Bio Lion Table Top Centrifuge XC-L5

Similar documents
Bio Lion Table Top Centrifuge XC-H165

Centrifuge. Model XC-1000 Operating Manual

Centrifuge. Model XC-2000 Operating Manual

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

L550 Table-Top Low-Speed Large Capacity Centrifuge

Bio Lion CENTRIFUGES.

XCM12 Mini-Centrifuge

Vetlab CombiSpin Centrifuge

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

REFRIGERATED CENTRIFUGE. LRF-A2 Series

INSTRUCTION MANUAL FOR BENCH TOP CENTRIFUGE Z 200 A

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

FD Conveyor for FD 260 Tabber

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200


Centrifuge Operator / Service Manual

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

230VAC Power Inverter 400W Owner s Manual


REFRIGERATED CENTRIFUGE. LRF-A1 Series

L-K INDUSTRIES BENCHMARK S MANUAL

Power Inverter 400 MW Owner s Manual

Operating Manual Cellspin

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Operation Manual Supra R22

58kHz AM Deactivator DB104 Instruction Manual V1.0

Spectrafuge 24DMicrocentrifuge User Manual C2400 C V C V

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

CLEMENTS. Orbital 160 Benchtop Centrifuge. CEN V 50Hz. User Manual. Manual No. CEN Issue 4

User s Manual. Automatic Switch-Mode Battery Charger

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Tissue Master. User Manual


Parts missing or damaged? Questions? Toll-free Helpline

BLOOD BANK REFRIGERATED CENTRIFUGE

Z100A Clinical Centrifuge

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

UTILITY INPUT MAINS OUTLET

Installation/Operating Instructions

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Prism Microcentrifuge

CLEMENTS. Orbital 260 Benchtop Centrifuge. CEN V 50/60Hz. User Manual. Manual No. CEN Issue 5

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA

Stealth Power i-tilt

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Designed in USA, made in China by EEMB Co., Ltd. GUSTO POWER STATION USER MANUAL. LiFePO4 Battery.

Clinispin CT20 User Manual

Meinzer II TM. Testing Sieve Shaker

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

MODEL 853VES. Model 853VES Operator s Manual. Laboratory Centrifuge IVD

Refrigerated. Centrifuge.

Model G14SD Vapor Management System

USER MANUAL. CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1

HERCULES. PROCESS CONTROL VISCOMETER Model M2. User Guide

User Manual Stealth s Power Tilt

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

Source Capture Air Purification System

Intelligent Electronic Safe

(42001) Neck Massager / Masseur de cou User Manual / Manuel de l utilisateur

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

ELECTRIC LIFTING HOIST

INDOOR LED BAR DIGIT HOCKEY SCOREBOARD INSTRUCTION MANUAL REVISION DATE: PART#:

Benchtop Low Speed Centrifuge. Labocon Scientific Limited

HIGH SPEED CENTRIFUGE

1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

Sawhorse with Chainsaw Holder

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

NOTE. Installation and Service Manual Dual Planetary Gearmotor Slim Rack Slide Out System

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

PrO-Cyto Centrifuges 61

3000 SERIES DRY-BLOCK HEAT SOURCE

Blood Centrifuge LBC-100 Series. Labocon Scientific Limited

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

FOR INDOOR/SEASONAL USE ONLY

Lift N Go [Model 210] Electric Carrier For use with power chairs & scooters Installation Guide & Owners Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

Powerful & Intelligent Submersible Pumps

POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Transcription:

Bio Lion Table Top Centrifuge XC-L5 Operation Manual

Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting Page 9-10 Warranty Page 11 This operation manual is for the Model XC-L5. To ensure safety, obtain optimum performance, and to familiarize yourself fully with use of this centrifuge, we recommend that you review this manual thoroughly before operating. Retain this operation manual in an easily accessible place near the work desk for future reference. Specification Max Speed 5000r/min Max Capacity 15ml 32 Max RCF 4390 g Timer range 0~99min Speed accuracy ± 50r/min Noise 65 db(a) Power 110V 60Hz Dimension 440 550 340mm Weight 45 kg 1

Display window see Table II Locking lid Power Switch 2

Rotors (ordered separately) Rotor Item # Table I Max Capacity (ml tubes) Max Speed (r/min) Max RCF ( g) #1 Swing Rotor S016-2-B 50ml 4 5000 4390 #2 Swing Rotor S017-1-B 50ml 8 4000 2810 #3 Swing Rotor S015-1-B 15ml 32 4000 2810 #4 Swing Rotor S008-A 7ml 48 4000 2810 #5 Micro plate Rotor S001 8ml 96 hole 3000 2120 S016-2-B S017-1-B S015-1-B S008-A S001 3

Bio Lion Centrifuges are specially designed for clinical examination and teaching demonstrations in laboratories, colleges and medical fields. They are also ideal instruments for biological, bacteriological, pathological, and pharmaceutical research. Because of higher capability with lower price and humanized configuration design, it is an ideal choice for individuals, schools and scientific research organizations. For users: Caution!- Please read the Operation Manual first. Please verify the correct voltage and frequency of the outlet, before you plug in the unit. The Centrifuge should be controlled by the technical staff and maintained by an approved service technician. Don t use or service the centrifuge before reading the Operation Manual. Use only electrical plug supplied with the equipment. If attempting to replace fuse, make sure centrifuge is unplugged. Make sure the equipment is placed on a flat surface. This equipment is a precision instrument, always use it with care. Avoid dropping or shaking during operation. When moving the equipment, you should use both hands and set it down carefully with equal weight on all 4 corners. Do not put the equipment in direct contact with the sun. Do not expose the equipment to high temperature, damp, or dusty environment. ALWAYS make sure the centrifuge is balanced with equal weight and volume on opposite sides. The balancing weight difference should be no more than 1.5g. For fixed angle rotor, the sample volume should be less than 80% of the tubes total volume. For swing rotor, the sample volume should be less than 90% of the tubes total volume. NEVER use the following material in equipment: Flammable and explosive material. Poisonous and radioactive material. 4

This centrifuge has microprocessor control, brushless motor, real-time change of SPEED and RCF function, and a quick spin feature. In addition, it has several rotor options for the user to select (sold separately). Requirements for Installation: 1. The centrifuge should be stable with the centrifuge weight equally distributed on all 4 rubber feet. 2. Single phase alternating current, 110V/60HZ, with ground wire. DO NOT use voltage converters or extension cords. 3. Humidity level should be less than 85%. 4. There should be at least 6 (150mm) between this unit and other equipment. Table II SET ROTOR SPEED/RCF TIME RCF SHORT ENTER START STOP OPEN SET: Setup button ENTER: Confirm button in set up process SHORT: Button used for quick instantaneous spin START: Start spinning STOP / OPEN: Stop spinning / Door Open button : Up / Increase Button : Down / Decrease button Description of Display window ROTOR: SPEED/RCF: TIME: Displays the rotor number being used Displays speed or RCF value Displays length of time centrifuge will spin 5

Assembly: Turning unit on 1. Insert one side of the plug into the back socket of the centrifuge. The centrifuge must be grounded. Make sure that outlet voltage is in accordance with centrifuge voltage. 2. Turn the power switch located on lower right hand side into the ON position. Set up 1. After unit is powered on push and hold STOP button. This will allow the door to open automatically. Please note door will not open if centrifuge is spinning 2. Visually inspect rotor for any flaw / weak points / or other inconsistency that may cause the rotor to fail. 3. If rotor is not installed then follow Table III and the next step. If already installed, move on to next section. 4. Put some lubricating oil (Not Included) on the motor shaft, install the rotor, washer and secure the nut cap. 5. Make sure securing nut is fastened tightly. Table III Nut Washer Rotor Motor Motor Shaft 6

Choosing the correct rotor 1. Push the SET button to adjust the rotor. The 2 digit number under the word ROTOR should be flashing. If the numbers under ROTOR are not flashing then continue to push the SET button until this happens. 2. Select your rotor by using the following chart and the or arrow buttons 01 refers to 50ml 4, 02 refers to 50ml 8, 03 refers to 15ml 32, 04 refers to 7ml 48, 05 refers to 8 96 hole 3. Push ENTER to confirm. Operation: After the correct rotor has been chosen and installed (see Assembly if this has not been done) then you can add your tubes to the centrifuge. Make sure tubes are correct size and fit in the holders. Press the lid down until the lid is locked and will not open. Speed Adjustment 1. Push the SET button 2 times to adjust the speed setting. The 4 digit number under the word SPEED / RCF should be flashing. If the numbers under SPEED / RCF are not flashing then continue to push the SET button until this happens. 2. This centrifuge default setting for speed is in RPM s. Please select desired speed (shown in RPM s) by using the or arrow buttons. If you would rather adjust speed setting based on RCF values, then push the RCF button to the right of the display window. This will convert RPM into RCF values. 3. Push ENTER to confirm. Time Adjustment 1. Push the SET button 3 times to adjust the time setting. The 2 digit number under the word TIME should be flashing. If the numbers under TIME are not flashing then continue to push the SET button until this happens. 2. Select your desired time (in minutes) using the or arrow buttons. You can set the time from 1 99 minutes. 3. Push ENTER to confirm. 4. If you prefer to run the centrifuge for time less than 1 minute then you can hold the SHORT button down for this time frame. By holding the SHORT button down the centrifuge will run at your desired speed until you release this button. 7

Spinning Centrifuge Now that the correct rotor is selected and your desired speed and time are set you can now run your samples. 1. Make sure lid is closed and locked. 2. Press the START button. 3. After the centrifuge has run for the desired amount of time (when the timer gets down to 0 ) then the centrifuge will slow down. Please note that the speed must reach 0, before you can open the door. 4. When speed reaches 0 the door will open automatically and beep to indicate it has completed the spin. Note This centrifuge has an electronic lock feature. If the unit is unplugged, needs to be opened during a power outage, or for any other reason the lid can not be opened, please insert the emergency lid release tool (looks similar to a screw driver and included with centrifuge) into the lid release on the side (shown below) and open the lid. Emergency hole Maintenance 1. Periodically clean the inside and outside of centrifuge with a lint free cloth. 2. Do not use any caustic cleaning liquids inside centrifuge. 3. Check the rotor before every use. 4. Please turn off and unplug the centrifuge if it is not regularly used. 8

Trouble Shooting: Error Messages Table IV Display E1 E2 E3 E4 E5 E8 Failure Imbalance Over speed Lid Electronic plate motor setup E1 - Imbalance: The weights of the tubes are not equally balanced. Rotor is not installed or spinning correctly Bent or damaged motor shaft. Solutions: Make sure the tubes are equally balanced as described in the Caution section. If it is the Rotor, please double check that everything is assembled correctly as described in TABLE III. If there is any damage, please report to your dealer. E2 - Over speed: Power supply isn t correct. Failing speed sensor Solutions: Check to make sure the voltage and frequency of your outlet are correct, if not, unplug immediately. For any failing equipment, please report to your dealer. E3 Lid: Lid not closed completely. The lid protection device is not working. Solutions: Make sure there is nothing blocking, or jamming the lid; keeping it from closing. For any damaged parts, please report to your dealer. E4 - Electronic plate failure: Failed electronic plate. Solutions: Check out to insure the plug is in good working condition. A failed Electronic plate needs to be replaced. Please report to your dealer. E5 - Motor failure: The connecting line between motor and electronic plate is loose. Motor has failed. Solutions: These failures should be fixed by a professional. Please report to your dealer. E8 - Setup failure: Solutions: Reset the setting in assembly and operation part of manual. Display is not working Unit is not turned on. Check for secure connection of the power cord at the unit back and at the power outlet. Blown fuse, please report to your dealer. 9

Upon receipt of your new Bio Lion centrifuge we recommend you record the following information for future reference: Date purchased/received: Bio Lion Dealer: Dealer s phone number: Warranty The manufacturer warrants this instrument to be free from defects in material and workmanship under normal use for 1 year from the date of purchase. It does not cover damage resulting from abuse or misuse, repairs or alterations performed by unauthorized repair technicians, or damage occurring in transit. If you have questions concerning this product or warranty, contact the dealer from whom it was purchased. For warranty service, centrifuge should be well packed to avoid damage in transit, preferably in original box and packing. Include your complete return address and telephone number as well as a description of the difficulty, date and place of purchase, and ship to the address below. If under warranty it will be repaired or replaced at no charge and returned. If misuse, alterations, accident or abnormal conditions of operation caused failure, an estimate for repairs will be provided for your approval prior to work being performed. Centrifuge Service Department 7241 Gabe Court Manassas, VA 20109-2434 Bio Lion Centrifuges www.bio-lion.com 10