UK I. Screw connection system

Similar documents
Bolt connection terminal blocks OTTA, UHV, HV. General information

Disconnect and component terminal blocks

UK 6-FSI/C. Extract from the online catalog. Order No.:

PIT 2,5-TG. Extract from the online catalog. Order No.:

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

PT 2,5-QUATTRO/2P BU. Extract from the online catalog. Order No.:

PT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.:

ST 4-HESI (5X20) Extract from the online catalog. Order No.: Fuse terminal block for assembly on NS 35, for 5 x 20 cartridge fuse inserts

STS 2,5. Extract from the online catalog. Order No.:

onlinecomponents.com

ST-COMBI 4 mm 2 Pluggable Spring-Cage Terminal Blocks

UKK 5-PV. Extract from the online catalog. Order No.:

8WH2 Spring-Loaded Terminals

Circuit Breakers. DIN rail-mounted equipment protection

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

8WH6 ipo Installation Terminals

8WH2 Spring-Loaded Terminals

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

Electronic Circuit Breaker ESS20-0..

Terminal Blocks, Fuse Blocks and Fuse Holders

Electronic Circuit Breaker ESS20

SIRIUS 3RU2 Thermal Overload Relays

Terminal Blocks, Fuse Blocks and Fuse Holders

Datasheet. W-series terminal with clamping yoke connection WDU 4

Load and Motor Switches, Load-Break Switches Series 8549

BETA Switching Switches and Light Indicators

Power distribution components

Viking 3 - Screw connection Disconnect terminal blocks

Crimpmate Range pitch 5.00


NEW. Datasheet. WMF 2.5 Terminal Series

8WH6 ipo Plug-In Terminals

Data sheet. W-Series WDU 4 SL/EN

Terminal blocks with clamping yoke and screw connection system

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

TALOGUE PRODUCT CA PRODUCT CATALOGUE

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

JCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3

Spring Cage Miniature Terminal Blocks FK-MPT 0,5/ -3,5

Data sheet... W terminal earth terminal WPE 4

Unimate Range Pitch 5.08

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

PHOENIX CONTACT - 01/2008

Powermate Range pitch 7.00 Powermate Range pitch 7.00

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Data sheet... W-Series WPE 4

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

Feed-through terminal, 2.5 mm², Tension clamp connection, Wemid, dark beige, TS 35

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Datasheet. W-series terminal with clamping yoke connection WDU 2.5 RT

IEC Low Voltage General Purpose Protection

- 1 - General ordering data Order No

SENTRON Switching and Protection Devices Switch Disconnectors

SCREW-TYPE DISTRIBUTION BLOCKS

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

DBL distribution blocks 3x1 pole

New VikingTM 3, the innovation

Distribution terminal block; 3 x CAGE CLAMP connection 10 mm²; 1 x screw-clamp connection 35 mm²

Datasheet WMF 2.5 Terminal Series NEW. Phone: Fax: Web: -

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

Clearwater Tech - Phone: Fax: Web: -

Professional tools 1. From Phoenix Contact. General information

W-series W-series W-series sets standards! W-series offers advantages 1) Easy project planning 3) Time-saving potential distribution

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

PANEL PANEL MOUNTING COMPONENTS

Operating Instructions (Translation)

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

DOUBLE-LEVEL TERMINAL BLOCKS SRKD SSLD

Control Circuit Protection

BLOCK CATALOG SUPPLEMENT LOREM IPSUM DELORE LOREM IPSUM DELORE LOREM IPSUM

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

MK 2/ mm 2 IEC UL CSA. IEC UL CSA Rated voltage AWG AWG AWG AWG Rated surge voltage / pollution severity

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Data sheet TERMSERIES TRZ 120VUC 1CO

MANUAL 2018 AL 2018 U AN M

Printview: Multilevel installation terminal block; N/L - Item No.:

Protection Equipment. 5/2 Introduction

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

ZS10-PE Screw Clamp Terminal Blocks Ground

Datasheet. Approvals. Technical data. Feed-through terminal WK 4 / U BLUE /V0. General. Technical data. Connection Data

Protection Equipment

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

Technical data for manual motor starters Type MS325

Ex UPS standard Series 8265

SCREW-TYPE DISTRIBUTION BLOCKS

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

Han-Power Energy Bus Components

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

ZS4-PE Screw Clamp Terminal Blocks Ground

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

Solenoid Valve Island Type 3965

Bulletin 1492-J, -W 1492-L Type Screw Type Terminal Blocks Spring-Clamp Terminal Blocks

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

BETA Low-Voltage Circuit Protection

Terminal blocks with Push In connection technology. Product Information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS MSP. Terminal Blocks

Transcription:

UK I crew connection system Accessories for Phoenix Contact modular terminal blocks The technical ease of operation of modular terminal blocks is mainly determined by the switching accessories. With the UK versions, all relevant requirements as to switching can be realized with a minimum of storage and easy handling. tampings, screws and spacer sleeves for the bridges are made completely of special copper alloys with galvanic tin-plated or nickelplated surface refinement. Important note: When using accessories and mixing with other series and sizes, the measured values must be redefined. The housing foot is designed to be With the ZB.,, marking system, " universal " so that the terminal blocks all Phoenix Contact modular terminal can be snapped onto the two major blocks with a marker groove can be DIN profiles U and Cam. labeled optimally, fast and economically. Detailed explanations can be found from page 392 onwards. 208 Phoenix Contact

Any number of positions can be separated from the 10-position strip of the fixed bridge with FBI insulating cap, inserted into the terminal housing and screwed tight. With the FBRI fixed bridge, the screws and captive spacer rollers are already fitted in the bridge strip. This bridge is supplied with 2 to 10 positions. The IBI 10 isolator bridge bar enables switchable cross connections when used in conjunction with the I bridge bar isolator. The bridge screw functions as a currentcarrying switching member. The EB 10-... insertion bridge possibly in conjunction with a conductor is clamped at the connection points. The 10-position comb can be divided in any way; individual teeth can also be removed in order to bypass terminal blocks. The PB test socket enables reliable test connections. For constructional widths of over 6 mm, the connection is made with normal 4 mm P test plugs, and below this, with 2.3 mm MP miniature test plugs. ice`. e The T separating disks must be used on both sides for all bridges in the terminal center to retain the full insulation distances. The separating plate is designed in such a way as to enable it to be inserted later, i.e. without the need for extra space, and for it to snap lock into place. 0,000-00 The BH 2-... switch bar creates a reconnectable connection between two neighboring terminal blocks. Depending on the type of terminal block or the dielectric strength in an open switching status, either one or two terminal blocks end covers must be added. ~i ', I 6 N The K short circuit plug ATP partition plates extend serves to short circuit two or more above the terminal block profile on all neighboring terminal blocks which are sides, so that a clear division of groups equipped with test sockets. is achieved. Phoenix Contact 209

Universal terminal blocks, UK UK 1,5 N The UK universal terminal block series has the following typical features, which are the decisive factor for practical applications: Universal foot, allowing it to be utilized on N 35 and N 32 mounting rails Closed screw shafts for ideal guidance of the screwdriver Uniform accessories, e.g. end cover, partition plates etc., covering a wide range of cross sections Potential distribution alternatively via fixed bridges in the terminal center or insertion bridges in the clamping space Protective conductors with the same shape (from page 216) and neutral disconnect terminal blocks (from page 254) and Uniform marking methods with the ZB... marking system. Description Terminal block, with universal foot for mounting on vor u Color Gray blue (1) Cover Gray blue (2) Fixed bridge, for cross connections in the terminal center, screw heads with insulating collar. 10-position, divisible, with 10 screws (3) Insertion bridge, fully insul., 2-pos., fully insulated, 3-pos. divisible, fully insulated, 10-pos. (4) Isolator bridge bar, 10-position, divisible, with 10 screws, for switchable branches with (5) Bridge bar I-K 4 as distance piece (6) witch bar for 2 terminal blocks, complete, to increase insulation an end cover must be interposed (7) eparating disk, for electrical separation of neighboring bridges, can be fitted later. no loss of pitch (8) Partition plate, for visual and electrical separation of terminal groups, 1.5 mm thick i TCTI 11TUll _LL![Mâ [1F rn p o Terminal width 4.2 I U [mm ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.14-1.5 0.14-1.5 26-16 17.5 500 EN 50019' 0.14-1.5 0.14-1.5 26-16 17 275 " EU type-examination certificate no.: KEMA 98ATEX1651 U =) c~us B P 's[ BV/LR/NV/PR Ex KEMA : FTZU Order No. pos. Pkt UK 1,5 NP) 30 05 83 7 50 UK 1.5 N BU') 30 05 84 0 50 D-UK 2,5 30 01 02 2 50 D-UK 2,5 BU 30 01 10 3 50 FERN 10-4 N.12A 3001624 ATP-UK 30 03 22 4 50 (9) Test socket, for test connection with test plug MP or reducing plug RP (10) Test socket, insulated, only used with FBI, IBI, for test connections with test plug MP or RP (11) crewdriver Z 0.4 x 2,5 1205037 10 (12) Zack marker strip, 10-section, White ZB 4 (for order data, see page 396) Dimensions Width / length / cover width Height (N 357.5! N 35%15 / N 32) Technical data in accordance with IEC / DIN VDE Maximum load current / cross section Max. cross section with insertion bridge (solid/stranded) Rated surge voltage / contamination class urge voltage category / insulating material group Connection capacity tranded with ferrule without / with plastic sleeve [mm-[ Multi-conductor connection (2 cond. with same cross section) olid / stranded [mm'] tranded with ferrules without plastic sleeve (mm2] tranded with TWIN ferrule with plastic sleeve [mm-] tripping length Internal cylindrical gauge (IEC 60 947-1) Thread Torque [Nm] ') The max. nominal voltage is determined by the DIN rail, Insulation material withv550 V. Inflammability class in acc. with UL 94 ') For information on installation and usage of accessories for Approval data (UUCUL and CA) EEx e applications, see page 508. Nominal voltage : current ; conductor sizes UUCUL: [V] / [A) / AWG ") For further bridges. see cross ref. lists from page 232. CA: [V]/[A]/AWG 210 Phoenix Contact uitable warning labels are documented on page 414 4.2/42.5/1.5 42 / 49.5 / 47 [A] / [mm'] 17.5 / 1.5 [mm, ] [kv] / - 6/3 - / - III / I 0.25-0.75/0.25-0.75 0.14-0.7510.14-0.75 025-024 0.5 7 Al M2 022-025 Vo 300/15/30-14 300/15/30-14 1

UK 2,5 N UK3N UK 5 N Terminal width 5.2 Terminal width 5.2 Terminal width 6.2 I U I U I U [mm2] solid stranded AWG [A] [V) [mm 2 ] solid stranded AWG [A] (V] [mm 2] solid stranded AWG [Al (V] IEC 60 947-7-1 0.2-4 0.2-2.5 24-12 24 800 IEC 60 947-7-1 0.2-4 0.2-2.5 24-12 32 600 IEC 60 947-7-1 0.2-6 0.2-4 24-10 41 800 0 EN 50 019'.2-4 0.2-2.5 24-12 28/22 550 EN 50 019` 0.2-4 0.2-2.5 24-12 28/22 750 EN 50 019'.2-6 0.2-4 24-10 30 7501 ) ' EU type-examination certificate no.: KEMA 98ATEX1651U') ' EU type-examination certificate no. : KEMA 98ATEX1651 U ) * EU type-examination certificate no.: KEMA 98ATEX1651U -) e%us j KE~w] CCA B P '61'' BV/LRINV/PR G KEMA ciw ei FTZU Pkt. c~us P KEG' CCA B P 6 1 BV/LR/NV/PR/R/NK/AB Ex KEMA : :',; : c%us ei.. FTZU Pkt. c%us [ CCA B P BV/LR/NV/PR/R/NK/AB Ex KEMA.`.a.'- c us ' e ' FTZU PCs. UK2,5N 3 ) 3003347 50 UK 2.5 N BU3 ) 30 03 35 0 50 UK 3 N 3 ) 30 01 50 1 50 UK3NBU 3) 3001514 50 UK5N3) 3004362 50 UK 5 N BU 3 ) 30 04 38 8 50 D-UK 2,5 30 01 02 2 50 D-UK 2,5 BU 30 01 10 3 50 D-UK 4/10 D-UK 4/10 BU 3003020 3003101 50 50 D-UK 4/10 30 03 02 0 D-UK 4/10 BU 30 03 10 1 50 50 FBRI 10-5 N I,, 24 A 27 70 64 2 10 FBRI 10-5 N : 30 A 27 70 64 2 10 FBI 10-6 41 A 02 03 25 0 10 EBL 2-5 EBL 3-5 IL 10-5 I,,,,,: 24 A 23 03 14 5 24A 2303158 24 A 23 03 13 2 100 100 10 EBL 2-5 1.,,,: 24 A 23 03 14 5 10 EBL 3-5 24 A 23 03 15 8 10 EBL 10-5 24 A 23 03 13 2 10 EB2-6 I,,,..:32A 0201155 100 EB 3-6 32 A 02 01 14 2 100 EB 10-6 32A 02 01 13 9 10 IBI 10-6 30 A 03 01 50 5 10 I-K 4 13 02 33 8 100 UBR 2-7 : 18 A 23 03 23 9 1 UER 2-7 34 A 23 03 23 9 1 T-KK 3 27 70 21 5 50 T-K 13 02 21 5 50 T-K 13 02 21 5 50 ATP-UK 30 03 22 4 50 ATP-UK 30 03 22 4 50 ATP-UK 30 03 22 4 50 PB 3/10/4 06 01 29 2 100 PB 3/10/4 06 01 29 2 100 PB 3/10/4 06 01 29 2 100 PBJ 3/13/4 02 01 30 4 100 PBJ 3/13/4 02 01 30 4 100 PBJ 3/13/4 02 01 30 4 100 Z O,6 x 3,5 12 05 05 3 10 Z 0,6 x 3,5 1205053 10 Z 0,6 x 3,5 1205053 10 ZB 5 (for order data, see page 397) ZB 5 (for order data. see page 397) ZB 6 (for order data, see page 397) 5.2 / 42.5 / 1.5 42/49.5/47 5.2 / 42.5 / 1.8 47/54.5/52 6.2 / 42.5 / 1.8 47 / 54.5 / 52 2412.5 2.5 / 2.5 III / 32/4 4/2.5 III/I 41/6 4/4 III/I 0.25-2.5 / 0.25-1 0.25-2.5/0.25-1.5 0.25-4 / 0.25-2.5 02-1/025 1 025-1 0.5-1.5 7 A3 M3 0.6-0.8 V2 0.2-1.5/0.2-1.5 025-1.5 0.5-1 8 A3 M3 0.6-0.8 V2 0.2-1.5/0.2-1.5 025-1.5 0.5-2.5 8 A4 M3 0.6-0.8 300/20/30-12 300/20/28-12 600/20/28-12 600/20/28-12 600/30/30-10 600/40/28-10 Phoenix Contact 211

Universal terminal blocks, UK 0 4, o ' = Ahop f_,,, r,`kk,, All universal terminal blocks from the UK... series can also always be used in the EEx e field in acc. with EN 50 019. The corresponding EU type-examination certificate nos. of the Ex approval can be found in the technical connection data. The size of the universal terminal blocks for cross sections of 6 mm 2 and more has been optimized in exactly the same way as the little brothers. Thus, for example, the UK 6 N has a pitch of only 8 mm with a max. nominal voltage of 800 V. As a result of the continuity in the shape of all UK terminal blocks, from UK 3 N to UK 10 N, accessories such as partition plates or end covers can here be used uniformly. Description Terminal block, with universal foot for mounting on C, or Lr (1) Cover Color Gray Blue (2) Fixed bridge, screw heads with 2-pos. insulating collar. divisible, with 3-pos. screws 10-pos. (3) tep bracket, to connect UK 10 N (FBI 10-10) with UK 5 N (FBI 10-6) UK 35 (FBI 3-15) with UK 5 N (FBI 10-6) (4) Insertion bridge, fully insul., 2-pos. fully insulated. 3-pos. _ divisible, fully insulated, 10-pos. (5) Isolator bridge bar, 10-position, divisible, with 10 screws, for switchable branches with (6) Bridge bar I-K 10 as distance piece (7) witch bar for 2 terminal blocks, complete, to increase insulation an end cover must be interposed (8) eparating disk, for electrical separation of neighboring bridges, can be fitted later, no loss of pitch (9) Partition plate, for visual and electrical separation of terminal groups, 1.5 mm thick Gray Blue it ll T [ [_u u_u s~kl1'lo p UK 6 N Terminal width 8.2 I U [mm2 ] solid stranded AWG [A] [V) IEC 60 947-7-1 0.2-10 0.2-6 24-8 57 800 0 EN 50 019 '.2-10 0.2-6 24-8 53/38 750 ' EU type-examination certificate no.: KEMA 98ATEX1651 U,) c''mus k K]][ CCA P BV/LR/NV/PR/R/NKIAB Ex KEMA `s: clus' r1 FTZU Pos. UK 6 M) 30 04 52 4 50 UK 6 N BU-) 30 04 97 7 50 D-UK 4/10 30 03 02 0 50 D-UK 4/10 BU 30 03 10 1 50 FBI 10-8 57 A 02 03 26 3 10 EB 2-8 h,,, : 57 A 02 02 15 4 100 EB 3-8 57 A 02 02 14 1 100 EB 10-8 57 A 02 02 13 8 10 IBI 10-8 I,, : 57 A 03 01 53 4 10 I-K 10 13 03 33 7 100 B 2-8113 N I,,,,. : 40 A 02 00 06 2 T-K 13 02 21 5 50 ATP-UK 30 03 22 4 50 I (10) Test socket, for test connection with test plug P (11) Test socket, insulated, only used with FBI. IBI, for test connection with test plug P (12) Zack marker strip, 10-section White l PB 41716 03 03 29 9 100 PBJ 4/1516 :... (for order data. see page 390) ZB 8 (for order data, see page 399) ') For information on installation and usage of accessories for EEx e applications. see page 508. ') For extra accessories, see cross ref. lists, page 232. 212 Phoenix Contact (13) crewdriver Z 1,0 x 4,0 1205066 10 Dimensions Width / length / cover width 8.2 / 42.5 / 1.8 Height (N 35/7.5 / N 35/15 / N 32) 47/54.5/52 Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [AI/[mm'-] 57/10 Max. cross section with insertion bridge (solid/stranded) [mm 2] 4/4 Rated surge voltage / contamination class [kv] / - urge voltage category / insulating material group - / - III/I Connection capacity tranded with ferrule without / with plastic sleeve [mm'] Multi-conductor connection (2 cond. with same cross section) 0.25-6/0.25-6 olid / stranded [mm, ] 0.2-2.5/0.2-2.5 tranded with ferrules without plastic sleeve [mm 2 ] 025-1.5 tranded with TWIN ferrule with plastic sleeve [mm, ] 0.5-4 tripping length 10 Internal cylindrical gauge (IEC 60 947-1) A5 Thread M4 1 Torque [Nm] L5-1.8 Insulation material Inflammability class in acc. with UL 94 Approval data (UUCUL and CA) Nominal voltage 1 current conductor sizes UL/CUL : [V] / [A] / AWG 600/50/26-8 CA : [V] / [A] / AWG 600/50/26-8 uitable warning labels are documented on page 414.

UK10N UK 16 N UK 35 Terminal width 10.2 I U [mm2] solid stranded AWG [A] [V] IEC 60947-7-1 0.5-16 0.5-10 20-6 76 800 EN 50 019' 0.5-16 0.5-10 20-6 73/57 750 EU type-examination certificate no.. KEMA 98ATEX1786U ') Terminal width 12.2 I U [mm2] solid stranded AWG [A] [V] IEC 60 947-7-1 2.5-25 4-16 12-4 101 800 EN 50 019` 2.5-25 4-16 12-4 88/72 750 EU type-examination certificate no.: KEMA 98ATEX1786U ') Terminal width 15.2 I U [mm 2] solid stranded AWG [A] [V] IEC 60 947-7-1 0.75-50 0.75-35 18-0 150 1000 EN 50 019' 0.75-50 0.75-35 18-0 145/112 750 EU type-examination certificate no.: KEMA 98ATEX1786U ' ) s us @ 'K[[ CCA B P '~6l! BV/LR/NV/PR/R/NK/AB KEMAclMus nn FTZU Tim e III PCs. Maus B KE7 CCA B P 6' BV/LR/NV/PR/R/NK/AB Ez KEMA Maus 6l FTZU c Rlus 1p [K) ] CCA B P 6 L'' BV/LR/NV/PR/R/NK/AB z KEMA C-': c%us 61 ; FTZU Phi. UK 10 N') 30 05 07 3 50 UK 10 N BU') 30 05 08 6 50 0-UK 4110 0-UK 4110 BU 30 03 02 0 50 3003101 50 FBI 10-10 I,. : 76 A 02 03 27 6 10 UK16N2) 3006043 50 UK 16 N BU') 30 06 05 6 50 D-UK 16 30 06 02 7 50 D-UK 16 BU 30 06 10 8 50 FBI 10-12 : 101 A 02 03 45 4 10 UK 35.) 30 08 01 2 50 UK 35 BU) 30 08 02 5 50 Enclosed housing, no cover FBI 2-15 150 A 02 01 33 3 10 FBI 3-15 150 A ' 02 01 27 8 10 FBI 5-15 150 A 07 11 30 2 10 TL 10N/5N : 41 A 02 04 11 0 10 11-10 I,, ;,, : 70 A 02 03 15 3 100-10 70 A 02 03 32 8 100,10-10 70 A 02 03 13 7 10 EB 10-12 IBI 10-10 I,,, : 52 A 03 01 52 1 10 I-K 10 1303337 100 3006137 10 TL 3515 41 A 02 04 10 7 10 EB 10-15 110A. 0205135 10 BH 2-15 only with short link 120 A 0205232 T-K 13 02 21 5 50 T-K 13 02 21 5 50 T-K 1302215 50 ATP-UK 30 03 22 4 50 ATP-UK 30 03 22 4 50 TP-UK 35 7.5 mm thick 30 08 09 6 10 PB 417/6 03 03 29 9 100 PB 4/7/6 03 03 29 9 100 PB 6/5/6 02 05 29 0 100 PBJ 411516 :... (for order data. see page 390) PBJ 4/15/6 :... for order data, see page 390) Z 1.0 x 4,0 1205066 10 Z 1,0 x 4,0 12 05 06 6 10 Z 1,0 x 6,5 1205079 10 10.2/42.5/1.8 47/54.5/52 76/16 10 / 10 III /I 0.5-10/0.5-6 0.5-4/0.5-4 0.5-2.5 0.5-6 10 B6 M4 1.5-1.8 600 / 65 / 24-6 600/65/24-6 12.2 / 42.5 / 1.5 54/61.5/59 101 /25 16/16 Ill/I 1.5-16/1.5-16 1.5-6/1.5-4 1.5-6 0.75-10 11 B7 M4 1.5-1.8 600/85/22-4 600/85/22-4 15.2/50/- 62/69.5/67 150 / 50 35 / 35 II /I 0.75-35/0.75-35 0.75-16/0.75-10 0.75-10 0.75-6 16 B9 M6 3.2-3.7 1000/150/18-1/0 600/140/18-2 Phoenix Contact 213

Universal high current terminal blocks, UKH an. The universal high current terminal blocks cover the cross section range from 16 to 240 mm 2. A reliable cable connection is guaranteed by effective constructive measures. For example: Three-point centering of the conductor in the prism-shaped sleeve base Fluted contact surface guaranteeing low contact resistances and crews secured using spring-loaded elements. The terminal blocks have an enclosed half-shell insulation housing made of polyamide 6.6 and can be mounted on the N 35 and N 32 DIN rails in acc. with EN 60 715. For 16 to 95 mm 2, green-yellow ground terminal blocks are available, see page 219. Note: For high current plug with bolt connection, see page 332. Description Terminal block, for mounting on C~.uorLT (1) Fixed bridge, for cross connections, screw heads with insulating collar, first remove partition plate (2) Insertion bridge, fully insulated, is laid into terminal sleeve and snap fitted into the terminal housing 2-pos. 3-pos. (3) Pick-off terminal block, when wiring the pick-off with a smaller cross section. observe the overload and short-circuit resistances specified in VDE 0100 part 430. (4) Insertion profile, levels out the prism-shaped sleeve when using flat conductors, see table on page 336 (5) End bracket, for end support of UKH 50 - UKH 240, is pushed onto DIN rail and fixed with 2 screws, aluminum, 10 mm wide.. for mounting on r, for mounting on L-f (6) Allen wrench, fully insulated, safety tool in accordance with DIN VDE 0680, length : 150 mm. handle width : 110 mm (7) crewdriver Color Gray Blue 2-pos. 3-pos. D~ '71] UH11 UKH 50 Terminal width 20.0 I [mm 2] solid stranded AWG [A] U [V] IEC 60 947-7-1 16-50 25-50 6-0 150 1000 EN 50 019' 16-50 25-50 6-0 135 750 ' EU type-examination certificate no.. KEMA 98ATEX1786U c~us B K)) CCA a P BV/LR/NV/PR/R Ex KEMAFTZU Order No. UKH 50 3009118 10 UKH 50 BU 3009105 10 FBI 2-20 I,.,150 A 0201346 10 FBI 3-20 150 A 02 01 31 7 10 AGK 10-UKH 50 I,,,,. : 57 A 30 01 76 3 UKH 50 EP 3009228 1D E/AL-N 32 1201659 10 E/AL-N 35 1201662 10 Z 1,2 x 8,0 1205082 1 ¼ 10 (8) Zack marker strip, 10-section White AGK 10 UKH... The fully insulated AGK 10 pick-off terminal blocks enable a voltage connection up to a nominal voltage of 1000 V (10 mm 2 ) to be made with the high current terminal blocks. All three versions can be labeled with the Zack marker strip. Dimensions Width / length Height (N 35/15 / N 32) Technical data in accordance with IEC / DIN VDE Maximum load current I cross section [A] / Max. cross section with insertion bridge (solid/stranded) [mm 2] Rated surge voltage / contamination class [kv] / - urge voltage category / insulating material group -/- Connection capacity2) tranded with ferrule without / with plastic sleeve [mm 2] Multi-conductor connection (2 cond. with same cross section) olid / stranded [mm"] tranded with ferrules without plastic sleeve [mm'] tripping length Internal cylindrical gauge (IEC 60947-1) Thread Torque Insulation material Inflammability class in acc. with UL 94 Approval data (UUCUL and CA) Nominal voltage i current ; conductor sizes INmI UUCUL : [V] / [Al / AWG CA : [VI/ [AI./ AWG ") For information on installation and usage of accessories for EEx e applications, see page 508. 20 / 70.5 83.5 / 81.5 150 / 50 II/I 25-50/25-50 10-16/10-16 10-16 24 B10 M6 6-8 600/150/6-0 600/125/6-0 2 ) For suitability of flat conductors for clamping, see page 336. 214 Phoenix Contact

UKH 95 UKH 150 UKH 240 Terminal width 25.0 I U [mm 2] solid stranded AWG (A] [V] IEC 60 947-7-1 25-95 35-95 4-000 232 1000 EN 50 019' 25-95 35-95 4-000 210 750 ' EU type-examination certificate no. : KEMA 98ATEX1786U ') Terminal width 31.0 AWG I U [mm2] solid stranded kcmil [A] [V] IEC 60 947-7-1 35-150 50-150 2-300 309 1000 EN 50 019' 35-150 50-150 2-300 265 726 ' EU type-examination certificate no.. KEMA 99ATEX8332U,) Terminal width 36.0 AWG I U [mm2 ] solid stranded kcmil [A] [V( IEC 60 947-7-1 70-240 70-240 00-500 415 1000 EN 50 019' 70-240 70-185 00-500 350/300 726 EU type-examination certificate no. : KEMA 99ATEX8332U ') Mus! KEeJCCAe P 'ct BV/LR/NV!PR/R G KEMA FTZU PM. Mus B B P BV/LR/NV/PR/H/NK Ex KEMA FTZU Order No. Pkt. Maus P B P et% BV/LR/NV/PR/R/NK Ex KEMA FTZU Pcs UKH 95 30 10 01 3 10 UKH 95 BU 30 10 13 6 10 UKH 150 30 10 11 0 10 UKH 150 BU 30 10 12 3 10 UKH240 3010217 ' 10 UKH 240 BU 07 11 85 2 10 EB 2-25/UKH I T : 232 A 02 01 36 2 10 EB 3.25/UKH 232 A 02 01 37 5 10 EB 2-31/UKH Ima,,: 232 A 02 01 38 8 10 EB 3-31/UKH 232 A 02 01 39 1 10 EB 2-36/UKH 320 A 02 01 40 1 10 EB 3-36/UKH 320 A 02 01 41 4 10 10-UKH 95 1. : 57 A 3003541 10 AGK 10-UKH 150/240 l o,,,, : 57 A 30 03 55 4 10 AGK 10-UKH 150/240 I ma,.: 57 A 30 03 55 4 10 UKH 95 EP 30 09 23 1 10 UKH 1501240 EP 30 09 24 4 10 UKH 150/240 EP 30 09 24 4 10 E/AL-N 32 12 01 65 9 10 UAL-N 35 12 01 66 2 10 E/AL-N 32 12 01 65 9 E/AL-N 35 12 01 66 2 10 10 E/AL-N 32 12 01 65 9 ' 10 E/AL-N 35 I 12 01 66 2 10 VDE-I 6 12 01 93 4 VDE-I 8 12 01 94 7 VDE-I 8 12 01 94 7 1 ZB 10 for order data, see page 399) ZB 10 (tor order data. see page 399) 25 / 83 97.5 / 95.5 31 / 100 118.5 / 116 36 / 100 131.5 / 129.5 232 / 95 95/70 III/1 309 / 150 150/120 III / I 415 / 240 240 / 185 III.'I 35-95/35-95 50-150/50-150 70-185/70-185 25-35 / 25-35 16-35 33 B12 M8 3) 15-20 25-50/35-50 25-50 40 B14 M10 3 ) 25-30 35-95 / 50-95 35-50 40 B15 M10 3) 25-30 600 / 230 / 2-000 600/200/1-000 600 / 285 / 2 AWG - 300 kcmil 600 / 275 12 AWG - 300 kcmil 600 / 380 / 00-500 kcmil 600 / 400 / 0-500 kcmil 3) crews with hexagonal socket-head. Phoenix Contact 215

Universal ground terminal blocks, ULKG This terminal block series not only fulfills the strict requirements made of ground terminal blocks, it actually surpasses them. The terminal blocks have an enclosed, yellow-green insulation housing in order to emphasize the PE ground conductor function. Their shape and pitch are identical to those of the UK terminal blocks with the same cross section. The terminal blocks can be assembled and disassembled without any space being required to the sides. Description Color Terminal width 4.2 (IEC) [mm 2 ] ULKG 1,5 N rigid solid flexible stranded AWG IEC 60 947-7-2 0.14-1.5 0.14-1.5 26-16 EN 50 019" 0.14-1.5 0.14-1.5 26-16 * EU type-examination certificate no.: KEMA 99ATEX4487U ') For current carrying capacity of mounting rails, see page 499. c%us P " RV/LR/NV G KEMA/FTZU clus ULKG 2,5 N Terminal width 5.2 [mm, ) solid stranded AWG IEC 60 947-7-2 0.2-4 0.2-2.5 24-12 EN 50 019' 0.2-4 0.2.2.5 24-12 EU type-examination certificate no. : KEMA 96ATEX4370U '1 For current carrying capacity of mounting rails, see page 499. our 'K'4. CCA'B t' '' BV/LR/NV/PR Ex KEMA ii c%us FTZU Ground terminal block, with green-yellow insulation housing, for mounting on C_t or 1_2r Ground terminal block, with green-yellow insulation housing for mounting on U crewdriver ULKG 1,5 N 30 05 85 3 50 Z 0,4 x 2,5 12 05 03 7 10 ULKG 2,5 N ULKG 2,5 N-1 Z 0.6 x 3.5 04 41 11 9 50 04 43 08 1 50 1205053 10 Zack marker strip, 10-section White ZB 4 (for order data, see page 396) ZB 5 (for order data, see page 397) Dimensions Width length Height (N 3517.5 / N 35/15? N 32) Technical data in accordance with IEC / DIN VDE Rated surge voltage / contamination class [kv] / - urge voltage category / insulating material group - / - Connection capacity tranded with ferrule without! with plastic sleeve [mm) Multi-conductor connection (2 cond. with same cross section) olid / stranded [mm, ] tranded with ferrules without plastic sleeve tranded with TWIN ferrule with plastic sleeve [mm/] tripping length Internal cylindrical gauge (IEC 60 947-1) Terminal point : Thread / torque Fastening : Thread / torque Insulation material Inflammability class in acc. with UL 94 Approval data (UUCUL and CA) Conductor sizes [mm) [mm) - / [Nm] - / [Nm] UL/CUL : [V] / [A] / AWG CA : [V] / [A) / AWG 4.2 / 42.5 42/49.5/47 6/3 II/I 0.25-0.75/0.25-0.75 0.14-0.75/0.14-0.75 0.25-0.34 0.5 7 Al M2 / 0.22-0.25 M2/0.22-0.25 30-14 ') For information on instaltation and usage of accessories for EEx e applications. see page 508. 5.2 / 42.5 42 / 49.5 / 47 III/I 0.25-2.5 / 0.25-1.5 0.2-1/0.2-1 0.25-1.5 0.5-1.5 7 A3 M3/0.6-0.8 M2.5 / 0.5-0.6 30-12 28-12 Universal ground terminal blocks ULKG...-1 ULKG This ULKG version has been specially developed for the N 35/15-2,3 mounting rail. N 32 UNGELOCHT N 32 GELOCHT In acc. with EN 60 715 In acc. with EN 60 715 N 32-CU/35 OMM UNGELOCHT Dimensions in acc. with EN 60715 N 32-AL UNGELOCHT similar to EN 60 035 N 32-CU/120 OMM UNGELOCHT similar to EN 60 035 216 Phoenix Contact

l ULKG 3 ULKG 5 ULKG 6 N Terminal width 5.2 DEC) rigid flexible [mm 2 ] solid stranded AWG IEC 60 947-7-2 0.2-4 0.2-2.5 24-12 IEC 60 947-7-2 0.2-6 0.2-4 24-10 0 EN 50 019' 0.2-4 0.2-2.5 24-12 EN 5D 019 `.2-6 0.2-4 24-12 EU type-examination certificate no. : KEMA 97ATEX1622U ') ' EU type-examination certificate no. : KEMA 99ATEX4487U ') For current carrying capacity of mounting rails, see page 499. For current carrying capacity of mounting rails, see page 499. r~us @ K(.CCA KEMA J c%us BV/LR/NV/PR/AB Order No. Terminal width 6.2 [mm2] solid stranded AWG c%ius P KE3Rl CCA B P BV/LR/NV/PR/R/AB Ex KEMA Maus Terminal width 8.2 [mm, ] solid stranded AWG IEC 60 947-7-2 0.2-10 0.2-6 24-8 EN 50 019` 0.2-10 0.2-6 24-8 EU type-examination certificate no. : KEMA 96ATEX4370U ') For current carrying capacity of mounting rails, see page 499. c'klus [KEN. CCA `B Ex KEMA :C ' c%us FTZU P BV/LR/NV/PR/AB ULKG 3 04 41 08 3 50 ULKG 5 04 41 50 4 50 ULKG 6 N 04 42 07 9 50 ULKG 3-1 04 41 10 6 50 ULKG 5-1 04 41 51 7 50 ULKG 6 N-1 04 44 04 8 50 Z0,6x3.5 1205053 10 Z0.6x3.5 1205053 10 Z 1,0 x 4,0 12 05 06 6 10 ZB 5 (for order data, see page 397) ZB 6 (for order data, see page 397) ZB 8 (for order data, see page 399) 5.2 / 42.5 47/54.5/52 1 III / 0.25-2.5/0.25-1.5 0.2-1.5/0.2-1.5 0.25-1.5 0.5-1.5 8 A3 M3/0.6-0.8 M2.5 / 0.5-0.6 Vo 28-12 28-12 2) When aligning with feed-through terminal blocks with the same shape. an end cover must be interposed with insulation voltages of > 500 V 6.2 / 42.5 47/54.5/52 III / I 0.25-4/0.25-2.5 0.2-1/0.2-1.5 025-1.5 0.5-2.5 8 A4 M3 / 0.6-0.8 M3 / 0.6-0.8 26-10 28-10 8.2 / 42.5 47 / 54.5 / 52 1 III / I 0.25-6/0.25-6 0.2-2.5 / 0.2-2.5 0.25-1.5 0.5-4 10 A M4/1.5 1.8 M4/1.5 1.8 26-8 ULKG... -1 N3517.5 UNGELOCHT N 35/7,5 GELOCHT In acc. with EN 60 715 In acc. with EN 60 715 1 1 35f7.5-CU GELOCHT Dimensions in acc. with EN 60 715 N 35/15 UNGELOCHT N 35/15 GELOCHT similar to EN 60 035 similar to EN 60 715 N 35/15-CU UNGELOCHT similar to EN 60 035 N 35/15-2.3 N 35/15-AL UNGELOCHT UNGELOCHT In acc. with EN 60 715 similar to EN 60 035 Phoenix Contact 217

Universal ground terminal blocks, ULKG.44 1 ~i d 4 y f r' f [.. 4.. 1 ULKG 10 N Terminal width 10.2 (mm ] solid stranded AWG [A] IEC 60 947-7-2 0.5-16 0.5-10 20-6 76 EN 50 019' 0.5-16 0.5-10 20-6 EU type-examination certificate no. : KEMA 99ATEX4487U ') For current carrying capacity of mounting rails, see page 499. ULKG 16 N Terminal width 12.2 [mm2 ] solid stranded AWG [A] IEC 60 947-7-2 2.5-25 4-16 12-4 101 EN 50 019-2.5-25 4-16 12-4 - - EU type-examination certificate no.: KEMA 99ATEX4487U ') For current carrying capacity of mounting rails, see page 499. c~us P KE,'aI CCA B P ' s_)1 BV/LR/NV/PR/AB Ex KEMA/FTZU :zau. rv us p 'B P (nl BVILR/NV/PR/R/NK fx KEMA ' c%us FTZU Description Color PCs. pos. Ground terminal block, with green-yellow insulation housing, for mounting on r~oru Ground terminal block, with green-yellow insulation housing for mounting on U Ground terminal block, with green-yellow insulation housing, for mounting on E_>, Li or 1_1 Insertion profile, levels out the prism-shaped sleeve when using flat conductors, see table on page 336 ULKG ION 30 03 92 3 50 ULKG 10 N-1 04 42 08 2 50 ULKG 16 N ULKG 16 N-1 04 43 02 3 50 04 43 03 6 50 crewdriver Allen wrench F- Z 1,0 x 4,0 12 05 06 6 10 Z1,0x4,0 1205066 17 Zack marker strip, 10-section White Dimensions Width / length Height (N 35/7.5 / N 35/15 / N 32) Technical data in accordance with IEC / DIN VDE [mm) Maximum load current! cross section [A] / [mm 2] Rated surge voltage / contamination class [kv] / urge voltage category / insulating material group / Connection capacity tranded with ferrule without / with plastic sleeve [mm 2] Multi-conductor connection (2 cond. with same cross section) olid! stranded [mm 2] tranded with ferrules without plastic sleeve [mm 2] tranded with TWIN ferrule with plastic sleeve [mm""-] tripping length Internal cylindrical gauge (IEC 60 947. 1) Terminal point: Thread / torque / [Nm] Fastening : Thread / torque /[Nm] Insulation material Inflammability class in acc. with UL 94 Approval data (UL/CUL and CA) Conductor sizes UL/CUL : [V] / [A]! AWG Universal ground terminal blocks, ULKG...-1 CA : [V] / [A]! AWG 10.2 / 42.5 47/54.5/52 76/16 III/I 0.5-10/0.5-6 0.5-4/0.5-0.4 0.5-2.5 0.5-6 10 B6 M4/1.5-1.8 M4!1.5-18 24-6 24-6 ') For information on installation and usage of accessories for EEx e applications, see page 508. 12.2 / 42.5 54/61.5/59 101 /25 III/I 1.5-16/1.5-16 1.5-6/1.5-4 1.5-6 0.75-10 11 B7 M4/1.5-1.8 M4 / 1.5-1.8 22-4 22-4 2 ) crews with hexagonal socket-head. ULKG This ULKG version has been specially developed for the N 35115-2,3 mounting rail. 218 Phoenix Contact N 32 UNGELOCHT N 32 GELOCHT In acc. with EN 60 715 In acc. with EN 60 715 N 32-CU/35 QMM UNGELOCHT Dimensions in acc. with EN 60 715 N 32-AL UNGELOCHT similar to EN 60 035 N 32-CU/120 QMM UNGELOCHT similar to EN 60 035

ULKG 35 ULKG 50 ULKG 95 Terminal width 15.2 Terminal width 20.0 Terminal width 25.0 [mm 2] solid stranded AWG [A] [mm'] solid stranded AWG [A] [mm'] solid stranded AWG [A] IEC 60 947-7-2 0.75-50 0.75-35 18-0 150 IEC 60 947-7-2 16-50 25-50 6-0 150 IEC 60 947-7-2 25-95 35-95 4-000 232 25-95 EN 50 019' 0.75-50 0.75-35 18-0 - EN 50 019-16-50 25-50 6-0 EN 50 019 ' 35-95 4-000 '-examination certificate no. : KEMA 01ATEX2046U 1) ' -examination certificate no. : KEMA 99ATEX4487U 1 ) ' -examination certificate no. : KEMA 99ATEX4487U ') For current carrying capacity of mounting rails. see page 499. For current carrying capacity of mounting rails. see page 499 For current carrying capacity of mounting rails, see page 499. clus I P a BV!LR/NV/PR/R/ABNDE-PZI KEMA clus FTZU Pos. Pkt. c~us P st BV/LR/NV/PRiR Ex KEMA clilaus FTZU Pos. Pkt. c~us B (' 61- LR/PR/R Ex KEMA c~us FTZU Order No. Pct. ULKG 35 04 44 01 9 25 ULKG 35-1 04 49 01 4 25 ULKG 50 04 43 04 9 ULKG 95 04 41 04 1 10 UKH 50 EP 3009228 10 UKH 95 EP 30 09 23 1 10 1.0x6,5 1205079 10 Z1,2x8.0 1205082 10 VDE-I 6 12 01 93 4 15.2 / 50 62 / 69.5 / 67 150 / 50 I/ 0.75-35/0.75-35 0.75-16/0.75-10 0.75-10 0.75-6 15 B9 M6/3.2-3.7 M5/2.5-3 18-1/0 18-2 20170.5-183.5/81.5 150/50 III / I 25-50/25-50 10-16/10-16 10-16 24 B10 M6/6-8 M6/6-8 6-1/0 25183 /99/96.5 232 / 95 III/I 35-95/35-95 25-35/25-35 16-35 30 B12 M8 /15-20') M8/15-20') 2-4/0 2-4/0 ULKG... -1 N 3517,5 UNGELOCHT N 35/7,5 GELOCHT In acc. with EN 60 715 In acc. with EN 60 715 N 3517.5-CU UNGELOCHT Dimensions in acc. with EN 60715 N 35/15 UNGELOCHT N 35/15 GELOCHT similar to EN 60 715 similar to EN 60 035 N 35115-CU UNGELOCHT similar to EN 60 035 N 35/15-2,3 N 35/15-AL UNGELOCHT UNGELOCHT In acc. with EN 60 715 similar to EN 60 715 Phoenix Contact 219

Twin conductor terminal blocks, UK...-TWIN UK 3-TWIN Anyone who is familiar with electrical wiring knows the problems of potential branching : in other words, the necessity of connecting two or more conductors to one modular terminal block, especially in cases where conductor type and cross section diverge considerably. This elementary task is now solved by the twin modular terminal blocks UK 5-TWIN. The features are: Two separate cable connection points on the control cabinet side Bridging in the terminal center, even with neighboring feed-through terminal blocks aligned in rows : UK 3-TWIN with UK 3 N, UK 5-TWIN with UK 5 N and UK 10-TWIN and UK 10-PLU with UK 10 N. The UK 3-TWIN and UK 5-TWIN terminal blocks are the same shape but have different pitches. If UK universal terminal blocks are aligned on the open side of the UK 3-TWIN and UK 5-TWIN terminal blocks, the exposed metal part must be closed using the UK 5-TWIN cover segment, five of which are enclosed in each pack. The UK 10-TWIN has two 10 mm 2 connection facilities, the UK 10-PLU has a connection for looping a 10 mm 2 supply line and a 4 mm2 pick-off. In addition, the UK 10-TWIN and UK 10-PLU can be bridged in the terminal center, even with the normal feed-through terminal blocks, UK 10 N. All terminal blocks have a universal foot for mounting on oru DIN rails. ') For information on installation and usage of accessories for EEx e applications. see page 508. Description Terminal block, with universal foot for reversible mounting on L) or Lr (1) Cover (2) Fixed bridge, for cross connections in the terminal center, screw heads with insulating collar, 10-position, divisible, with 10 screws (4) Isolator bridge bar, 10-position, divisible, with 10 screws, for switchable branches with (5) Bridge bar I-K... as distance piece (6) eparating disk, for electrical separation of neighboring bridges, can be fitted later, no loss of pitch (7) Test socket, for test connection with test plug MP or reducing plug RP (8) Test socket, insulated, only used with FBI, IBI, for test connections with test plug MP or RP (9) crewdriver Color Gray Blue Gray Blue (3) Insertion bridge, fully insul., 2-pos. 1 ] fully insulated. 3-pos. divisible, insulated spine, 10-pos. t Terminal width 5.2 I U [mm z ] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-2.5 0.2-2.5 24-14 24* 400 * The max. load current must not be exceeded by the total current of all connected conductors. c91lus P K] ( CCA p sit LR/PR (10) Zack marker strip, 10-section White ZB 5 (for order data, see page 397) Dimensions Width / length / cover width 5.2/50.5/2 Height (N 357.5 / N 35/151 N 32) 47/54.5!52 Technical data in accordance with IEC / DIN VDE Continuity: Max. load current! cross section [A]/[mm 2] 24 / 2.5 Pick-off : Max. load current / cross section [A)/[mm2] Max. cross section with insertion bridge (solid/stranded) [mm2] 2.5/2.5 Rated surge voltage / contamination class [kv) / - 6/3 urge voltage category / insulating material group -le 111/1 Connection capacity continuity tranded with ferrule without / with plastic sleeve [mm z] 0.25-1.5/0.25-1 T-K PB 3/10/4 PBJ 3/13/4 Z 0,6 x 3,5 Connection capacity pick-off tranded with ferrule without / with plastic sleeve [mm2] Continuity : Two conductors with same cross section olid / stranded [mml 0.2-0.5/0.2-0.5 tranded with ferrules without plastic sleeve [mm z] 025-0.5 tranded with TWIN ferrule with plastic sleeve [mm2] 0.5-075 Pick-off : Two conductors with same cross section olid I stranded tranded with ferrules without plastic sleeve tranded with TWIN ferrule with plastic sleeve tripping length : Continuity / pick-off [mm z] [mm 2] [mm-] 8/- A3/- Internal cylindrical gauge (IEC 60 947-1) Continuity / pick-off Continuity : Thread / torque -I [Nm] M3/0.5-0.6 Pick-off : Thread/torque - [Nm] Insulation material Inflammability class in acc. with UL 94 V2 Approval data (UL/CUL and CA) Nominal voltage. current! conductor sizes UL/CUL : [VI/ [A] / AWG 150/20/30-12 UL/CUL : [VI/ [A] / AWG 300/10/30-12 CA : ]V] / [A]! AWG 300/20/28-12 CA [V]/[A]!AWG l It.1 [.1[ Il f P.TI UK 3-TWIN UK 3-TWIN BU D-UK 5-TWIN D-UK 5-TWIN BU FBRI 10-5 N 24 A I EBL 2-5 I,, :24A EBL 3-5 24 A EBL 10-5 24 A 30 02 22 5 50 30 02 41 6 50 19 23 03 4 50 1923050 50 27 70 64 2 2303145 10 2303158 10 2303132 10 1302215 50 06 01 29 2 100 02 01 30 4 100 12 05 05 3 10 220 Phoenix Contact

UK 5-TWIN UK 10-TWIN UK 10-PLU Terminal width 6.2 Terminal width 10.2 I U I U [mm 2 ] solid stranded AWG [A] [V] [mm2] solid stranded AWG [A] [V] 1EC60947-7-1 0.2-4 0.2-4 24-12 32* 500 1EC60947-7-1 0.5-16 0.5-10 20-6 76' 800 EN 50 019" 0.2-4 0.2-4 24-12 32* 275 The max. load current must not be exceeded by the total current "EU type-examination certificate no. : KEMA 00ATEX2100U ') of all connected conductors. ' The max. load current must not be exceeded by the total current of all connected conductors. % l CCA B P /' LR/PR/NK ) KEMA :Z.: AL: c~us P CCA P PR Order No. PC Pkt UK5-TWIN 1923021 50 UK 10-TWIN 3005196 50 UK 5-TWIN BU 1923047 50 UK 10-TWIN BU 3005235 50 Terminal width 10.2 I U [mm 2] solid stranded AWG [A] [V] IEC 60 947-7-1 Continuity 0.5-16 0.5-10 20-6 76* 800 Pick-off 0.2-6 0.2-4 24-10 41` 800 - The max. load current must not be exceeded by the total current of all connected conductors. cvlus P,..e ; P PR Order No. UK 10-PLU 30 01 38 1 50 UK 10-PLU BU 30 01 47 5 50 D-UK 5-TWIN 19 23 03 4 D-UK 5-TWIN BU 1923050 50 50 F8l 10-6 I, : 32 A 02 03 25 0 10 FBI 10-10 I,,,, : 76 A 02 03 27 6 10 FBI 10-10 I, : 76 A 02 03 27 6 10 EB 2-6 32 A 02 01 15 5 ' 100 EB 3-6 32 A 02 01 14 2 100 3iO-6 32A 0201139 10 i 110-6 : 24 A 03 01 50 5 10 K4 1302338 100 IBI 10-10 1.,,a, : 57 A 03 01 52 1 I-K 10 13 03 33 7 10 IBI 10-10 100 I-K 10 I,,_,, : 57 A 0301521 10 13 03 33 7 100 T-K 13 02 21 5 50 T-KK 3 27 70 21 5 50 T-KK 3 2770215 50 PB 3110/4 06 01 29 2 100 PB 4/7/6 03 03 29 9 100 PB 4/7/6 03 03 29 9 100 PBJ 3/1314 02 01 30 4 100 PBJ 4/15/6 :... (for order data, see page 390) Z 0,6 x 3,5 12 05 05 3 10 Z 1,0 x 4,0 ZB 6 (for order data, see page 397) 6.2/50.5/2 10.2/56.5/- 47/54.5/52 59/66.5/64 32/4 76/16 4/ - 4-6/3 III / I Ill / I 0.25-4/0.25-2.5 0.5-10/0.5-6 0.2-1.5/0.2-1.5 0.5-4/0.5-4 0.25-1.5 0.5-2.5 0.5-1.5 0.5-4 12 05 06 6 10 Z 1,0 x 4,0 PBJ 4/15/6:... (for order data, see page 390) 10.2/53/ 47/54.5/52 76 / 16 41/6 III/I 0.5-10/0.5-6 0.25-4 / 0.25-4 0.5-4/0.5-4 0.5-2.5 0.5-4 1205066 10-8/ - 11/- A4/- B6/- M3/0.6-0.8 M4/1.5-1.8 V2 150/30/30-10 300/10/30-10 300/30/22-10 300/65/24-6 600/65 - /24-6 0.2-1.5/0.2-1.5 0.25-1.5 0.5-1.5 11/7 B6/A4 M4/1.5-1.8 M3/0.6-0.8 600 / 65 / 24-6 Feed-through 600 / 20 / 30-12 Pick-off 600 / 65 / 24-6 Feed-through 600 / 20 / 28-12 Pick-off Phoenix Contact 221

Twin ground terminal blocks UK...-TWIN-PE and UK 10-PLU-PE UK 3-TWIN-PE Terminal width 5.2 [mm2 ] solid stranded AWG IEC 60 947-7-2 0.2-2.5 0.2-2.5 24-14 For current carrying capacity of mounting rails, see page 499. The green-yellow closed housing with its characteristic UK-TWIN shape can be aligned conveniently with the UK-TWIN series models. Through the housing cutout in the ground terminal block, the bridges LB..., and IBI 10-6 can be connected to the neighboring UK, UK-TWIN, and UK-PLU variants with a bridging facility. The universal grounding foot allows the terminal block to be mounted on both commercially available EN mounting rails (with the exception of N 35/15-2.3). Description Ground terminal block, for mounting on v or Lr crewdriver Zack marker strip, 10-section Dimensions Width / length Height (N 35/7.5 / N 35/15 I N 32) Color Green-yellow White Technical data in accordance with IEC / DIN VDE Continuity : Max. load current / cross section [A]/[mm2 ] Pick-off : Max. load current / cross section [A]/[mm'] Rated surge voltage / contamination class [kv] / - urge voltage category / insulating material group - / - Connection capacity continuity tranded with ferrule without / with plastic sleeve [mm2 ] Connection capacity pick-off tranded with ferrule without / with plastic sleeve [mm, ] Continuity: Two conductors with same cross section olid / stranded [mm[] tranded with ferrules without plastic sleeve [mm2 ] tranded with TWIN ferrule with plastic sleeve [mm2 ] Pick-off : Two conductors with same cross section olid / stranded [mm[] tranded with ferrules without plastic sleeve [mm[] tranded with TWIN ferrule with plastic sleeve [mm[] tripping length : Continuity / pick-off Internal cylindrical gauge (IEC 60947-1) continuity / pick-off Continuity : Thread! torque Pick-off: Thread / torque Insulation material Inflammability class in acc. with UL 94 Approval data (UUCUL and CA) Conductor sizes - / [Nm] - / [Nm] UUCUL : AWG AWG CA : AWG AWG ~us B P PR -71 UK 3-TWIN-PE 19 23 12 8 50 Z 0,6 x 3,5 12 05 05 3 10 ZB 5 (for order data, see page 397) 5.2 / 50.5 47/54.5/52 6/3 III / 0.25-1.5/0.25-1 0.2-0.5/0.2-0.5 025-0.5 0.5-0.75 30-12 0 Of f 222 Phoenix Contact

UK 5-TWIN-PE UK 10-TWIN-PE UK 10-PLU-PE Terminal width 6.2 [mm2 ] solid stranded AWG Terminal width 102 [mm?] solid stranded AWG [A] Terminal width 10.2 [mm2 ] solid stranded AWG [A] IEC 60 947-7-2 0.2-4 0.2-4 24-12 IEC 60 947-7-2 0.5-16 0.5-10 20-6 76' IEC 60 947-7-2 For current carrying capacity of mounting rails, see page 499. ` The max. load current must not be exceeded by the total current Continuity 0.5-16 0.5-10 20-6 76' of all connected conductors. Pick-off 0.2-6 0.2-4 24-10 41' For current carrying capacity of mounting rails, see page 499 ` The max. load current must not be exceeded by the total current of all connected conductors. For current carrying capacity of mounting rails, see page 499. Alaus KfI CCA B t' LR/NKIPR c%us P Kc " w CCA B P PR Fkl. Pcs. Pkt. A.1 us 3B r' PR P c. UK 5-TWIN-PE 1923076 50 UK 10-TWIN-PE 30 01 43 3 50 UK 10-PLU-PE 30 01 42 0 50 Z 0.6 x 3.5 12 05 05 3 10 Z 1.0 x 4.0 1205066 10 Z 1.0 x 4.0 12 05 06 6 10 ZB 6 (for order data. see page 397) ZB 10 (for order data, see page 397) ZB 10 (for order data, see page 397) 6.2 / 50.5 10.2 / 56.5 10.2 / 53 47 / 54.5 / 52 59/66.5164 47/54.5152 6/3 III /I 76/16 III / I 76 / 16 41/6 III/I 0.25-4 / 0.25-2.5 0.5-10/0.5-6 0.5-10/0.5-6 0.25-4/0.25-4 0.2-1.5 / 0.2-1.5 0.5-4/0.5-4 0.5-4/0.5-4 0.25-1.5 0.5-2.5 0.5-6 0.5-1.5 0.5-4 0.5-6 0.2-1.5/0.2-1.5 0.25-1.5 0.5-1.5 8/- 11/- 11/7 A4 / - B6/- B6/A4 M3 / 0.6-0.8 M4/1.5-1.8 M4/ 1.5-1.8 M3 / 0.6-0.8 V2 30-10 24-6 24-6 24-6 Feed-through 30-12 Pick-off 24-6 Feed-through 28-12 Pick-off Phoenix Contact 223

Double terminal blocks, UDK In practice, several connections often have to be led onto one terminal block as a result of potential distribution or conductor loops. The UDK double terminal block family solves this problem elegantly, as two connection points are available to accommodate several conductors on each module. The particular features of the 5 mm wide UDK 3 and UDK 4 terminal blocks of the same shape include: Potential branching using 2 terminal points on each connection side Two bridging points in the terminal center through which two potentials in the bridge shafts can be supplied to the whole terminal strip. Ground terminal block, UDK 4-PE The green-yellow closed housing with its characteristic UDK shape can be conveniently aligned with all types of the UDK family. The IBI 10-6 bridge can be connected with neighboring UDK 4 variants with bridging facilities through the cutouts in the ground terminal block housing. The universal grounding foot allows the terminal blocks to be mounted on both commercially available EN mounting rails. Description Terminal block, with universal foot for mounting onvor u Ground terminal block, for mounting on L, or Lr Cover Color Gray Blue Green-yellow Fixed bridge, for cross connections in the terminal center, screw heads with insulating collar, 10-position, divisible. with 10 screws Fixed bridge, for cross connections in the terminal center, with permanently crimped rolls, screw heads with insulating collar as shock protection 2-pos. 3-pos. 4-pos. 10-pos. Insertion bridge, fully insulated, 2-pos. fully insulated, 3-pos. divisible, insulated spine, 10-pos. Isolator bridge bar, for switchable branches, 10-position, divisible, with 10 screws Bridge bar I-K 4 as distance piece witch bar for 2 terminal blocks, complete, to increase insulation an end cover must be interposed eparating disk, for electrical separation of neighboring bridges. can be fitted later, no loss of pitch crewdriver Gray Blue rttrnrli a a F.i UDK 3 Terminal width 5.2 I U [mm 2] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-4 0.2-2.5 24-12 32' 500 ' The may. load current must not be exceeded by the total current of all connected conductors. c%us B P PR UDK 3 27 75 37 5 D-UDK 4 27 75 11 3 5o FBRI 2-5 N : 26 A 30 00 22 7 FBRI 3-5 N 26 A 30 00 20 1 10 FBRI 4-5 N 26 A 30 00 19 1 10 FBRI 10-5 N 26 A 27 70 64 2 to EBL 2-5 I,,,,, : 26 A 23 03 14 5 to EEL 3-5 26 A 23 03 15 8 to EBL 10-5 26 A 23 03 13 2 10 T-KK 3 2770215 50 Z 0,6 x 3,5 1205053 to 50 Zack marker strip, 10-section White ZB 5 (for order data, see page 397) Note If the LB..., IBI 10-6 or FB-150 bridges are wired across UDK... terminal blocks with a different potential, the insulation voltages between bridge and feed-through terminal blocks are reduced to 500 V and between bridge and ground terminal blocks to 250 V. 224 Phoenix Contact Dimensions Width / length / cover width Height (N 35/7.51 N 35/151 N 32) Technical data in accordance with IEC / DIN VDE Max. load current / cross section [A[/[mm2] Max. cross section with insertion bridge (solid/stranded) [mm2] Rated surge voltage / contamination class [kv] / urge voltage category / insulating material group / Connection capacity tranded with ferrule without 1 with plastic sleeve [mm-] Multi-conductor connection (2 cond. with same cross section) olid / stranded [mm''] tranded with ferrules without plastic sleeve [mm''] tranded with TWIN ferrule with plastic sleeve [mm'-] tripping length Internal cylindrical gauge (IEC 60 947-1) Terminal point: Thread I torque Terminal point: Thread / torque Insulation material Inflammability class in acc. with UL 94 Approval data (UL/CUL and CA) / [Nm] / [Nm] 5.2 / 63.5 / 1.5 47/54.5/52.5 32/4 2.5 / 2.5 6/3 III/I 0.25-2.5/0.25-1.5 02-1/0.2-1.5 025-1.5 0.5-1 8 A3 M3/0.6-0.8 Nominal voltage i current ; conductor sizes UL/CUL : [V] / [A] / AWG 300/20/30-12 CA : [VI/ [A] / AWG 300/20/28-12 [V]/[A]/AWG V2

UDK 4 UDK 3-PE UDK 4-PE..,, Hal width 62 Terminal width 5.2 IEC) rigid flexible I U mm-i solid stranded AWG [Al [V] [mm 2 ] solid stranded AWG Terminal width 6.2 [mm ) solid stranded AWG C 60 947-7-1 0.2-6 0.2-4 24-10 32' 630 IEC 60 947-7-2 0.2-4 0.2-2.5 24-12 IEC 60 947-7-2 0.2-6 0.2-4 24-10 The max. load current must not be exceeded by the total current For current carrying capacity of mounting rails, see page 499. For current carrying capacity of mounting rails, see page 499. of all connected conductors. ~us P K B e ' P BV/NV/PR/R c%us B P PR c%us P ' BV/PR/R 'pe Order No. Order No. Pkt. ]K 4 3K4BU 27 75 01 6 2775090 50 50 I UDK 3-PE 27 75 45 6 50 UDK 4-PE 27 75 18 4 50.UDK 4 UDK 4 BU 27 75 11 3 27 75 19 7 50 50 31 10-6 1,,,H : 34 A 02 03 25 0 10 3 2.6 I,,,,. : 26 A 02 01 15 5 100 3 3-6 26 A 02 01 14 2 100 310-6 26 A 02 01 13 9 10 BI 10-6 I,,, : 34 A 03 01 50 5 10 -K4 1302338 100 BR 2-7 I m,24 A 23 03 23 9 1 3-KK 3 27 70 21 5 50 Z 0,6 x 3,5 1205053 10 Z 0,6 x 3,5 1205053 10 Z0,6x3,5 1205053 10 B 6 (for order data, see page 397) ZB 5 (for order data, see page 397) ZB 6 (for order data, see page 397) 6.2/63.5/1.5 47 / 54.5 / 52 32/6 2.5 / 2.5 III / I 0.25-4 / 0.25-1.5 5.2/63.5/- 6.2/63.5/- 47 ; 54.5 / 52.5 47/54 5/ 52.5 6/3 III/I III/I 0.25-2.5/0.25-1.5 0.25-4/0.25-1.5 0.2-1/0.2-1.5 0.2-1/0.2-1.5 0.25-1.5 0.25-1.5 0.5-1 0.5-1 8 8 A4 A3 M3/0.6-0.8 M3/0.6-0.8 M2.5/0.5-0.6 V2 V2 0.2-1/0.2-1.5 025-1.5 0.5-1 8 A4 M3/0.6-0.8 M3/0.6-0.8 V2 300/30/30-10 300/35/30-10 300/25/22-10 -/-/30-12 -/-122-10 -/-'22-10 Phoenix Contact 225

Universal return terminal blocks, UK... -RETURN The UK-RETURN universal terminal blocks are feed-through modular terminal blocks which have both connections on one side. The contact metal is looped back. The double connection on one side of the terminal block allows two conductors to be connected from one side. This means that two terminal strips can be installed back to back, thereby saving considerable space. A further advantage is the possibility of positioning the terminal blocks against the wall of a control cabinet. In this way, every last corner of the cabinet can be used. This is an optimum supplement to the standard feed-through terminal blocks for machine wiring. Description Terminal block, with universal foot for mounting on v or LJ Ground terminal block, for mounting on E or Lr Cover Color Green-yellow Fixed bridge, for cross connections in the terminal center. screw heads with insulating collar, 10-position, divisible, with 10 screws Gray Blue =CUE Fixed bridge, for cross connections in the terminal center, with 2-pos. permanently crimped rolls, screw 3-pos. Ouuulllllllll~l II heads with insulating collar as shock 4-pos. protection 10-pos. [IDIIII]Fll1 Insertion bridge, fully insul., 2-pos. fully insulated, 3-pos. gi divisible, insulated spine 10-pos. eparating disk, for electrical separation of neighboring bridges, can be fitted later, no loss of pitch Partition plate, for visual and electrical separation of terminal groups. 1.5 mm thick crewdriver Gray Blue [111111 UK 3-RETURN Terminal width 5.2 I U [mm,] solid stranded AWG [A] [V] IEC 60 947-7-1 0.2-4 0.2-2.5 24-12 32 50C EN 50 019' 0.2-4 0.2-2.5-23/30 27.E. ' Certificate no.: KEMA Ex-92.C.9175U') P ' e P PR G KEMA Pos. UK 3-RETURN 30 02 51 3 50 UK 3-RETURN BU 30 02 56 8 50 D-UK 3-RETURN 30 02 53 9 50 D-UK 3-RETURN BU 30 02 57 1 50 FBRNI 2-5 N : 32 A 3000175 FBRNI 3-5 N 32 A 3000162 10 FBRNI 4-5 N 32 A 3000159 10 FBRNI 10-5 N 32 A 27 70 63 9 10 EB2-5 1,,,,,24 A 1401158 100 EB 3-5 24 A 14 01 14 5 100 EB 10-5 24 A 14 01 13 2 10 T-UK 3-RETURN 30 02 52 6 50 ATP-UK 3-RETURN 30 02 54 2 50 Z 0,6 x 3,5 1205053 10 Zack marker strip, 10-section White ZB 5 (for order data, see page 397) o Dimensions Width / length / cover width Height (N 35/7.5 / N 35/15 / N 32) Technical data in accordance with IEC / DIN VDE Max. load current / cross section [A]1[mm/] Max. cross section with insertion bridge (solid/stranded) [mm r ] Rated surge voltage / contamination class [kv] / - urge voltage category/insulating material group - / - 5.2 / 47.5 / 1.5 58.5 / 66 / 63.5 Connection capacity tranded with ferrule without / with plastic sleeve [mm'] 0.25-2.5/0.25-1.5 Multi-conductor connection (2 cond. with same cross section) olid.' stranded [mm-] 0.2-1/0.2-1 tranded with ferrules without plastic sleeve [mm 5] 025-1 tranded with TWIN ferrule with plastic sleeve [mm5] 0.5-1 tripping length 8 Internal cylindrical gauge (IEC 60 947-1) A3 Terminal point : Thread / torque Fastening : Thread / torque Insulation material - / [Nm] - / [Nm] M3/0.6-0.8 Inflammability class in ace. with UL 94 V2 Approval data (UUCUL and CA) Nominal voltage i current ; conductor sizes UUCUL: [V] 1[A] / AWG 300/20/30-12 CA: [V] / [A] / AWG 300 / 25 / 28-12 32/4 4/2.5 6/3 III / I ') For information on installation and usage of accessories for EEx e applications. see page 508-226 Phoenix Contact

UK 5-RETURN UK 3-RETURN-PE UK 5-RETURN-PE Terminal width 6.2 I U [mm2] solid stranded AWG (A] [V] IEC 60 947-7-1 0.2-6 0.2-4 24-10 41 500 Terminal width 5.2 [mm'] solid stranded AWG IEC 60 947-7-2 0.2-4 0.2-2.5 24-12 EN 50 019' 0.2-4 0.2-2.5 24-12 ' Certificate no.. KEMA Ex-93.C.6783U') For current carrying capacity of mounting rails. see page 499. Terminal width 6.2 [mm2] solid stranded AWG IEC 60 947-7-2 0.2-6 0.2-4 24-10 For current carrying capacity of mounting rails, see page 499. p B P LR/NV/PR 9 yp,e p Ex KEMA B B P LR/NV/RP 110 ' UK 5-RETURN 30 02 59 7 50 UK 5-RETURN BU 30 02 49 0 50 UK 3-RETURN-PE 30 02 55 5 50 UK 5-RETURN-PE 30 02 58 4 50 D-UK 3-RETURN D-UK 3-RETURN BU FBI 10-6 30 02 53 9 50 30 02 57 1 50 1,, 33 A 02 03 25 0 10 EB2-6 l :33A 0201155 100 E6 3-6 33 A 1 02 01 14 2 100 EB10-6 33A 0201139 10 T-UK 3-RETURN 30 02 52 6 50 ATP-UK 3-RETURN 30 02 54 2 1 50 Z 0,6 x 3.5 1205053 10 Z 0,6 x 3,5 1205053 10 Z O,6 x 3,5 12 05 05 3 10 ZB 6 (for order data, see page 397) ZB 5 (for order data, see page 397) ZB 6 (for order data, see page 397) 6.2/47.5/1.5 58.5/ 66 / 63.5 5.2 / 42.5 58.5 / 66 / 63.5 6.2 / 42.5 58.5 / 66 / 63.5 41/6 4/4 6/3 III/I 6/3 III/I 0.25-4 / 0.25-2.5 0.25-2.5 / 0.25-1.5 0.25-4/0.25-2.5 0.2-1.5/0.2-1.5 025-1.5 0.5-1.5 8 A4 M3/0.6-0.8 V2 0.2-1/0.2-1 025-1 0.5-1 8 A3 M3/0.6-0.8 M3/0.6-0.6 V2 0.2-1.5/0.2-1.5 0.25-1.5 0.5-1.5 8 A4 M3/0.6-0.8 M3 / 0.6-0.8 V2 300/30/30-10 300/40/28-10 -/-/30-12 -1-128-12 - /-130-10 - /-/28-10 Phoenix Contact 227

Bridgeable PE/N power blocks UK...-PEIN Evinminlrim UK 6 N-PE/N Terminal width 16.4 I U [mm2 ] solid stranded AWG [A] [V] IEC 60947-7-1/2 0.2-10 0.2-6 24-8 57 250 For current carrying capacity of mounting rails, see page 499. When connecting electrical machine controls installed in a 5-conductor system to the power supply at the site of installation, it is impossible to know in advance whether the connection will involve 4 or 5 conductors. This task is performed by the UK...-PEIN input block. It consists of a green-yellow ground terminal block and a blue neutral terminal block. These are linked together by a special bridge which can be easily removed. The operating current of the threephase system is fed via this current bridge. A copper DIN rail is not required as this serves solely as a grounding bus (PE) when the power block is used and can therefore be made of steel. Please observe the maximum permissible short-circuit current of the DIN rail for the PE function (see page 499). When removing the bridge, the fixing screw on the ground terminal block is loosened and then firmly retightened with the small bracket and the spring washer. This is absolutely necessary to ensure perfect contact with the DIN rail. The UK...-1-PE/N terminal block has been specially developed for the N 35/15-2.3 DIN rail. Example connection for PENN input blocks Description PEN power block, consisting of green-yellow ground (PE) terminal block and blue neutral terminal block with removable special bridge connection. for mounting on v, U. u PUN power block, consisting of green-yellow ground (PE) terminal block and blue neutral terminal block with removable special bridge connection, for mounting on Lf eparating plate, for electrical separation of neighboring bridges, can be fitted later, no loss of pitch crewdriver Zack marker strip, 10-section, White Dimensions Width! length Height (N 35/7.5! N 35/15! N 32) Technical data in accordance with IEC / DIN VDE Max. load current / cross section [A]/[mm-] Rated surge voltage / contamination class [kv] / - urge voltage category! insulating material group - - Connection capacity tranded with ferrule without / with plastic sleeve [mm'] Multi-conductor connection (2 cond. with same cross section) olid / stranded [mm-'] tranded with ferrules without plastic sleeve tranded with TWIN ferrule with plastic sleeve [mm-'] tripping length Internal cylindrical gauge (IEC 60 947-1) Terminal point : Thread / torque - / [Nm] Fastening : Thread / torque - / [Nm[ Insulation material Inflammability class in acc. with UL 94 Approval data (UUCUL and CA) Nominal voltage current conductor sizes UUCUL [V] / [A] / AWG CA : [V] [Nil AWG Order No. EQ. UK 6 N-PEIN 30 24 75 3 10 UK 6 N-1-REIN 30 24 49 4 10 T-K 13 02 21 5 50 Z 1,0 x 4,0 1205066 10 ZB 8 (tor order data, see page 399) 16.4 / 42.5 47 / 54.5 / 52 57/10 6/3 Ill/I 0.25-6/0.25-6 0.2-2.5 / 0.2-2.5 0.25-1.5 0.5-4 10 A M4/1.5-1.8 M4 /1.5-1.8 228 rl ntact

UK 10 N-PE/N UK 16 N-PE/N UIK 16-PE/N Terminal width 20.4 U [mm2] solid stranded AWG [A] [V] Terminal width 24.4 Terminal width 24.4 I U I U [mm 2] solid stranded AWG [A] [V] [mm2] solid stranded AWG [A] [V] IEC 60 947-7-1/2 0.5-16 0.5-10 20-6 76 250 IEC 60 947-7-1/2 2.5-25 4-16 12-4 101 690 IEC 60 947-7-1/2 2.5-25 4-16 12-4 101 400 For current carrying capacity of mounting rails, see page 499. For current carrying capacity of mounting rails, see page 499. For current carrying capacity of mounting rails, see page 499. Order No. Pkt. Order No. Pos. Pkt. UK10N-PE/N 3024740 10 UK 16 N-PE/N 30 06 17 9 10 UIK 16-PEIN 30 06 23 4 50 UK 10 N-1-PE/II 30 24 50 4 10 T-K 13 02 21 5 50 T-K 13 02 21 5 50 T-K 13 02 21 5 50 Z 1,0 x 4,0 12 05 06 6 10 Z 1,0 x 4,0 12 05 06 6 10 Z 1,0 x 4,0 12 05 06 6 10 0 (for order data. see page 399) ZB 10 (tor order data, see page 399) 20.4/42.5 24.4/42.5 24.4 / 42.5 47/54.5/52 54/61.5/59 47/54.5/52 76/16 101/25 101/25 4/3 6/3 III/I III/I III/I 0.5-10/0.5-6 1.5-16/1.5-16 1.5-16/1.5-16 0.5-4/0.5-4 1.5-6/1.5-4 1.5-6/1.5-4 0.5-2.5 1.5-6 1.5-6 0. 5-6 1.5-10 1.5-10 10 B6 M4/1.5-1.8 M4/1.5-1.8 11 B7 11 B7 M4/1.5-1.8 M4/1.5-1.8 M4/1.5-1.8 M4/1.5-1.8 Phoenix Contact 229

Bridgeable PE/N power blocks, UK...-PE/N UK 35-PE/N UIK 35-PE/N Terminal width 30.4 Terminal width 30.4 I U I U [mm % ] solid stranded AWG [A] [V] [mm'] solid stranded AWG [A] [V] IEC 60 947-7-1/2 0.75-50 0.75-35 18-0 150 690 IEC 60 947-7-1/2 0.75-35 0.75-35 18-2 125 800 For current carrying capacity of DIN rail, see page 499. For current carrying capacity of DIN rail, see page 499. Description Pis ' PE/N power block, consisting of green-yellow ground (PE) terminal block and blue neutral terminal block with removable special bridge connection, for mounting on Cam, L I, ri PE/N power block, consisting of green-yellow ground (PE) terminal block and blue neutral terminal block with removable special bridge connection, for mounting on LI Insertion profile, levels out the prism-shaped sleeve when using flat conductors, see table on page 336 eparating plate, for electrical separation of neighboring bridges, can be fitted later, no loss of pitch UK 35-PE/N UK 35. 1-PEN T-K 30 08 05 4 10 UIK 35-PE/N 30 06 19 5 10 30 08 06 7 10 13 02 21 5 50 T-K ' 13 02 21 5 50 crewdriver I..a.-- Z 1,0 x 6,5 1205079 10 Z1,0x6,5 1205079 10 Allen wrench Zack marker strip, 10-section White Dimensions Width length 30.4 / 50 30.4/55 Height (N 35/7.5 )) N 35'15 N 32) 62 / 69.5 / 67 51 / 58.5 / 56 Technical data in accordance with IEC / DIN VDE Max. load current / cross section [A[l[mm'] 150 / 50 125 / 35 Rated surge voltage / contamination class [kv] / - 813 urge voltage category / insulating material group -/ - III / I III / I Connection capacity tranded with ferrule without / with plastic sleeve [mm[] 0.75-35/ 0.75-35 0.75-35 / 0.75-35 Multi-conductor connection (2 cond. with same cross section) olid / stranded 0.75-16 / 0.75-10 0.75-16 / 0.75-10 tranded with ferrules without plastic sleeve [mm'] 0.75-10 0.75-10 tranded with TWIN ferrule with plastic sleeve [mm'] 0.75-6 0.75-6 tripping length 16 16 Internal cylindrical gauge (IEC 60 947-1) B6 B9 Terminal point : Thread / torque - / [Nm] M6 / 3.2-3.7 M6 / 3.2-3.7 Fastening : Thread I torque -1 [Nm] M5/2.5-3 M5/2.5-3 Insulation material Inflammability class in acc. with UL 94 V2 Approval data (UL/CUL and CA) Nominal voltage! current conductor sizes ULICUL : [V] / [A] / AWG 600 1150 / 18-1/0 CA : [V] / [A] / AWG -/-/18-2 - 1 230 Phoenix Contact

UKH 50-PE/N UKH 95-PE/N aa, width 40.0 [AEC) rigid flexible 1 U [mm,] solid stranded AWG [Al [V] Terminal width 50.0 1 U [mm 2] solid stranded AWG [A] [V] IEC 60 947-7-1/2 16-50 25-50 60 150 1000 IEC 60 947-7-1/2 25-95 35-95 4-000 232 1000 For current carrying capacity of mounting rails, see page 499. For current carrying capacity of mounting rails, see page 499. P c5 UKH 50-PEN 30 09 16 3 5 UKH 95-PEIN 30 09 17 6 10 UKH 50 EP 30 09 22 8 10 UKH 95 EP 30 09 23 1 10 1,2x8,0 1205082 10 VDE-I 6 12 01 93 4 1 ZB 10 (tor order data, see page 399) 40/70.5 50/83 83.5 / 81.5 99 / 96.5 150/50 232/95 III / I III / I 25-50/25-50 35-95/35-95 10-16/10-16 25-35/25-35 10-16 16-35 24 30/33 B10 B12 M6/6-8 M8/15-20') M6/6-8 M8/15-20') V2 ') crews with hexagonal socket-head. l Phoenix Contact 231

Bridge cross reference list UK 2,5 N UK 3 N UK 5 N UK 6 N UK 10 N UK 16 N UK 35 UIK 16 Page 211 Page 211 Page 211 Page 212 Page 213 Page 213 Page 213 Page 252 Isolator bridge bars IBI 10-5 IBI 10-6 IBI 10-8 3026256 03 01 50 5 03 01 53 4 I IBI 10-10 03 01 52 1 I Bridge bar isolators I-K 2,5 I-K 4 I-K 10 3026243 1302338 1303337 Cross connection bar FB 150 02 01 59 5 Distance pieces Z-6 ZR 02 01 60 5 2303608 L-bridge, 10-pos. LB 10-6 GY LB 10-6 BU 02 02 35 8 02 02 28 0 I L-bridge, 100-pos. LB 100-6 GY LB 100-6 BU 0202345 02 02 30 3 Chain bridges KB 6 02 01 47 2 KB 8 0202206 I KB 10 KB 15 02 03 20 5 02 04 25 9 I Isolator bridge bar Cross connection bar L-bridge 232 Phoenix Contact

UIK 35 UKK 3 UKKB 3 UKK 5 UKKB 5 UKKB 10 UK 3-TWIN UK 5-TWIN UK 10-TWIN UDK 3 UDK 4 Page 253 Page 238 Page 239 Page 239 Page 239 Page 240 Page 220 Page 221 Page 221 Page 224 Page 225 hain bridge c,it.ic 233

Bridge cross reference list UK 2,5 N Page 211 UK3N Page 211 UK5N Page 211 UK6N Page 212 UK 10 N Page 213 UK 16 N Page 213 UK 35 Page 213 UIK 16 Page 252 witch bars over two terminal blocks UBR 2-7 23 03 23 9 I B 2-8/13 02 02 23 5 B 2-10/15 02 03 23 4 BH 2-15 witch bars for bridged terminal groups 02 05 23 2 I UBRJ 2-7 23 05 53 8 BJ 2-8/13 03 03 28 6 BJ2-10/15 0302287 tar/delta bridges EB 3-6/T 50 20 80 7 EB 6-6/DR 50 20 25 5 I EB 3-8/T 50 20 81 0 EB 3-8/DR 50 20 76 8 I EB 3-10/T 50 20 82 3 EB 6-10/DR 50 20 77 1 I EB 3-15/T 50 20 84 9 EB6-15/DR 5020797 tep bracket TL 35/5 0204107 TL 10N/5N hort circuit plug 0204110 I K 5 23 03 54 3 K 6 03 01 54 7 K 3-6 03 09 52 3 I K 8 03 11 540 K 10 0310541 witch bar tar bridge Delta bridge.r ti o _ dllln.00 I i 111 d 01 0 234 Phoenix Cor I t '

UIK 35 UKK 3 'age 253 Page 238 UKKB 3 UKK 5 Page 239 Page 239 UKKB 5 UKKB 10 UK 3-TWIN Page 239 Page 240 Page 220 UK 5-TWIN UK 10-TWIN Page 221 Page 221 UDK 3 UDK 4 Page 224 Page 225 I I I I I I I 'p bracket hort circuit plug ~,~,.,.,,, 235