SE10-24 Volt Operating Manual

Similar documents
LD Operating Manual S A ELECTRONIC USTRALIA. LD Volt Owners Manual. Warnings and electrician s notes Hints and Pointers Examples

SELECTRONIC AUSTRALIA

SELECTRONIC AUSTRALIA

SPI SS SPI SS Owners Manual

SPI 600i-12SS SPI 600i-24SS Owners Manual

o p e r at i o n & i n s ta l l at i o n m a n u a l SOLAR ENERGY AUSTRALIA Pty Ltd ACN

SELECTRONIC AUSTRALIA

GSL Electronics Modified Sine Wave Power Inverters

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

ATD WATT INVERTER

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

ATD WATT INVERTER

Battery Power Inverters

Voyager. operation & installation manual. High Performance Sine Wave Inverter SEAP-24-1K7 SEAP-48-1K7. Serial No: Model No:

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

DC TO AC POWER INVERTER

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

JUMP STARTER OPERATOR S MANUAL RA1900

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Bunya Solar. Renewable Energy Systems. Remote area power supply system manual

Owner s Manual. PowerVerterDC-to-AC Inverter

Matson Jump Starter Operator s Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

OWNER S MANUAL Please read this manual before operating your power supply

PROwatt 150 DC to AC Power Inverter. Owner s Guide

Pure Sine Wave Inverter 600W-24V User Manual

DC/AC Sinewave Inverters 500W to 7000W

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL

1000-Watt Energy Center

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00

MEANWELL DC/AC POWER INVERTERS

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

LIGHTNING PROTECTION UNIT (LPU)

OWNER S MANUAL POWER INVERTER

12VDC TO 230VAC INVERTERS

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Roller Door Operator

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

user s manual Model number

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

PRO-WAVE INVERTER 12 VOLT, PURE SINE WAVE. P/No.s PW150, PW350, PW600, PW900 & PW1800

PRO-WAVE INVERTER 12 VOLT, 150W PURE SINE WAVE

INSTRUCTION MANUAL LS SERIES. SINEWAVE INVERTER 2000W to 7000W. and WARRANTY REGISTRATION CARD. web:

4. TECHNICAL SPECIFICATIONS

Lithium Power Supply

AeroVironment Universal Solar Pump Controllers

AL-KO ESC USER MANUAL

O W N E R ' S M A N U A L

Dual Voltage Solar Power Charge Controller Board Connection & Operation V2.xx

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

Manual Installation & Operation

MODEL No s: PP3, PP3K

Inverter User Manual

INSTRUCTION MANUAL LS SERIES SINEWAVE INVERTER. Latronics P.O. Box 73 Moffat Beach Qld 4551 AUSTRALIA. and WARRANTY REGISTRATION CARD

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Item no Smart AC 200 USB. User s Manual

powerdriveinverters.com Owner s Guide Please Save for Future Reference 300 Watt DC to AC Power Inverter

User s Manual. Automatic Switch-Mode Battery Charger

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

230VAC Power Inverter 400W Owner s Manual

Owner s Manual. Contents GP-PWM-10-SQ

SAFETY WARNINGS AND GUIDELINES

IN120L / IN120LB / TM120L/TM120LB IN2400L

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

Installation and Maintenancee Manual

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Power Inverter 400 MW Owner s Manual

Pure Sine Wave Inverter Charger

IN & TM Series User Manual

Eclipse Plus VA UPS and Surge Suppressor User s Manual

12V 160W Folding Portable Solar Panel Kit KDSLR160PNLA User Manual

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

You re never left in the dark.

Item No. : Power Dome LT. User s Manual

HPP1 MK5 Owner s Manual

Car Battery Charger Instructions for Use

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

SP6. Automatic Battery Charger. Model

3000W POWER INVERTER. User Manual

POLYCRYSTALLINE SOLAR PANELS. (MC4 Series) P/No SPP80-MC4, SPP120-MC4, SPP135-MC4, SPP150-MC4

BATTERY CHARGER-STARTER

WARNINGS, CAUTIONS AND NOTES

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

1200+ WITH TIMER V1.00 OWNERS MANUAL

12 VOLT SOLAR PANEL KITS MONOCRYSTALLINE. P/No. SPP160K

Owner s Guide. DC TO AC Power Inverter

MA20DC MA20DCS 20 AMP, DC TO DC BATTERY CHARGER 20 AMP, DC TO DC BATTERY CHARGER WITH SOLAR INPUT

Pure Sine Wave Inverter USER MANUAL

Transcription:

SE10-24 Volt Operating Manual Serial N o Purchase Date Note - Your 2 Year Warranty can only be valid once your warranty card is completed and returned to Selectronic Australia SELECTRONIC AUSTRALIA

SE10-24 Volt Owners Manual Contents Page No. Introduction 1 Warranty Card 1 Installation 1-3 Batteries and Connections 4-5 System Wiring 6-7 Getting Started Quickly 7 Parts Identification 8 Operation 9 STATUS Indicators 9-10 Voltmeter 11 Auto Start Setting 11-12 Low Voltage Shutdown Setting 12 Maintenance 13 Inverter 13 Batteries 13-14 Other System Components 14 Handy Hint 14 Radio Frequency Interference 15 Fault Finding 16 Product Warranty Conditions 17 Specifications 18-19 Selectronic Service Network 20 Legend for Symbols Warnings and electrician s notes Hints and PointerszExamples

Introduction Thank you for choosing to purchase the Selectronic SE10 TRUE SINE WAVE inverter. Many hours of Research and Development have gone into the SE10 to ensure this inverter provides you with many years of reliable service Warranty Card It is imperative that you complete your warranty card NOW. Your SE10 is covered by a TWO year warranty. This warranty is in addition to your rights under the trade practices act of your state or territory. Returning you completed warranty card will enable us to register your warranty and avoid any possible delays should service be required. If you have any comments about our product that will not fit on the warranty card please feel free to drop us a line. Yes, constructive criticism will also be welcome. Installation 200mm 200mm 200mm SE10 Inverter 200mm SE10 Inverter Front Please leave a clearance of 200mm on all sides and top of the Inverter. The SE10 must be installed in a dry, cool, dust-free environment. It is recommended that the inverter be placed as far from any radio receivers as possible. SE10 Manual 1 Selectronic Australia

Large amounts of DC current can be drawn by your SE10, care must be taken. Fixed Installation All fixed installation battery connections must be securely bolted, using stainless steel nuts and bolts. To protect the connection from corrosion smear a small amount of Vaseline or similar over the joint. Never place batteries directly onto a concrete floor, place timber or similar material beneath the batteries. Battery Bank *System Fuse SE10 Inverter To electrician s Switchboard RFI / Lightning Earth * A system fuse (of at least 20 Amps) should be placed before the battery. An HRC motor start type is recommended. (See your system designer for details). Warning As a matter of safety, Selectronic strongly recommend that all fixed installations be designed and installed by appropriately qualified person. The Solar Energy Industries Association in your state or territory can provide names of accredited system designers and installers. The output voltage from an inverter is as lethal as mains electricity. All AC wiring MUST be carried out by an accredited electrician and must conform to AS3000 and/or any relevant local standards. Electrician s Note All earth s AC and DC should be bonded RFI/Lightning Earth stake should be within 3m of the inverter The SE10 is suitable for connection to MEN wiring Any AC changeover switch must be a break before make type SE10 Manual 2 Selectronic Australia

Portable Use By using optional battery clips, the SE10 can be connected directly to a vehicle battery. When using Alligator clips ensure they have a tight grip around the battery post. Wherever possible battery connections should be bolted. If connecting the SE10 through a cigarette lighter socket the maximum power output of the SE10 will be severely restricted, this practice should be avoided. Check with your supplier or installer if you are unsure. Do not use alligator clips in a moving vehicle Start Battery Earth (to chassis) Isolator SE10 Inverter Vehicle Alternator Auxiliary Battery Earth (to chassis) By incorporating an auxiliary battery in the manner above, the starting battery should remain charged for vehicle starting (see your auto electrician). The SE10 has sufficient battery cable length to allow it to sit underneath the vehicle whilst in use. If the ground is wet, place the SE10 on a waterproof liner. SE10 Manual 3 Selectronic Australia

Batteries and Connections Batteries are the key to maximum performance from your SE10, if a battery is too small or not fully charged it may result in de-rated performance from your SE10. Battery ratings Batteries can be rated in one of two ways: 1. CCA = Cold Cranking Ability. This is the amount of power or current that a battery can deliver for a short period, typically a few seconds. This how a car battery would normally be rated. 2. Ah = Ampere Hours. This is the maximum amount of energy that can be stored in a battery; this figure will generally be stated at a particular hour rate. This is how a deep cycle or storage battery would normally be rated. 100Ah @100hr, this means that when this battery is discharged over a period of 100 hours, the battery has a capacity of 100Ah. This in theory means 1 Amp for 100 hours, although this would in practice result in a totally discharged battery that may not then recover. To achieve maximum performance from your SE10 you must have a battery capable of delivering 50 Amps for a short period whilst maintaining at least 21 volts. To provide a 24 volt supply to your SE10 you will need to join more than one battery together. Where batteries are joined in series, add the voltage of each battery. The capacity will equal the capacity of the smallest battery. 2 x 12 volt 100 Ah batteries connected in series would have a total capacity of 24 Volts 100 Ah. SE10 Manual 4 Selectronic Australia

Where batteries are joined in parallel, add the capacities together, the voltage will remain the same as each batteries voltage. 2 x 12 Volt 100 Ah batteries connected in parallel would have a capacity of 12 Volts 200 Ah. This would not suit your 24 volt SE10. Only use identical batteries when joining batteries together. How long will my battery last To work out how long your battery will last follow this basic guide. This guide presumes commencing with a fully charged battery. Take the total rating of the appliance being run 1 light globe 25watts 1 20 inch TV 67watts 1 VCR 30watts Total load =122watts Divide this figure (122) by 20 to know the approximate DC current draw =6.1Amps To convert this to Ampere hours, multiply by the number of hours used - Say 1 hour =6.1Ah So if we have a 100Ah battery, then with the above example we should have 100 minus 6.1 = 93.9 Ah remaining in the battery. As a general guide never discharge a battery below 50%. The deeper a battery is discharged on a regular basis, the less life you can expect from the battery. See you battery specifications for full details. SE10 Manual 5 Selectronic Australia

RAPS System Wiring Diagram Generator Solar Panel Wind Generator + Circuit Breaker Junction Box + - Circuit Breaker Regulator + - Circuit Breaker - Battery Charger System Fuse Battery Bank (4 x 6V) Red + Regulator Junction Box Earth Black - SE10 Inverter To electrician s switchboard SE10 Manual 6 Selectronic Australia

System Wiring Your SE10 may form part of a complete power system, If this is the case, the diagram on page 6 may give you a guide. See your designer / installer for full details. Electrician s Note All earth s AC and DC should be bonded An Earth stake should be within 3m of the inverter The SE10 is suitable for connection to MEN wiring Warning As a matter of safety, Selectronic strongly recommend that all fixed installations be designed and installed by appropriately qualified person. The Solar Energy Industries Association in your state or territory can provide names of accredited system designers and installers. The output voltage from an inverter is as lethal as mains electricity. All AC wiring MUST be carried out by an accredited electrician and must conform to AS3000 and/or any relevant local standards. Getting Started Quickly If you want to get powered up quickly here are the 11 simple steps. 1. Familiarise yourself with the details in the first 6 pages on this manual. 2. Unpack the SE10 from the packaging. 3. Check unit for any damage that may have resulted during transport, if any damage is evident report this to your supplier immediately. 4. Make sure the SE10 ON/OFF switch (12) is in the off position. 5. Connect battery positive wire (red) (10) to battery positive or battery fuse. 6. Connect battery neg. wire (black) (11) to battery negative or battery fuse. 7. Plug a 230-240V appliance into inverter front power point (8) but do not switch on. 8. Turn ON/OFF switch (12) to ON. 9. After 3 seconds LED (1) will begin to flash. If no LEDs light, check for correct connection to battery. 10. Turn power point (8) on 11. You re away. SE10 Manual 7 Selectronic Australia

SE10 Parts Identification (9) Heatsinks Battery Negative (black) (11) (12) ON/OFF Switch LED (1) LED (2) LED (3) LED (4) DC Volts >24.0 23.0 22.0 21.0 STATUS AC Volts ON AC Overload DC Volts Low/High TEMP Overload S E L E C T R O N I C S INE WAVE I NVERTER DC TO MAINS POWER SE10 24 VOLT LED (5) LED (6) ON DC Volts ON Low Volts Adjust Power FLASHING Alarms FLASHING Auto Start Adjust 350 WATT CONT 1000 WATT SURGE PROUDLY DESIGNED & MADE IN AUSTRALIA (7) Mode Button (8) Power Point / GPO (10) Battery Positive (red) SE10 Manual 8 Selectronic Australia

Operation Six LEDs are provided on the front panel to indicate a number of parameters, and allow adjustment of some of these parameters. LED (5) and (6) tells you what LED (1) (4) is displaying as indicated on the front panel of the SE10. Pressing Mode Button (7) will change the information being displayed. STATUS indicators LED (5) (green) flashing When power is first applied LED (1) and (5) should flash. When LED (5) (green) is flashing, this indicates the LED (1) (4) is showing the inverters STATSU, as per written notation to the right of the LEDs. In this mode there are no adjustments to be made. LED (1) Flashing indicated the SE10 is in Auto Start mode, this indicates that no power is being drawn from the inverter so it has gone to SLEEP to save power. If no power is used within 12 minutes, the LED (1) will flash at a slower rate therefore saving more power. LED (1) Stays ON, the inverter has been commanded to provide power to the load (e.g. a light switch has been turned on) so it has gone from SLEEP mode to ON. Once the load has been removed (e.g. the light switch is turned off) the inverter will wait 10 seconds and return to SLEEP mode. It is good practice to have your SE10 in SLEEP mode as often as possible. When the SE10 is in SLEEP mode it uses 0.045 amps from the battery, when the inverter is in the ON mode it uses at least 0.3 amps from the battery. The amount of power required to go from SLEEP to ON is adjustable and is described on page 11. SE10 Manual 9 Selectronic Australia

LED (2) AC Overload should normally remain OFF. If the inverter shuts down due to too much AC load being drawn from it then LED (2) will come ON. The SE10 will remain in this condition for 1 minute after the AC load has been decreased to a safe level. If the inverter remains in this condition after one minute, switch (12) should be turned OFF and then back ON. When switch (12) is turned OFF any adjustments made to the factory settings will be lost. LED (3) DC Volts Low / High should normally remain OFF. If the inverter shuts down because the battery volts are too high then this LED (3) will come ON. It will remain ON until normal battery volts are restored. If the inverter shuts down due to not enough battery volts, then LED (3) will flash. LED (3) will continue to flash until the battery volts have risen sufficiently. In this case, charge the battery by starting the vehicle or using a battery charger. The low voltage point that the inverter will cut out is adjustable to suit your particular battery, see page 12 for details of this adjustment. LED (4) Temperature Overload should normally remain OFF. If the inverter shuts down due to internal components getting too hot, then this LED (4) will come ON. It will remain ON until the temperature has lowered to a safe level. The inverter will then come back ON. If this LED (4) is coming on regularly, either reduce the amount of load on the inverter or try to move the inverter to a cooler location. SE10 Manual 10 Selectronic Australia

DC Volts ON, LED (5) (green) ON Pressing the Mode button (7) will change the information being displayed by LEDs (1) (4). Press the Mode button once, the green LED (5) will be ON. This will turn LEDs (1) (4) into a battery voltmeter. The voltage of your battery will be indicated by the figures to the left of LEDS (1) (4). If all LEDs are ON then the battery voltage is greater than 24 Volt. The LEDs will turn OFF one by one as the battery voltage drops. When the battery voltage is below 21 volts, LED (4) will flash. To return to Status, quickly press the mode button (7) once. How to make use of a Voltmeter Batteries vary enormously, in size capacity and quality and can be severely affected by age. By keeping an eye on the voltmeter it will give you a guide to the amount of charge in your battery. Where possible, you should keep your battery volts above 24 volts at all times. If you are using a large load for a short time, the battery volts will probably drop below 24 volts. This is normal and OK as long as the battery volts return to 24 volts when the load is turned off. Auto Start Adjust LED (6) (red) Flashing It is sometimes necessary to adjust the auto start sensitivity to overcome what is called Phantom Loads. A phantom load is a load that tricks the inverter into thinking it should be ON instead of in SLEEP mode. The wiring of a house or a portable stereo system in standby are good examples of a phantom load. These loads serve no purpose but yet can increase battery drain by bringing the inverter ON. Hold the Mode button (7) down until LED (6) begins to flash, (approximately 1 second) indicating you are ready to adjust this setting. The SE10 will leave the factory with a setting of 4 watts. Now press the Mode button (7) until the desired value is sought. LEDs (1) (4) will return to either Status or Voltmeter after 20 seconds. SE10 Manual 11 Selectronic Australia

Indicator LED (1) ON LED (2) ON LED (3) ON LED (4) ON ALL LEDs ON Setting 16 watts 12 watts 8 watts 4 watts Inverter will remain ON at all times. This could be used if a fax machine or VCR is required to stay on at all times. Be aware that this will use more power from your battery. Low Volts Adjust LED (6) (red) ON To avoid total discharging of your battery the SE10 shuts down at a pre-set low voltage. As all batteries are different, so too is the minimum voltage they should be discharged to. The SE10 will leave the factory with a setting of 22.0 volts, change this setting if required. Hold the Mode button (7) down until LED (6) comes ON, (approximately 2 seconds) indicating you are ready to adjust this setting. Now press the Mode button (7) until the desired value is sought. LEDs (1) (4) will return to either Status or Voltmeter after 20 seconds. Indicator LED (1) ON LED (2) ON LED (3) ON LED (4) ON Setting 23.0 volts 22.0 volts 21.0 volts 20.0 volts SE10 Manual 12 Selectronic Australia

Maintenance Inverter Periodic maintenance of your SE10 inverter involves little more than checking for any obstructions to the black cooling heatsink at the rear of the inverter. The heatsink must be cleared of any accumulated foreign matter that may have lodged itself between the fins since the last maintenance check, e.g. insect nests. Also verify that air flow around the inverter has not become restricted. Batteries 1. Every week, carry out a thorough visual inspection of all battery wiring, taking particular note of the condition of inter-connections between cells. This maintenance should be carried out in conjunction with the battery manufacturers recommended maintenance. Safety Hint When working on batteries of such high capacity it is essential that you wear protective clothing, some form of eye protection and rubber-soled work boots. Please regard your batteries with a great deal of caution, and if in any doubt, entrust this work to your supplier / installer. 2. Check that the stainless steel inter-connecting bolts are tight and have no corrosion. If corrosion is evident, carefully follow the following procedure. Disconnect the system battery fuse before working on the battery bank. Unbolt the stainless steel bolts and nuts of any corroded connections and thoroughly clean the joint with a wire brush or file, taking extreme care not to short circuit any battery cells with any tools. Re-assemble and smear a small amount of Vaseline or similar grease over the surface of the joint to slow down any future corrosion. SE10 Manual 13 Selectronic Australia

3. Once a fortnight or as directed in your battery manufacturer, check the specific gravity (SG) of each battery cell using a hydrometer, to ensure that all cells are performing correctly and are properly charged. Any serious imbalance should be reported to your system designer in case remedial action needs to be taken. Solar Modules Periodically check for a build up of dust or any other foreign matter. Wind Generator As wind generators are mechanical devices that are subject to weather variances, proper maintenance is essential for reliable service. Carefully follow the manufacturers maintenance guidelines; if unsure contact your supplier. Handy Hints It is very important that you become familiar with the functioning of your inverter. From a distance, it is not always easy to know what if the inverter is On or in Sleep mode. An easy way to determine this is to plug a small child's night light (neon type) into a power point that is easily visible, or replace this power point with a safety type with a neon indicator. This will indicate the inverter's operation by flashing when the inverter is in SLEEP mode and remaining ON when the inverter is brought ON by a load. SE10 Manual 14 Selectronic Australia

Radio Frequency Interference For many years, Radio Frequency Interference (RFI) has been an annoying problem for owners of Inverters. RFI in a domestic situation can cause noise on an AM radio receiver. The degree of interference can vary dramatically from site to site. Below are a few suggestions to help reduce the effects of RFI in your installation. It is not essential that you follow these guidelines, however, they will give you the best chance of reducing any RFI, particularly on AM radio. It is recommended that the power system including the inverter be housed at least 10 metres from the home. Ensure a good earth stake is placed as close to the inverter as possible. This earth stake should be in a moist area and should be connected to the inverter earth, see page 2 for wiring details. Avoid running DC cables into the home, if at all possible. If this cannot be avoided, run DC and AC in separate conduits separated by as much distance as practicable. All DC wiring should also be kept as short as possible. Connect battery negative to earth. AM radios should be powered from their own self contained batteries and kept as far away as possible from AC or DC wiring within walls. Make sure that your AM radio has maximum signal strength. This will help your radio to reject any unwanted noise being produced by your inverter, regulator, controllers or DC lighting. If possible, try moving the radio around to improve the signal strength or use an external aerial. Some of today's building materials such as steel roofs and foil insulation may form a barrier to incoming radio signals. If an external aerial is required, it should be on the outside of the home, mounted as high as practicable and as far from the inverter as possible. Connection from the aerial to the radio should be via a low loss coaxial cable. Please note the aerial must be an AM RADIO type; a TV aerial will not work. SE10 Manual 15 Selectronic Australia

Fault Finding No indicators ON when power is first applied When first connected, if the SE10 shows no indicators the battery connections may be reversed. Check that the red battery wire (10) is connected to the battery positive, and the black battery wire (11) is connected to the battery negative. Remember there is a 3 second delay before power is available after switch ON. Inverter stays ON when no appliance is being used This can be a common problem known as a Phantom Load, but can be easily overcome. Some appliances will need to be switched off at the power point as they may still represent a small load despite being switched off at the appliance. Check again to make sure that there are no appliances left ON, the sequentially switch off appliances at the wall and by watching your night light (as described in Handy Hint, check to see if the SE10 returns to pulsing (SLEEP) mode after a 10 second delay. Once you have found the offending appliance, increase the sensitivity of the Auto Start (see page 11) until the inverter turns OFF. Once this is done re check that small loads will still bring the inverter ON when required. Inverter shuts down during the middle of the day, and comes back ON late in the afternoon This is more than likely caused by high battery volts during peak charging times from Solar Panels. Battery volts should never exceed 34 volts. If this is the case, have your Solar Regulator checked. Warning As a matter of safety, Selectronic strongly recommend that all fixed installations be designed and installed by appropriately qualified person. The Solar Energy Industries Association in your state or territory can provide names of accredited system designers and installers. The output voltage from an inverter is as lethal as mains electricity. All AC wiring MUST be carried out by an accredited electrician and must conform to AS3000 and/or any relevant local standards. SE10 Manual 16 Selectronic Australia

Product Warranty Conditions Selectronic Australia Pty Ltd warrants your SE10 inverter to be free from defects in materials and workmanship under normal use and service, for an initial period of two (2) years. This warranty is applicable only from the date of original purchase. All parts will be replaced or repaired free of charge within this period. Travelling time for field service personnel is not covered under this warranty. If no authorised field service personnel are available, the unit shall be returned to any authorised service centres, this must be done at the owner s cost. There will be no charge for the return of the inverter. Repairs carried out by unauthorised service centres will not be covered under warranty. In the event of unauthorised exporting, Selectronic reserve the right to refuse warranty claims outside Australia or New Zealand. The provision of this warranty shall not apply if the unit has been subject to misuse, neglect, acts of God, accidental damage or has been used for a purpose for which it is not designed. Charges to the point of purchase and the cost of any repairs resulting from damages occurring during this freighting will be borne by the owner. Any alterations or repairs by unauthorised parties will void your warranty. To ensure fast efficient handling of any warranty claims, please complete and return your reply paid warranty card within 30 days from date of purchase. SE10 Manual 17 Selectronic Australia

SE10 24 Volt Specifications Inverter Type Microprocessor control circuit with PWM full bridge power stage. True sine wave AC output Current draw from Battery Condition Auto Start SLEEP mode (average) Inverter ON, with no Load Maximum Continuous Load (350 Watt) Half hour rating (450 Watt) 5 minute rating (600 Watt) Surge rating (1000 Watt) Amperage 0.045 Amps 0.30 Amps 17.5 Amps 22.5 Amps 30.0 Amps 50 Amps Inverter Power Ratings @ 25º C Condition Continuous Half hour rating 5 minute rating Surge rating (5 seconds) Total Appliance Rating 350 Watt 450 Watt 600 Watt 1000 Watt Auto Start Type Minimum Load to Start Response Time Normal Pulse Mode Power Save Mode Pulsing AC 4 watts 16 watts user adjustable 1 second maximum 1.5 seconds maximum Battery Voltage Range Low DC Volts Cut Out 10 second delay Low DC Volts Cut In High DC Volts Cut Out Instantaneous Voltage 20 23 volts user adjustable 24 volt 34 volts SE10 Manual 18 Selectronic Australia

Inverter Efficiency @ 24 volts 40 watts 75 watts 100 watts 150 watts 260 watts 350 watts 88% efficiency 89% efficiency 91% efficiency 89% efficiency 87% efficiency 84% efficiency Battery Cables Length Diameter Lug 1.6 metres 8mm 2 8mm hole Miscellaneous Specifications Reverse Polarity Protection Output Voltage Accuracy 0-350 watts Output Frequency Total Harmonic Distortion Operating Temperature Range Transformer Type Cooling Method Power Point Weight Shipping Weight Chassis Material Chassis Coating Size Full Electronic Protection ± 4% @ 24 volt input 50Hz ± 0.01% <4% -10º C to 50º C Toroidal Convection 10 Amp Single Pole 4.6 kg 5.2 kg Zinc Coated Steel Powder Coated 176W x 122H x 260mm D SE10 Manual 19 Selectronic Australia

Selectronic Authorised Service Network If service is required, contact your supplier or return your inverter in its original carton with proof of purchase to any of the following service centres. Selectronic Australia Pty Ltd Rainbow Power Company 25 Holloway Drive 1 Alternative Way Bayswater Nimbin Victoria 3153 NSW 2480 Australia Australia Ph: 03 9762 4822 Ph: 02 6689 1430 Fax: 03 9762 9646 Fax: 02 6689 1109 service@selectronic.com.au Burley TV Service Amelec Marine Sales 278 Edmondson Ave. 16 Parkinson Lane Austral O Connor NSW 2171 WA 6163 Australia Australia Ph: 02 9606-0279 Ph: 08 9331 3100 Fax: 08 9331 5150 amelec@tpgi.com.au RF Analysis Reid Technology Ltd Harness Cask Road 3-5 Auburn Street Dorrigo Takapuna NSW 2453 North Shore City Australia Auckland NZ Ph: 02 6657 8003 Ph: 9 489-8100 Fax: 02 6657 8002 Fax: 9 489-8585 ps@reidtechnology.co.nz SE10 Manual 20 Selectronic Australia

Notes: SE10 Manual 21 Selectronic Australia

SELECTRONIC AUSTRALIA 25 Holloway Drive Bayswater, Victoria 3153 Australia Phone 03 9762 4822 Fax03 9762 9646 Email sales@selectronic.com.au Part No ST-M-SE102 REV-3 9/8/2000 SE10 Manual 22 Selectronic Australia