FES1800EK. Electronic Plumbed-In Fire Extinguisher System Installation Instructions

Similar documents
FESG1500R Remote Electronic Plumbed-In Fire Extinguisher System Installation Instructions

FX G-TEC 2900R Advanced Discharge System (Long Cylinder) FX G-TEC 2900R-D Advanced Discharge System (Dumpy Cylinder)

FX G-TEC 3300R Advanced Discharge System (Long Cylinder) FX G-TEC 3300R-D Advanced Discharge System (Dumpy Cylinder)

FX G-TEC 3300R Advanced Discharge System (Long Cylinder) FX G-TEC 3300R-D Advanced Discharge System (Dumpy Cylinder)

2 Engine Nozzles, 1 cockpit nozzle. FX G-TEC 2900R3 FIA standard Advanced 8865 Discharge System

FIA & MSA Approved Systems FITTING INSTRUCTIONS PLEASE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR SYSTEM. Inst/Z2000/All/V1/Oct05 1

Technical Bulletin 036 Zero FM m 3 & m 3 Installation Guide

FITTING INSTRUCTIONS

FITTING INSTRUCTIONS

Technical Bulletin 016 Zero Installation Guide

URGENT: Fire Extinguisher Valve Co. Ltd (FEV) - safe emptying procedure of cylinders

URGENT: Fire Extinguisher Valve Co. Ltd (FEV) recall of cylinders

FEDERATION INTERNATIONALE DE L AUTOMOBILE

Technical Bulletin 012 Zero 2000 MSA & FIA Kit Content and Spares

r i g b y t a y l o r Freefone igo Linemarking machine PARTS LIST

Additional top escutcheon plates with additional inscription to be clipped on the escutcheons and padlock devices

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Technical Data. 13 Amp Fused Connection Units

NEW 500 TRAILER, The leading sewer cleaning machine for. professionals. The new ROM 500 trailer

Thank you for purchasing an SPA Extreme SFI system IMPORTANT NOTE

Technical Bulletin 041 FIA TL 16 Kit Content and Spares

MSA Junior Rallycross Championship. Technical Regulations

SIGNAL HEADS. The LED signal indication must operate on a nominal 120 VAC power source.

GD 1000 series. Made for ADVANCE 1/99 FORM NUMBER

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

123 Industrial Loop Road Paynesville, MN Phone:

Save space.cut costs. Broaden your network. AccessNET

It should be used in conjunction with the full Vortex thread entitled

NEW ROM 900 TRAILER, The sewer cleaning machine for professionals. The new ROM 900 trailer

Technical Data. 45 Amp Switches. Brief product description: Features:

Low Pressure Air Spraying Equipment. FineCoat Outstanding Spray Pattern. Light and Compact. Extremely Quiet

Congratulations on purchasing the epump solar pumping solution.

VAD Variable Area Desuperheaters

ALWAYS follow all Webasto installation and repair instructions and observe all warning instructions.

CHERY P Wiring Description Fitting Instructions Tools Required Calibration

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

INSTALLATION MANUAL - v4

Acura TMV3 Bath Filler AC50010CP and AC50020CP

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

For cleaning machines, parts & supplies click/visit This parts list is for machines after seiral number

Lotus Price list switzerland

2018 Lebanese Drift Championship Technical Regulations

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

INSTALLATION AND USER MANUAL

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap

2018 Technical Regulation for Indian Touring Cars (TC-1)

GROUP E EXPLODED VIEW: EV FUEL SYSTEM 2.4L G2 DRAWING #: 0G1151 ITEM PART# QTY. DESCRIPTION

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Z-Ion Installation and Retrofit Instructions

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

LED PICTURE FRAME KIT

Evensprey 300 Machine Assembly

Zip FlushMaster Surface mounted sensor

INSTALLATION INSTRUCTIONS FOR PART #48003 WATER/METHANOL INJECTION SYSTEM 6.6L Duramax Diesel

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

2003 Dodge or Ram Truck RAM 2500 Truck 4WD L6 5.9L DSL Turbo VIN 6

Manifold QF. Contents. Description. Installation & Setup Guide. Safety 3. Introduction 3. Installation Standards 4. Specifications 5.

High Pressure Rotating Arch Parts List Jan. 12, 2017 Rev. A

Data Sheet 3.11 Issue F

Online Capacity Tester MK70 User and PC-Software Manual

CANADA CATTRON RCLS Special Instructions

Data Sheet 3.03 Issue D

DFS Dynamic Fuel Systems Inc.

ruise otor Installed weight of the cruise control is approximately 2.0kg.

JABSCO & Series 1½ 80 SIZE UTILITY Pump

Parts Manual FRONT-FOLD BOOMS MODELS 80, 90 & 100 HYDRAULIC FOR TA1200 & TA1600 SPRAYERS. Serial Number B & Higher. Part No.

GLM SERIES CONTROL Users Manual Rev:

Data Sheet 3.01 Issue C

DRAFT Technical Regulations for Trucks result of La Paz/Breda TWG V

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

**Product Disclaimer**

A WORD ABOUT PROPER GROUNDING

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

Electric Life JE18-KIT 2007 and up Jeep Wrangler 4 door Installation Instructions

8 PARTS MANUAL 8.1 LIFT ASSEMBLY

part three electrical installations

MERLIN L SEALER SPARES MANUAL MACHINE NO.FG480

Battery Control Center - Diesel

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

Installation of Triple A-Pillar Pod and 7 Series Diesel Gauges Dodge Ram w/ 12 Valve Cummins Diesel Engine

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

ARB TACOMA COMBO BULL BAR 2005 ONWARDS. WARNING

INSTALLATION and OPERATION MANUAL

PA 52 HY REACH. Mk2 Models. Parts Manual. Publication 490 October 2005 Part No Revision:

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

ELECTRICALLY HEATED SYSTEMS


Fuse holders and fuses

PARTS LIST FOR HDS SERIES (AFTER SERIAL # and # )

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

ipro -90 Plasma Extension Gun Plasma Spraying Parts List PL EN 04

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

CHECKING THE ELECTRONIC FUEL INJECTION SYSTEM.

Installation and Operating Guidelines Battery Back-up Pump System

MINI-EDGER POLISHER/SCRUBBER

AUTO TEST. Observed Section Trials (OST) OST FORMULA

PORTABLE ELECTRICAL EQUIPMENT SAFE OPERATING PROCEDURE

RALLYSAFE RALLY CAR FITTING KIT MANUAL

Transcription:

FESG1800E Electronic Plumbed-In Fire Extinguisher System Installation Instructions This is an FX G-TEC 1800E +ADS Advanced Discharge System - homologated gas fire extinguisher system. To maintain optimum performance all systems should be serviced every two years. IMPORTANT Please read the following before commencing any installation. 1. The control box does not contain a battery; you will need to supply a 9-volt PP3 battery. 2. Do not plug the loom into the Firing Head until the firing button connections are made. 3. Do not arm your system until you have completed the battery and circuit test as indicated on the control box instructions supplied with the control box. KIT CONTENTS Qty Description Drawing Item No Part No 1 Cylinder 1 CYL-IX00-E 1 6mm Tubing 5mtr 8 FE-DECA-6 2 Cockpit Nozzle Colour Code (Silver) 9 FE-NOZ-TWIN 2 Engine Nozzle 10 FE-NOZ-X 1 External Firing Button 11 FES-EXT-FB 1 Control Box 12 FES-FC-BOX 1 Internal Firing Button 13 FES-INT-FB 3 Tee Connector 6-6 15 FE-T-CON-6-6 1 Y Connector 6-6 Optional 16 FE-Y-CON-6-6 8 Tube clips 1 E Label INSTALLATION INSTRUCTIONS 1. BOLT the cylinder-mounting cradle to the vehicle structure SECURELY. 2. Mount the electronic control box in a suitable location. 3. Mount the firing switches to enable operation in accordance with current regulations. One inside the vehicle within easy reach of the driver (and co-driver where applicable) (18.75mm diameter hole) and one on an outside panel (22.5mm diameter hole) adjacent to the electrical cut out switch. Apply the E Decal label adjacent to the external firing switch. 4. WIRING. Wiring harness has 2-paired cables with bared ends. (A) Firing switches 1 & 2 are connected to the black pairs of wires. Install 9V PP3 type dry battery into control box (note battery is not supplied). 5. PLUMBING - IMPORTANT Please note 6mm piping supplied fits into various fittings in accordance with assembly drawing no FX G-TEC IX00E ensure that all push in connections are secure. Note that the supply from the firing head should enter the centre branch of the T connector and exit the two outlets of the T connector into nozzles and two cockpit nozzles. FES1800EK 1

Engine Nozzles should be positioned to enable the spray cone to cover areas at most risk, for example the engine fuel system and turbo. If in doubt ask your local MSA/FIA scrutineer to advise. Hole size for nozzle 12.5mm Diameter. Cockpit Nozzles as Homologated Mount two cockpit nozzles on the front door pillars pointing horizontally towards the centre of the car, just below the bottom line of the dashboard. Each nozzle has two colour coded jets (silver), angle each nozzle at 45, one jet pointing horizontally across the car towards the centre, the other jet point into the footwell at 45 to the horizontal. Hole size for nozzle 13.5mm Diameter. Nozzle position THIS IS A SAFETY ITEM! CHECK YOUR INSTALLATION CAREFULLY! IF IN DOUBT ASK! Please Note: FEV FX G-TEC systems are tested and rated for a temperature operation range of 10 to +60 degrees C in accordance with FIA regulations. Users should ensure that where high temperatures are anticipated adequate provision is made to locate the system away from high temperature sources (exhaust, catalyst, etc) and if necessary fit reflective insulation around the cylinder. BEFORE EVERY EVENT CHECK SYSTEM CONTENTS, NOZZLES ARE CLEAN AND ALL CONNECTIONS ARE SECURE FES1800EK 2

FES1800EK 3

F.E.V. CONTROL BOX INSTRUCTIONS The Control Box is supplied with 3 cables. One of these is terminated with a 3-pin plug for connection to the Remote Gas Charge Cartridge on remote systems or the Firing Head on pressurised systems. The other 2 cables are not terminated and are for connection to the External and Internal Control Button Switches. Either cable can be connected to either type of switch. Setting Up The System On the control box a 3-position switch selects the function with centre being OFF. The up position is TEST and down position ARM. Switch to the test position. Observe that the GREEN LED comes ON for about 1 second and then goes OFF. This signifies a good battery, if the GREEN LED fails to come ON then the PP3 battery must be exchanged for a new one. At the same time the YELLOW LED should be ON. If the FIRE BUTTON is now pressed the yellow led will go OFF signifying a good circuit. Switch To The Armed Position In the armed position and if the system is ready then the RED LED will be ON. If either the wiring or firing detonator is faulty or the detonator is either not there or has already fired, then the LED will not light. There are two 1.2 Metre wires coming from the unit, either or both should be connected to firing push button switches of the users choice. Making the circuit between the two wires, coloured red and blue WILL cause the extinguisher to FIRE. Plug for Remote FEV Circuit Test 1 sec BAT Test OFF ARMED if ON Wires for Two Fire! Buttons Fit a single pole push button on each Red wire, (Red and Blue conductors). Blue Push to FIRE! If only one button is required then cut back and ensure red and blue FES1800EK conductors are isolated 4

FES1800EK 5