Game changing soft starters

Similar documents
The future of soft start motor control at your fingertips

a revolution in soft start motor control The future of soft start motor control at your fingertips

a revolution in soft start motor control The future of soft start motor control at your fingertips

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds


A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Low cost, internally bypassed non optimizing soft starter

Starts, stops and protects. Emotron TSA Softstarter

Softstarters Softstarters

MCD 500 Operating Instruction. Safety 5 Warnings 5. Feature List 7 Type Code 8. Mechanical Installation 9 Dimensions and Weights 10

CTi Automation - Phone: Fax: Web:

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

MAKING MODERN LIVING POSSIBLE. Operating Instructions. VLT Soft Starter - MCD500

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS. Answers for industry.

Guide to the Application of Soft Starters

An Engineering Guide to. Soft Starters

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

80 KW / 100 KVA POWERED by

640 KW / 800 KVA POWERED by

Panorama. Softstarters The complete range

Benefits. transmission devices (gearboxes, pulleys, gears, conveyers, etc) Soft-Star ters are static star ting switches, designed for the

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Innovation in soft start technology. agility USER MANUAL. MAN-AGY-001. Version 01

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

690+ Series Integrator

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

16 KW / 20 KVA POWERED by

Features and Benefits. Control Features

MCD 200 Series Soft Starters

700 KVA / 550 KW POWERED by

1000 KW / 1250 KVA POWERED by

Softstarters Type PSS. Softstarters. General information

PSE The efficient range Description

Phone: Fax: Web:

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

SIRIUS Soft Starters Introduction

1800 KW / 2250 KVA POWERED by

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

RVS-DX Digital Reduced Voltage Motor Starter

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

A softstarter beyond the ordinary

RVS-AX Instruction Manual

Section 0.0 Warnings... 2 Section 1.0

Battery-Powered Flow Transmitter

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Application Description

Micro Controller based Motor Protection Relay & Motor Management System

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Intelligent Softstarter Controllers

RVS-DN Digital Reduced Voltage Motor Starter

Variable speed drive or soft starter?

45 KW / 55 KVA POWERED by

Pocket Guide VLT Soft Starter the single speed drive

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

Designed for ease of integration with automation systems

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Pocket Guide VLT Soft Starter the single speed drive

SSW07. Soft Starters. Applications. Standard Features

HVAC Products. Introducing the SED2 Variable Frequency Drives

Design Guide. VLT MCD 200 Soft Starter. Phone: Fax: Web: -

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Application example of a motor controlled by MCD100 and protected by a circuit breaker

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Reduced Voltage Starters

SINAMICS GM150 IGCT version

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

For Operation in the Control Cabinet 3RW Soft Starters

Softstarters PSR PSS PST Extreme duty

ROBICON W120 enclosed drive

RVS-DX Instruction Manual

ISA-HD MEDIUM VOLTAGE SOFT STARTERS. Digital medium voltage soft starters

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

Contents. MCD 200 Design Guide. Contents

4491 en / c. D IGISTART et. Reference guide

Cooled incubators (ST), laboratory refrigerators

PCS compact soft starters

MEDIUM VOLTAGE DRIVE STARTER TYPE MV-SVFD-ML1

Reduced Voltage Motor Starters

AUCOM NORTH AMERICA. Complete range of motor starting solutions

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

825-P Modular Protection System for motors Specification Guide

OIL/AIR ACTUATED POWER TAKE OFF

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Variable Speed Drives Controlling Centrifugal Pumps Energy Savings

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

Drives and Motor Sizing Made Easy. ABB Inc. October 23, 2014 Slide 1

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Transcription:

Agile soft starters Low Voltage Soft Starters Game changing soft starters 17 66 A

Fire Mode Agile soft starters Soft Stopping Current is limited during soft stopping and gives greater control against water hammer. External input signal overriding normal controls allowing the motor to continue running in emergency situations. 2 3 1 OLED life event logging with real-time clock 6 language menu 600 V max. operating voltage agility has been developed to exceed the exacting demands of industrial automation motor control clients. agility delivers stable, structured start and stop ramps for smooth, efficient performance. One standard frame size covers all typical applications from 7.5 kw to 45 kw at 500 VAC, 15 60 HP at 600 VAC. i23 smart application pre program suite Optimise agility for your specific application at the touch of a button. Select any of the 23 pre-programmed setup profiles and you are up and running in under 1 minute. 3S Technology Automatic ramp control profiles ensure smooth start and stop performance, delivering stable acceleration and deceleration in all operating conditions. 1 2 3 OLED display Full text messages enabling fast programming and rapid fault finding with no codes and real-time value monitoring. Local display of recent logged events. USB for field firmware upgrades and downloading of the event logging data. Modbus RTU communications as standard. No need for optional communication cards.

Frequent Number of Starts Optional cooling fan for frequent duty applications with up to 40 starts per hour. Optional Remote Display Keypad Plug in remote mounting unit keypad mimics the agility display and keypad function. IP65/NEMA Class 4X Optional Power Supply Unit Module Unique to agility this module enables control voltage options in one standard product unit, no need to purchase separate soft starters for different control voltages. Full I²t motor overload protection with thermal memory feature Lower costs, higher performance Motor Overload Protection Life Event Logging Loss Reduction Control Circuit Protecting the motor and soft starter in the event of an overload situation at full I²t motor overload with intelligent thermal memory retention feature. Continually monitoring overloads to ascertain the reduction in overload levels even when agility is in the off state. This is combined with protection and diagnostics giving the operator peace of mind during the motor running phase. agility life event logging is a unique feature that records the last 1600 events to enable fast accurate fault analysis and their resolution. Recording multiple activities including start, stop, top of ramp, faults, application parameters (time, overload level, currents, frequency) and the device information. The data is collated in StarterView programme and provides the operator with the advantage to undertake a detailed analysis of performance and equipment conditioning in an active predictive and preventative maintenance strategy to avoid unwanted breakdowns and any costly lost production time. An integral bypass is initiated at the top of ramp and reduces losses in the soft starter. Start Delay Feature Intentional start delay allowing pump actuators to engage before start. A standard 24 VDC control voltage supply with an optional power module which adapts the digital input voltage to accept a 110 230 VAC signal. Lowers Panel Production Costs One common unit frame size across the voltage range of 200 600 VAC facilitating efficient panel layout and interconnections to reduce material and panel production time.

i23 Optimised application setup A suite of pre programmed application complete setup profiles facilitate a quick and comprehensive commission process to give freedom and independence to engineers. Typical agility setup takes less than 1 minute whereas a comparable competitive product commission could be 60 to 120 minutes for only a partial setup. Access to an advanced setup menu is provided as standard for special application requirements. Mill Fan High Inertia Mixer Agitator Fan Low Inertia Moulding Machine Grinder Press Flywheel Crusher Specification Operational Voltage Rated Frequency 200 600 VAC 50 60 Hz ± 5 Hz Index Rating Trip Class 10: 3.5-17: 90-5 (Trip Class 20 & 30) Starts per Hour Internally Bypassed Screen Control Supply Inputs Outputs Overload Communications Full Logging functionality for use with StarterView Standard 5 starts/stops per hour With Optional Fan 40 starts/stops per hour Yes OLED Standard 24 VDC With Optional Power Supply 110 to 230 VAC 2 Digital Inputs, 1 Programmable Standard 24 VDC With Optional Power Supply 110 to 230 VAC 2 Digital Outputs, 1 Programmable Full I 2 t Motor Overload Modbus RTU Yes IP/NEMA rating IP20/NEMA Class 1 *with finger guard fitted Ambient Temperature Standards Languages Warranty Dimensions -20 C to 40 C without de-rating 60 C with de-rating CE, UL, RCM English, French, German, Spanish, Portuguese, Italian 2 Years Submersible Positive Displacement Jack SawBand AGY-101 to AGY-113 SawCircular Screen Vibrating Shredder Wood Chipper Weight = 1.97 kg (4.34 lbs)

Model Selection Trip Class 10 Trip Class 20 Trip Class 30 For standard operating conditions of 40 C and 1000 m above sea level. See manual for de-rating and other conditions. Rated Starting Capability Typical Applications 3 Motor Current 23 secs 3.5 Motor Current 17 secs Agitator Rotary Vane Scroll Bow Thruster Zero Pitch Fan Low Inertia or <85A Feeder Screw Lathe Machines Mixer Moulding Machine Plastic and Textile Machines Submersible - Centrifugal Submersible - Rotodynamic Saw Band Transformers Voltage Regulators 4 Motor Current 19 secs 4 Motor Current 29 secs Centrifugal Reciprocating Rotary Screw Ball Mill Bow Thruster Grinder Hammer Mill Mills Flour etc. Mixer Pelletizers Press, Flywheel Positive Displacement Reciprocating Rotary Jack Rolling Mill Roots Blower Saw Circular Screen Vibrating Tumblers Crusher* Shredder Wood Chipper Fan* High Inertia or > 85 A * start time > 30 secs Motor Rating I e A kw HP FLA 230 V 400 V 500 V A 200 V 208 V 220 240 V 440 480 V 550 600 V Select Model Select Model Select Model 17 4 7.5 7.5 17 3 5 5 10 15 AGY-10 1 AGY-103 AGY-105 22 5.5 11 11 22 5 5 7.5 15 20 AGY-103 AGY-105 AGY-107 29 7.5 15 15 27 7.5 7.5 7.5 20 25 AGY-105 AGY-107 AGY-109 35 7.5 18.5 22 34 10 10 10 25 30 AGY-107 AGY-109 AGY-1 1 1 41 11 22 22 41 10 10 10 30 40 AGY-109 AGY-1 1 1 AGY-1 1 3 55 15 30 37 52 15 15 15 40 50 AGY-1 1 1 AGY-1 1 3 66 18.5 37 45 65 20 20 20 50 60 AGY-1 1 3 Product Options AGY-020 AGY-010 AGY-030 External 110V-230V Power Supply Module Remote Display Keypad External Cooling Fan Product Spares PLS-AGY-008 Single IP20 Finger Guard, Frame Size 1 For more information on agility contact your local distributor + 44 (0)1752 894554 www.fairford.com

Agile soft starters For more information on agility contact your local distributor + 44 (0)1752 894554 www.fairford.com Fairford Electronics reserves the right to change or update, without notice, any technical information contained in this brochure. Fairford Electronics also reserves the right, without notice, to change the design or construction of the product and to discontinue. BRO-AGY-001-V02