Operating Instructions

Similar documents
7 Lighting Technology

Operating Instructions

Operating Instructions

Pendant Light Fitting IEC

Operating Instructions

Operating Instructions

Linear Luminaire for Fluorescent Lamps

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire with LED

Operating Instructions

Emergency Light Fitting for Fluorescent Lamps Series 6009

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Emergency Luminaire with LED Series EXLUX 6409/1

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Linear Luminaire with LED Series EXLUX 6002

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

7 Lighting Technology

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

LED Linear Luminaire Series EXLUX 6402

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Floodlight Series 6521/4

Linear luminaire with LED Series EXLUX 6002

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Compact Sheet-Steel Light Fittings Series 6114

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Explosion protected terminal boxes type, GHG 72.

K: bracket type. L: pole type

Universal spotlight LED

Floodlight Series 6121

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Compact Sheet-Steel Light Fittings Series 6114/1

7 Lighting Technology

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

Sheet-Steel Light Fittings Series 6014 / 6414

Compact Sheet-steel Emergency Light Fitting Series 6118/1

7 Lighting Technology

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

EWE. Ex de. Cooling fins

OPERATING INSTRUCTIONS

Sheet Steel Emergency Light Fitting Series 6018

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom

INSTRUCTION MANUAL (ATEX / IECEx)

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Floodlight LED Series 6525

Floodlight LED Series 6525

Plug and Socket Devices SolConeX 16 A Series 8570

Operating instructions Solenoid interlock EX-AZM About this document. Content

7 Lighting Technology

Ex UPS standard Series 8265

Operating Instructions Flexdip CYA112

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

A good connection. International approvals.

Gavita HortiStar 1000 DE EU/US

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

ILED Dorado. User Manual

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

INSTRUCTION MANUAL (ATEX / IECEx)

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Linear fluorescent luminaire LED V-CG-S

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Ex m Solenoid Operator Type 0519

ILED Aquarius Illuminated Windsock. User Manual

Floodlight LED Series 6125

EX-REPAIR AND MAINTENANCE RECEPTACLES

Unused flameproof threads for cable glands have to be closed with certified plugs.

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Easy and safe installation

EWE. Cooling fins. Ex de

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Junction box for EKL light

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

IQL Helios Area-/Streetlight. User Manual

Assembly and Operating Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Transcription:

Operating Instructions Pendant Light Fitting >

Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5 6 Transport, Storage and Disposal...9 7 Assembly...9 8 Installation...13 9 Commissioning...15 10 Maintenance...15 11 Accessories and Spare Parts...17 12 Type Examination Certificate (Page 1)...21 13 Declaration of Conformity...23 2 General Information 2.1 Manufacturer R. STAHL Schaltgeräte GmbH Am Bahnhof 30 74638 Waldenburg, Germany Phone: +49 7942 943-0 Fax: +49 7942 943-4333 Internet: www.stahl.de 2.2 Information Regarding these Operating Instructions ID NO.: Publication Code: We reserve the right to make technical changes without notice. 2.3 Symbols Used X Take action: Describes the actions which the user should undertake. Reaction symbol: Describes results or reactions to actions taken. Checklist symbol Commentary symbol: Describes notes and recommendations. Warning symbol: Danger live parts! Warning symbol: Danger hot surfaces! 2 Pendant Light Fitting

General Notes Regarding Safety 3 General Notes Regarding Safety 3.1 Safety instructions for installation and operating personnel The operating instructions contain fundamental notes regarding safety, which must be observed during installation, operation and maintenance. Non-observance can result in a hazard to persons, plant and environment. WARNING Risk due to unauthorised work being performed on the device! There is a risk of injury to persons and material damage. Assembly, installation, commissioning, operation and maintenance must only be performed by authorised personnel who have been trained to do so. Before assembly/commissioning: Read operating instructions. Provide assembly and operating personnel with adequate training. Ensure contents of operating instructions has been fully understood by responsible personnel. The national assembly and installation directives (e.g. EN 60079-14) apply. When operating the device: Keep operating instructions at the place of installation. Observe safety instructions. Observe national safety and accident prevention regulations. Only operate the devices in accordance with its performance data. Maintenance or repair work, which is not described in the operating instructions must not be carried out without prior agreement with the manufacturer. Any damage might impair the explosion protection. Any modifications/alterations which might impair the explosion protection of the devices is not permitted. The devices may only be fitted and used if they are in an undamaged, dry and clean condition. If you have questions: Contact the manufacturer. 3.2 Warning notes In these operating instructions, warnings are sub-divided as follows: WARNING Type and source of danger! Possible consequences. Measures for avoiding danger. They are always identified by the word WARNING and sometimes also have a symbol specifying danger. Pendant Light Fitting 3

Intended Area of Application 3.3 Conformity to Standards The pendant light fitting was designed, produced and tested in accordance with 29001 (ISO 9001). It also conforms to the following directives and standards: X Directive 94/9/EC X EN 60079-0 X EN 60079-15 X EN 50281-1-1 X EN 60598 X EN 60400/IEC 61 X 89/336/EEC Electromagnetic Compatibility 4 Intended Area of Application The pendant light fitting is certified for use in areas, where a gas explosion hazard exists (Zone 2 in acc. with IEC 60079-10) and areas where a dust explosion hazard exists (Zones 21 and 22 in acc. with IEC 61241-1). The pendant light fitting is designed for both indoor and outdoor use. The specified ambient temperature must be strictly adhered to (see Table, Page 6). The maximum surface temperature must be strictly adhered to if used in an area where a dust explosion hazard exists (see Table, Page 6). WARNING Only use device for its intended purpose! The manufacturer s liability and warranty will otherwise be impaired. Only use device in accordance with operating conditions specified. The device must only be used in hazardous areas applications as per these operating instructions. Only use device at permissible ambient temperature. 4 Pendant Light Fitting

Technical Data 5 Technical Data Explosion protection Gas explosion protection E II 3 G EEx nr II T* Dust explosion protection E II 2 D IP 66 T O. max * E II 3 D IP 66 T O. max * * temperature classes and surface temperatures see selection table Certificates PTB 05 ATEX 2045 (Zones 2, 22) PTB 05 ATEX 2043 (Zone 21) Other certificates IECEx Identification marking C 0102 Rated operational voltage U e 230 V, AC ± 10%, 50 Hz, others upon request Observe the data given on the rating plate. Nominal current Type of lamp Power Lampholder I N All-purpose lamp A 200 W 500 W Halogen lamp QT 150 W 250 W 500 W Blended lamp LME 160 W 250 W 500 W Metal halide lamp HIE 70 W 100 W 150 W 250 W 400 W High-pressure sodium discharge lamp Power factor cos p ) 0.9 (compensated) Protection class I (PE-connection) Connection L1 + N for 4 mm 2 stranded copper and 6 mm 2 single wire, via internal terminal block Material Housing material saltwater-resistant aluminium Protective glass temperature-change resistant borosilicate glass Cover seal silicone rubber Glass seal silicone rubber Fixing bracket Stainless steel Outer reflector powder coated galvanized sheet steel / fibre-glass reinforced polyester Wire guard saltwater-resistant aluminium Casing fastener securing screw M 8 (stainless steel) Assembly wall and ceiling mounting, mast mounting, suspended by ringbolts, mounting bracket or pipework Position of normal use pendant mounting or slewing angle (30 and 45 ) HSE 50 W 70 W 100 W 110 W 150 W 250 W 400 W 600 W Mercury vapour lamp HME 125 W 250 W 400 W Induction lamp QL 55 W 85 W 165 W E 27 E 27 E 27 E 27 E 27 E 27 E 27 E 27 E 27 E 27 E 27 special special special 0,87 A 2,27 A 0,65 A 1,10 A 2,10 A 0,65 A 1,17 A 2,17 A 0,95 A 0,78 A 0,88 A 1,55 A 2,10 A 0,77 A 0,44 A 0,70 A 0,72 A 1,80 A 1,40 A 2,10 A 3,10 A 0,70 A 2,22 A 1,96 A 0,26 A 0,40 A 0,70 A Pendant Light Fitting 5

Technical Data Ingress Protection IP 66 Ambient temperature - 20 C... + 40 C - 30 C... + 55 C - 50 C... + 55 C all types for sodium vapour and metal halide lamps for mercury vapour lamps, halogen lamps, all-purpose lamps and blended lamps Wire guard and outer reflector Cable entries Screw-in thread for mast mounted lights can easily be retro-fitted using M 6 screws Certified cable glands with an ingress protection of IP66 minimum must be used (in acc. with 94/9/EC).The number of cable entries depends on the type of mounting. Standard Special 1 1 / 4 BSP, 1 1 / 2 BSP, 3 / 4 NPT, 1 NPT M 25 x 1,5 M 20 x 1,5, others upon request Version Pendant light fitting IEC series size 1 up to 150 W Pendant light fitting IEC series size 2 up to 250 W Pendant light fitting IEC series size 3 up to 600 W Type of Lamp holder Lamp power Temperature classification lamp 1) at T a = 40 C 55 C T O max. at T a = 55 C Weight A E 27 200 W T4 T4 130 C 5,217 QT E 27 150 W T5 T4 121 C 8,900 QT E 27 250 W T4 T3 149 C 8,300 LME E 27 160 W T4 T3 143 C 5,217 HIE E 27 70 W T4 T4 103 C 6,797 HIE E 27 100 W T4 T4 121 C 7,197 HIE E 27 150 W T4 T3 140 C 8,115 HSE E 27 50 W T4 T4 98 C 6,297 HSE E 27 70 W T4 T4 106 C 6,797 HSE E 27 110 W T4 T4 124 C 6,463 HME E 27 125 W T5 T3 142 C 6,463 QL Special 55 W T6 75 C * 5,857 LME 250 W T3 T3 170 C 6,091 HIE 250 W T3 145 C * 9,596 HSE 100 W T5 T4 112 C 10,000 HSE 150 W T4 T4 130 C 9,260 HSE 250 W T3 T3 157 C 9,596 HME 250 W T3 172 C * 8,139 QL Special 85 W T5 86 C * 6,535 A QT LME 500 W T4 T4 T3 T3 T3 T3 137 C 142 C 165 C kg 10,868 HIE 250 W T4 T4 130 C 14,834 HIE 400 W T3 T3 155 C 15,545 HSE 250 W T4 T4 132 C 14,834 HSE 400 W T4 T3 146 C 15,545 HSE 600 W T3 166 C * 18,103 HME 250 W T4 T3 145 C 13,377 HME 400 W T3 153 C * 13,708 QL Special 165 W T6 80 C * 11,189 * at maximum ambient temperature of 40 C Notes: 1) A QT LME HIE HSE HME QL Incandescent lamps Halogen lamp Blended lamps Metal halide lamps High-pressure sodium lamps Mercury lamps Induction lamps (supplied with light fitting) 6 Pendant Light Fitting

Technical Data Dimension drawings (all dimensions in mm) - subject to alterations Dimensions in mm /11 /12 /13 A 277 277 372 B 352 414 514 C 230 230 310 D 353 353 521 E 240 240 329 F 357 423 533 G 180 180 260 H M 8 M 8 M 10 I 358 424 535 J 444 444 715 Ceiling mounting without wire guard 10574E00 10566E00 10564E00 Ceiling mounting with wire guard Ceiling mounting with reflector Dimensions in mm /11 /12 /13 A 277 277 372 B 352 414 514 B1 350 412 517 C 230 230 310 G 180 180 260 H M 8 M 8 M 10 K 20 20 25 L 18 18 22.5 M 208 208 209 N 150 150 200 P 220 220 302 Pendant mounting using ringbolts 10568E00 10569E00 10567E00 Pendant mounting using fixing brakket Pendant mounting using pipework Pendant Light Fitting 7

Technical Data Dimension drawings (all dimensions in mm) - subject to alterations Dimensions in mm /11 /12 /13 A 277 277 372 B2 331 393 498 C 230 230 310 J1 340 367 511 Q 7 7 8 R 250 250 422 S 105 125 160 T 405 466 592 V 105 105 139 X 366.5 366.5 579 Y 427 427 628 Types of mounting 10561E00 10563E00 10562E00 Wall mounting Mast mounting 25 Mast mounting 90 11415E00 Ringbolt mounting Ceiling mounting Fixing bracket 11416E00 11417E00 11418E00 11419E00 11420E00 Wall mounting Mast fitting 25 Mast fitting 90 8 Pendant Light Fitting

Transport, Storage and Disposal 6 Transport, Storage and Disposal Transport Shock free in its original carton, do not drop, handle with care. Storage Store in a dry place in its original packaging Disposal Ensure that all components are disposed of in an environmentally friendly manner, in accordance with legal regulations. 7 Assembly 7.1 Fitting the fixture The light fitting is delivered in component form, i.e. the light fitting does not need to be disassembled to fit the fixture. Wall mounting Feed the connection cable through the corresponding cable entry and through fixture. Secure fixture by means of four screws (see dimension drawing). 11421E00 Ceiling mounting Feed the connection cable through the corresponding cable entry and through fixture. Secure fixture by means of two screws (see dimension drawing). 11422E00 Pendant Light Fitting 9

Assembly Fixing bracket mounting Secure fixing bracket with the desired pivoting range to fixture by means of four screws. Feed the connection cable through the corresponding cable entry. 11423E00 Ringbolt mounting Screw two ringbolts into fixture. Secure the fixture (e.g. with chains) to the ceiling. Feed the connection cable through the corresponding cable entry. 11424E00 10 Pendant Light Fitting

Assembly Mounting the mast fitting Feed the connection cable through the mast. Feed the connection cable through the fixture. Insert the adapter between mast and fixture and secure it by means of screws. Screw the mast fitting to the mast (mast screw-in thread). Tighten screw. 11425E00 7.2 Mounting the body of the light fitting Hook the body of the light into the fixture (1). Pivot the body of the light against the fixture (2). Tighten torque screw (M8) (3). 11426E00 Pendant Light Fitting 11

Assembly 7.3 Fitting the wire guard Fit wire guard, from below, over the glass and secure the retaining chain. Secure the wire guard with two screws. 11427E00 7.4 Mounting the reflector WARNING Danger if mounted incorrectly! Risk of material damage. Ensure that the plate (item 4) is correctly inserted! Loosen screw and remove plate (1). Fit reflector to glass from below (2). 11428E00 12 Pendant Light Fitting

Installation Secure reflector with two screws (3). Turn plate, press it against glass and tighten screw (4). 11429E00 8 Installation WARNING Danger from live parts! Risk of serious injury. All connections and wiring must be disconnected from the power supply. Secure connections against unauthorised re-connection. 8.1 Opening of light fitting Loosen the torque screw (M8) (1). Pivot the body of the light carefully from the fixture (2) and allow it to hang in this position. 11430E00 Pendant Light Fitting 13

Installation 8.2 Mains Connection Choke and starter are wired according to the type of lamp fitted when delivered. No further installation work is necessary. 11431E00 Fit silicone sleeves provided (2 or 4 off) over the conductors L and N. Connect conductors to corresponding terminals and secure them (1). The protective earth conductor is factory fitted to the PE connection on the lid of the cover. Secure the PE conductors, from lid and connection cable, to the cover (2). Close off the cable entry (3). Route and secure connection cable, in such a way, that it can not be pulled out. 8.3 Closing of light fitting Pivot the body of the light fitting against the fixture (1). Tighten the torque screw (M8) (2). 11432E00 14 Pendant Light Fitting

Commissioning 9 Commissioning Before commissioning Check that no cable connections are loose. Cable glands used must have an ingress protection class of IP 66 minimum and conform to data given in Chapter 5, Technical Data. Inspect the cover for damage. Inspect the cover for foreign bodies (screws, nuts, tools, etc.). Note nominal voltage. Ensure that all unused cable glands and entries are blanked off. Check lamp is fitted correctly. Check light is ignition protected. Subsequently check, that the seal is positioned under the screw-in plug. During operation The pendant light fitting can be switched ON or OFF during operation. These are the only operating states. 10 Maintenance WARNING Hot surfaces! Danger of burning hands. Allow the casing, protective glass and lamp to cool down for approx. 15 min. before touching. WARNING Danger from live parts! Risk of serious injury. All connections and wiring must be disconnected from the power supply. Secure connections against unauthorised re-connection. 10.1 Replacing lamp WARNING Danger if mounted incorrectly! Risk of material damage. Make sure the plate is correctly positioned: Mounting without reflector: see page 16, item 5 Mounting with reflector: see page 13, item 4 Pendant Light Fitting 15

Maintenance Remove the screw and remove the plate (1) from the glass. Unscrew the protective glass in an anti-clockwise direction and remove it (2). 11433E00 Place the protective glass carefully to one side. Unscrew and remove defective lamp (3). Select new lamp, which conforms with the circuit and screw it in (3). Screw in protective glass hand tight in a clockwise direction (4). Press plate against glass and tighten screw (5). Check light is ignition protected. Subsequently check, that the seal is positioned under the screw-in plug. 11434E00 16 Pendant Light Fitting

Accessories and Spare Parts 10.2 Regular Maintenance Work Refer to corresponding national regulations (e.g. IEC/EN 60079-17) for the type and scope of tests. The maintenance intervals must be chosen, such that the occurrence of deficiencies, anticipated in the system, can be avoided. The following items must be checked as part of the maintenance schedule: X Check that no cable connections are loose. X Inspect device for visible signs of damage. X Check that permitted temperatures, in accordance with EN 60079-0, are adhered to. X Check that the device is functioning correctly. X Check that the light is ignition protected. X After checking the iginition protection, check, that the seal is positioned under the screw-in plug. 10.3 Cleaning X Clean with a cloth, brush, vacuum cleaner or similar items. X When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching cleaning agents. X Never use aggressive cleaning agents or solvents. 11 Accessories and Spare Parts Designation Illustration Description Order number Weight kg Power Lampholder Voltage Luminous flux All-purpose lamps A 200 W E 27 230 V 3100 Im 5126250 0,080 04958E00 500 W 230 V 10000 Im 4609960 0,150 Halogen lamps QT 150 W E 27 230 V 2550 lm 4646120 0,075 05355E00 230 W E 27 230 V 4200 Im 4616400 0,080 500 W 230 V 10000 Im 4616410 0,132 Bblended lamps LME 160 W E 27 230 V 3150 lm 4616660 0,082 04963E00 250 W 230 V 5500 lm 4611100 0,220 500 W 230 V 13000 lm 4611110 0,300 Metal halide lamps HIE 04963E00 70 W E 27 230 V 6500 Im 100 W E 27 230 V 8000 Im 4637750 0,100 4637760 0,420 150 W E 27 230 V 12000 Im 4637770 0,110 250 W 230 V 20000 Im 4616500 0,195 400 W 230 V 31500 Im 4616520 0,284 Pendant Light Fitting 17

Accessories and Spare Parts Designation Illustration Description Order number Weight kg High-pressure sodium lamps HSE 50 W E 27 230 V 3500 lm 4646200 0,075 70 W E 27 230 V 6000 Im 4618880 0,074 04963E00 110 W * E 27 230 V 8000 Im * to operate without starter 100 W 230 V 9500 Im 150 W 230 V 15000 Im 250 W 230 V 28000 Im 400 W 230 V 48000 Im 600 W 230 V 90000 lm 4646080 0,290 4647750 0,081 4616670 0,285 4616680 0,200 4616700 0,340 4637780 0,220 05355E00 High-pressure sodium lamps HSE (TwinArc) 04963E00 50 W E 27 230 V 3600 Im 70 W E 27 230 V 6000 Im 4647640 0,070 4647650 0,074 100 W 230 V 9500 lm 4647660 0,100 150 W 230 V 17000 lm 4647670 0,200 250 W 230 V 32000 lm 4647680 0,250 400 W 230 V 55000 lm 4647690 0,290 Mercury lamps HME 125 W E 27 230 V 6500 lm 5126080 0,080 04963E00 250 W 230 V 20000 Im 5126090 0,210 400 W 230 V 31500 Im 5126100 0,400 Induction lamps QL 55 W Special 230 V 3500 lm 5126760 0,270 85 W Special 230 V 6000 lm 5126770 0,260 10579E00 165 W Special 230 V 12000 lm 5126780 0,300 Safety glass temperature-change resistant borosilicate glass with screw-in thread for /11 and 6480/11 648080580010 3,370 10572E00 for /12 and 6480/12 648080580210 4,400 for /13 and 6480/13 648080580310 6,600 Wire guard salt water resistant aluminium, with fittings for /11 and 6480/11 648080140010 0,250 10571E00 for /12 and 6480/12 for /13 and 6480/13 648080140210 0,300 648080140310 0,600 Standard reflector powder coated galvanised sheet steel, with fittings for /11, /12 and 6480/11, 6480/12 648080580020 2,250 10288E00 fibre-glass reinforced polyester, with fittings for /13 and 6480/13 648080580320 5,500 Reflector 30 made of glass fibre reinforced polyester, with mounting parts 06249E00 for /11 and /12 for 6480/11 and 6480/12 648080580030 0,600 18 Pendant Light Fitting

Accessories and Spare Parts Designation Illustration Description Order number Weight kg Mounting bracket stainless steel, with fittings for /11, /12 and 6480/11, 6480/ 80180010 1,200 12 for /13 and 6480/13 80180310 1,500 10570E00 Cover for ceiling mounting 10580E00 The light is ceiling mounted by means of lugs, which are on the cover. A mounting bracket or ringbolts can be retrofitted to the cover (must be ordered as accessories). with thread M 20 x 1.5 for /11 and for /12 80050020 1,264 with thread M 20 x 1.5 for /13 80050320 1,850 with thread M 25 x 1.5 for /11 and for /12 80050010 1,264 with thread M 25 x 1.5 for /13 80050310 1,850 Cover for wall mounting with thread M 20 x 1.5 for /11 and for /12 648080050080 2,137 10573E00 with thread M 20 x 1.5 for /13 648080050380 3,600 with thread M 25 x 1.5 for /11 and for /12 648080050070 2,137 with thread M 25 x 1.5 for /13 648080050370 3,600 Cover for mast mounting 25 with thread 1 1 / 2 BSP for /11 and for /12 648080050150 1,113 10577E00 with thread 1 1 / 2 BSP for /13 648080050450 2,300 with thread 1 1 / 4 BSP for /11 and for /12 648080050160 1,113 with thread 1 1 / 4 BSP for /13 648080050460 2,300 Cover for mast mounting 90 with thread 1 1 / 2 BSP for /11 and for /12 648080050170 1,689 10578E00 with thread 1 1 / 2 BSP for /11 and for /12 648080050470 3,000 with thread 1 1 / 4 BSP for /11 and for /12 648080050180 1,689 with thread 1 1 / 4 BSP for /11 and for /12 648080050480 3,000 Cover for pipework mounting with thread NPT 3/4 for /11, /12 and for 6480/11, 6480/12 648080050050 0,978 10581E00 with thread NPT 3/4 for /13 and for 6480/13 648080050360 1,400 with thread NPT 1 for /11, /12 and for 6480/11, 6480/12 648080050060 0,978 with thread NPT 1 for /13 and for 6480/13 648080050350 1,400 Ringbolts M8, direct mounting in insert nuts, 1 pair 6000803900 0,056 M10, direct mounting in insert nuts, 1 pair 6050801900 0,200 05378E00 Pendant Light Fitting 19

Accessories and Spare Parts Designation Illustration Description Order number Weight kg Cable entries in moulded material, series 8161 8161/5-M 20-13 1 piece 8161077010 0,012 05864E00 8161/5-M 20-13 50 piece 8161025030 0,600 8161/5-M 25-17 1 piece 8161078010 0,016 8161/5-M 25-17 50 piece 8161026030 0,850 Sealing plugs 04840E00 moulded, series 8290 8290/3-M 20 x 1.5 1 piece 8290008590 0,004 8290/3-M 20 x 1.5 100 piece 8290045590 0,600 8290/3-M 25 x 1.5 8290/3-M 25 x 1.5 1 piece 100 piece 8290009590 0,006 8290046590 0,800 Special wrench For tightening cable glands and cap nuts 05263E00 For cable glands Thread size Packing unit M 20 x 1.5 1 5986140 0,132 Manual ignition protection test device for testing ignition protection of EEx nr ignition protected enclosures. 9400603680 0,730 11006E00 20 Pendant Light Fitting

Type Examination Certificate (Page 1) 12 Type Examination Certificate (Page 1) Pendant Light Fitting 21

Type Examination Certificate (Page 1) 22 Pendant Light Fitting

Declaration of Conformity 13 Declaration of Conformity Pendant Light Fitting 23

Declaration of Conformity 24 Pendant Light Fitting