UniSec Maintenance solutions

Similar documents
Low and medium voltage service. Power Care Customer Support Agreements

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

MCset kv Medium voltage equipment

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

UniSec Operation and maintenance manual

ZX2.2 Gas-insulated medium voltage switchgear

NXPLUS C Single busbar. Maintenance-free for lifetime

Life cycle services for protection and control relays Full support from start to finish

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

2018 Life Cycle Management. ABB Italy medium voltage products for marine application

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Air-insulated switchgear UniGear type ZS1

VD4/R - VD4/L - VD4/UniAir - VD4/UniMix

Gas Insulated Metal-clad Switchgear, HMGS!

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Ultra Fast Earthing Switch UFES retrofit Overview

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

ZX2 Gas-insulated medium voltage switchgear

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

UniGear. Technical Guide

EMPAC Metal enclosed capacitor bank for wind applications

Alvin Xu & Johnny Wang, ABB Xiamen Switchgear Co,. Ltd., November, 2016 ABB lead the intelligent revolution Intelligent technology (Part 2)

1. Safety practices General Introduction Standards...3

8DJ. Maintenance-free for lifetime

Switchgear and Distribution Systems for Engineers and Technicians

Medium Voltage Distribution Maintenance Guide I 2013 Premset. 15 kv compact modular vacuum switchgear with Shielded Solid Insulation System

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

For your safety! Foreword

SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE

ZX-Family Gas-insulated medium voltage switchgear

ABB Wind Care Service Offering

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

In any of the 5 star hotels. The exact venue will be informed once finalized.

Outdoor vacuum breaker for railway applications - FSK II

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

Air-insulated medium-voltage secondary distribution switchgear

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

EISHO TEK. Vacuum Circuit Breaker

Product Specification

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Power Products Division. Power Services Service underpins everything we do

VD4 Installation and service instructions kv A ka

voltage switchgear ZX ABB ZX Family 1

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

PATENT PENDING. Phone: (877) Operation and Service Manual

Case Study on On EHV Circuit Breaker Flashover NTPC-SINGRAULI

PowerCube type PB. Pre-assembled modules and enclosures for constructing medium voltage switchgear

VD4. Installation and service instructions kv A ka

Medium voltage indoor circuit breakers ANSI/IEC solutions

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

UniSec licensed by ABB, produced by Metix WHERE ENERGY LIVES COMPLETE SOLUTIONS

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Vacuum Circuit Breaker VS1

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

ABB Services for Low Voltage equipment Your choice, your future

HD4-LMT. MV SF6 Circuit Breaker Installation and Service Instructions kv 1,250 A 31.5 ka

Instruction manual. EK6 Earthing switch 36/40.5 kv

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

Circuit breaker interlocking and operation requirements SIEMENS

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Metal Clad Air Insulated Switchgear

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

PowerCube type PB series A complete solution for OEMs

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Appendix: Safety and application notes for... 15

Medium voltage vacuum circuit breaker. E-VAC series

33KV INDOOR SWITCHGEAR

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

User manual W-VACi. W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

B kv T&D GAS INSULATED SWITCHGEAR

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

LEAP - Life Expectancy Analysis Program For Electrical Rotating Machines. Marcio Gennari ABB Brazil Automation Products Machines Service Osasco

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

Transcription:

DISTRIBUTION SOLUTIONS UniSec Maintenance solutions ABB supports you to improve the reliability, safety and efficiency of your electrical equipment UniSec Maintenance solutions

Table of contents 004 00 UniSec maintenance solutions 006 007 Condition-based maintenance using MySiteCare 008 010 Traditional preventive maintenance 011 Spare parts

4 UNISEC - MAINTENANCE MANUAL UniSec maintenance solutions The ABB Medium Voltage Service offers long-term systematic and organized maintenance and support for your production, including recommendations for preventive maintenance and spare part programs. Our preventive approach helps to eliminate many of the potential problems while reducing the risk of equipment failures and unscheduled repairs. ABB maintenance services always include repairs authorized by the manufacturer and refurbishment of equipment so that it corresponds to the original product. ABB proposes risk and conditionbased maintenance strategies to ensure maximum plant reliability. Corrective maintenance Maintenance performed after a fault has been detected for the purpose of restoring the normal operating conditions. This approach is based on the firm belief that the costs sustained for downtime and repairing faults are lower than the investment required for a maintenance program. This strategy may be cost-effective until catastrophic faults occur. Preventive maintenance Maintenance performed at predetermined intervals or according to prescribed criteria for the purpose of reducing the risk of failure or impaired performance of the equipment. This method is based on scheduled maintenance activities to which the out-of-service apparatus is subjected, including: visual inspections, cleaning, lubrication of mechanical components, replacement of worn parts and routine tests. The maintenance cycles are planned for when the apparatus must be taken out of service. This method reduces the incidence of operating faults.

DISTRIBUTION SOLUTIONS Performance and reliability Upgrade or retrofit solution Risk and condition/ based maintenance Repair No maintenance Time Switchgear operating trend over time based on the adopted maintenance strategy. Risk-based maintenance Method which includes analysis, measurement and periodic tests in addition to standard preventive maintenance. The acquired information is evaluated on the basis of the environmental, operating and process conditions of the equipment in the system. The aim is to perform asset condition and risk assessment enabling the appropriate maintenance program to be defined. All equipment with abnormal values is refurbished or replaced. This allows the useful life of the plant to be extended and guarantees high levels of reliability, safety and efficiency over time. Condition-based maintenance Maintenance based on monitoring the performance of the apparatus and controlling the corrective measures adopted as a result. The effective condition of the equipment is assessed by online monitoring of significant operating parameters and their automatic comparison with average values and performance. Maintenance is performed when certain indicators signal that the equipment is deteriorating and the likelihood of failure is increasing. In the long-term, this strategy allows maintenance costs to be drastically reduced, thereby minimizing the occurrence of serious faults and optimizing the way the available economic resources are used.

6 UNISEC - MAINTENANCE MANUAL Condition-based maintenance using MySiteCare MySiteCare The MySiteCare monitoring and diagnostics unit employs various sensors to acquire circuit breaker and switchgear data, after which it converts these data into diagnostic information so as to assess the conditions of the apparatus and allow maintenance work to be planned. One MySiteCare unit must be installed for each circuit breaker or switchgear panel. MySiteCare monitors the following variables: Operation of the mechanical part: opening and closing times, spring loading time, slipping and failed spring loading attempts, number of operations, idle time Contact wear and remaining life estimation SF 6 circuit breaker pressure, protection relay watchdog and control coil continuity state can also be monitored by MySiteCare. MySiteCare implements predictive diagnostic algorithms and provides indications concerning the mechanical, electrical and operating conditions of the circuit breaker or panel. MySiteCare has a user friendly interface that displays information by means of a traffic light: red, yellow and green. This signal indicates how serious the problem is, thus the probability of failure or impaired reliability and safety of the monitored equipment.

DISTRIBUTION SOLUTIONS 7 A - Central unit This is the monitoring and diagnostic part. It provides a set of binary inputs which monitor circuit breaker operation and timing, including trip and closing coil activation, auxiliary contact, springs loaded signal. It can also monitor other parameters, such as SF 6 circuit breaker pressure, protection relay watchdog and control coil continuity state. A B B - Current sensors for contact wear estimation Hall-effect current sensors clipped onto the secondary circuits of the current transformer inside the auxiliary compartment. They measure the threephase currents to estimate circuit breaker pole contact wear and the mechanical and/or electrical wear-out of the spring-loading gear motor. C - RFID identification sensor Based on RFID wireless technology, this sensor identifies and traces breaker replacement in the switchgear or breakers swapped between panels. It also measures the temperature in the breaker compartment. C

8 UNISEC - MAINTENANCE MANUAL Traditional preventive maintenance Alternatively, regular check-ups are required to maintain the original performance level of the equipment. To ensure it is performed correctly, maintenance must be carried out by skilled personnel, familiar with the characteristics of the switchgear and with in-depth knowledge of the apparatus. Maintenance activities must be performed in compliance with all the relevant IEC safety regulations, with those of other technical authorities and with the regulations in force in the country where the switchgear is installed. Compliance with any additional instructions of primary importance is also mandatory. We advise you to call in the ABB Service personnel when maintenance and repair work are required. The switchgear is designed for use in normal service conditions, as defined by standard IEC 62271-1 (Table 1). The effects of the reduced dielectric strength of the insulating air must be taken into account at site altitudes above 1000 m (please refer to standard IEC 61271-1). Compensate for increased ambient temperatures when busbars, branch conductors and other components are designed, otherwise the current carrying capacity will be limited. Condensation may form when the switchgear operates in areas with a high degree of humidity and/or major temperature fluctuations and must remain an exception in normal service conditions for indoor switchgear. Preventive measures (e.g. installation of electric heaters) must be discussed with the manufacturer so as to avoid the phenomenon and any resulting corrosion or other adverse effects. Consult the dedicated product manuals as indicated in table 2 for detailed information and specific maintenance procedures ensuring that the tasks are performed in safe conditions. Table 1 Ambient air temperature C Maximum + 40 Maximum 24 h average + 3 Minimum 24 h average - ( 1 ) Minimum recommended + Altitude above sea level Maximum 1000 Humidity conditions % Average value of relative humidity (24 h) 9 Average value of relative humidity (1 month) 90 Pollution The ambient air must not be significantly polluted by dust, smoke corrosive and/or flammable gases, vapours or salt. ( 1 ) Contact ABB for - 2 C operating temperatures and - 40 C storage temperatures Table 2 Vacuum circuit breaker: VD4/R type Vacuum circuit breaker: Vmax type Vacuum circuit breaker: VD4 type SF 6 circuit breaker: HD4/R type Vacuum contactor: VSC type UniSec switchgear SF 6 switch disconnector: GSec type m 1VDCD6006 (VD4/R-VD4/L VD4/UniAir VD4/ UniMix 12 24kV 630 120A 12 2kA Installation and maintenance manual) 1VCD600189 (Vmax 12 17.kV 630 120 A 16 31.kA Installation manual) 64764 (VD4 12 24Kv 630 310A A 16 0kA Installation and maintenance manual) 647021 (HD4 12-40. kv 630-3600 A 16-0 ka Installation and maintenance manual) 600192 (VSC VSC/F VSC/P VSC/PN VSC/PNG 7.2/12 kv 400 A Installation and maintenance manual) 1VFM20000 Operation and maintenance manual 1VCD60111 Instruction for installation, generation and maintenance

DISTRIBUTION SOLUTIONS 9 Maintenance instructions Maintenance includes the following activities: Inspection: evaluation of the effective conditions Overhauling: actions to preserve the specified conditions Repairs: actions to restore the specified conditions The frequency with which some apparatus/ components (e.g. parts subject to wear) must be inspected and serviced is determined by fixed criteria, such as switching frequency, length of service and number of short-circuit breaking operations (consult the specific maintenance manuals in table 2 for detailed information). For other parts, the frequency may depend on: different ways of operating in specific cases, work load, environmental factors (including pollution and aggressive air), etc. The frequency with which maintenance work must be performed always depends on the operating conditions of the switchgear, e.g. the way of operating, the number of rated and short-circuit current switching operations, the ambient temperature, degree of pollution, etc. The maintenance intervals and actions to be taken are described in Table 3 below and are recommended for UniSec switchgear under normal service conditions. Shorter intervals are recommended for all maintenance activities in more demanding conditions (such as areas with high pollution levels). Please contact ABB for more details. Table 3 Maintenance intervals and activities in normal service conditions. Classification Recommended activities "Time interval According to in Years (normal number conditions)" of operations Switchgear Inspection Visual check for dirt, corrosion or moisture Overhauling Repairs Check for effects of high temperature on the main circuits Check for traces of partial discharge and current leakage on insulating material parts Visually check the surface of the contacts (signs of overheating) Check the general condition and lubricate the earthing switch contacts Check the correct mechanical/electrical operation of accessories, interlocking, auxiliary and signalling devices of switchgear Tighten all electrical connections (main busbars, switches, measuring devices, cables, etc.) to the correct torque as specified in the installaton and tightening torque instructions Clean all parts (disconnectors, circuit breakers, tripping mechanisms, motors, etc.) with a vacuum cleaner and visually inspect them Perform a closing/opening operation on all disconnectors and circuit breakers, including the earthing switches Perform one electrical operation sequence on all motor-operated devices and tripping mechanisms Clean the busbars, cable compartment, GSec switch-disconnector both insulated and metal parts, instrument transformers, circuit breaker, etc. Grease the contacts, blades and operating mechanism (Earthing Switch) When required, replace the parts subjected to mechanical stress (Earthing switch and operatinf mechanism) Carry out repair work immediately after a defect has been discovered Completely remove all rust from damaged paintwork areas on steel sheet and other steel parts Lightly roughen the surrounding paint and carefully degrease the entire surface. Then immediately apply an anti-rust primer and apply the top coat Carefully remove any oxidation from galvanized surfaces According to product manual According to product manual As required As required As required As required

10 UNISEC - MAINTENANCE MANUAL Traditional preventive maintenance Table 3 Inspection Apparatus (Circuit Breaker and Switch Disconnector) Visual inspection to check for any contaminations, traces of corrosion or electrical discharge phenomena Visual inspection of the poles or cover (resin parts) Visual inspection of the isolating contacts. The contact system should be turned alternately in order to keep the interval surface of the contact area clean. The contact areas must be cleaned when there are signs of overheating Visual inspection of the components, especially those which may be damaged by incorrect operations. Carry out functional tests of the locks, checking their correct operation and activation without abnormal force (If withdrawable assembly) Check the operating pressure of the gas-insulated devices (if with SF 6 ) Measure of the insulating resistance Operating mechanism Visual inspection to check the operating mechanism, the lubrication conditions of the jaw isolating contacts, the sliding surfaces, etc. Carry out a few opening and closing operations Make sure that the electrical and mechanical operations of the various devices are correct, with particular attention to the interlocks Overhauling Clean the surfaces, the insulating surfaces and the conductive parts When required, replace the parts subjected to mechanical stress Repairs When required, replace the parts subjected to mechanical stress As required Inspection & Overhauling ITs and Sensors Visible surface pollution shall be cleaned off the transformer Repairs In case of surface contamination please contact ABB As required Inspection & Overhauling Protection Devices Check the correct mechanical/electrical operations of the protection devices Repairs When required, please contact ABB As required

DISTRIBUTION SOLUTIONS 11 Spare parts ABB offers a broad range of spare parts for your switchgear, thereby allowing you to address the important requirements of the future. ABB possesses extensive experience with medium voltage switchgears and can provide you with a detailed list of recommended spare parts based on the lifecycle of your switchgear. Unexpected situations able to cause delays in your start-up plan may occur during the installation and commissioning process of a switchgear if you do not have the required spare parts in stock. ABB can provide a recommended list of spare parts, including the most frequently replaced components for: Easy availability during commissioning activities Rapid replacement or repairs Preventing start-up delays due to unexpected failures in the most common components Ensuring you have a minimum number of replacement parts in stock for your switchgear Spare parts classification Skilled technicians are required to replace parts, which are classified according to the following levels: L1: parts that can be replaced directly by customers by following the instructions in the user manual or, better still, after having attended an L1 training course (introductory training for apparatus operators) L2: parts that can be replaced directly by customers by following the user manual instructions of the apparatus or, better still, after having attended an L2 training course (advanced training for maintenance technicians and site operators) L3: parts which can only be provided when needed for qualified ABB maintenance or repairs. These parts require dedicated tools and specific in-depth skills in order to be replaced Additional information and details are available in the dedicated publication below: 1VCP000691 - UniSec - Spare parts for improving switchgear availability.

For further details please contact: More product information: abb.com/mediumvoltage Your contact center: abb.com/contactcenters More service information: abb.com/service The data and illustrations are not binding. We reserve the right to modify the contents of this document following technical developments. Copyright 2018 ABB. All rights reserved. 1VCP000791 - Rev. A, - en - Maintenance manual - 2018.08 (UNISEC) (gs)