac 30 Amp 120-277 Vac 1-Pole EDSF21Q EDSF31Q 2-Pole EDSF22Q EDSF32Q 3-Way EDSF23WQ EDSF33WQ 4-Way EDSF24WQ Cover/Switch Assembly Switch Type Front Cover Only EFSFR Switch Factory Sealed LAB Switch 1-Pole EDSF12 EFSFR1Q LAB21 2-Pole EDSF12 EFSFR2Q LAB22 EFSFR Switch Front Cover Only 3-Way EDSF34W EFSFR3WQ LAB23W Factory Sealed Switch Only 4-Way EDSF34W EFSFR4WQ Nameplate Mounting Bracket Mount bracket between cover screws and cover. Do not mount bracket between ground joint flame path between cover and backbox. Description Bracket with blank silver/black nameplate for Contender series To order bracket with control station, add suffix NPBRKT to end of catalog number. NPBRKT-CONT To order engraved nameplates, add desired markings after catalog number. Maximum of 2 lines with 12 characters (including spaces) per line. With sealing chamber. 20 Amp Switches 1 HP at 120 Vac and 2 HP at 240 Vac. 30 Amp Switches 2 HP at 120 Vac or 240 Vac. Requires the use of Code recognized sealing method as part of installation. Contains Factory Sealed Switch; no sealing chamber. Suitable for Class I, Division 2, Group B. 88

EDS Mounting Bodies Furnished with Internal Ground Screw. Class I, Division 2, Group B, C, D Type Hub Size (Inches) Malleable Iron Aluminum 1-Gang 1/2 EDS171 EDS171-SA 3/4 EDS271 EDS271-SA 1 EDS371 EDS371-SA 1/2 EDSC171 EDSC171-SA 3/4 EDSC271 EDSC271-SA 1 EDSC371 EDSC371-SA 2-Gang 1/2 EDS172 EDS172-SA 3/4 EDS272 EDS272-SA 1 EDS372 EDS372-SA 1/2 EDSC172 EDSC172-SA Tandem 3/4 EDSC272 EDSC272-SA 1 EDSC372 EDSC372-SA 1/2 EDS177 EDS177-SA 3/4 EDS277 EDS277-SA 1 EDS377 EDS377-SA 1/2 EDSC177 EDSC177-SA 3/4 EDSC277 EDSC277-SA 1 EDSC377 EDSC377-SA For tandem bodies, external seals must be installed within 1.5 meters (5 feet) of each conduit entrance for Class I, Groups C and D. 89

Front Operated Tumbler Switches Front 1-Gang Side Front 2-Gang Hub Size (Inches) A B C 1/2 and 3/4 153.9 (6.06) 173.0 (6.81) 19.1 (0.75) 1 156.7 (6.17) 178.6 (7.03) 25.4 (1.00) NPBRKT Nameplate Mounting Bracket Secure bracket under cover screws of box. Torque cover screws to 35 - lbs. Indicates items which are suitable for Class I, Division 2, Group B. See product selection pages for suitable items. 90