INSTRUCTION MANUAL SHORT BEARING FRAME, STUFFING BOX

Similar documents
INSTRUCTION MANUAL LONG BEARING FRAME, MECHANICAL SEAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HORIZONTAL SPLIT CASING PUMP

Series Base mounted pump. Installation and operating instructions

SERIES PC INSTRUCTION AND OPERATION MANUAL

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODEL 3310

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Series Base mounted pump. Installation and operating instructions

MAINTENANCE AND REPAIR INSTRUCTIONS

SUGGESTED SPECIFICATIONS

WARMAN PUMPS ASSEMBLY, OPERATING AND MAINTENANCE INSTRUCTIONS PART 2C SERIES A SOLUTION PUMPS TYPE S AND SH PC2C

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Dry installed pump type LANDY BTP.

ABS Dry Installed Waste Water Pumps Series FR


DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Routine Compressor Maintenance

INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODELS 3341 AND 3344 END SUCTION PUMPS

The ELM Series Slurry Pump Installation and Operating Manual

APP pump instruction APP and APP 16-22

Starting up hydraulic systems

900 Series Split Case Fire Pump Systems

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING VACUUM PUMPS

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

PROCESS PUMPS (INDIA) PVT LTD

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h. depending of the pump size and material execution

SKF Flex Coupling Installation Instructions

Data sheet. Customer item no.: Communication dated: Number: ES Doc. no.: Item no.: 100 Quantity: 1 Date: 19/03/2015 Page: 1 / 6

Instruction for RBP250-3 and RBP300-3

LUBE FITTINGS Cover halves have 3/8 NPT Iube holes. Use a standard grease gun and Iube fitting as instructed on Page 4.

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Bearings. Shaft seal. Materials

Ni-HARD SUBMERSIBLE PUMP

University of Houston Master Construction Specifications Insert Project Name

APP pump instruction APP 21-43

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

Note: the numbers in parenthesis refer to the components in the exploded view of page 3 for UT-0 thru UT-6.5 and page 4 for UT-7 and UT-8.

Non-clogging Pump DBS TECHNICAL DATA. Output: up to 1200 m 3 /h

S3 General Installation

16000SIII Automatic Grease System

AURORA Series MODEL 3560 ASME/ANSI B73.1M INDUSTRIAL PROCESS PUMPS

Maintenance Instructions

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Contents. Identification

Installation and Operating Manual

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

Ultra Heavy Duty Slurry Pump Ultra Heavy Duty Slurry Pump

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

INSTALLATION AND OPERATIING INSTRUCTIONS FOR R+W FLEXIBLE GEAR COUPLINGS BZ / BZA

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

PROCESS PUMPS (INDIA) PVT LTD

INSTRUCTION MANUAL AC2516 REVISION D INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Series 1580 In-Line Mounted Centrifugal Fire Pumps

Impeller Replacement

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

Model 3550 ASME/ANSI B73.1M Industrial Process Pumps

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

AURORA 3500 SERIES MODEL 3550 ASME/ANSI B73.1 INDUSTRIAL PROCESS PUMPS

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

Technical Documentation Radial Pump with Canned Motor MY-3-MM

Easytork Vane Actuator IOM

Goulds Small Capacity Double Suction Pump

TIN KNOCKER TK H1652 Hydraulic Shear

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

Maintenance Issues for Local Fluid Fertilizer Plants

Crispin Valves Operating Guide. Crispin

DEWATERING PUMP. Instruction, Installation, Operation and Maintenance Manual. A Mark of Quality. ISO 9001 Certified Company

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK

Model SL-12K-A SCISSOR LIFT. wheel alignment model. (11000 LBS / 5000Kg Capacity) INSTALLATION & OPERATION INSTRUCTION (SECOND EDITION)

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

INSTRUCTIONS Installation Operation Repair

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

OPERATION & MAINTENANCE MANUAL FOR NON-CLOG TYPE PUMPS

1) Scheduled maintenance checks

RADEX -N Composite Operating/Assembly instructions

Basic Hydraulic Features. Basic Mechanical Features

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

BOILER FEED SYSTEM OPERATION AND MAINTENANCE MANUAL

SUMMIT PUMP. Model DSR Single Stage, Double Suction Pumps Installation, Operation, and Maintenance Manual

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Elite. KSB Australia Pty Ltd. Centrifugal Pump

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

POMPE AUTOADESCANTI SELF-PRIMING ELECTRO PUMP ACM DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR MULTISTAGE SELF-PRIMING PUMPS

4500C Series Vortex Pumps

GT-200 GATE VALVES PN16, Screwed end

PROJ. NO SECTION HYDRONIC PUMPS

TECHNICAL. AVAILABLE UPON REqUEST CHAPTER CONTENTS. Optical comparator: For process control during serial production.

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

KEEN INDUSTRIAL PUMP CO. Inc.

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

INSTRUCTION MANUAL FOR DODGE GRID-LIGN FLEXIBLE COUPLINGS

Transcription:

Dat: 13.06.00 14.04.00 No: 94-BA 5084E/ 1a TABLE OF CONTENTS Part II 2.0 Type code explanation 2.1 Flushing water connection 2.2 Direction of rotation 2.3 Level control system 2.3.1 Level switches 2.3.2 Level control 2.4 Start-up 2.5 Operating troubles 2.6 Maintenance and service 2.6.1 General 2.6.2 Visual checks of pump unit 2.6.3 Service connections 2.6.4 Sealing systems for soft packed pumps 2.7 Periodic maintenance of stuffing box 2.7.1 Regulation of stuffing box 2.7.2 Replacement of packing 2.7.3 Dimensions 2.7.4 Replacement of shaft sleeve 2.8 Greasing instructions 2.8.1 Bearing lubrication chart 2.8.2 Conversion table 2.9 Alignment and mounting of the pump on base plate 2.9.1 Mounting of base plate

Dat: 14.04.00 14.02.06 No: 94-BA 5084E/ 2b 2.0 TYPE CODE EXPLANATION Hydraulic size Bearing frame size Sealing type Material execution Bearing frame type Seal specification (pumpside) Execution information Basis Executionspecification DDM1W- TT. K S EDS 1W- L S.Q EFM 5W- MM.Q S = Special construction/execution F = for F-Hydraulic K = for K-Hydraulic Q = for Q-Hydraulic. = Filling point M = Standard (for C,G,M,X-seal) T = Special construction/execution (for T-seal) S = Standard for stuffing box bearing frame C = Stuffing box bearing frame with cartridge seal 0 = Without mech. seal (Pos. 515) / without packing (seal / packing specified by customer) C G Pump side mechanical seal specification M (bearing frame with mechanical seal) X T L = Soft packing standard (only bearing frame with stuffing box) W = Short bearing frame 1 = Normal, for hydraulic material 1,2 and 3 5 = Wetted parts stainless steel, for hydraulic mat. 5 S = Bearing frame with stuffing box seal M = Bearing frame with mechanical seal D = smallest size F = larger than D G = larger than F etc. See type code explanation for Hydraulic code

Dat: 14.04.00 14.02.06 No: 94-BA 5084E/ 3b 2.1 FLUSHING WATER CONNECTION Pumps are supplied with a flushing water connection (service connection "F", Fig. 1). For normal sewage application this connection is not used. However, in special cases when pumping high concentrations of sludge or mud, it should be connected. It will conduct cleaning water between impeller and stuffing box seal, providing periodic removal of accumulated solids. Flushing water must be pressure-regulated between 0,5 to 1 bar (7 to 14 psi) above pump discharge pressure. Water is controlled by a solenoid valve on a time clock. Adequate duration of each flushing is 60 seconds; frequently of flushing must be established for each different installation. The quantity of flushing water varies according to pumpsize and application: in most cases, flowrates of 6-8 litres per minute will be sufficient. F Fig. 1 2.2 DIRECTION OF ROTATION Before start up the pump, power connections must be made as indicated in section 2.4. Check that the direction of rotation is correct by giving the unit a starting impulse for one second and noting impeller rotation. Rotation must be counter-clockwise viewed from suction end, and clockwise viewed from driving side. WARNING: If rotation is not correct on multispeed or multi-pump installations, only change the cable leads of the pump or speed with wrong rotation at its starter in the control panel. DO NOT change the primary power leads coming into the control panel: This would change the rotation of all pumps or speeds. direction of free shaft end counter clockwise viewed from suction end Fig. 2 direction of impeller rotation

Dat: 14.04.00 13.06.00 14.02.06 No: 94-BA 5084E/ 4b 2.3 LEVEL CONTROL SYSTEM Prior to any work on the pump, the power supply must be disconnected either by means of a locked isolator or by removing the fuses from the panel. It is not safe enough to switch off the control switch. A wiring mistake or a control system malfuction could put the motor back into operation. 2.3.1 LEVEL SWITCHES - For the on and off levels, use control systems that are appropriate for the pumped liquid. - Use a floating-ball type switch for the high-level alarm, even when there is another type used for the pump control (this has proven to be the most fail-safe type). - The floating ball for the alarm should be placed at a reasonable distance above the highest pump start level to avoid false alarms. 2.3.2 LEVEL CONTROL "ON" and "OFF" levels must be set in such a way as to provide sufficient sump capacity between "ON" and "OFF" so that the pump cannot be switched on more than 10 times per hour. Higher starting frequency may damage the motor control devices in the panel and will cause excessive power consumption. The following formula will calculate the required minimum sump capacity: V = 0.9 x Qp V = sump capacity or volume, between on and off levels (in cubic Z meters) Qp = pump flow for one pump, in litres/second Z = number of starts per hour (Z = 10, maximum) 2.4 START - UP Prior to starting, check that: - Electrical connections of the motor are according to name plate - Level controls are correctly set - Off-level is sufficiently high to prevent air entrance to the pump suction - Suction and discharge gate valves are completely open - Flood pump sump STARTING OF PUMP Never start pump against closed valves (except non-return valves). Start the pump using manual operation. Measure the amperage drawn on each phase leg. Record and verify these readings with the nameplate ratings. If amperage is more than 5 % higher, stop unit and check probable causes according to "Operating Troubles" chart, Section 2.5. Once preliminary checks are complete, place the pump into automatic operation. Cycle the system through several wetwell pumpdowns to observe that level controls are properly set and functioning correctly. Observe that the alarm system and change over switch (if included in control panel) are working properly. Log date and hours meter reading, and set pump for automatic operation. Perform maintenance according to Section 2.6. GENERAL OPERATING CONDITIONS The pump should not be allowed to operate continuous-duty outside of performance curve: high discharge pressures with low flow or low discharge pressure with high flow. Bearing life is shortened and abrasive wear is accelerated in these operating conditions.

Dat: 14.02.06 14.04.00 No: 94-BA 5084E/ 5a 2.5 OPERATING TROUBLES POSSIBLE REASONS TROUBLES No flow Flow not sufficient Head not sufficient Reduction of flow or head after start up Vibrations Motor overloaded Noise Bearing temperature > 90 C 1. Pump not sufficient submerged, not vented X 2. RPM too low X X 3. RPM too high X X X 4. Air entrance into suction line X X X X X 5. Discharge line clogged / valve closed X X X 6. Air or gas in pumped liquid X X X X X X 7. TDH too high (higher than calculated) X X X 8. Suction head too high X X X 9. Insufficient suction head on hot liquids X X X 10. Insufficient submergence of suction X X X X X X 11. Sludge concentration higher than assumed X X X 12. Specific weight of medium higher than assumed X 13. Impeller or suction line clogged X X X 14. Wrong direction of rotation X X X 15. Impeller clearance too high X X 16. Damaged impeller X X X 17. Motor damage X X X 18. Unsuitable lubrication X 19. Attachments loose X X 20. Pump and motor not aligned X X X 21. Bearings worn out X X 22. Impeller out of balance X 23. Impeller too small X 24. Impeller dragging against suction cover X X X 25. Thick sludge and tight impeller clearance X 26. Air or gas on impeller backside X X

Dat: 14.04.00 14.02.06 No: 94-BA 5084E/ 6c 2.6 MAINTENANCE AND SERVICE 2.6.1 GENERAL Before doing any work on the pump unit, switch off main isolator switch and remove fuses from panel. The following checks can be done in the field. When a repair is indicated, send the pump unit to the nearest authorized Hidrostal service station. 2.6.2 VISUAL CHECKS OF PUMP UNIT - Check pump and motor for possible mechanical damage. - If pump volume or pressure are not acceptable, check impeller clearance (see manual for hydraulic). - Check overload relay, fuses and time relays (if any) for correct setting. - Check correct function of level control. - Check alignment of coupling according Section 2.9. 2.6.3 SERVICE CONNECTIONS The service connections that are built into all pumps as standard are listed below. Please refer to Fig. 3 and sectional drawings. 552a/552b Flushing Connection "F1" and "F2" Alternatively or even in addition to the function described in Section 2.1, this connection may be used to manually bleed the air from the casing prior to start-up, if there is no other place for air to escape through the discharge piping. In most cases the connection 552b will be closed and flushing water mixes with product pumped. In cases where the solids accumulate, could form lumps, or be fibrous flushing out via 552b would be the preferred solution. Connection 552b also permits complete draining of product from horizontal bearing frames if required. 131 Greasing point "G1" Greasing instructions see Section 2.8. 134 Plug "G.O." Possibility to remove old, excessive grease. 222 Packing flushing connection "Q" See Section 2.6.4.

Dat: 03.10.03 14.04.00 No: 94-BA 5084E/ 7c Fig. 3 2.6.4 SEALING SYSTEMS FOR SOFT PACKED PUMPS GENERAL All pumps factory supplied with a soft packed stuffing box are packed in accordance with Fig. 3. Four flushing/packing lubrication systems are available and may be specified to best suit the pumping application. See Fig. 4-7 and Section 2.1 Flushing water connection. Flushing liquids should be at a pressure of approximately 0.5-1 bar (7-14 psi) above that of the pumps working pressure. It is recommended that a flow restrictor be fitted to the flushing line to prevent excessive flow of sealing liquid, generally, approximately 6-8 litres per hour will be adequate for most applications.

Dat: 14.04.00 14.02.06 No: 94-BA 5084E/ 8b SYSTEM 1 (Fig. 4) This is recommended when pumping biological sludges where due to the consistency and nature of the sludge no flushing is necessary. SYSTEM 2 (Fig. 5) Recommended for general dirty liquids, mud and raw or digested sludge applications. The flushing liquid is piped through connection No. 1 on the pump back cover to the lantern ring thereby inhibiting the entrance of abrasive material into the packing chamber so reducing wear. This connection can also be used to install a vacuum pump. SYSTEM 3 (Fig. 6) Recommended when pumping raw sewage. A water repellent grease is supplied by a grease lubricator at the packing chamber through connection No. 1 so both preventing the penetration of solids and helping to lubricate the packing so reducing wear. Note: NEVER use spring- or other type of automatic greaser. SYSTEM 4 (Fig. 7) This plan connection No. 2 on the pump back cover is used to flush the cavity between the impeller and the back cover free from any accumulating solids. Especially recommended when pumping highly concentrated paper pulp, sludge or mud where due to the degree of concentration there may be a tendency to dehydrate or sedimentate. E.g.: If the pump should be used in a vertical position on materials having a natural tendency to gasify connection No. 2 may also be used to bleed the pump on plant start-up. 2.7 PERIODIC MAINTENANCE OF STUFFING BOX 2.7.1 REGULATION OF STUFFING BOX The stuffing box should be adjusted to permit a constant dripping, to insure continuous lubrication and cooling to the stuffing box assembly. Excessive adjustment will cause the packing (215) and shaft sleeve (208) to wear. When adjusting the stuffing box gland bolts (220), insure that left and right bolts are uniformly tightened. Once the stuffing box gland (202) has reached maximum adjustment, do not add packing rings to the gland. Replace the packing rings (215) in accordance with following section.

Dat: 14.04.00 13.06.00 No: 94-BA 5084E/ 9a 2.7.2 REPLACEMENT OF PACKING Once the stuffing box gland (202) has reached maximum adjustment, it is required to revise all packing rings (215). By replacing only one packing ring to the stuffing box, the lantern ring will be pushed towards the pump housing causing higher flow of sealing liquid to the pump, reducing the sealing effect of the front packing rings. In most cases the packing rings nearest the impeller will be worn out. Proceed as follows by referring to Fig. 8 to 12. 1. Disconnect power to the driver, close suction and discharge valves, isolate external service connection to stuffing box seal plate or back cover (200) and drain pump. 2. Remove stuffing box gland bolts (220) and washers (229), slide stuffing box gland (202) towards bearing frame. Gland to be split and taken away from shaft by removing screws (223). Use an extractor (Fig. 9) to remove the upper packing rings. Remove nuts (221), pull stuffing box casing (201) and lantern ring (204) towards bearing housing. Use an extractor (Fig. 9) to remove the lower packing rings. Inspect the shaft sleeve (208), stuffing box casing (201) and seal plate or back cover (200). Excessive wear of shaft sleeve (208) can cause higher leakage of the stuffing box. Replacement of shaft sleeve (208) see section 2.7.4. Should the packing be worn out, replace according to paragraphs 3 to 4. Clean the shaft sleeve (208), lantern ring (204), stuffing box gland (202) and coat with water repellent grease. 3. Prepare the packing rings by quantity and size (see Section 2.7.3 Dimensions). If packing rings are cut from a coil or long length, wrap the packing around a sleeve of the diameter of the shaft sleeve (208) and cut tangentially as shown in Fig. 10. An overlapping split of the packing rings provides better sealing, refer to Fig. 11. Do not cut ends straight on a flat strip, as the packing rings would never seal (Fig. 12). 4. Using the lantern ring (204), tamp in the lower packing rings (215) towards the impeller and alternate joints 90 apart. Align lantern ring (204) with the seal water admission port. Fitting stuffing box casing (201) to seal plate or back cover (200) by tightening nuts (221). Using the stuffing box gland (202), tamp in the upper packing rings alternating joints 90 apart. Install stuffing box gland bolts (220) with washers and adjust to finger tight. Place into operation according to these instructions. Adjust every 10 minutes until normal operation has been reestablished. 2.7.3 DIMENSIONS Fig. 8

Dat: 14.04.00 14.02.01 No: 94-BA 5084E/ 10a Bearing frame Cone size A B C D E F packing rings tool for nut (205) type quant. length Fig. SW S P Torque mm mm mm mm mm mm pcs. mm No. mm mm mm Nm DDS.W 1 1/2" 70 1 12 10 69 50 5 198 46 - - EDS.W 13 FFS.W 2" 86 1 15 12 95 70 5 260 65 - - 160 HFS.W EGS.W 2" FGS.W 2 1/2" HHS.W 3" IIS.W LIS.W ILS.W LLS.W MLS.W 100 mm 5 14-119 8 900 Fig. 10 Fig. 9 Fig. 11 Fig. 12 Fig. 13 spanner 2.7.4 REPLACEMENT OF SHAFT SLEEVE (208) Fig. 14, "C" spanner AMF DIN 18108 with round spigot Excessive wear of shaft sleeve can cause higher leakage of stuffing box. Once, if sleeve has to be replaced, proceed as follows by referring to Fig. 8/13/14. Remove nut (205) with required tool according to table of Section 2.7.3 Dimension. Loosen and remove shaft sleeve from conical seat of shaft (110) by giving soft strokes to sleeve nearest impeller cone using a soft mallet. Remove, clean and inspect sealing ring (144) and spacer ring (145) for damage. If necessary, replace sealing ring (144). Clean shaft and new shaft sleeve. To check mounting length of sealing ring (144), first push sleeve without O-ring (216) onto shaft. Sealing ring (144) should be compressed between 0.3-0.8 mm. If this is not possible, change spacer ring (145) until correct mounting length has been achieved. Now place sealing ring (144) onto shaft and O-ring (216) into groove of shaft sleeve. O-ring (216) and shaft to be lubricated with seal grease for easy assembly. Conical seats of sleeve to be oil lubricated. Push shaft sleeve onto shaft to correct seat. Fasten nut (205) to the shaft with required torque according to table of Section 2.7.3 Dimension.

Dat: 14.04.00 28.03.06 No: 94-BA 5084E/ 11c 2.8 GREASING INSTRUCTIONS For greasing intervals and amounts see bearing lubrication chart (Section 2.8.1). For regreasing bearing frames, we recommend grease according to following specifications (from KLÜBER LUBRICATION): FOR BEARING FRAME TYPE:. DS. W -. IS. W. LS. W +. MS. W BEARING GREASE: STABURAGS ISOFLEX TOPAS NBU 8 EP NB 52 Mineral-oil based, Synthetic oil based, Barium-complex Barium - complex as thickener. as thickener. Typical characteristics: Colour: beige beige Apparent dynamic viscosity (approx.): 6000 mpas 5000 mpas Operating temperature range: -30.. +150 C -60.. +160 C Consistency class (NLGI) 2 2 Penetration DIN ISO 2137 (0.1 mm): 280 280 Dropping point DIN ISO 2176: > 220 C > 240 C Corrosion protection DIN 51802: 0 0 / 1 RPM - parameter (n x d m ): 500 000 1 000 000 Greasing amount: Overgreasing can cause excessive operating temperature and premature bearing failure. Greasing intervals can be used for Horizontal Installation. They should be halved for Vertical Installation or if the following conditions apply: High humidity or contamination, ambient temperature of more than 40 C or with increased loads which could influence the Bearings. With greasing intervals of more than 12 months (1 year) pump must be regreased at that time. Regreasing (whole operation can be done whilst pump is running; see Fig. G.O.): Remove plug 134 to drain old grease. Remove plug 131 (if available; see section 2.6.3; Service connections). Put fresh grease (with suitable device) into greasing connection 131, take care to avoid contamination. When regreasing is finished, greasing connection 131 and grease relief connection 134 to be closed again with plug. Example to read bearing lubrication chart 2.8.1 (the fields in the table are marked grey): Bearing frame type DDS1W with a shaft speed of 1500 rpm has a greasing interval of 8500 hours and needs a grease amount of 28 grams. Converting the greasing interval from hours to months see table 2.8.2. It means for our example: For an assumed running time of the pump of 18 hrs. / day, it gives an equivalent greasing interval of 12 months. HIDROSTAL AG recommends continious regreasing with an automatic, electronic grease dispenser and offers such a product for sale. These can be connected to the potential free contact within the starter contactor by extending the included contact wire. With this it is guaranteed that pump is greased only during running time (if needed). Overgreasing is not possible. Grease dispensers are factory refillable. If lubricators are ordered from the factory, please indicate correct bearing frame type Parts identification : 8SB - 125STABU or 8SB - 125ISOFLEX Content approx. : 120 gramms Running time : 2 weeks to 18 months Fig. G.O. For description, installation and operation of this grease dispenser see seperate instruction manual.

Dat: 14.04.00 14.02.06 No: 94-BA 5084E/ 12a 2.8.1 BEARING LUBRICATION CHART CONNECTION 131 Bearing frame size DDS. W EDS. W FFS. W HFS. W Shaft speed rpm Interval hours Amount of grease grams Bearing frame size Shaft speed rpm Interval hours Amount of grease grams Bearing frame size Shaft speed rpm Interval hours 4800 2200 3000 2000 1700 2500 4200 3000 1800 5000 1500 3000 3600 3500 1500 5500 1200 4000 EGS. W 3000 5000 1200 7000 60 IIS. W 1000 5000 FGS. W 1800 7500 1000 8000 900 5500 28 LIS. W 1500 8500 900 8500 750 6000 1200 9500 750 9500 600 7500 1000 10500 1800 3500 500 8000 900 11000 1500 5000 1500 1500 750 12000 1200 5500 1200 2000 3500 2000 HHS. W 1000 7000 90 ILS. W 1000 2500 3000 3000 900 7500 LLS. W 900 3000 1800 5500 750 8500 MLS. W 750 3500 1500 6500 600 9500 600 5000 48 1200 8000 500 6000 1000 9000 900 9500 750 10000 Amount of grease grams 120 160 2.8.2 CONVERSION TABLE With conversion table right, greasing intervall from table 2.8.1 can be converted from hours to months. Greasing interval hours 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000 Running time in hours per day 0-2 2-6 6-12 12-18 18-24 Equivalent greasing interval in months 11 6 4 3 12 7 5 3.5 8 6 4 10 6.5 5 11 7 5.5 12 8 6.5 9 7 10 7.5 8500 More than 12 months (1 year) 9000 10000 11000 12000 13000 11 8 12 9 9.5 10 11 12

Dat: 14.02.06 14.04.00 No: 94-BA 5084E/ 13b 2.9 ALIGNMENT AND MOUNTING OF THE PUMP ON BASE PLATE The motor, if supplied, is correctly aligned on the baseplate at the factory. However, a certain amount of misalignment is possible during transit, and it is therefore necessary to check the alignment between the pump and the driver before putting the unit in operation. The pump shaft should be checked for angular and for parallel alignment (Fig. 15). Inaccurate alignment results in vibration and excessive wear on bearings and mechanical seals. The check for angular alignment must be made by inserting a taper gauge at four points 90 apart, between the coupling faces. The variance in readings must not exceed 0,3 mm. To check for parallel alignment, place a straight edge across the coupling rim at the top, bottom and sides. The unit will be in parallel alignment when a straight edge rests evenly on the coupling rim at all positions. 2.9.1 MOUNTING OF BASE PLATE The permissible ground load has to be compared with the total weight of the pump. The concrete foundation must correspond to the guidelines of the strength of foundation and the resistance to pressure. Foundation screws: HIDROSTAL AG recommends the use of chemical anchor screws which are secured with a 2-part Epoxy resin. Align pump and base plate horizontally and check the correct position! ATTENTION: The base plate has to be supported on all 4 edges. If necessary, differences of dimension could be compensated by 2 part flow concrete epoxy resin (self leveling epoxy grout)! Mark and drill the holes for the foundation screws. Place the foundation screws. Pay attention to the correct length of the threaded rod. Allow the required length of time for the epoxy to harden! Screw down the base plate. ATTENTION: Tighten the foundation screws with the prescribed torque according to specifications of producers! Check this torque during operation occasionally! Fig. 15