VE-S_15-32 Pressure Independent Balancing & Control Valves

Similar documents
Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

VE-x Plug & Seat Valve Assemblies

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

ROTARY PRESSURE INDEPENDENT CONTROL VALVE TECHNICAL MANUAL

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

Section 20. HVAC Valves & Products

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

VPI45.. VPI45..Q. Combi valves, PN 25. Building Technologies. VPI45..Q with pressure test points ACVATIX

Terminator PICV. Technical Manual

Features Globe Valve 2-Way & 3-Way Assembly Features:

Combi valves PN 16 with flanged connections

VPI45..Q with pressure test points. Combi valves, PN 25

Pressure Independent Control Valve

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

HERZ-Connect 4 / Compact Connect 4 & Commissioning Centres

2-Way & 3-Way Non Spring Return Characterized Ball Valves

Characterized Port -CP Three-Way Ball Valves

T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)

599 Series Zone Valve Bodies:

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

VPI45..Q with pressure test points. Combi valves, PN 25

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

Direct/Factory Mounting Valve Set

2-position electric actuators with Ball valves VBZ ½...11/4

ZONE CONTROLE / 2-WAY

FCU 6-PORT PICV VALVE SET MODULE BROCHURE

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

P1000 Series Pressure Independent Valves

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

ACVATIX MiniCombiValves (MCV)

Type overview. R B2 en-gb subject to changes 1

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Actuators for small valves

A 601 A B C. 1. How it works

Pressure independent balancing and control valve AB-QM DN

Pressure Independent Control Valve

Zone Valves and Parts (Honeywell)

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

VPA Series and VAP Actuator

ELECTRIC ACTUATORS 400 N

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Fig.306F (DN50-150) Pressure Independent Control Valve (PICV)

---Pressure Independent Control Valve

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Pressure Independent Control Valve

Control valves with pneumatic actuators up to 350 C PN

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

BALANCING VALVES FOR BUILDING

Balancing Valves. Venturi Commissioning Valve (FODRV) & (DRV) Cu x Cu Compression DN10-DN50. BOSS TM 901SC Venturi DRV DN

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

VG6000 Series Forged Brass Valves

G3 (D) 3-way Globe Valve, Bronze Trim

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

FlowCon Energy FIT System

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Pressure Independent Control Series

2-Port and 3-Port Zone Valves PN 16

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

B2 Series Characterized Control Valve, Non-Spring Return Actuator

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

KVC7934, KVC7936. Modulating Actuators without and with Power Failure Reposition For KVC Series Cartridge Valve. Specifications 12.

pressure independent characterized control tm

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST

Pressure independent balancing and control valve

NETSIAN TECHNOLOGY VALVE SCHEDULE

VG9000 Flanged Valves

Harmony Installation, Operation and Maintenance

485 - NC NO/DA DN

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

2-Port and 3-Port Zone Valves, PN16

Combi valves, PN 25. for rooms, zones, ventilation and air-conditioning systems

VPP46.. Combi valves, PN 25 VPP46..Q VPI46.. VPI46..Q ACVATIX. for rooms, zones, ventilation and air-conditioning systems

NV Direct Coupled Globe Valve Actuator

Pressure Independent Control Series

TA-6-way valve. Standard control valves 6-way valve for change-over systems

HERZ-Motorised flow controler

3-Port Seat Valves with Male Thread, PN 16

PCS. HVAC Products. Technical submission. Type of Product

VA-8020 Floating Valve Actuator

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

Damper Actuator Installation

Valve Body Material:Ductile iron QT Caliber:DN50...DN250 Standard of flange connection in accordance with ISO7005-2

Control valves with electric actuators up to 90 C PN

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

2-Port and 3-Port Zone Valves & Actuators, PN16

V5822A/5823A,C/V5832A/V5833A,C

2-port and 3-port ball valves PN 40

NVCB 9000 series Ball Valves with Characterised Disc 2-way Flanged DN 100/DN 125/DN 150

VA-7450 Series. Electric Valve Actuators

Control, Performance and Flexibility

Transcription:

Page 1 of 9 VE-S_15-32 Pressure Independent Balancing & Control Valves (PIBCV) is used in heating and cooling systems in applications with Fan Coil Units, Chilled Beams or other terminal unit applications. They provide modulating control with full authority regardless of any fluctuations in the differential pressure of the system. And combines an externally adjustable automatic balancing valve, a differential pressure control valve and a full authority modulating control valve. Making it simple to achieve 100% control of the water flow in the building, while creating high comfort and energy savings at the same time. An additional benefit is that no balancing is required if further stages are added to the system, or if the dimensioned capacity is changed. Energy saving due to optimal control, lower flow and pump pressure. Maximized ΔT due to faster response and increased system stability. Features: Benefits: The pre-setting function has no impact on the stroke; Full stroke modulation at all times, regardless the pre-set flow. The constant differential pressure across the modulating control component guarantees 100% authority. Design Less time to define the necessary equipment for a hydraulic balanced system (only flow data are required) No need to calculate valve authority. Always one. Flexibility if the system is modified after the initial installation Automatic balancing eliminates overflows, regardless of fluctuating pressure conditions in the system. Thermal actuator On/Off or 0-10V, normally closed. Electro mechanical actuator 0-10V, (Linear or Logarithmic) or 3-point control normally closed. Differential pressure operating range up to 400kPa Installation No further regulating valves required in the distribution pipework when the VC-S valves are installed at terminals. Total number of valves minimized due to the 3-in-1 design Minimized commissioning time due to automatic balancing of the system No minimum straight pipe lengths required before or after the valve. High flows with minimal required differential pressure due to advanced design of the valve Small dimensions due to compact housing Higher pre-setting precision due to step-less analogue scale Operation High comfort for the end-users due to high precision temperature control Longer life due to less movements of the actuator

Page 2 of 9 Part Codes, Design, Function & Manual Operation: Valves VC-S-15-L VC-S-15-H VC-S-20-L VC-S-20-H VC-S-25 VC-S-32 Actuators VC-TA1 VC-TA2 VC-TA3 VC-DA1 VC-DA2 VC-DM-1 24V Thermic On/Off 230V Thermic On/Off 24V Thermic Modulating 24V On/Off, 3-Point 230V On/Off, 3-Point 24V Modulating Design The design of the VC-S range of valves combines high performance with small size and compact construction. The main components of the valve are: Differential pressure control Modulating control component Pre-setting scale (not accessible when the actuator is mounted) a Flow range: Low-High b Stroke: 2,5-4,0-5,0-5,5mm P/T Plugs (Optional) Actuator Function Compact can be flushed and commissioned before the actuator is installed. The pre-setting of the dial is user-friendly requiring only a simple flow vs. pre-setting graph. Once the flow is set, the actuator can be mounted and the valve ready to operate. For lowest energy consumption, check the differential pressure at the index valve to set the pump at minimum speed. Manual operation Electro mechanical actuators The actuator can be operated manually with the help of a 3mm hex key. Note If the operation is performed manually without disconnecting from the power, the supply must be disconnected and then reconnected, whereby the actuator will start the calibration process and correctly adjust itself.

Page 3 of 9 Valves: Product description: xternally adjustable automatic balancing valve with a full authority modulating control valve. FIG 1: The valve can be mounted in either the supply or the return line. Installation of strainers and isolation ball valves are recommended. The temperature in and about the actuator should not be below 0 C. Safety Instructions: The manufacturer is not liable for any damage resulting from use other than in the designated application. Such risk lies entirely with the user. Observance of the mounting instructions is considered as part of the valve designated use. The pipe system shall be properly ventilated to avoid risk of air pockets. Glycolic mixtures up to 50% are applicable (both ethylene and propylene). Sontay can accept no responsibility if another actuator is used instead of the Sontay actuator. Valve housing and flow setting DZR Brass DP controller PPS 40% glass Spring Stainless steel Diaphragm HNBR O-rings EPDM Pressure class PN25 Max. differential pressure 400 kpa Medium temperature range 0 C to 120 C (Not supplied)

Page 4 of 9 Valves (continued): Actuators: Thermo Actuators Characteristics Thermo actuators, normally closed Protection class IP 54 to EN 60529 Frequency 50/60 Hz Control signal 0-10V DC or On/Off Actuating force 100 N Stroke 2.5mm or 4.0 mm Running time 120 s 0-10V/180 s On/Off Ambient operating conditions 0 C to 60 C Cable length: 1.0 m The actuator can be protected against unauthorised access simply by removing the visor, e.g. on the radiator.

Page 5 of 9 Valves: Electric Actuators Supply voltage 24V or 230V Frequency 50/60 Hz Cable length 1,5m Protection class IP 43 acc. EN60529 Ambient conditions Temperature 0 C...50 C Humidity 10-90% RH Nominal force >120N Input impedance > 100 k Ohm (DC 0...10v) Nominal stroke 2,5-5,0-5,5mm (Can be set by dip switches) Modulating 0-10Vdc Raise/Lower 24V Raise/Lower 230V Dipswitch settings (0-10V version only): Dip-Switch 1-2-3 Control range, default 0-10V Dip-Switch 4 Stem action, default RA (reverse acting) Dip-Switch 5 Actuator characterization, default EQ% The actuator stroke can be selected via the jumper

Page 6 of 9 Flow Data: VC-S-15-L: VC-S-15-H & VC-S-20-L:

Page 7 of 9 Flow Data: VC-S-20-H: VC-S-25:

Page 8 of 9 Flow Data: VC-S-25: Technical Specifications: The length of the modulating stroke shall be independent of flow setting. The modulation and flow setting shall be one combined unit with a linear modulating motion and a rotational flow setting motion. The valve characterization shall not be changed at different flow settings. The combined flow setting and modulating control unit shall be pressure independent. The Pressure Independent Control Valve shall contain a combined flow setting, differential pressure control and modulating bonnet assembly. The valve housing shall be hot stamped DZR brass CW602N. The valve shall have a spring made of stainless steel, a Diaphragm made of HNBR and O-rings made of EPDM. The valve housing shall be PN25 rated and suitable for 120 C. The valve shall have an external thread ISO 228 or internal ISO 7/1. The valve shall have a maximum operating differential pressure of 400kPa (4 Bar) The valve shall have an external adjustable analogue step less pre-setting scale from minimum to maximum flow. P/T plugs shall be available as standard. The valve shall have a leakage rate at maximum 0,01% of max rated volumetric flow and comply to EN1349 Class IV.

Page 9 of 9 Setting & Flow: VC-S-15-L: VC-S-15-H & VC-S-20-L: VC-S-20-H: VC-S-25 VC-S-32: Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.