Constant Voltage/Constant Current Test System

Similar documents
3000 Series Operation Manual

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

EPS/ELA-Series User Manual EPS/ELA 250W

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

True RMS Autoranging Multimeter

DEEP SEA ELECTRONICS PLC

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Autoranging Multimeter

DC-Motor Controller. User Manual

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Flight Systems. Replacement for KASSEC DESCRIPTION

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

DEEP SEA ELECTRONICS PLC

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Product Specification QSL RF Connectors

HT Dielectric Withstand Tester Volts AC Output Volts DC Output COMPLIANCE WESTUSA. Instruction Manual

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Autoranging Industrial Multimeter

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

IOTA ONE OPERATING MANUAL AND SETUP INSTRUCTIONS IOTA ONE. Please Read this Instruction Manual COMPLETELY Before Operating the System IOTA ONE

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Harris IRT Enterprises Digital Resistance Tester Model XP

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MODEL NUMBER: APS2424

Mini Multimeter with Non-Contact Voltage Detector (NCV)

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

MODEL NUMBER: APS2448UL

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

P0030, P0036, P0050, P0053, P0054, P0056, P0059, P0060, P0135, P0141, P0155, or P0161

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Induction Power Supplies

MODEL NUMBER: APS3636VR

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description

Analog Input Terminal

Jun06 Rev D

5001TCP SPEED CONTROLLER

DC REGULATED POWER SUPPLY

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

To ensure proper installation, digital pictures with contact information to before startup.

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

Programmable Comparator Options for the isppac-powr1220at8

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

ELECTRICAL SYSTEM RP-7

Selectable Impedance Adapter

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL

Installation and Operations Manual

Powerful Solutions DHP - Introduction

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

Temperature Controllers

OPERATING INSTRUCTIONS

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

APPLICATION NOTES VALVE CHECKER M

MODEL NUMBER: APS750. Highlights. Package Includes. Description

PRODUCT SERIES: DPG-2100

UNIVERSAL CALIBRATOR M

PowerOhm Installation Manual for BM R Series Braking Modules

KD LV Motor Protection Relay

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Continental Hydraulics Installation Manual CEM-AA-A

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Modulating Furnace Information. Warning on Meter Setting - Read First!

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

ESD5500E Series Speed Control Unit

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

RIGrunner 4007U

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Model ½ Digit Multimeter

EDG5500 Electronic Digital Governor With Quikset Display

5001TCP SPEED CONTROLLER

MODEL NUMBER: APS2012

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Combined Ventilation Controller RVWS-T-224HA

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

Division Systems TM Baggage Scale System. Product Specifications

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

MEZALOK* Stacking Connector System

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

MX431 Generator Automatic Voltage Regulator Operation Manual

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

Transcription:

Description Constant Voltage/Constant Current Test System The Constant Voltage/Current Test System may be used for constant voltage or constant current pulse testing of automotive and aerospace igniters, LEDs or other devices that require functional validation. Standardized testing methods, such as Bruceton, may be used to determine all-fire and no-fire conditions. This instrument will provide a stable source of DC voltage or current for a fixed pulse width. The user may control the following test parameters: 1. Output voltage (0.01 to 16.00 volts DC) or current (0.001 to 5.000 amps) 2. Output pulse duration (.0001 to 0.9999 seconds) 3. Safe, Arm and Firing conditions In addition to these user-defined parameters, the instrument has an input for an external safety interlock circuit with a front panel status indicator. A 4-digit LED panel meter accurately indicates the firing voltage or current and a separate 4-digit LED panel meter indicates the selected time duration. Preparation for use Before using the Constant Current/Voltage instrument you must supply power and connect the interlock safety circuits to the rear panel inputs. Please complete the following: Connect a switch that is actuated by test chamber door to the rear panel inputs marked Interlock input. The switch must be closed when the door is closed to enable the internal circuitry. The total wiring and switch resistance must be less than 10 ohms. Determine the local AC voltage, either 115VAC or 230VAC. View the voltage setting in the small window of the power input module. If necessary, remove the AC cord to gain access to the voltage selector drum. Remove the selector drum from the AC inlet module. Select the appropriate AC voltage to correspond with your local power. Reinsert the selector drum and confirm that the proper selection of voltage shows in the window. Verify that the switch within the AC input module on the rear panel is set to O. Plug the modular AC cord to the proper source of 115VAC or 230VAC and into the instrument. Startup To use the instrument please follow the following sequence: Verify that the rear panel power on/off switch is in the off position. Open the test chamber door and examine the test fixture. Be certain that all parts have been removed before proceeding or applying power. Connect the test chamber interlock contacts to the rear panel input marked interlocks. Connect the front panel banana jacks to the test chamber fixture that will hold parts to be tested. The red banana jack is the positive output, black is negative. Press the switch position marked 1 on the on the rear panel AC inlet module. The LED voltage and time meters on the front panel should illuminate. When the interlock contacts are closed the front panel interlock LED should illuminate. Select either the constant voltage mode or the constant current mode with the toggle switch in the middle of the front of the instrument. Adjust the pulse time and select the voltage (or current).

Using the Constant Voltage Instrument; Controls and Indicators Figure 1: Constant Voltage/Current Front Panel The controls of the Constant Voltage/Current equipment are designed for ease of use and simplicity. The rear panel Interlock inputs must be must be connected to the test chamber door safety switch before the test system may be used. The interlock connections ensure that safe conditions exist for operation of the test set and for the operator. Verify the proper operation of the interlock contacts by opening and closing the door of the test chamber. The green LED on the instrument front marked interlock should illuminate when the door is closed. Either constant voltage or constant current mode may be selected by changing the front panel toggle switch. The LED associated with current or voltage will light to reflect the selected mode. The voltage (or current) may be adjusted with the knob to the left of the digital meter marked Voltage/Current when the instrument is in the Safe mode. By default the control is in the fine adjustment mode. For coarse adjustments push in the knob while turning. The displayed voltage or current will be placed onto the part under test when the output is active. The pulse time may be adjusted with the knob to the right of the digital meter marked Time when the instrument is in the Safe mode. By default the control is in the fine adjustment mode. For coarse adjustments push in the knob while turning. The displayed time is the time, in milliseconds, that the output will be active during a test, nominally from 000.1ms to 999.9ms. The Arm mode will only become active when the interlock is maintained and the Arm button is pressed. The Arm button LED on the front panel is illuminated when in the Arm mode. Pressing the Safe button when the test system is Armed will return the instrument to the Safe condition. If the interlocks are broken the instrument will also return to the Safe condition. Pressing the Fire button when the test system is in the Arm mode enables the firing circuits and will output the selected voltage or current for the selected time on the output terminals. The Fire button must be pressed within 60 seconds after the test system is Armed or the instrument will revert to the Safe condition.

Rear panel connections Interlock Switch Inputs Figure 2: Constant Voltage Rear Panel AC Input Module Testing parts with the Constant Voltage Instrument 1. DO NOT turn power to the Constant Voltage/Current system on or off with a part loaded in the test chamber. Examine the AC input module to verify the correct line voltage before use and change to the correct voltage if necessary. Inspect the test chamber and remove all parts before turning on power to the Constant Voltage/Current system. 2. Turn on power to the instrument with the rear panel switch on the AC input module. 3. Verify that the test system is in the Safe mode and load a part to be tested into the test chamber. Close the test chamber door. The front panel Interlock LED should illuminate when the test chamber door is closed. 4. With a part to be tested loaded in the test chamber and the test chamber door closed you may now test the part. 5. Select voltage or current and adjust the voltage/current display to the desired level. 6. Adjust the time display for the desired test time. 7. Inspect the test chamber area for safe firing conditions. 8. Press the Arm pushbutton. The Arm LED should illuminate. Note that the Fire button must be pressed within 60 seconds of Arming or it will revert to the Safe mode. 9. Press the Fire pushbutton. The output terminals will become active with the selected voltage or current for the selected time as the part is tested. The circuitry is automatically disconnected at the end of the test and the equipment is placed into the Safe mode. 10. Remove the tested part from the chamber.

Practical Considerations The constant current/voltage equipment is designed as a general purpose instrument. This means that there are limitations on the ability to accurately deliver voltage or current to a load. For example, if your load is five ohms you will not be able to test at the full five amp capacity of the instrument due to the limited compliance voltage (about 20VDC). Some facilities use remote or larger test chambers with extended wiring. This wiring will add resistance to the part under test and must be allowed for when planning. If your test wiring is one ohm and you wish to test at the full 5 amp capacity of the instrument your part must not exceed three ohms, including contact resistance. The resistance of some igniters will vary during a test due to heating effects. When testing near the limits of the equipment, and when the part has a positive temperature coefficient, this must be taken into account. A typical automotive part may start at ambient temperature near 2.00 ohms and increase to 2.100, or higher, at the end of the test pulse. This would not pose a problem, however a 3.900 ohm part tested at 5 amps may increase in resistance to the point that the compliance voltage limits are exceeded, especially if the wiring resistance is significant. Sample Waveforms Equipment used: Agilent MSO-X 4024A, Tektronix A622 AC/DC current probe. Figure 3: Voltage mode; 100 millisecond, 10 volt pulse into 2-ohm load

Figure 4: Voltage mode; 10 millisecond, 16 volt pulse into 10-ohm load Figure 5: Voltage mode; 100 millisecond, 6 volt pulse into 2-ohm load

Figure 6: Current mode; 100 millisecond, 1 amp pulse into 2-ohm load Figure 7: Current mode; One second, 5 amp pulse into a 2-ohm load

Figure 8: Rise time; voltage mode, 100ms, 16 volt pulse into a 10-ohm load Figure 9: Rise time; current mode, 100ms 4 amp pulse into a 1-ohm load

Figure 10: Time from Interlocks open until output disabled, ~500 microseconds

Specifications AC power source AC current draw Constant voltage output 115/230VAC, 50/60Hz 150VA 0.01 16.00VDC Constant current output 0.001 5.000A Absolute current limit ~ 5.2 amps** Voltage accuracy,.100v-16.00v < 1% * Current accuracy,.100a-5.00a < 2% Time output Time accuracy Compliance voltage Internal series resistance Voltage rise time, 2 Ω load Voltage fall time, 2 Ω load Interlock voltage/current Interlock break to output off.0001 0.9999 seconds 15uS 20VDC ~ 150 milliohms 10 microseconds 10 microseconds +12 volts/12 milliamps 500 microseconds * Internal resistance of safety circuits and current sense resistance create a small voltage error that increases with output current. Error measured over the range of.100v to 16.00V, typically <.070V. ** Internal safety circuits provide absolute current limits of about 5.2A regardless of front panel settings.