Product Installation Document

Similar documents
DC CCTV Power Supplies Installation Guide

All hardware is mounted in steel enclosure (see dimensions below) and includes a HT28100 transformer and a single power supply board.

CCTV Rack Mount Power Supplies

SMP3CTX Series Power Supply/Charger

CCTV Rack Mount Power Supplies

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

AL600ULX Series. Power Supply/Charger Installation Guide

Powerware Vdc Extended Battery Cabinet User s Guide.

User Manual 200Ah INVERTER / CHARGER

Rack Mount Power Supplies

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Installation Instructions

Installation Instructions Central Battery Units

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

Installation Instructions

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

Solar Charge Controller

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

SCC-MPPT Solar Charge Controller

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

AccuPower AQU126B Installation Instructions

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

AccuPower AQU128B Installation Instructions

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

BATTERY SAVER LOW RIPPLE HO

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

PSU EN54-4 Power Supplies

IMPORTANT SAFEGUARDS

BRAVER UPS. (Uninterruptible Power System) User s Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

- 8 amp (200VA) - 8 amp (200VA) - Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

POWERLINE 2000 Energy Management System TM

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Elmdene International Ltd

GES-202TLP Traffic Light System Installation Manual

User Manual. Solar Charge Controller 3KW

Power Inverter 400 MW Owner s Manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

WF-5110R True Sine Wave Inverter

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

General Precautions. Personnel Precautions

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Switching DC Power Supply

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

Battery Equalizer. Table of Contents Introduction. 2. Specifications.. 3. Theory of Operation Typical Applications... 5

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

SAVE THESE INSTRUCTIONS

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Installation and Operation Instructions 10/04/13

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Pulsar Evolution 2200/3000/3000 XL

Installation Instructions and User Manual For. 100 Watt Inverter Power System

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Uninterruptible Power Supply

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

WF-5110R True Sine Wave Inverter

Industrial Power Supplies

30A SMART ENERGY MANAGEMENT SYSTEM TM

INSTALLATION GUIDE AND USER MANUAL

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

FieldView External Charger. User Guide

MASTERsine Inverter PXA Series Installation Guide

M Series External Battery Frame. User Guide

LEAD ACID BATTERY CHARGER

Model VC volt to 12 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

AUTO CHARGE LPC SERIES

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

PBA Series Prelube Controls

Eclipse Plus VA UPS and Surge Suppressor User s Manual

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

Transcription:

Honeywell 12 Clintonville Road Northford, CT 064721610 http://www.honeywellpower.com HP1205UL4, HP1205UL8, HP12010UL8, HP1210UL16 Power Supplies/Distribution Units PN 0618131: A 07/18/13 Product Installation Document 1. Overview: These switching power supplies/distribution units convert 120VAC input into 12VDC at 5.5 amps or 11 amps of continuous supply current. Built in distribution boards allow for power delivery across multiple outputs while offering electronically fused protection on each circuit. These generalpurpose power supplies have a wide range of applications for access control, security and CCTV systems that require additional power. For convenient installation, they come completely assembled with a compact steel enclosure, power cord and all connecting hardware. 2. Features: Designed for quick installation. Individually protected, electronically fused outputs. Built in battery backup/charger on selected models(see below) Short circuit isolation technology for uninterrupted operation. Class 2, Power limited outputs. Removable output terminal blocks for quick installation Diagnostic LEDs for quick troubleshooting. Automatic switch over to standby battery. AC line cord included. 3. Specifications: UL/CUL listed to UL60950 Information Technology Equipment. CE/LVD EN609501 CE/EMC:EN55022,EN55024 FCC PART 15, ICES 0032012 Maximum temperature range:20 C to 40 C; (For indoor use only.) Relative humidity: 20% ~ 90% 85% of Efficiency with full load. Maximum ripple 150mVpp, Maximum noise 200mVpp Builtin charger (on select power supplies) for sealed lead acid battery. Individual outputs current limited at 2.5 Amps per circuit. Maximum battery charge 500mA (Subtract from total output). Red LED s indicate DC power presence on each circuit. Products Power output Number of Battery Enclosure dimensions outputs Charger HP1205UL4 12VDC@5.5 Amps 4 No 9.25. x 8.25 in. x 3.5 (23.3 cm x 21 cm x 9 cm) HP1205UL8 12VDC@5.5 Amps 8 Yes 9.25. x 8.25 in. x 3.5 (23.3 cm x 21 cm x 9 cm) HP1210UL8 12VDC@11 Amps 8 Yes 17 L x 13.5 W x 4.75 H (43.2 cm x 34.3cm x 12.06 cm) HP1210UL16 12VDC@11 Amps 16 Yes 17 L x 13.5 W x 4.75 H (43.2 cm x 34.3cm x 12.06 cm) Note: When using the battery charger(s) on applicable power supplies for backup /charging, 500mA needs to be subtracted from the total output power listed above in table for each battery charger.

Products AC current draw (Full load) 120VAC@50/60hz AC current draw (Full load) 240VAC 50/60Hz Max output per circuit Number of batteries required for backup HP1205UL4 1.3Amps 650mA 2.5Amps 0 HP1205UL8 1.3Amps 650mA 2.5Amps 1 HP1210UL8 2.6Amps 1.3Amps 2.5Amps 2 HP1210UL16 2.6Amps 1.3Amps 2.5Amps 2 Equipment is to be installed and serviced by authorized / trained personnel only. Installation should conform to all local codes and in accordance with the National Electrical Code. Remove branch circuit power before installing / servicing equipment. Product is intended for indoor use only. 4. Installation Instructions: 1. Unpack product. Do not discard packaging material until installation is complete. 2. Predrill holes on the wall where enclosure is to be mounted. Choose a vertical surface (wall) strong enough to support the full weight of the assembly. Select a mounting location in an area without excessive moisture; for indoor installation only and in a secured area (Electrical Room). 3. Secure enclosure to the desired wall location with the appropriate sized fasteners using the four mounting holes in the cabinet. 4. Disconnect power to the branch circuit to which the product will be connected. 5. Connect incoming AC power (120 V, 60 Hz): Hot (L1) (black) to terminal marked L. Neutral (L2) (white) to terminal marked N. Ground (Green) to terminal marked G. 6. Use the knockout in bottom of cabinet for 120 VAC wiring. Route the 120VAC wiring at least 1/4" from (low voltage) wiring. 7. Keep a 1/4" (0.635 cm) separation between powerlimited wiring and onpowerlimited wiring. Use separate knockouts for power limited wiring. 8. Connect CCTV cameras (or other external loads) to appropriate terminals shown in Fig 1: Connect circuit #1 to terminals marked and. Connect circuit #2 to terminals marked VO2 and VO2. Continue to connect the remaining circuits, carefully observing polarity. 9. Power the branch circuit and observe red output LEDs illuminated. Illuminated LEDs 14 or 18 mean that Dc power is present on outputs. 10. To avoid potential damage, verify that output voltage and load current does not exceed output limitations. (A single extinguished LED can mean an overload condition) See troubleshooting guide for more information. 11. For Battery backup: If battery backup is required on selected models, using the provided battery leads, connect the Lead Acid battery(s) 7AH 12V to the battery charger terminals while carefully observing polarity. Set the output voltage on the trim pot shown in to 13.8VDC for proper charging. Battery(s) not supplied with the finished power supply unit. We suggest to use Power Sonic Battery part NO. PS1270, UL File NO.MH20845 or any Recognized Lead Acid UL Battery of same capacity and type,7ah 12V. 12. G N L LED 1 LED 2 LED 3 LED 4 1 2 3 4 Connecting AC Power Hot (L1) Connects to L Neutral (L2) Connects to N Eath Connects to G Upon completion of wiring, secure the cabinet door with screws supplied (or the included lock on the HP1210UL8 and the HP1210UL16 models) to prevent access by unauthorized personal. Voltage Adjust

5. Maintenance/Troubleshooting Product should be tested annually for proper functionality. Normal verification of proper operation includes measuring all outputs with a voltmeter under normal load conditions to ensure output voltage is present. Trouble shooting tips: Symptom Check for All output LEDs are extinguished Measure for proper input voltage (120VAC/240VAC) using an AC voltmeter. Verify total output load. Check for overload/short circuit condition on all outputs. Remove short or overload condition. Single output LED is extinguished Verify output load on circuit. Check for overload/short circuit condition. Remove short or overload condition. Battery not charging. Measure battery charger voltage to ensure 13.8VDC is present. Check battery to make sure it is not worn out or defective. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. RISK OF ELECTRICAL SHOCK AND/OR EQUIPMENT DAMAGE. DISCONNECT POWER BEORE SERVICING THIS APPLIANCE. MAINTAIN A 1/4" OF SEPARATION BETWEEN THE AC MAINS AND ALL LOW WIRING. A READILY ACCESSIBLE SWITCHED CIRCUIT BREAKER MUST BE AVAILABLE TO DISCONNECT MAIN POWER AS REQUIRED. THIS UNIT CONTAINS NO USERSERVICEABLE PARTS, INSTALLATION AND SERVICING SHOULD ONLY BE MADE BY QUALIFIED PERSONEL. INSTALL IN ACCORDANCE WITH LOCAL REGULATIONS AND NATIONAL ELECTRIC CODE. CAUTION: RISK OF EXPLOSION IF IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. For additional information: Visit our website at http://www.honeywellpower.com Contact Technical Support at (877) HPPPOWR Email us at HPP.techserv@Honeywell.com

HP1205UL 4 Output Terminal Block for circuits 14 and Voltage A MINIMUM OF 1/4 SHALL BE LED 41 LED 23 LED 32 LED LED 4 1 HP1205UL 8 Output Terminal Block for circuits 14 and Voltage BAT 12054CBPCB LED 5 LED 6 LED 7 LED 8 VO8 5 VO7 6 VO6 7 VO5 8 A MINIMUM OF 1/4 SHALL BE Output Terminal Block for circuits 58 and Voltage LED LED 41 LED 23 LED LED 32 LED LED 4 1 VO8 1 VO7 2 VO6 3 VO5 4 Keep.25 spacing between powerlimited wiring and non powerlimited wiring

HP1210UL 8 POWER MODULE 1 BAT 12054CBPCB POWER MODULE 2 BAT 12054CBPCB Power Module 1: Output Terminal Block for circuits 14 VO4 VO3 VO2 FACTORY INSTALLED AC WIRING VO4 VO3 VO2 CLASS 2 POWER LIMITED OUTPUTS Power Module 2: Output Terminal Block for circuits 14 A MINIMUM OF ¼ SHALL BE VO8 1 VO7 2 VO6 3 VO5 4 Keep.25 spacing between powerlimited wiring and non powerlimited wiring

HP1210UL 16 POWER MODULE 1 POWER MODULE 2 Power Module 1: Output Terminal Block for circuits 14 BAT 12054CBPCB BAT 12054CBPCB VO8 VO7 VO6 VO5 LED 4 LED 3 LED 2 LED1 VO4 VO3 VO2 FACTORY INSTALLED AC WIRING VO8 VO7 VO6 VO4 VO3 VO2 VO5 LED 4 LED 3 LED 2 LED1 CLASS 2 POWER LIMITED OUTPUTS Power Module 1: Block for circuits 58 and Voltage A MINIMUM OF ¼ SHALL BE VO8 1 VO7 2 VO6 3 VO5 4 Power Module 2: Output Terminal Block for circuits 1 Power Module 2: Output Terminal Block for circuits VO8 1 VO7 2 VO6 3 VO5 4 Keep.25 spacing between powerlimited wiring and non powerlimited wiring