DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

Similar documents
DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

DAC - Conical Diffuser. Halton DAC. Conical diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

ULA - Valve. Halton ULA. Valve

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

REK, LEK, ROK and LOK

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

HGPL HOSPITAL GRADE LAMINAR FLOW COMMON PLENUM

For installation into ductwork

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Ceiling swirl diffusers

FlowAir CATALOG.

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

REK, LEK, ROK AND LOK

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

Ceiling and wall HEPA filter units

SINGLE DUCT TERMINAL UNITS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

USS - External Louvre. Halton USS. External Louvre

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

Ceiling swirl diffusers with perforated face plate

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

Halton Rex 600 RE6 - Adaptable active chilled beam

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

ILO, OLO, OLE and OLOi

Slot diffusers, Round duct diffusers. IMP Klima

CRITICAL ENVIRONMENT DIFFUSERS

Exhaust air diffuser HPKH + Plenum box ATTS

Ceiling swirl diffusers

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

Ceiling swirl diffusers

Particle Filter Box Model FKF

INDEX. Chapter3. air master. Linear Bar Grilles

Technical information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

VOLUME CONTROL / REGULATING DAMPERS

Ceiling swirl diffusers with perforated face plate

Conical diffuser KHAA TECHNICAL DATA

LFDCX LAMINAR FLOW DIFFUSER WITH INTEGRATED HEPA FILTER

Shenzhen Xiangnan High-Tech Purify Equipment Co., Ltd

Particle Filter Box FKU

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

ACCESSORIES FOR DUCT FANS

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

ceiling swirl diffuser Model DQJA / DQJR

1 of 8. Air Solutions Sdn. Bhd. Euro Carb. Box Type Chemical Filter

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PANEL FILTER PREFILTER MSKP T. Replacement for 1 x 8258

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Splash-proof Terminal HEPA Filter

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

Ceiling diffuser 4DE

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

WALL VENTILATION GRILLES CBP

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers Type RN

Ducted HEPA filter units for highly sensitive areas

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

Ceiling diffuser 4DF

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Halton PRL Plenum for grilles

MODULAR COLD ROOMS PRICE LIST wersja

TH Series UL 900 Class 1, Factory Mutual Approved, Truly Separatorless Filter Modules

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Catalog Swirl diffuser DAL 358

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

Ceiling impulse diffuser Model PIL

COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter. Fresh Air Freed of Floating Materials

Compact Grille Model KG

Transcription:

DHL HEPA terminal filter diffuser Low turbulent flow diffuser (LTF), also suitable for exhaust Installation flush to the ceiling, also suitable for wall installation A measurement access through the diffuser plenum for pressure measurement and aerosol test Easy filter change and cleaning through the openable diffuser panel Low unit height Fixing brackets for easy installation of the product Sizes 595 and 670 adapted for installation in modular suspended ceilings HEPA filters H11 and H14 available as standard Powder coated finishing, standard colour RAL9010 Accessories Filters should be ordered separately. H11 with polyurethane seal H14 with polyurethane or gel seal Pre-filter G4 for exhaust applications MATERIAL AND FINISHING PART MATERIAL NOTE Casing Galvanized steel Front panel Perforated steel Coupling sleeve Galvanized steel Filter brackets Acid proof steel Guide pins Polyethylene terephthalate (PET) Fixing brackets Galvanized steel Finishing Paining, standard colour RAL 9010 Special colours available 284

DIMENSIONS 2 1 D H 2 1 D 152 H P DHL ØD H 1 2 365-1 159 365 210 336 320 392 595-1 199 595 210 554 473 545 670-1 314 670 210 641 625 697 315 418 313 6 290 98 2 L 152 8 223 8 152 H1 DHL ØD H H1 1 2 365-2 159 365 360 252 336 320 392 595-2 199 595 400 272 554 473 545 670-2 249 670 450 297 641 625 697 315 418 313 6 DHL L 1 2 365-3 199 365 336 320 392 595-3 399 595 554 473 545 670-3 499 670 641 625 697 60 1 8 285

4 3 2 1 Function Air is filtered and supplied with low turbulence into the space or exhausted through the perforated front panel of the unit. Installation 1 Front panel 2 Filter 3 Plenum 4 Installation brackets The diffuser is connected directly to the duct by screwing or by riveting. The connection is sealed as leakproof with an appropriate method. The diffuser is installed either fast into or hanged from the ceiling with M8 drop rods using movable fixing brackets. Alternatively the diffuser is installed fast to the wall construction. Open the front panel be gently pulling from the openings on side of the front panel. Front panel will hang from the hinges. Detach the panel from the hinges. Clean the diffuser plenum before the filter installation Install the filter into diffuser. The guide pins ensure the exact location of the filter. Turn the brackets below the filter and tighten them evenly. Scan the filter for bypass leakages and correct the tightness, if necessary Reattach the front panel by pushing it until the springs lock. Adjustment The airflow adjustment and shut off will be made with PTS/A damper in the ductwork (tightness class 4 EN 1751). The pressure drop of the clean filter can be used as a reference for airflow rate with a reasonable accuracy. If there is no measurement unit available, Halton MDA or MSD may be used as measurement unit. Constant or variable air flow & shut off The airflow is adjusted with the aid of electrical airflow management damper HFB/G in the ductwork. Depending on the application the damper is ordered either with constant or variable air volume settings. See details of ordering from HFB documentation. 286

Filters Laminar flow filter, class H11 and H14 MATERIALS PART MATERIAL Specification Strong frame and construction with steel protection grid Filters available in classes H11, H14 Aluminium frame, foamed polyurethane or gel gasket Protection screens composed of stretched steel grid with white painting Filter Folded class fibre paper Frame Aluminium Sealant Polyurethane or gel Operating range Continuous operating temperature 80 C Relative humidity max. 100 % Final pressure drop recommended for filter replacement 400 Pa Maximum allowable pressure drop 600 Pa FILTER SELECTION PRODUCT CODE CLASS SIZE GASET DHL 365 DHL 595 DHL 670 CLP-LF-AL-305-305-68-0-H11-GF-P H11 305 x 305 x 68 PUR foam X CLP-LF-AL-457-457-68-0-H11-GF-P H11 457 x 457 x 68 PUR foam X CLP-LF-AL-610-610-68-0-H11-GF-P H11 610 x 610 x 68 PUR foam X CLP-LF-AL-305-305-68-0-H14-GF-P H14 305 x 305 x 68 PUR foam X CLP-LF-AL-457-457-68-0-H14-GF-P H14 457 x 457 x 68 PUR foam X CLP-LF-AL-610-610-68-0-H14-GF-P H14 610 x 610 x 68 PUR foam X CLP-LF-AL-305-305-80-G-H14-GF-P H14 305 x 305 x 80 Gel X CLP-LF-AL-457-457-80-G-H14-GF-P H14 457 x 457 x 80 Gel X CLP-LF-AL-610-610-80-G-H14-GF-P H14 610 x 610 x 80 Gel X 287

DIMENSIONS FILTER TYPE FILTER CODE H D H11 with polyurethane sealant CLP-LF-AF-305-305-68-0-H11-GF-P 305 305 68 CLP-LF-AF-457-457-68-0-H11-GF-P 457 457 68 CLP-LF-AF-610-610-68-0-H11-GF-P 610 610 68 H14 with polyurethane sealant CLP-LF-AF-305-305-68-0-H14-GF-P 305 305 68 CLP-LF-AF-457-457-68-0-H14-GF-P 457 457 68 CLP-LF-AF-610-610-68-0-H14-GF-P 610 610 68 H14 with gel sealant CLP-LF-AF-305-305-80-G-H14-GF-P 305 305 80 CLP-LF-AF-457-457-80-G-H14-GF-P 457 457 80 CLP-LF-AF-610-610-80-G-H14-GF-P 610 610 80 TECHNICAL VALUES FILTER TYPE FILTER CODE FILTER CLASS FLO RATE m 3 /h l/s INITIAL PRESSURE DROP Pa FILTERING SURFACE m 2 H11 with foam sealant CLP-LF-AL-305-305-68-0-H11-GF-P H11 150 40 70 (±20) 2,7 2,5 CLP-LF-AL-457-457-68-0-H11-GF-P H11 335 90 70 (±20) 6,2 3,5 CLP-LF-AL-610-610-68-0-H11-GF-P H11 600 170 70 (±20) 11 7 H14 with foam gasket CLP-LF-AL-305-305-68-0-H14-GF-P H14 150 40 120 (±20) 2,7 2,5 CLP-LF-AL-457-457-68-0-H14-GF-P H14 335 90 120 (±20) 6,2 3,5 CLP-LF-AL-610-610-68-0-H14-GF-P H14 600 170 120 (±20) 11 7 H14 with gel gasket CLP-LF-AL-305-305-80-G-H14-GF-P H14 150 40 120 (±20) 2,7 2,7 CLP-LF-AL-457-457-80-G-H14-GF-P H14 335 90 120 (±20) 6,2 3,8 CLP-LF-AL-610-610-80-G-H14-GF-P H14 600 170 120 (±20) 11 7,7 EIGHT g 288

Goarse panel filter, class G4 Specification Progressive thermally smoothened synthetic polyester having high dust holding capacity and high constancy for humidity The filter media is framed by a rigid plastic frame, which makes filters completely incinerable. Glueable seal provided with filter delivery MATERIALS PART MATERIAL Filter Polyester fibre Frame Plastic Sealant Foamed plastic Operating range Continuous operating temperature 80 C Relative humidity max. 100 % Final pressure drop recommended for filter replacement 200 Pa Initial efficiency (2 µm, 1700 m 3 /h) 50 % FILTER SELECTION FILTER CODE CLASS SIZE GASET DHL 365 DHL 595 DHL 670 ST-F-P-302-302-25-H01-G4-S-P G4 302 x 302 x 25 Yes X ST-F-P-457-457-25-H01-G4-S-P G4 457 x 457 x 25 Yes X ST-F-P-610-610-25-H01-G4-S-P G4 610 x 610 x 25 Yes X DIMENSIONS FILTER CODE H D ST-F-P-302-302-25-H01-G4-S-P 302 302 25 ST-F-P-457-457-25-H01-G4-S-P 457 457 25 ST-F-P-610-610-25-H01-G4-S-P 610 610 25 289

Servicing Close the airflow with the shut off damper. Detach the front panel by gently pulling it down. The front panel can also be removed to further ease the filter change. Remove the filter from the diffuser box by unlocking the brackets and turning the fasteners to the side. Clean carefully the diffuser and housing with a suitable method. Install the new filter & lock it with the fasteners and tighten the screws. Scan the filter for bypass leakages and correct the tightness, if necessary Reattach the front panel by pushing it until the springs lock. Suggested specifications Low turbulence flow supply and exhaust diffuser DHL with HEPA filter for hospital and clean room environments to be installed flush to the ceiling or to the wall. Product code DHL-A-D A = Diffuser size A = 365 A = 595 A = 670 D = Duct connection D = 1 Top connection D = 2 Side connection, round D = 3 Side connection, rectangular Specifics and accessories CO = Colour hite, RAL 9010 X Special colour IO = Ceiling type installation option NA Standard T-profile (All sizes) DC Dampa ceiling (Only for D = 595) Nominal size 595 and 670 adapted for installation in modular suspended ceiling. Diffuser frame (size 595) adapted to suite different ceiling types. The diffuser is installed either fast into ceiling/wall or hanged from the ceiling using movable fixing parts. Diffuser casing is made of galvanized steel and powder painted. The inside of the diffuser is smooth to enable easy cleaning and free from grooves to prevent collection of impurities. Plenum is equipped with an internal measurement tap for filter pressure drop and aerosol test. MA = Material CS Galvanized steel Code Example DHL-595-1, CO=, IO=NA, MA=CS Easy filter change and cleaning of the diffuser and ductwork through open able diffuser panel. Integral guides shall enable exact positioning of the filter to ensure complete tightness. HEPA filter with aluminium frame and cold molded polyurethane or gel seal according to EN 1822 is supplied with individual test certificate (H14). 290