Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Similar documents
Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

MANUFACTURED IN THE UK

MANUFACTURED IN THE UK

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

LED Emergency Luminaires

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

LED emergency exit signage from Channel Safety Systems

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

UL AND CODE COMPLIANCE

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Emergency lighting units EM series

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Specification Sheet for 2D LED Light

Emergency lighting units EM converterled

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Emergency lighting units EM converterled

Norwich Hostry Norwich, UK. Downlight Lighting

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Installation and Operation Instructions 10/04/13

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

Emergency lighting units EM converterled

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Emergency lighting units EM powerled

Emergency lighting units EM powerled

PROFESSIONAL 270 o PIR MOTION DETECTOR

INSTALLATION & MAINTENANCE MANUAL HBL

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Installation Instructions: Eco SpunBay LED High Bays

PC T8 TEC, W PC TEC

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

LED.Commercial 12W LED DD

Central Battery Systems Loadstar AC/DC Systems

Emergency lighting units EM LED Light Engines

Project F J Need (Foods) Ltd - Nantwich. Stormloc LED p363

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Operating Instructions

Installation Instruction

Number 9 January SECTION 1 Dimming of T12 Fluorescent lamps 2. SECTION 2 Dimming of T8 Fluorescent lamps 4. SECTION 3 Do's and Don'ts 6

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

SURE-LITES FBP140XLP Instruction Manual

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

Zone 1 Linear Range - Installation Guide

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Emergency lighting units EM powerled

3000W Dusk to Dawn Light Controller

EMERGENCY ONE-LED TM OMNI-LED DST TM LED DALI EMERGENCY CONVERSION MODULE WITH SELF-TEST

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Emergency lighting units EM INVERTER

Archimedes. user instructions. Simple solutions for everyday independence

Operating Instructions

Emergency lighting units EM powerled

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Emergency lighting units EM powerled

High Efficiency Lighting units

Emergency lighting units EM Inverter

Industrial Linergy LED

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Lighting for: Community Housing

6 Linergy LED+ Industrial IP20 CONTROLS

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

freedom through lightweight solutions

LED Security Wallpack Installation Instruction

SAVE THESE INSTRUCTIONS

Beam lights & conversion kits

MaxLite LED UTILITY WRAP FIXTURES

EMERGENCY ONE-LED TM UNITY-LED TM LED MAINS/EMERGENCY DRIVER

5 Linergy LED. Industrial. Mains lighting IP20

Transcription:

Clean design lines give the Meridian range a leading edge for internal, easily maintained fittings. A straightforward design with a twist and lock diffuser means user-friendly maintenance and cost savings throughout its life. To enable cost saving at installation, the fitting is supplied in the Time-in-a-Box packaging and with a hinged gear tray. Versions High Frequency or Dimmable 3hr Maintained and Auto test (16W & 28W only) Microwave Presence Detector Opal diffuser Black or White base IP44 GE Lighting 2D lamps are fitted as standard. Options Self Fit Photocell Kit MANUFACTURED IN THE UK Fern Howard products are manufactured in the UK at our extensive facility in Alton, Hampshire. Fittings are manufactured and tested in accordance with BS EN 60598. They are also RoHS compliant. Page 1 of 13

TIME-IN-A-BOX is Fern-Howard s unique packaging method, which presents component parts to the installer in exactly the order required. All parts are kept safely in the box - in protective wrappings to avoid breakages - until required, an added advantage if there is a prolonged period between first and second fix. In independently controlled and observed tests, Time-in-a-Box has been found to halve the fitting time required over a comparable luminaire, thus significantly contributing to efficiency and cost savings. IN A BOX SAVES YOU TIME SAVES YOU MONEY TIME Open the box Take out the base moulding Attach to surface Take out gear tray Present to moulding Tighten screws Connect supply Close gear tray Remove lamp from protective wrapping Clip in place Take diffuser from box Screw in place Job done Page 2 of 13

Page 3 of 13

TWIST AND LOCK POLYCARBONATE DIFFUSER IP44 GE 2D LAMP GEAR TRAY RELEASE SCREW HINGED GEAR TRAY ALL APPROVED COMPONENTS POLYCARBONATE BODY Page 4 of 13

INSTALLATION AND OPERATING INSTRUCTIONS THIS FITTING SHOULD NOT BE USED IN AREAS EXCEEDING 25 C AMBIENT AIR TEMPERATURE This fitting must be installed by a qualified electrician and wired in accordance with the latest edition of the IEE Electrical Regulations. Information regarding Part Number, Description, Voltage, Frequency, IP Rating and Lamp type is shown on the label affixed to the box containing the luminaire. Pre-installation ALWAYS TURN OFF THE MAINS SUPPLY BEFORE COMMENCING INSTALLATION Make sure that the mains supply is compatible with the fitting. If IP rating has to be retained a cable gland of the correct IP rating must be used and any fixing holes must be filled with a proprietary silicon sealing compound. High voltage insulation test equipment MUST NOT be used on High Frequency, Emergency or Dimming luminaires. The luminaire is suitable for use within ambient temperature range of -10ºC to + 25ºC ONLY. However, particular attention should be paid to the temperature range for emergency fittings. Installations that regularly drop below 0º C for prolonged periods, particularly when the luminaire is not illuminated are likely to result in a shortened battery life. In such applications a regular testing and battery replacement schedule is recommended. PIR and electronic time switches are not recommended for these luminaries. If used, ensure that there is no Leakage Current when in the Off position and an On time of not less than 20 minutes. Failure to ensure this could potentially impair the performance of the luminaire. Lamp Switching Cycles / Lamp Life CONSTANT SWITCHING REDUCES LAMP LIFE Typical switching cycles should achieve 100% of the manufacturers stated lamp life, however, switching every 5 minutes would reduce this to 20%. Installation Take out the base moulding. Drill out the cable entry and any other Cut Outs required. If cut outs are required for conduit fixing (Not BESA) make sure that the hole is drilled high enough in the side of the base to allow the inside nut to be fitted. Feed the incoming mains through the cable entry gland and secure the base to the mounting surface required using the mounting points provided (failure to do this will cause the fitting to distort) with fixings suitable to support the fitting and for the material to which the base is being attached Put the gear tray into the Hinge position, tighten the two screws and allow the Gear tray to hinge open. Make sure that the incoming mains cable is long enough to allow the Gear Tray to be completely opened. Connect the incoming mains to the terminal block. If using stranded cables, make sure that no stray wires are omitted from the terminal connection. Page 5 of 13

Flying lead or Direct Wiring Standard TB Wiring Incoming Supply Neutral Blue or Black Earth Line Brown or Red N L Blue Gn / Y Brown White Gn / Y White Luminaire Wiring Emergency TB Wiring Incoming Supply Neutral Earth Un-switched Line Switched Line Blue or Black Brown or Red Yellow N 1 2 Blue Gn / Y Brown White Luminaire Wiring To make the fitting Non Maintained leave out the Switched Line Close the Gear Tray (make sure that all cables are clear of the Gear Tray components) and secure with the screw provided. Fit the lamp making sure that it is securely clipped in. Screw on the diffuser making sure that it is correctly tightened to locate in the seal. ADDITIONAL NOTES FOR EMERGENCY LUMINAIRES THIS PRODUCT IS APPROVED FOR SURFACE MOUNTING ONLY These instructions are for non-maintained, maintained and sustained emergency light fittings, which incorporate a fluorescent lamp(s). The ballast is electronic, consisting of a high frequency inverter, battery charger, charge indicator, and battery deep discharge protection circuit. These fittings are self-contained without Rest Mode facility. All emergency versions are 3 hour duration. The Mains supply and the Battery connection must be disconnected before servicing or maintenance. VERY IMPORTANT The battery connections must be left disconnected during installation if the site supply is switched off at the end of the day. Failure to do this will damage the fitting. Page 6 of 13

Circuits The emergency mains supply must be connected to a direct source via a Key Switch (for test purposes only). The switched line must be wired so that it disconnects from the luminaire if the Key Switch is switched off (no power to the fitting). NOTE: The incoming supply earth MUST be connected. NOTE: - Both luminaire supplies must be broken simultaneously (switched and unswitched) when testing. Connections into the ballast must not exceed 2.5mm 2. After connecting the mains supply, check that the charge indicator lamp (LED) is illuminated. The fluorescent lamp should operate when the luminaire is switched on (maintained and sustained only). An initial uninterrupted minimum charge period of 36 hours should always be allowed before testing the module for its rated duration. The recommended maximum battery storage period of one year should not be exceeded. If batteries have been left in a discharged state, one or more full charge / discharge cycles may be necessary to restore them to their normal capacity. Stick the supplied rating label to the luminaire where it can be seen. i.e. On the base, if surface mounted. On the gear tray, if not practical to stick on the base. MUST not be fitted on the diffuser. Page 7 of 13

Routine maintenance Routine maintenance must be carried out in compliance with the requirements of the British Standards Institute Code of Practice BS5266: Part 1 - Emergency Lighting of Premises. The following tests assume a three-hour system Daily: 1 Check that any recorded faults have been rectified. 2 Check that the charge indicator light is illuminated. Monthly: 1 Check that the emergency lamp is operative. 2 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for three minutes. 3 After reverting back to mains supply check the charge indicator light is illuminated. Six Monthly 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for at least one hour. 2 After reverting back to mains supply check the charge indicator light is illuminated. 3 On restoring the mains supply the unit will require 24 hours to recharge before becoming fully operational. Annually 1 Simulate a mains failure and check that the emergency lamp illuminates immediately and remains on for at least 3 hours. 2 After reverting back to mains supply check the charge indicator light is illuminated. 3 On restoring the mains supply the unit will require 36 hours to recharge before becoming fully operational. It is recommended that battery packs and lamps are replaced every 4 years or sooner if the unit performance requirements fail to be met. To maintain optimum unit performance, only approved replacement battery packs and lamps must be used. All routine maintenance checks must be recorded on the unit Test Record / Installation sheet and must be made available for inspection at all times. INSTALLATION / COMMISSIONING AND TEST RECORD Model No Type Installed By Commissioned By Location Serial No (on gear tray) Date Date Routine Test Record First Year Second Year Third Year Fourth Year Fifth Year Monthly Test Signed Date Signed Date Signed Date Signed Date Signed Date 1 Hour Duration 1 Hour Duration Full Duration Page 8 of 13

PHOTOCELL VERSIONS (For External Use Only) The photocell controlled Luminaire, automatically lights as daylight fades and switches off in the morning as the sun rises. The built-in photocell detects light levels and switches accordingly. Variation of natural light will cause the Luminaire to switch on and off at various times as light level alters. Location 40cm Minimum Photocell eye toward natural light. NOT up The ideal location for the unit to be mounted is on an exterior wall with an uninterrupted view of natural light. DO NOT use photocell Luminaires in Internal locations. The fitting can be used in many locations, providing the following precautions are observed:- If mounting on a ceiling or wall, the photocell eye should be directed towards the best natural light. Similarly when under a canopy, eaves or porch, direct the photocell eye towards the best daylight. Ensure that the distance between the photocell eye side of the fitting and any adjacent surface, either wall, ceiling, eaves or soffit is a minimum of 40cm. The unit can be affected by adjacent light sources, including light from inside the property. Ensure the photocell eye is NOT in the light path of any other light fitting. To Test: Test the correct operation of the unit by switching on the mains supply and completely covering the photocell lens until the lamp strikes. Note:- There is a deliberate delay in switching on to prevent Momentary switching during Twilight or Dusk periods. Page 9 of 13

GENERAL ROUTINE MAINTENANCE At commissioning and handing over of the installation, ensure that a copy of this data is presented to the authority responsible for the operation, maintenance and repair of Luminaires. Cleaning of the Luminaire or lamp replacement must only be carried out after the fitting has been isolated from the electrical supply. ALWAYS check before servicing. Cleaning should be carried out at regular intervals to ensure that contaminants do not accumulate to an extent that will impair the thermal safety of the Luminaire, or degrade the optical performance of the lamp. DO NOT use Spirit based cleaners. Failed lamps must be replaced immediately, with Lamps of the same type, if a Starter Switch is fitted, this should be changed at the same time. Undetected or unattended failed lamp replacement will result in the Ballast unit overheating and ultimately will cause its failure, rendering the fitting useless. Notes: This luminaire should not be modified or repaired by any persons other than those nominated by the manufacturer. Any unauthorised modification or repair may render the luminaire unsafe and will invalidate the warranty and conformance to any safety or safety standards that may apply. The company will accept no responsibility for any modified fittings or for any damage caused as a result of modifications. All details are given as guidance only and do not constitute a contract. We reserve the right to change or withdraw products without notice. Performance and Warranty This product is warranted for twelve months from the date of installation, provided that the installation is carried out within two months of purchase, subject to the following conditions. This warranty will only be valid if the fittings have remained unmodified and used as per this instruction leaflet and our literature. Fern - Howard Ltd. shall not be liable for any consequential loss or damage caused directly or indirectly by any defective or otherwise. Battery packs are guaranteed for 12 months but are expected to have a life of at least four years if used within the specified temperature limits. Disposal The disposal of any electrical equipment, including this fitting may be subject to Local Authority Regulations and therefore should be consulted for specific guidance. The batteries within this fitting are Nickel Cadmium and must be disposed of as per Local Authority Regulations for the disposal of toxic waste. Page 10 of 13

2 PIN LAMP SWITCH START 4 PIN LAMP SWITCH START HIGH FREQUENCY DIMMING Page 11 of 13

EMERGENCY MAINTAINED EMERGENCY MAINTAINED AUTO TEST EMERGENCY MAINTAINED DALI Page 12 of 13

Lamp Lumen Output (Mains- Mode) Approx Lamp Life (Hrs) Nominal Lamp Current A MAGNETIC HF EM Parallel Correction Capacitor Corrected Lamp Current A Circuit Watts Corrected HF Current A Circuit Watts BLF HF BLF Emergency Normal BLF Emergency EM Mode 16W 1050 10,000 0.195 2uf 0.09 27.83 0.121 18.0 0.960 0.950 0.180 28W 2250 15,000 0.320 4uf 0.15 34.5 0.130 28.7 0.960 0.750 0.120 38W 3000 15,000 0.430 4uf 0.200 46.0 0.180 39.7 0.960 Lamp Weight Weight HF Weight EM 16W 1.6 1.26 2.12 Lumen Output In Emergency Mode Lamp Mains EM 1Hr EM 2Hr EM 3Hr 28W 1.85 1.4 2.17 16W 1050 146 143 134 38W 2.21 1.43 28W 2250 196 196 171 150 o 180 o 150 o Size 302mm Dia x 105 Deep Cable Entry Centre Rear BS Style Body Material Polycarbonate 120 o 120 o Diffuser Material Polycarbonate Gear Tray Material Polycarbonate Lamp GE 2D 3500K Wiring TB 2 x 2.5mm 2 90 o 90 o Diffuser Fixing Control Voltage Twist On 240V 50Hz 20 60 o 40 60 60 o 80 30 o C0 / C180 0 o cd / 1000 im 30 o C90 / C270 LOR = 0.32 SHR MAX = 1.53 SHR NOM = 1.50 Room Reflectances Room Index C W F 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.50 0.20 0.17 0.20 0.22 0.24 0.26 0.28 0.29 0.30 0.31 0.30 0.15 0.17 0.20 0.21 0.24 0.26 0.27 0.29 0.30 0.10 0.13 0.15 0.18 0.19 0.22 0.24 0.25 0.27 0.29 0.50 0.50 0.20 0.16 0.19 0.21 0.22 0.25 0.26 0.27 0.29 0.29 0.30 0.14 0.16 0.19 0.20 0.23 0.24 0.26 0.27 0.28 0.10 0.12 0.15 0.17 0.19 0.21 0.23 0.24 0.26 0.27 0.30 0.50 0.20 0.16 0.18 0.20 0.21 0.23 0.25 0.25 0.27 0.28 0.30 0.14 0.16 0.18 0.20 0.22 0.23 0.24 0.26 0.27 0.10 0.12 0.14 0.17 0.18 0.20 0.22 0.23 0.25 0.26 0.00 0.00 0.00 0.11 0.13 0.15 0.17 0.19 0.20 0.21 0.23 0.24 FIGURES BASED ON 38W CORRECTED SWITCHSTART FITTING Page 13 of 13