Passive Speed Sensors

Similar documents
Proximity Transmitters, and Seismic Vibration Transmitters

Proximity Transmitters, and Seismic Vibration Transmitters

SKINNER Intrinsically Safe Series Four-Way

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Solenoid Valves Type 3963

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Seismic Sensor Accessories SA, SV & ST 6000 Series

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

PPT 802, Proximity Probe Transducer System

PXT-K Series. Pressure Transmitters Section 05

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Control Without Compromise. Suitable for use in hot, cold, wet, dirty, abusive, corrosive, and explosive environments

Model 3400 Intrinsically Safe Load Cell

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

Certificate of Compliance

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

GO Switch Leverless Limit Switches 02 Reliable, Durable Position Sensing GO Switch leverless limit switches provide reliable, durable position sensing

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Operating pressure (bar) kv factor (m 3 /h) *3)

APPROVALS:

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Fisher i2p 100 Electro Pneumatic Transducer

G 1/4 A DIN 3852 (bar version) ±0.5 %FS max

A LOOK INSIDE MODEL 7 TECHNOLOGY IN ACTION 70 Series LEVERLESS LIMIT SWITCH GO Switch 70 Series end sensing switches use three permanent magnets and p

Data sheet... W-Series WPE 4

V200 Series Positioners

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

97105 Inline. Ordering information. Technical data. Accessories See page 5

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Redundant Control System

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Proximity Transducers, Seismic Sensors and Accessories

Belt Scales Speed sensors

GO gets it. The all in one proximity sensor and limit switch.

V200 Series Positioners

Belt Scales Speed sensors

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Certificate of Compliance

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Integrated Control modules

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Rosemount 3095FT MultiVariable Flow Data Logger

Direct-acting 2/2-way plunger valve

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

HERION SERIES Indirect solenoid actuated soft seal

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

WDB810V3AI Continuous Temperature Monitoring NTC 1/4 BSP 20. WDB819V3AI Continuous Temperature Monitoring PT100 1/4 BSP 20

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Heating Cable. Description

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Fisher 3660 and 3661 Positioners

Series Level-Trol Electronic Liquid Level Transmitters

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Easier! Faster! Safer!

V200 Series Positioners

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Continuous level measuring system NB 3000 Selection list. Overview

Sensor boxes SRBE Key features and product range overview

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Studded Power Feed Thru Terminal Blocks

Certificate of Compliance

Overview. Specifications. Applications

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Point level measurement Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Instruction Manual December milltronics RBSS

VK-P SERIES TSI TRANSDUCER MODEL VK-263P TRANSDUCER INSTRUCTION MANUAL

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Ar-Mite TM Low Flow Armored Flowmeter

Integrated Control modules

Bulletin 871P Can Sensors

BETA SWITCHES FOR HAZARDOUS AREA

97100 NAMUR. Technical data

Kämmer Actuators Series 4 Pneumatic and Electropneumatic

Continuous level measuring system NB 3000 Selection list

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

G2 Industrial Grade Meters

Our policy is one of continued research and development. We therefore reserve the right

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Clearwater Tech - Phone: Fax: Web: -

4 Redundant Control System

Transcription:

5/8 18 FAMILY General Purpose 70085-1010-001 1.125 (28.57) 70085-1010-003 2.625 (66.67) 70085-1010-018 3.625 (92.07) 70085-1010-118 5.000 (127.00) (Select cable from group A, see index) Output Voltage (Standard): 40 V (P-P) Output Voltage (Guarantee Point): 3.4 V (P-P) DC Resistance: 130 ohms max. Typical Inductance: 33 mh ref. Output Polarity: Pin B positive Operating Temperature: -55 to +107 C Net Weight: 5 oz. max. High Sensitivity 70085-1010-002 1.125 (28.57) 70085-1010-175 2.625 (66.67) 70085-1010-026 3.625 (92.07) 70085-1010-408 5.000 (127.00) (Select cable from group A, see index) Output Voltage (Standard): 150 V (P-P) Output Voltage (Guarantee Point):12.9 V (P-P) DC Resistance: 1500 ohms max. Typical Inductance: 360 mh ref. Output Polarity: Pin B positive Operating Temperature: -55 to +107 C Net Weight: 5 oz. max. 8

5/8 18 FAMILY Power Output 70085-1010-028 1.437 (36.50) (Select cable from group A, see index) Output Voltage (Standard): 75 V (P-P) Output Voltage (Guarantee Point): 21.5 V (P-P) DC Resistance: 210 ohms max. Typical Inductance: 50 to 95 mh ref. Output Polarity: Pin "B" positive Operating Temperature: -73 to +107 C Net Weight: 2.2 oz. max. Based on 8 D.P. Gear Conduit Fitting General Purpose 70085-1010-004 1.125 (28.57) 70085-1010-469 2.750 (69.85) Output Voltage (Standard): 43 V (P-P) Output Voltage (Guarantee Point): 4.3 V (P-P) DC Resistance: 130 ohms max. Typical Inductance: 32-46 mh ref. Output Polarity: Red lead positive Operating Temperature: -73 to +107 C Lead length: 10 ft (3.05 m) Net Weight: 16 oz. max. 9

5/8 18 FAMILY Full Thread Power Output Ordering Part # 70085-1010-131 70085-1010-214 Thread Length (A) 1.80 (45.72) 3.06 (77.72) Based on 8 D.P. Gear Output Voltage (Standard): 120 V (P-P) Output Voltage (Guarantee Point):15.1 V (P-P) DC Resistance: 250 ohms max. Typical Inductance: 40-60 mh ref. Operating Temperature: -55 to +107 C Cable Length: 10 ft (3.05 m) Net Weight: 5 oz. max. Full Thread General Purpose Ordering Part # 70085-1010-078 70085-1010-137 Thread Length (A) 1.80 (45.72) 3.06 (77.72) Output Voltage (Standard): 40 V (P-P) Output Voltage (Guarantee Point): 3.4 V (P-P) DC Resistance: 130 ohms max. Typical Inductance: 33 mh ref. Output Polarity: white lead positive Operating Temperature: -55 to +107 C Lead Length: -078, 12 in (30.5 cm) -137, 24 in (60.9 cm) Net Weight: 3 oz. max. 10

5/8 18 FAMILY Full Thread High Sensitivity Ordering Part # 70085-8080-003 70085-1010-220 Thread Length (A) 1.80 (45.72) 3.06 (77.72) Output Voltage (Standard): 150 V (P-P) Output Voltage (Guarantee Point): 12.8 V (P-P) DC Resistance: 1430 ohms max. Typical Inductance: 500 mh ref. Operating Temperature: -55 to + 107 C Lead Length: -003, 12 in (30.5 cm) -220, 36 in (91.4 cm) Net Weight: 3 oz. max. Molded High Sensitivity 70084-1713-111 1.125 (28.57) (Select cable from group A, see index).625 15.88 Output Voltage (Standard): 190 V (P-P) Output Voltage (Guarantee Point): 13.9 V (P-P) DC Resistance: 1200 ohms max. Typical Inductance: 400 mh ref. Output Polarity: Pin B positive Operating Temperature: -40 to +150 C Net Weight: 2 oz. max. 11

5/8 18 FAMILY Molded 70085-1010-421 2.475 (62.87) 70085-1010-425 3.000 (76.20)* M16 x 1.5 Thd. 70085-1010-424 4.493 (114.12) (Select cable from group A, see index) ** Output Voltage (Standard): 63 V (P-P) Output Voltage (Guarantee Point): 4.9V (P-P) DC Resistance: 250 ohms max. Typical Inductance: 63 mh ref. Output Polarity: Pin B positive Operating Temperature: -55 to +107 C Net Weight: 5 oz. max. 12

3/8 24 FAMILY General Purpose 70085-1010-007.812 (20.62) 70085-1010-056 3.625 (92.08) Output Voltage (Standard): 21 V (P-P) Output Voltage (Guarantee Point): 1.6 V (P-P) DC Resistance: 125 ohms max. Typical Inductance: 22 mh ref. Operating Temperature: -55 to +107 C Lead Length: 6 in (15.2 cm) Net Weight: 2 oz. max. High Sensitivity 70085-1010-086.812 (20.62) 70085-1010-355.812 (20.62) Output Voltage (Standard): 55 V (P-P) Output Voltage (Guarantee Point): 4.2V (P-P) DC Resistance: 960 ohms max. Typical Inductance: 125 mh ref. Operating Temperature: -55 to +107 C Lead Length: -086, 18 in (45.7 cm) Cable Length: -355, 40 in (101.6 cm) Net Weight: 2 oz. max. 13

3/8 24 FAMILY General Purpose High Temperature 70085-1010-041.812 (20.62) 70085-1010-428 1.500 (38.10) 70085-1010-458 3.625 (92.08) Output Voltage (Standard): 24 V (P-P) Output Voltage (Guarantee Point): 2.0 V (P-P) DC Resistance: 125 ohms max. Typical Inductance: 21 mh ref. Operating Temperature: -73 to +232 C Lead Length: 40 in (1 m) Net Weight: 2 oz. max. High Sensitivity - High Temperature 70085-1010-174.812 (20.62) Output Voltage (Standard): 55 V (P-P) Output Voltage (Guarantee Point): 3.6V (P-P) DC Resistance: 705 ohms max. Typical Inductance: 150 mh ref. Operating Temperature: -65 to +220 C Cable Length: 60 in (1.5 m) Net Weight: 2 oz. max. 14

3/8 24 FAMILY Full Thread High Sensitivity 70085-1010-120 1.250 (31.75) 70085-8080-001 1.500 (38.10) Output Voltage (Standard): 55 V (P-P) Output Voltage (Guarantee Point): 4.2 V (P-P) DC Resistance: 960 ohms max. Typical Inductance: 125 mh ref. Operating Temperature: -55 to + 107 C Lead Length: 6 in (15.2cm) Net Weight: 1 oz. max. Smooth Body High Sensitivity Ordering Part # Length (A) 70085-1010-314 1.375 (34.93) 70085-8080-004 2.500 (63.50) Output Voltage (Standard): 55 V (P-P) Output Voltage (Guarantee Point): 4.2 V (P-P) DC Resistance: 960 ohms max. Typical Inductance: 125 mh ref. Operating Temperature: -30 to +85 C Lead Length: -004, 6 in (15.2cm) Cable Length: -314, 10ft (3.05m) Net Weight: 3 oz. max. 15

1/4-40 FAMILY General Purpose - High Temperature (B) 70085-1010-024.687 (17.45).313 (7.95) 70085-1010-472 *.687 (17.45).500 (12.70) 70085-1010-227 1.687 (42.85).313 (7.95) Output Voltage (Standard): 4.7 V (P-P) Output Voltage (Guarantee Point): 0.4 V (P-P) DC Resistance: 125 ohms max. Typical Inductance: 5-12 mh ref. Operating Temperature: -73 to 232 C Lead Length: 8 in (20.3 cm) Cable Length: -472, 60 in (1.5 m) * Net Weight: 2 oz. max. * Egress is a 2-conductor, AWG #26, shielded, Teflon cable, with 3" long shrink tubing over housing and cable for extra protection. Extra locknut provided. 16

10-32 FAMILY High Sensitivity 70085-1010-037.500 (12.70) 70085-1010-299 1.250 (31.75) Output Voltage (Standard): 13 V (P-P) Output Voltage (Guarantee Point):.6 V (P-P) DC Resistance: 190 ohms max. Typical Inductance: 10 mh, ref. Operating Temperature: -55 to +107 C Lead Length: 18 in (45.7 cm) Net Weight: 1 oz. max. General Purpose High Temperature 70085-1010-182.500 (12.70) 70085-1010-289 1.250 (31.75) Output Voltage (Standard): 6 V (P-P) Output Voltage (Guarantee Point):.3 V (P-P) DC Resistance: 50 ohms max. Typical Inductance: 2 mh, ref. Operating Temperature: -73 to +150 C Lead Length: 18 in (45.7 cm) Net Weight: 1 oz. max. 17

LISTED PRODUCT UL/ATEX/CSA Sensors 70085-1010-081 1.500 (38.10) 70085-1010-411 1.875 (47.63) 70085-1010-329 2.750 (69.85) 70085-1010-330 4.000 (101.60) 70085-1010-412 6.000 (152.40) Rating: UL and CSA listed for hazardous locations. Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups E, F,G. Temp Code T3C. ATEX Group II, Category 3G, Zone 2 Based on 8 D.P. Gear Output Voltage (Standard): 54 V (P-P) Output Voltage (Guarantee Point):13.4 V (P-P) DC Resistance: 240 ohms max. Typical Inductance: 30 mh ref. Operating Temperature: -65 to 100 C Lead Length: 10 ft (3.05 m) Housing Ground: Green/Yellow Tracer Net Weight: 14 oz. max. 70085-1010-413 1.500 (38.10) 70085-1010-005 1.875 (47.63) 70085-1010-327 2.750 (69.85) 70085-1010-328 4.000 (101.60) 70085-1010-414 6.000 (152.40) Rating: UL and CSA listed for hazardous locations. Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups E, F,G. Temp Code T3C. ATEX Group II, Category 3G, Zone 2 18 UL/ATEX/CSA Sensors Based on 8 D.P. Gear Output Voltage (Standard): 54 V (P-P) Output Voltage (Guarantee Point):13.4 V (P-P) DC Resistance: 240 ohms max. Typical Inductance: 30 mh ref. Operating Temperature: -65 to +100 C Lead Length: 10 ft (3.05 m) Housing Ground: Green/Yellow Tracer Net Weight: 14 oz. max.

LISTED PRODUCT FM / ATEX Sensors Thread Size (B) 70085-1010-404 1.500 (38.10) 5/8-18 UNF-2A 70085-1010-544 1.875 (47.63) 5/8-18 UNF-2A 70085-1010-406 2.750 (69.85) 5/8-18 UNF-2A 70085-1010-417 4.000 (101.60) 5/8-18 UNF-2A 70085-1010-420 6.000 (152.40) 5/8-18 UNF-2A 70085-1010-541 1.875 (47.63) 3/4-20 UNEF-2A 70085-1010-542 2.750 (69.85) 3/4-20 UNEF-2A 70085-1010-540 4.000 (101.60) 3/4-20 UNEF-2A 70085-1010-543 6.000 (152.40) 3/4-20 UNEF-2A Rating: FM listed Intrinsically Safe, Class I, Division 1, Groups A, B, C, D; ATEX Group II, Category 3G, Zone 2. THREAD SIZE Output Voltage (Standard): 60V (P-P) Output Voltage (Guarantee Point): 13.4V (P-P) DC Resistance: 210 ohms max. Typical Inductance: 75 mh max. Operating Temperature: -55 to +220 C Cable Length: 15 ft. (4.57m) Net Weight: 16 oz. max. Based on 8 D.P. Gear FM / ATEX Sensors 70085-1010-403 1.500 (38.10) 70085-1010-415 4.000 (101.60) 70085-1010-416 6.000 (152.40) 70085-1010-405 2.750 (69.85) Thread Size (B) 5/8-18 UNF-2A 5/8-18 UNF-2A 5/8-18 UNF-2A 3/4-20 UNEF-2A THREAD SIZE * Rating: FM listed Intrinsically Safe, Class I, Division 1, Groups A, B, C, D; ATEX Group II, Category 3G, Zone 2. Output Voltage (Standard): 90 V (P-P) Output Voltage (Guarantee Point): 9.4 V (P-P) DC Resistance: 750 ohms max. Typical Inductance: 210 mh max. Operating Temperature: -55 to +232 C *Mounting Thread: -0405, 3/4-20 UNEF-2A Cable Length: 15 ft (4.57 m) Net Weight: 16 oz. max. 19

LISTED PRODUCT IEC EX Sensors Thread Size (B) Cable Length (C) Conduit Thread 70085-3030-111 1.500 (38.10) 5/8-18 UNF-2A 3 m 1/2 NPT 70085-3030-112 2.750 (68.85) 5/8-18 UNF-2A 3 m 1/2 NPT 70085-3030-113 4.000 (101.6) 5/8-18 UNF-2A 3 m 1/2 NPT 70085-3030-114 6.000 (152.4) 5/8-18 UNF-2A 3 m 1/2 NPT 70085-3030-211 1.500 (38.10) 5/8-18 UNF-2A 10 m 1/2 NPT 70085-3030-212 2.750 (68.85) 5/8-18 UNF-2A 10 m 1/2 NPT 70085-3030-213 4.000 (101.6) 5/8-18 UNF-2A 10 m 1/2 NPT 70085-3030-214 6.000 (152.4) 5/8-18 UNF-2A 10 m 1/2 NPT 70085-3030-222 2.750 (68.85) 3/4-20 UNEF-2A 10 m 1/2 NPT 70085-3030-235 1.575 (40.00) M16 x 1.5 6g 10 m G 1/2 70085-3030-237 3.937 (100.0) M16 x 1.5 6g 10 m G 1/2 THREAD SIZE Rating: ATEX and IEC Ex Equip Group II, Category 2G, Gas Group IIC, Zone 1 Sensor must be used with MTL 7764ac intrinsic barrier User must install sensor in such a manner as to limit the output voltage to less than 12V Pk-Pk and a total energy of less than 26 microjoules Output Voltage (Standard): 54 V (P-P) Output Voltage (Guarantee Point):13.4 V (P-P) DC Resistance: 240 ohms max. Typical Inductance: 30 mh ref. Operating Temperature: -65 to 100 C Net Weight: 14 oz. max. Based on 8 D.P. Gear Available in a range of inch and metric thread lengths and sizes and cable lengths of 3 or 10 meters. Consult factory for additional details. 20