B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Similar documents
Page 2-4 Page 2-8. Page Page 2-13

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

AF40... AF96 3-pole contactors Technical data

Switches Unlimited Phone: * Fax:

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Thermal Overload Relays

For Info: Phone: Fax:

ASL09..S 3-pole Contactors - Spring Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relays EF205 and EF370

Fuse holders and fuses

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Page 2-4 Page 2-8. Page Page 2-12

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relay TF65 and TF96

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Short form catalogue. Motor protection & control

Essential equipment for all your requirements

Thermal overload relay TF140DU and TF140DU-V1000

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Industrial Contactors CTX 3 3P 185A - 800A

Mini contactors B6, BC6 with 3 pole

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Thermal overload relays Type TA Class 10

3 - Protection components Motor circuit-breakers

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Bulletin 193-T1 Bimetallic Overload Relays

CI-TI Contactors and motor starters Types CI 61 - CI 98

C E R T I F I C A T E O F C O M P L I A N C E

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

TAE pole Contactors

Selection Guide Motor Control Device Solutions

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Definite purpose contactors

Manual Motor Starters. Meta-MEC

B Mini Contactor V Hz

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Meta Solution. Contactors and Overload relays

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Square D General Purpose Relays

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Application Description

Star Series Motor protection & control

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Modular contactors and relays

Ktec Contactors and thermal overloads

Thermal Overload Relays - WEG RW Series, 2 Pole

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

CA Z-EN Overload relays, CT-operated overload relays

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

KT4 Manual Motor Starter

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Cylindrical fuse-link

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

DX³ RCCBs - ID 4P up to 100 A

MS General Information Extended Product Type: MS

Safety rope switches with reset for emergency stop

Miniature Circuit Breaker

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

K50H004UP cam changeover switch - 4-pole A - screw mounting

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

BC Mini Contactor VDC

CI-TI Contactors and Motor Starters Type CI 6-50

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Meta Solution. Contactors and Overload relays

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Application Mini Contactors for Motors and Resistive Loads

LK Position Switches TECHNICAL DATASHEET.

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

AE 9... AE 40 Contactors NE... Contactor Relays

Ideal for use as a manual starter

UltraSafe US22 Modular fuse-holders

Protection components

Series L9 UL489 Miniature Circuit Breakers

Micro Contactor MA Series

Technical Information

Description. Positive safety relays

SD Series Non-Fused Load Switches

Transcription:

Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive, manual resetting Type RFNA9, non-phase failure sensitive, automatic resetting. FOR BF SERIES CONTACTORS Type RF8, phase failure sensitive, manual or automatic resetting Type RFN8, non phase failure sensitive, manual or automatic resetting Type RF95, phase failure sensitive, manual resetting Type RFA95, phase failure sensitive, automatic resetting Type RFN95, non phase failure sensitive, manual resetting Type RFNA95, non phase failure sensitive, automatic resetting. FOR B SERIES CONTACTORS Type RF200 and RF420, phase failure sensitive, manual or automatic resetting Type RFN200 and RFN420, non phase failure sensitive, manual or automatic resetting. TYPE OF THERMAL OVERLOAD RELAY Type of contactor Phase failure/single phase sensitive Non phase failure / Page non single phase sensitive Manual/hand Automatic Manual/hand Automatic reset reset reset reset BG06...BG12 RF9 RFA9 RFN9 RFNA9-2 and BF09...BF8 RF8 RFN8 BF50...BF1 RF95 RFA95 RFN95 RFNA95-4 and 5 B115...B180 RF200 RFN200 B250...B400 RF400 RFN400-6 and 7 Page -9 THERMISTOR PROTECTION RELAY 24VDC and 24 to 240VAC supply types. RF8 features FRONT PROTECTION COVER OF THERMAL OVERLOAD RELAYS A sealable protection cover is available. When fitted on to the relay front, it precludes all possible adjuster tampering and involuntary activation of the Reset and Stop buttons of the thermal overload relay. CLEAR IDENTIFICATION OF THERMAL OVERLOAD RELAY MANUAL OR AUTOMATIC RESETTING The RF8 thermal overload relay is supplied configured for manual resetting. Breaking the plate below the Reset button allows for the automatic resetting configuration. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. SEALABLE RELAY COVER A handy closing flap feature excludes any tampering of the thermal overload relay adjuster.

MOTOR PROTECTION RELAYS Thermal overload relays for currents between 0.09 and 420A Phase failure sensitive and non phase failure sensitive versions Automatic and/or manual resetting Independent or direct mounting on contactor Thermistor protection relay. SEC. - PAGE Thermal overload relays For BG series mini-contactors... - 2 For BF series contactors... - 4 For B series contactors... - 6 Accessories... - 8 Electronic relay Thermistor protection relay... - 9... -... - 11... - 12 MOTOR CONTROL AND PROTECTION

Thermal overload relays for BG series mini-contactors Phase failure / single phase sensitive Three poles (three phase) 11 RF9... 11 RFA9... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BG06, BG09, BG12 mini-contactors. 11 RF9 015 0.09-0.15 0.25 1 0.116 11 RF9 02 0.14-0.2 0.5 1 1 0.116 11 RF9 0 0.2-0. 0.5 1 1 1 0.116 11 RF9 05 0. - 0.5 1 2 1 0.116 11 RF9 075 0.45-0.75 1 2 1 0.116 11 RF9 1 0.6-1 2 4 5 0.116 11 RF9 1V5 0.9-1.5 5 0.116 11 RF9 2V 1.4-2. 4 6 5 0.116 11 RF9 2 -. 4 5 0.116 11 RF9 5-5 6 16 15 5 0.116 11 RF9 75 4.5-7.5 8 20 25 5 0.116 11 RF9 6-2 0 5 0.116 11 RF9 15 9-15 16 40 45 5 0.116 AUTOMATIC RESETTING. Direct mounting on BG06, BG09, BG12 mini-contactors. 11 RFA9 015 0.09-0.15 0.25 1 0.116 11 RFA9 02 0.14-0.2 0.5 1 1 0.116 11 RFA9 0 0.2-0. 0.5 1 1 1 0.116 11 RFA9 05 0. - 0.5 1 2 1 0.116 11 RFA9 075 0.45-0.75 1 2 1 0.116 11 RFA9 1 0.6-1 2 4 1 0.116 11 RFA9 1V5 0.9-1.5 1 0.116 11 RFA9 2V 1.4-2. 4 6 1 0.116 11 RFA9 2 -. 4 1 0.116 11 RFA9 5-5 6 16 15 1 0.116 11 RFA9 75 4.5-7.5 8 20 25 1 0.116 11 RFA9 6-2 0 1 0.116 11 RFA9 15 9-15 16 40 45 1 0.116 Three-phase IEC motor powers ❶ 20V 400V 415V 440V 500V 690V [kw] [kw] [kw] [kw] [kw] [kw] ❷ ❷ ❷ ❷ ❷ 0.7 ❷ ❷ ❷ 0.7 0.7 0.55 ❷ ❷ 0.55 0.55 0.55 0.75 0.7 0.55-0.75 0.75 0.75 1.1 1.1-1.5 0.55 1.1 1.1 1.1-1.5 1.5 2.2 0.75-1.1 1.5 1.5-2.2 2.2 2.2 -.7 1.5 2.2- -.7 -.7 -.7 4 2.2.7-4 4.7-4 4-5.5.2 5.5 5.5-7.5 5.5 ❷ ❷ ❷ ❷ ❷ 0.7 ❷ ❷ ❷ 0.7 0.7 0.55 ❷ ❷ 0.55 0.55 0.55 0.75 0.7 0.55-0.75 0.75 0.75 1.1 1.1-1.5 0.55 1.1 1.1 1.1-1.5 1.5 2.2 0.75-1.1 1.5 1.5-2.2 2.2 2.2 -.7 1.5 2.2- -.7 -.7 -.7 4 2.2.7-4 4.7-4 4-5.5.2 5.5 5.5-7.5 5.5 NOTE: Two-pole (single phase) versions are available on request. Add the letter S in the order code e.g. 11RF9015 is three pole; 11RFS9015 two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. ❷ No standard power ratings exist; select relay according to current consumption. NOTE: To facilitate connection between the auxiliary NC contact of the RF...9 thermal relay and terminal A2 of the contactor, insert the conductor into the appropriate conduit as shown. RF9... RFA9... Certifications obtained: c U L C E C u S A C Type s A C C RF9... - RFA9... Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating; the trip current is 120% FLA. CSA CSA certified for Canada only (File 542) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. -2 Accessories page -8 page 2-2 page -11 pages -12 and 1

Thermal overload relays for BG series mini-contactors Non phase failure / non single phase sensitive Three poles (three phase) 11 RFN9... 11 RFNA9... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BG06, BG09, BG12 mini-contactors. 11 RFN9 015 0.09-0.15 0.25 1 0.12 11 RFN9 02 0.14-0.2 0.5 1 1 0.12 11 RFN9 0 0.2-0. 0.5 1 1 1 0.12 11 RFN9 05 0. - 0.5 1 2 1 0.12 11 RFN9 075 0.45-0.75 1 2 1 0.12 11 RFN9 1 0.6-1 2 4 1 0.12 11 RFN9 1V5 0.9-1.5 1 0.12 11 RFN9 2V 1.4-2. 4 6 1 0.12 11 RFN9 2 -. 4 1 0.12 11 RFN9 5-5 6 16 15 1 0.12 11 RFN9 75 4.5-7.5 8 20 25 1 0.12 11 RFN9 6-2 0 1 0.12 11 RFN9 15 9-15 16 40 45 1 0.12 AUTOMATIC RESETTING. Direct mounting on BG06, BG09, BG12 mini-contactors. 11 RFNA9 015 0.09-0.15 0.25 1 0.12 11 RFNA9 02 0.14-0.2 0.5 1 1 0.12 11 RFNA9 0 0.2-0. 0.5 1 1 1 0.12 11 RFNA9 05 0. - 0.5 1 2 1 0.12 11 RFNA9 075 0.45-0.75 1 2 1 0.12 11 RFNA9 1 0.6-1 2 4 1 0.12 11 RFNA9 1V5 0.9-1.5 1 0.12 11 RFNA9 2V 1.4-2. 4 6 1 0.12 11 RFNA9 2 -. 4 1 0.12 11 RFNA9 5-5 6 16 15 1 0.12 11 RFNA9 75 4.5-7.5 8 20 25 1 0.12 11 RFNA9 6-2 0 1 0.12 11 RFNA9 15 9-15 16 40 45 1 0.12 Three-phase IEC motor powers ❶ 20V 400V 415V 440V 500V 690V [kw] [kw] [kw] [kw] [kw] [kw] ❷ ❷ ❷ ❷ ❷ 0.7 ❷ ❷ ❷ 0.7 0.7 0.55 ❷ ❷ 0.55 0.55 0.55 0.75 0.7 0.55-0.75 0.75 0.75 1.1 1.1-1.5 0.55 1.1 1.1 1.1-1.5 1.5 2.2 0.75-1.1 1.5 1.5-2.2 2.2 2.2 -.7 1.5 2.2- -.7 -.7 -.7 4 2.2.7-4 4.7-4 4-5.5.2 5.5 5.5-7.5 5.5 ❷ ❷ ❷ ❷ ❷ 0.7 ❷ ❷ ❷ 0.7 0.7 0.55 ❷ ❷ 0.55 0.55 0.55 0.75 0.7 0.55-0.75 0.75 0.75 1.1 1.1-1.5 0.55 1.1 1.1 1.1-1.5 1.5 2.2 0.75-1.1 1.5 1.5-2.2 2.2 2.2 -.7 1.5 2.2- -.7 -.7 -.7 4 2.2.7-4 4.7-4 4-5.5.2 5.5 5.5-7.5 5.5 NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. ❷ No standard power ratings exist; select relay according to current consumption. NOTE: To facilitate connection between the auxiliary NC contact of the RFN...9 thermal relay and terminal A2 of the contactor, insert the conductor into the appropriate conduit as shown. RFN9... RFNA9... Certifications obtained: c U L C E C u S A C Type s A C C RFN9... - RFNA9... Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating; the trip current is 120% FLA. CSA CSA certified for Canada only (File 542) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. Accessories page -8 page 2-2 page -11 page -12 and 1 -

Thermal overload relays for BF series contactors Phase failure / single phase sensitive Three poles (three phase) RF8... 11 RF95... 11 RFA95... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg ❶ pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Direct mounting on BF09 - BF8 contactors. Independent mounting with RFX8 04 base. RF8 0016 0.1-0.16 0.25 1 1 0.160 RF8 0025 0.16-0.25 0.5 1 1 0.160 RF8 0040 0.25-0.4 0.5 1 1 0.160 RF8 006 0.4-0.6 1 2 1 0.160 RF8 00 0.6-1 2 4 5 0.160 RF8 0160 1-1.6 5 0.160 RF8 0250 1.6-2.5 4 6 5 0.160 RF8 0400 2.5-4 4 6 15 5 0.160 RF8 0650 4-6.5 8 16 25 5 0.160 RF8 00 6.- 20 40 5 0.160 RF8 1400 9-14 16 2 50 5 0.160 RF8 1800 1-18 25 40 70 5 0.160 RF8 200 17-2 25 50 90 5 0.160 RF8 2500 20-25 2 50 0 5 0.160 RF8 200 24-2 40 6 120 1 0.160 RF8 800 2-8 40 6 150 1 0.160 MANUAL RESETTING. Direct mounting on BF50-BF1 contactors. Complete with G261 links. Independent mounting with G270 base. 11 RF95 20-40 6 1 1 0.65 11 RF95 42 28-42 50 80 150 1 0.65 11 RF95 50 5-50 50 0 175 1 0.65 11 RF95 65 46-65 80 125 200 1 0.65 11 RF95 82 60-82 0 200 250 1 0.65 11 RF95 95 70-95 0 200 50 1 0.65 11 RF95 1 90-1 125 200 50 1 0.65 AUTOMATIC RESETTING. Direct mounting on BF50-BF1 contactors. Complete with G261 links. Independent mounting with G270 base. 11 RFA95 20-40 6 1 1 0.65 11 RFA95 42 28-42 50 80 150 1 0.65 11 RFA95 50 5-50 50 0 175 1 0.65 11 RFA95 65 46-65 80 125 200 1 0.65 11 RFA95 82 60-82 0 200 250 1 0.65 11 RFA95 95 70-95 0 200 50 1 0.65 11 RFA95 1 90-1 125 200 50 1 0.65 ❶ UL RK5 fuse class for RF8 types and UL K5 fuse class for RF 95 types. NOTE: Two pole (single phase) versions are available on request. Add the letter S in the order code e.g. RF800 is three pole; RFS800 two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❸ 20V 400V 415V 440V 500V 690V [kw] [kw] [kw] [kw] [kw] [kw] ❷ ❷ ❷ ❷ ❷ 0.06 ❷ 0.06 0.06 0.06-0.09 0.06-0.09 0.09-0.12 0.06 0.09 0.09 0.12 0.12 0.18 0.09 0.12-0.18 0.12-0.18 0.18 0.18 0.25 0.12 0.25 0.25 0.7 0.25-0.7 0.7-0.55 0.18-0.25 0.7-0.55 0.7-0.55 0.55 0.55-0.75 0.75 0.7 0.75 0.75 0.75-1.1 1.1 1.1-1.5 0.55-0.75 1.1-1.5 1.1-1.5 1.1 1.5-2.2 2.2-1.1-1.5 2.2 2.2 2.2-4 1.5-2.2-4 4 4 4-5.5 5.5-7.5 5.5 5.5 5.5-7.5 5.5-7.5 11 4 7.5 7.5-9 9 11 15 5.5 11 9-11 11 11 18.5 5.5 11 11 11 15 22 7.5 15 15 15 18.5 0 11 18.5 18.5 18.5 22 0 7.5 11-15 11-15 15-18.5 15-18.5 22-25 9-15-18.5 18.5-22 18.5-22 22-25 0- -11 22 25 25 0 7-40 15-18.5 25-0 0-0- -40 45-55 22-40 7-45 7-45 45-55 59-75 22-25 40-45 45-51 45-55 55-6 75-80 0 55 55 55 75 90 7.5 11-15 11-15 15-18.5 15-18.5 22-25 9-15-18.5 18.5-22 18.5-22 22-25 0- -11 22 25 25 0 7-40 15-18.5 25-0 0-0- -40 45-55 22-40 7-45 7-45 45-55 59-75 22-25 40-45 45-51 45-55 55-6 75-80 0 55 55 55 75 90 ❷ No standard powers ratings exist; select relay according to current consumption. ❸ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications obtained: Register of c shipping U L L C E C R u S A C O Tipo s A C C S RF8 RF95 RFA95 Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and 000 Amps RMS for 95A and 1A FLA range; the trip current is 120% FLA. CSA CSA certified for Canada only (File 542) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. -4 Accessories page -8 pages 2-2 and 2- page -11 pages -12 and 1

Thermal overload relays for BF series contactors Non phase failure / non single phase sensitive Three poles (three phase) RFN8... 11 RFN95... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg ❶ pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Direct mounting on BF09 - BF8 contactors. Independent mounting with RFX8 04 base. RFN8 0016 0.1-0.16 0.25 1 1 0.160 RFN8 0025 0.16-0.25 0.5 1 1 0.160 RFN8 0040 0.25-0.4 0.5 1 1 0.160 RFN8 006 0.4-0.6 1 2 1 0.160 RFN8 00 0.6-1 2 4 1 0.160 RFN8 0160 1-1.6 1 0.160 RFN8 0250 1.6-2.5 4 6 1 0.160 RFN8 0400 2.5-4 4 6 15 1 0.160 RFN8 0650 4-6.5 8 16 25 1 0.160 RFN8 00 6.- 20 40 1 0.160 RFN8 1400 9-14 16 2 50 1 0.160 RFN8 1800 1-18 25 40 70 1 0.160 RFN8 200 17-2 25 50 90 1 0.160 RFN8 2500 20-25 2 50 0 1 0.160 RFN8 200 24-2 40 6 125 1 0.160 RFN8 800 2-8 40 6 150 1 0.160 MANUAL RESETTING. Direct mounting on BF50-BF1 contactors. Complete with G261 links. Independent mounting with G270 base. 11 RFN95 42 28-42 50 80 150 1 0.65 11 RFN95 50 5-50 50 0 175 1 0.65 11 RFN95 65 46-65 80 125 200 1 0.65 11 RFN95 82 60-82 0 200 250 1 0.65 11 RFN95 95 70-95 0 200 50 1 0.65 11 RFN95 1 90-1 125 200 50 1 0.65 AUTOMATIC RESETTING. Direct mounting on BF50-BF1 contactors. Complete with G261 links. Independent mounting with G270 base. 11 RFNA95 42 28-42 50 80 150 1 0.65 11 RFNA95 50 5-50 50 0 175 1 0.65 11 RFNA95 65 46-65 80 125 200 1 0.65 11 RFNA95 82 60-82 0 200 250 1 0.65 11 RFNA95 95 70-95 0 200 50 1 0.65 11 RFNA95 1 90-1 125 200 50 1 0.65 Three-phase IEC motor powers ❸ 20V 400V 415V 440V 550V 690V [kw] [kw] [kw] [kw] [kw] [kw] ❷ ❷ ❷ ❷ ❷ 0.06 ❷ 0.06 0.06 0.06-0.09 0.06-0.09 0.09-0.12 0.06 0.09 0.09 0.12 0.12 0.18 0.09 0.12-0.18 0.12-0.18 0.18 0.18 0.25 0.12 0.25 0.25 0.7 0.25-0.7 0.7-0.55 0.18-0.25 0.7-0.55 0.7-0.55 0.55 0.55-0.75 0.75 0.7 0.75 0.75 0.75-1.1 1.1 1.1-1.5 0.55-0.75 1.1-1.5 1.1-1.5 1.1 1.5-2.2 2.2-1.1-1.5 2.2 2.2 2.2-4 1.5-2.2-4 4 4 4-5.5 5.5-7.5 5.5 5.5 5.5-7.5 5.5-7.5 11 4 7.5 7.5-9 9 11 15 5.5 11 9-11 11 11 18.5 5.5 11 11 11 15 22 7.5 15 15 15 18.5 0 11 18.5 18.5 18.5 22 0 9-15-18.5 18.5-22 18.5-22 22-25 0- -11 22 25 25 0 7-40 15-18.5 25-0 0-0- -40 45-55 22-40 7-45 7-45 45-55 59-75 22-25 40-45 45-51 45-55 55-6 75-80 0 55 55 55 75 90 9-15-18.5 18.5-22 18.5-22 22-25 0- -11 22 25 25 0 7-40 15-18.5 25-0 0-0- -40 45-55 22-40 7-45 7-45 45-55 59-75 22-25 40-45 45-51 45-55 55-6 75-80 0 55 55 55 75 90 11 RFNA95... ❶ UL RK5 fuse class for RFN8 types and UL K5 fuse class for RF 95 types. NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. ❷ No standard power ratings exist; select relay according to current consumption. ❸ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications obtained: c U L C E C u S A C Type s A C C RFN8 RFN95 RFNA95 Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and 000 Amps RMS for 95A and 1A FLA range; the trip current is 120% FLA. CSA CSA certified for Canada only (File 542) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. Accessories page -8 pages 2-2 and 2- page -11 page -12 and 1-5

Thermal overload relays for B series contactors Phase failure / single phase sensitive Three poles (three phase) RF200... - RF420... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Independent screw fixing or direct mounting on contactors: B115-B145-B180 using G72 links B250-B-B400 using G7 links RF200 0 60-0 0 160 500 1 2.150 RF200 125 75-125 125 200 500 1 2.150 RF200 150 90-150 160 250 500 1 2.150 RF200 200 120-200 200 15 500 1 2.150 Independent screw fixing or direct mounting on contactors: B145-B180 using G75 links B250-B-B400 using G76 links RF420 250 150-250 250 400 800 1 2.460 RF420 00 180-00 15 500 800 1 2.460 RF420 420 250-420 500 60 800 1 2.460 NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers❶ 20V 400V 415V 440V 550V 690V [kw] [kw] [kw] [kw] [kw] [kw] 18.5-25 -51 7-55 7-59 45-6 59-92 22-7 40-6 45-6 51-75 55-80 75-1 25-45 51-80 55-80 55-92 6-0 92-140 7-59 75-0 75-0 75-1 92-140 129-184 45-75 92-12 92-147 0-150 1-162 140-220 55-92 0-162 1-162 129-184 129-198 180-280 75-1 129-198 147-220 150-220 180-280 250-68 NOTE: For 00V powers, consult Customer Service for information; see contact details on inside front cover. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. B115-B400 RELAYS FOR B500 AND B60 CONTACTORS MANUAL OR AUTOMATIC RESETTING. Consult Customer Service for the relative order codes and detailed information; see contact details on inside front cover. Certifications obtained: c U L u E A Type s C RF200 RF420 G72 G7 G75 G76 Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 150A FLA range, 000 Amps RMS for 200A up to 00A FLA range and 18000 Amps for the 420A; the trip current is 120% FLA. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. RF200 RF420-6 Accessories page -8 pages 2-4, 5 and - page -11 pages -12 and 1

Thermal overload relays for B series contactors Non phase failure / non single phase sensitive Three poles (three phase) RFN200... - RFN420... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Independent screw fixing or direct mounting on contactors: B115-B145-B180 using G72 links B250-B-B400 using G7 links RFN200 0 60-0 0 160 500 1 2.150 RFN200 125 75-125 125 200 500 1 2.150 RFN200 150 90-150 160 250 500 1 2.150 RFN200 200 120-200 200 15 500 1 2.150 Independent screw fixing or direct mounting on contactors: B145-B180 using G75 links B250-B-B400 using G76 links RFN420 250 150-250 250 400 800 1 2.460 RFN420 00 180-00 15 500 800 1 2.460 RFN420 420 250-420 500 60 800 1 2.460 NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers❶ 20V 400V 415V 440V 550V 690V [kw] [kw] [kw] [kw] [kw] [kw] 18.5-25 -51 7-55 7-59 45-6 59-92 22-7 40-6 45-6 51-75 55-80 75-1 25-45 51-80 55-80 55-92 6-0 92-140 7-59 75-0 75-0 75-1 92-140 129-184 45-75 92-12 92-147 0-150 1-162 140-220 55-92 0-162 1-162 129-184 129-198 180-280 75-1 129-198 147-220 150-220 180-280 250-68 NOTE: For 00V powers, consult Customer Service for information; see contact details on inside front cover. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. B115-B400 RELAYS FOR B500 AND B60 CONTACTORS. MANUAL OR AUTOMATIC RESETTING. Consult Customer Service for the relative order codes and detailed information; see contact details on inside front cover. Certifications obtained: c U L u E A Type s C RFN200 RFN420 G72 G7 G75 G76 Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 150A FLA range, 000 Amps RMS for 200A up to 00A FLA range and 18000 Amps for the 420A; the trip current is 120% FLA. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. RFN200 RFN420 Accessories page -8 pages 2-4 and - page -11 pages -12 and 1-7

Add-on blocks and accessories for thermal overload relays RFX8 02 RFX8 0 11 G262 RFX8 04 Order code For relay Qty Wt per pkg n [kg] Set of links for direct contactor mounting. 11 G72 RF...200 on B115-B145-B180 1 0.250 11 G7 contactor B250-B-B400 1 0.60 11 G75 RF...420 on B145-B180 1 0.1 11 G76 contactor B250-B-B400 1 0.500 Protection cover for thermal overload relay-contactor assembly. RFX8 02 RF8 on contactor BF09-0.014 BF12 - BF18 - BF25 RFX8 0 RF8 on contactor BF26-0.014 BF2 - BF8 Protection shrouds for power terminals. 11 G262❶ RF...95... 0.00 11 G61 RF...200 6 0.026 11 G6 RF...420 6 0.046 Independent mounting. Screw fixing or 5mm DIN rail (IEC/EN 60715) mounting. RFX8 04 RF...8 5 0.082 11 G270❷ RF...95 0.148 Electrical reset. 11 G228❸ RF...9 - RF...95 5 0.072 Sealing device. RFX8 01 RF...8 - RF...200 - RF...420 0.002 11 G2 RF...9 - RF...95 1 0.006 Electric button NO. 11 G244 RF...9 - RF...95 0.011 Marking element. 11 RB6 RF...9 - RF...95 0 0.00 Set of 0 alphanumeric symbol. 958❹ RF...9 - RF...95 1 0.002 ❶ Front IP20 protection is warranted to contactor-thermal relay connections. ❷ Independent mounting base for any RF95 relay. Remove the links fixed on RF...95 and use those supplied with the base. ❸ Replace with voltage digit. Standard voltages are: AC 50/60Hz 24V / 48V / 1-125V / 220-240V / 80-415V. ❹ Replace with the required alphanumeric symbol. Each package contains 0 pieces of the same symbol. Operational characteristics ELECTRICAL RESET G228 Control circuit voltage AC (50/60Hz) V 12-550 Power consumption in AC VA 00 Minimum reset time ms 20 Terminals Faston 6.x0.8 NOTE: Coils can remain supplied for a maximum interval of 500ms; consecutive operations are allowed, followed by a 5 minute interval. Reset only if at least 1min has passed from overload tripping. It is recommended to use the wiring diagram on page -11. INDIPENDENT MOUNTING Conductor cross section with one cable: 6...mm 2 / AWG 8 for RFX8 04 5mm 2 / AWG 2 for G270 Tightening torque: 2...2.5Nm / 1.5...1.8 lbft for RFX8 04.9Nm/2.88 lbft for G270. Certifications obtained: c U L C E u S A Tipo s A C G61 G6 G72 G7 G75 G76 G270 RFX8 04 Certified products. culus UL Listed for USA and Canada (culus - File E9601) as Auxiliary Devices for thermal overload relays. CSA CSA certified for Canada only (File 542) as Kits for industrial control equipment. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n 14. 11 G228 11 G244 Combinations G262 (per RF...95 ) G72 G7 G75 G76 G270 G61 G6 RF...200 RF...420 RFX8 01 RFX8 04 RF...95 G2 G228 RF...9 RB6 958... G244 RF...8 RFX8 01-8 page - page -11 pages -12 and 1

Add-on blocks and accessories for thermal overload relays. Electronic relay and accessory Protection cover for thermal overload relay-contactor assembly BF09-BF25 BF26-BF8 RF...8 RFX8 02 RF...8 RFX8 0 Thermistor protection relay 1 DRPT... Order code Rated auxiliary Qty Wt. supply voltage per pkg [V] n [kg] DC supply (version for 5 mm DIN rail IEC/EN 60715). 1 DRPTC 24 24VDC❶ 1 0.269 AC supply (version for 5 mm DIN rail IEC/EN 60715). 1 DRPT 24 24VAC 1 0.269 1 DRPT 1 1VAC 1 0.269 1 DRPT 220 220-240VAC 1 0.269 ACCESSORY Order code Description Qty Wt per pkg n [kg] 1 CE6 Adapter for screw 0.008 fixing of DRPT relay on mounting plate. ❶ Galvanic isolation between supply and measuring circuits does not exist. General characteristics The DRPT is a thermal protection relay for motors equipped with thermistor PTC sensors immersed in the winding heads. The maximum number of thermistors to be used is limited by the resistance of all the sensors connected in series; total ohmic value is not to exceed 1.5kΩ at 25 C. The DRPT type has fail-safe operation: the protective feature trips even in the case the PTC circuit is disconnected or there is a lack of voltage. Resetting is manual or automatic. Operational characteristics Supply circuit Rated frequency: 50-60Hz for AC types only Operational limits: 0.85-1.1 Us Maximum dissipation: 2.5W Connection: permanent. Measuring circuit Type of connectable PTC sensor: According to DIN 44081 Total PTC resistance at 25 C: 1.5kΩ Tripping resistance: 2.7-.1kΩ Resetting resistance: 1.5-1.8kΩ Voltage at PTC terminals: 2.5VDC. Remote resetting Control: NC contact opening Contact voltage: 5VDC Current consumption: about 1mA. Relay output Arrangement: 1 relay with 2 changeover contacts Rated operational voltage Ue: 250VAC Conventional free air thermal current Ith: 5A Designation to IEC/EN 60947-5-1: B00 Mechanical life: 50x 6 cycles Electrical life (with rated load): 2x 5 cycles. Indications Green LED indicator for power ON Red LED indicator for relay state TRIP Connections Conductor section 2x1.5mm 2 with ferrule (max) Tightening torque: 0.8-1.2Nm. Ambient conditions Operating temperature: -...+60 C Storage temperature: -0...+80 C. Housing Snap on 5mm DIN rail (IEC/EN 60715) For screw fixing, use CE6 adapter Degree of protection IP40 housing IP20 terminals. Certifications obtained: EAC. Compliant with standards: IEC/EN 60255-5. page - page -11-9

[mm (in)] RFX8 04 base c/w RF...8 thermal relay G270 base c/w RF...95 thermal relay 7.9 (0.1 ) 45 (1.77 ) 14.6 (0.57 ) 4 (1.4 ) Ø4.2 (0.16 ) 88.4 (.48 ) 8 (.27 ) 9.7 (0.8 ) 55 (2.16 ) 16.5 (0.65 ) 4 (1.69 ) Ø4.2 (0.16 ) 2 (4.01 ) 95.4 (.75 ) 70. (2.77 ) 7.5 (2.89 ) 79 (.11 ) 85 (.5 ) 7.9 (0.1 ) 14.6 (0.57 ) RF...200 thermal relay with links G72 and G7 11 (0.4 ) 16.5 (0.65 ) 2.8 (0.94 ) 127.5 (5.02 ) 40 40 166.1 (6.54 ) 122 (4.80 ) G72 G7 11.4 (4.46 ) 74 (2.91 ) 172 (6.77 ) 8.6 (1.52 ) Ø5.4 (0.21 ) 20 (0.79 ) 40 40 M8 56.5 (2.22 ) RF...420 thermal relay with links G75 and G76 25 (0.98 ) 145 (5.71 ) 47.5 47.5 165.4 (6.51 ) 15. (6.0 ) G75 G76 Ø5.4 (0.21 ) 121.2 (4.77 ) 74 (2.91 ) 189.6 (7.46 ) 44.8 (1.76 ) 25 (0.98 ) 47.5 47.5 M 56.8 (2.24 ) ADD-ON BLOCKS FOR THERMAL OVERLOAD RELAYS RF...9 and RF...95 G228... reset G244 button 6 (2.48 ) 19 (0.75 ) 89.7 (.5 ) 1. (0.52 ) 54.5 (2.14 ) (0.9 ) 5.8 (1.41 ) 5.8 (1.41 ) 26.7 (1.05 ) THERMISTOR PROTECTION RELAY DRPT relay 45 (1.77 ) 0 (.94 ) CE6 adapter 22.5 (0.88 ) (0.9 ) 79 (.11 ) 84 (.0 ) 94 (.70 ) Ø4.5 (0.18 ) -

THERMAL OVERLOAD RELAYS FOR BG MINI-CONTACTORS RF9 - RFN9 95 97 TEST RESET L1 L2 L 1 5 RFA9 - RFNA9 95 L1 L2 L 97 1 5 96 98 T1 T2 T 96 98 T1 T2 T THERMAL OVERLOAD RELAYS FOR BF CONTACTORS RF8 - RFN8 RF95 - RFN95 RFA95 - RFNA95 95 STOP 97 TEST RESET L1 L2 L 1 5 95 97 TEST RESET L1 L2 L 1 5 95 L1 L2 L 97 1 5 96 98 T1 T2 T 96 98 T1 T2 T 96 98 T1 T2 T THERMAL OVERLOAD RELAYS FOR B CONTACTORS RF200 - RFN200 RF420 - RFN420 95 STOP 97 TEST RESET 1 5 L1 L2 L 1 5 96 98 T1 T2 T ADD-ON BLOCKS FOR THERMAL OVERLOAD RELAYS RF9 - RF95 Electric reset L1 L2 L G228 A1 1 BF... 5 A2 2 4 6 R TEST RESET E1 G228... 95 97 1 5 E2 96 98 RF... L L1 T1 T2 T THERMISTOR PROTECTION RELAY DRPT L1 L2 L 24VDC 24VAC 1VAC 220...240VAC Remote reset F2 S1 Set point Hysteresis C A1 A2 Automatic Reset Manual Reset Remote Reset F1 TEST 1 5 A1 T1 T2 S1 11 21 RESET K1 K1 T2 S1 2 4 6 A2 DRPT 12 14 22 24 ON S2 TRIP M1 S K1 11 12 14 Rmax =1.5kΩ (25 C) K1 21 22 24-11

Phase failure/single phase sensitive hand reset RF9 RF8❶ RF95 RF200❶ RF420❶ Phase failure sensitive automatic reset RFA9 RFN8❶ RFA95 RFN200❶ RFN420❶ Non phase failure/non single phase sensitive hand reset RFN9 RFN95 Non phase failure/non single phase sensitive automatic reset RFNA9 RFNA95 POWER CIRCUIT CHARACTERISTICS IEC rated insulation voltage Ui V 690 690 690 00 00 IEC rated impulse withstand voltage Uimp kv 8 6 8 6 6 Frequency limit Hz 0-400 0-400 0-400 50-60 50-60 Operational range from A 0.09 0.1 14 60 150 to A 15 8 1 200 420 ❷ Tripping class A Particular characteristics Test button - Trip indicator Connection Direct With current transformers ❸ Yoke Terminals Type Screw and washer clamp Screw and flat washer Screw M4 M4 M5 M8 M Terminal width mm 9.8 12.6 9 20 25 Phillips n 2 2 2 1mm❹ 18mm❹ Tightening torque Nm 2. 2...2.5.9 18 5 for power terminals lbft 1.7 1.5...1.8 2.88 1. 25.9 Maximum conductor section connectable AWG N 8 2 -- -- Flexible w/o lug mm 2 6 5 -- -- Flexible c/w lug mm 2 6 -- 150 2 x 150 Bar mm -- -- -- 25 x 0 x 5 Dissipation per phase W 0.7-2.4 0.7-2.4 2.0-4.2 0.7-2.4 0.7-2.4 AUXILIARY CIRCUIT CHARACTERISTICS Available NO n 1 contacts NC n 1 IEC rated insulation voltage V 690 IEC conventional free air A thermal current Ith Terminals with Screw M.5 screw and washer Terminal width mm 8 Phillips n 1 2 1 2 2 Maximum conductor section connectable Flexible w/o lug mm 2 2.5 Flexible c/w lug mm 2 2.5 Tightening torque Nm 1 0.8...1 1 0.8...1 0.8...1 for auxiliary terminals lbft 0.74 0.59...0.74 0.74 0.59...0.74 0.59...0.74 UL/CSA and IEC/EN 60947-5-1 designation B600 - P600 B600-R00 B600-P600 B600-R00 B600-R00 ❺ ❺ AMBIENT CONDITIONS Operating temperatureo C -20...+55-25...+60-20...+55-25...+60-25...+60 Storage temperature C -55...+70-50...+70-55...+70-50...+70-50...+70 Compensation temperature C -15...+55-20...+60-15...+55-20...+60-20...+60 Maximum altitude m 000 Operation position Normal On vertical plane Allowable ±0 Mounting On contactor or separately ❶ With manual and automatic resetting. ❷ For currents higher than 420A, consult Customer Service for information; see contact details on inside front cover. ❸ Standard supplied. ❹ Metric wrench/spanner. ❺ C600-R00 for automatic reset type. -12

TRIP CHARACTERISTIC FOR RF THERMAL OVERLOAD RELAYS (AVERAGE TIME) Three-phase balanced operation RF9 RF8 RF95 RFA9 RFN8 RFA95 RFN9 RFN95 RFNA9 RFNA95 Opening time [s] 000 2h Two-phase operation (phase failure/single phase) RF9 RF8 RF95 RFA9 RFA95 Opening time [s] 000 2h 1h 1h 0min 0min 00 min 00 min 5min 5min 2min 0 2min 0 1min COLD 1min COLD HOT HOT 1 1.05 1.2 1.5 2 4 5 6 7 8 9 1 x Ie [A] 1 1.15 1.5 2 4 5 6 7 8 9 x Ie [A] 1 RF200 RFN200 RF420 RFN420 RF200 RF420 Opening time [s] 000 2h Opening time [s] 000 2h 1h 1h 0min 0min 00 00 min min 5min 5min 2min 0 2min 0 COLD 1min 1min COLD HOT HOT 1 1.05 1.2 1.5 2 4 5 6 7 8 9 1 x Ie [A] 1 1.15 1.5 2 4 5 6 7 8 9 x Ie [A] 1 Tripping times can have a ±20% deviation with respect to the average tripping curve values above. -1