Gauges, Sight Glasses and Vacuum Breakers

Similar documents
SECTION METERS AND GAGES FOR PLUMBING PIPING

CASH VALVES TYPE G-4 PRESSURE REGULATORS

CASH VALVES TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

Gauges and Thermometers

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Valves. External Valves, Gages and Fittings. Bulletin No What options are available when stainless steel is not suitable for external parts.

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

APT14 Automatic Pump Trap Installation and Maintenance Instructions

APT10-2 Automatic Pump Trap

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

2 1 /2" Glycerin-Filled Dual Scale Vacuum Gauges

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Hopkinsons CONTENTS SCHEDULE OF SHELL BOILER MOUNTINGS. Hopkinsons. Safety Valves 5. Boiler Stop Valves 17. Feed Check Valves 18. Blowdown Valves 20

SAMPLE PRODUCT SPECIFICATIONS

flow measurement solutions RIM10 series rotor insertion flowmeters

Flow Meter Terminal Boxes

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Differential Pressure Gauge

Pressure Reducing Valve Type 2114/2415

PT-516 Pumping Trap Installation and Maintenance

Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES

So how does a turbocharger get more air into the engine? Let us first look at the schematic below:

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Valve Selection. 1. Function and service considerations

Biogas safety control equipment

walton TEMPERATURE CONTROL SYSTEMS Pneumatically Operated (Rotary)

Lecture 3.3. Velocity, motion, force and pressure sensors

FUNDAMENTALS OF PRESSURE & TEMPERATURE MEASUREMENT. Brian Cleary. Emerson Process Management

EMaSM. Principles Of Sensors & transducers

Article on Sheath materials, Thermowells, Fittings, and Terminations

Dosage Pumps - Installation Guide

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Please note this is a condensed catalog. For a complete version, contact Velan directly.

SECTION METERS AND GAUGES

Chapter 11. Control System Instrumentation

MONOVAR is the energy dissipating valve.

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Displacement Sensor. Model 8739, 8740, 8741

SECTION HVAC WATER PIPING ACCESSORIES

Pressure Gauges. General purpose utility gauges ASME grade B 3-2-3% - Quality & Economy

PUMP TYPE SERIES SLM AVP ACCORDING TO API 685

Load cells for a Portable Structure

Applied Fluid Mechanics

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Miniature Combination Pressure/Temperature Sensors with Redundant Capability. Dr. A.D. Kurtz, A. Kane, S. Goodman, Leo Geras

2.6. Air Flow Control Valve Type PRD

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operation & Maintenance Instructions

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

Turbo Tech 101 ( Basic )

VELOCITY CONTROL TECHNOLOGY DESUPERHEATERS

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

MEASURING INSTRUMENTS. Basic Electrical Engineering (REE-101) 1

VAD Variable Area Desuperheaters

548 hydraulic separator

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

Differential Pressure Transmitter

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

CB50X & CB50X-DL load cells Influence factors in weighbridge application

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

TEMPERATURE SENSOR ASSEMBLIES (PROBE)

3. The working pressure shall be 145 psi and tested to 230 psi.

PRESSURE REDUCING VALVES

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Measurement of thermocouple emf using potentiometer & milivoltmeter. Milivoltmeter consists of a PMMC type meter. The coil gets magnetised when the


NECO Pumping Systems

Mechanical pressure gauges

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

LIQUID MEASUREMENT STATION DESIGN Class No

UNIT 8 OTHER SENSORS

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

LIQUEFIED GAS PUMP INSTALLATION

EXPERIMENT 5 (a) PRESSURE, PROXIMITY AND MAGNETIC FIELD SENSORS

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

GVK Series (Steam-to-Steam) Clean Steam Generators

Module 7: Cooling System Components

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

Practical No: Aim: List out the tools required for Instrumentation Workshop and draw the diagram of any two tools

PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

Steam Jet Syphons. Index. Bulletin 2A

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Temperature Regulators

Self-operated Temperature Regulators Temperature Regulator Type 1u

Transcription:

Gauges, Sight Glasses and Vacuum Breakers

Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure reducing valve - To monitor the integrity of the steam supply. Downstream of a pressure reducing valve - To set and monitor the downstream pressure. Variations in the downstream pressure can lead to reduced plant productivity and product quality. Variations in the downstream pressure may also indicate problems with the pressure reducing valve. On blowdown vessels - A pressure gauge is used to check the vessel pressure during blowdown. This improves safety, since a higher pressure than normal would give an early indication of pipework blockage. Flash steam vessels - To monitor the flash steam pressure. The Bourdon tube pressure gauge is the most commonly used type in steam systems. It consists of a coiled or C shaped tube that is sealed at one end, and open at the other. The open end of the Bourdon tube is exposed to the process fluid, allowing it to flow into the tube. Any increase in pressure causes elastic distortion of the tube, causing it to unwind. The resulting displacement of the closed end of the tube is translated by a series of gears to an angular displacement of the pointer. The pointer position is therefore proportional to the pressure applied at the gauge s pressure connector. Typically, the maximum deflection of the Bourdon tube corresponds to a pointer angular displacement of 270. The tube can be constructed out of a number of different materials, depending on the application; generally, brass or bronze is used for higher pressures, whereas stainless steel is used for lower pressures. (a) Fig. 12.6.1 C -shaped (a) and coiled (b) Bourdon tubes Bourdon tube pressure gauges often have the option of being liquid filled. The area surrounding the Bourdon tube is filled with a transparent liquid, normally glycerine. This protects the internal mechanisms against damage from severe vibration and to keep out ambient corrosives and condensation. This also damps the movement of the pointer making the gauge less susceptible to small transient pressure fluctuations. As the Bourdon tube may be damaged by high temperatures, it is common practice on steam systems to install the gauge at the end of a syphon tube. The syphon tube is filled with water which transmits the pressure of the working fluid to the Bourdon tube, enabling the gauge to be located some distance from the actual point where the pressure is being measured. The two most common forms of syphon tube are the U and ring types. The ring tube is used on horizontal pipelines where there is sufficient space above the pipe, and the U type is used when mounting the gauge on a vertical pipeline, or on horizontal pipelines where there is not sufficient space for a ring type siphon. (b)

Vertical pipe Horizontal pipe (a) (b) Fig. 12.6.2 U (a) and ring type (b) syphon tubes The Bourdon type pressure gauge is not suitable for use on corrosive liquids or fluids containing suspended solids alone, as these solids may damage the internal elements of the gauge. In such cases, it is necessary to keep the process fluid separate from the Bourdon tube. This is done by mounting a flexible diaphragm on the inlet to the gauge. The pressure element of the gauge and the space behind the diaphragm form a completely sealed system, which is evacuated and then filled with a suitable filling fluid; in the case of steam this is typically a type of oil. The system pressure causes the diaphragm to deflect, and the pressure is transmitted through the filling fluid to the Bourdon tube. Diaphragm seals should also be used on clean steam applications where no dead space is allowed. In addition to the Bourdon tube pressure gauge, several other types of pressure gauge are available which include; Diaphragm type pressure gauges, Piezoresistive pressure gauges and Temperature gauges. Diaphragm type pressure gauges A metal diaphragm is clamped between two flanges, and is exposed to the pressure medium on one side. Pressure exerted by the fluid causes elastic deflection of the diaphragm. The amount of deflection is proportional to the pressure applied on the diaphragm and it causes the linear displacement of a linkage rod attached to the internal side of the diaphragm. The movement of the linkage rod is in turn translated to angular movement of the gauge s pointer by a series of gears. Thus, the pointer movement is proportional to the pressure exerted on the diaphragm. The diaphragm also serves to isolate the fluid from the internals of the gauge; therefore, diaphragm type pressure gauges are suitable for use on most fluid types. Dial Pointer mechanism Pointer Diaphragm capsule Fig. 12.6.3 Schematic diagram of a diaphragm pressure gauge

Piezoresistive pressure gauges These pressure gauges consist of a diaphragm made from a ceramic substrate; piezoresistive type strain gauges are bonded to the diaphragm and together with the necessary circuitry, they are integrated on a silicon chip. The diaphragm deflects with changes in pressure, causing a change in the balance of the strain gauge bridge. This is converted by the integrated circuit module to an electronic signal that is proportional to the pressure. The output signal can be fed into a local digital display or further converted into a 4-20 ma signal output for remote transmission. These gauges are very sensitive and are used where precise measurement of pressure is required. Since they produce an electrical output signal, it is possible to incorporate them into building management systems. Temperature gauges Although there are a multitude of different temperature gauges available, five major types are likely to be encountered in steam systems, namely, the bimetallic type, the filled system type, thermistors, thermocouples and resistance temperature devices (RTDs). The bimetallic type temperature gauge - Consists of a coiled bimetallic element. The gauge is based on the principle of the bimetallic strip, which consists of two metal strips, made from different materials, bonded to each other. The two materials are selected so that they have different thermal coefficients of expansion. The two metals expand by different amounts when heated, and since they cannot move relative to each other, the bimetallic strip bends. Higher coefficient of thermal expansion Fig. 12.6.4 Principle of a bimetallic strip When the temperature of the coiled element rises, it tends to unwind. The degree to which this occurs is indicative of the temperature. A pointer is connected to the coil by a series of linkages, in a similar way to that in the bourdon tube. Bimetallic gauges tend to be inexpensive, robust and easy to install. They are used where a simple, quick visual indication of temperature is required. Fig. 12.6.5 A bimetallic temperature gauge

Other methods of temperature measurement - are dealt with in Module 6.7, Controllers and Sensors. These types of temperature sensors are used when a higher level of accuracy is required in measuring temperature, or when this function is to be automated or incorporated into a building management system. It is common to place a temperature-measuring probe into a pocket when installed into an item of plant. This enables the sensor to be removed from pipework or equipment without disturbing the integrity of the system. A heat conducting paste is used in the pocket to provide good heat transfer qualities. One area of concern when installing a temperature-measuring device is ensuring that it takes a representative reading. It is common, particularly in liquid containing vessels, for there to be some kind of thermal layering of the fluid, and measuring the temperature of the vessels at different levels may produce different results. Common applications of temperature-measuring devices include boiler feedtanks, measuring product temperatures and measuring the steam temperature after de-superheating. Sight glasses A sight glass, or sight flow indicator, provides a method of observing fluid flow in a pipeline. It has two main functions: Indication - Sight glasses are used to indicate if fluid is flowing correctly. They are used to detect blocked valves, strainers, steam traps and other pipeline equipment, as well as to detect if a steam trap is leaking steam. Inspection - Sight glasses can be used to observe the colour of a product at different stages of the production process. When sight glasses are used to indicate the correct functioning of blast discharge type steam traps, they should be positioned at least 1 m downstream from the trap. For other traps, the sight glass should be positioned immediately after the trap. Sight glasses do not provide an exact method of monitoring the functioning of steam traps. In practice, a thorough knowledge of the upstream steam system is required and the diagnosis is often subjective, depending on the experience of the observer. For example, depending on the condensate flowrate, pressure and trap discharge pattern, it can be difficult to differentiate if the steam trap is leaking steam or if flash steam is being generated after the steam trap. Sight glasses have generally been replaced by electrical devices such as conductivity sensors, which detect flooding upstream of the steam trap, or leaking traps. These devices do not require steam trap expertise and produce a consistently accurate result. Sight glasses The sight glass has a smooth concentric reduction in the inlet connection, which promotes turbulence in the sight glass when fluid is flowing through it. The turbulent flow inside the sight glass permits any fluid to be detected. Sight glasses are available with single, double or multi-viewing windows. (a) (b) (c) Fig. 12.6.6 Single (a), double (b) and multiple (c) window sight glasses Some sight glasses may be fitted with a light source, these are useful when the sight glass is fitted in an area of low ambient lighting, or where a single window sight glass has to be used, such as in tanks.

Sight check The sight check (see Figure 12.6.7) is a combination of a sight glass and a check valve. A ball in the top of the flow tube is lifted off its seat by the fluid as it flows through the cylindrical window to the outlet connection. When there is reverse flow, the ball is forced back onto its seat on the inlet. The ball movement makes the flow easy to see, as well as providing shut-off on reverse flow. As with sight glasses, the sight check is used to observe the discharge of steam traps. In the sight check, the position of the ball check indicates whether condensate is flowing. Where condensate rises after the trap, the sight check eliminates the need for a separate check valve, thus simplifying installation. The sight check is particularly useful for commissioning steam traps fitted with a steam lock release (SLR). Ball Glass Flow Vacuum breakers Fig. 12.6.7 A sight check Vacuum breakers protect plant and process equipment against vacuum conditions, typically associated with cooling. Air allowed in under vacuum conditions Fig. 12.6.8 Vacuum breaker and a cut section of a vacuum breaker

The vacuum breaker consists of a spherical stainless steel ball that rests on its seat during normal operating conditions. At the point of vacuum, the valve is lifted off its seat and air is drawn into the system. Normal operation Cooling At point of vacuum Air inlet Valve closed Valve open Steam connection Fig.12.6.9 Operation of a vacuum breaker In some cases, the valve may be spring loaded, which means that the vacuum is only broken when there is a further pressure decrease. This helps to ensure that the shut-off at near vacuum conditions remains bubble tight. One of the most common applications of a vacuum breaker is on process equipment such as jacketed pans and heat exchangers. When these items are turned off, they still contain a certain amount of steam. The steam condenses as the vessel cools down, and since condensate occupies a much smaller volume than the steam, vacuum conditions are generated. The vacuum can damage the plant and it is therefore necessary to install a vacuum breaker on the steam inlet to such equipment or onto the plant body. The same situation can occur on steam mains and boilers. A common application of vacuum breakers is on temperature-controlled heat exchangers that are likely to suffer from stall (see Block 13). On smaller heat exchangers draining to atmosphere, the stall condition can be avoided by installing a vacuum breaker on the steam inlet to the heat exchanger. When the vacuum is reached in the steam space, the vacuum breaker opens to allow condensate to drain down to the steam trap. Temperature control system Steam in Vacuum breaker Secondary flow Shell and tube heat exchanger Static head Secondary return Condensate out to return Fig. 12.6.10 The use of a vacuum breaker to prevent stall In general, it is not desirable to introduce air into the steam space, since it acts as a barrier to heat transfer and reduces the effective steam temperature (refer to Module 2.4). This becomes a problem on larger heat exchangers, where it is not advisable to use a vacuum breaker to overcome stall. Furthermore, if the condensate is lifted after the steam trap, for example, into a raised condensate return main, the vacuum breaker cannot assist drainage. In both these cases, it is necessary to use an active method of condensate removal such as a pump-trap (refer to Module 13.8).