FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

Similar documents
Product descrption Pump FZ-A

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

CXL2 Injectors & Manifolds

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R8 08/18

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

Product description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES

3000 psi (207 bar) Output/ min. 115 VAC 10cc (0.61 cu. in.) 24 VDC 12cc (0.73 cu. in.) Discharge Element Output Port.

MultiPort II Lubricator

DESCRIPTION OPERATION. Product description Electrical Pump FZB

SureFire II Lubricator

SureFire II Lubricator

Progressive Central Lubrication System

MultiPort II Lubricator

M OTO R. The electric motor. DC - direct current voltage.

MOTOR. The electric motor. DC - direct current voltage.

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

Bijur Delimon Lubrication Equipment

LUBRICATION PUMP UCF CENTRAL LUBRICATION

OWNER S TECHNICAL MANUAL

Operators Manual TTN LUBRICATOR Series Progressive r#9

LubeSite 500 Series. Grease, Metal Base, Corrosion Resistant. General. Application. Operation. Technical Data R0 06/09

400 psi (28 bar) PDI & INJ. 100 psi (7 bar) PDI & INJ

ZEM Injector. Series 32, 33, 34, 35, 39. General. Operation. Features. Technical Data. Injector Outputs R2 08/10

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

TriboTec LUBRICATION PUMP VEG

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

Lubemaster Pump DESCRIPTION

number of outlets 1 2 lubricant output per lever movement 2 cm 3 (0.122 in 3 ) 2x1 cm 3 (2 X in 3 )

Pump Autolub-M. Product description APPLICATION PRODUCT CHARACTERISTICS FUNCTION

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

DUOFLEX lubrication pumps

Series 1000 Divider Valve Manifold

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Airmatic Lubricator. Pneumatic Operation, Oil. General. Application. Operation. Technical Data

Overview - Bijur - Mechanical - Spindle Lubrication - Oil Pump

LUBRICATION PUMP UCD

Pressure Measurement Fittings

CONTINENTAL HYDRAULICS LPV SERIES AXIAL PISTON PUMPS

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

Fill cap with inlet strainer (40 mesh) Automatic approved quick connect inlet (no strainer)

Service Handbook HD /97

Series 3000 Divider Valve Manifold

Dual-line lubrication systems. Pumps and pump units. Grease. SKF Maxilube Lubrigun PowerMaster III PUB LS/P EN

LUBRICATION PUMP VEG CENTRAL LUBRICATION

ZAMA CUBE CARBURETOR DISASSEMBLY AND SERVICE

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

Oil Streak Air-Oil Generating Unit

Multi-line and Progressive Systems

DD & DM Valves. Dualine, Grease & Oil. General. Operation. Features. DM Valve. DD Valve R5 09/12

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

DP33 Pump. 60:1, 3+3, Air-operated, Grease. General. Operation. Technical Data. Installation R2 08/15

Hydraulic pump HP-1. Type 1. Type 2

Ebara Submersible Sump Pumps

TWO-LINE ELECTRIC CHANGE-OVER VALVE

Grease Lubrication Pump FK

Operating manual. Pump Dynamis BA_2017_1_GB_DYN. 1 BIJUR DELIMON INTERNATIONAL BA_2017_1_GB_DYN (Rev. B)

DM Valve LINE 1 LINE 1 LINE 2. Positive indication at every bearing. adding or subtracting points at every bearing. Has only two moving parts.

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

Grease-lubricating pump FF... DSK US (05.05)

Part No. Description Part No. Description

farval DUaLINE SYSTEMS Ideally suited for heavy industry Continuous duty operation Over 80 years of excellence

Injection Oilers, Micro Pumps

SITRANS F flowmeters. SITRANS F R Drum meters Overview 4/355. Overview

Greasing machines MPD 60-1, MPD 60-2

DESCRIPTION OPERATION. Product descripption SureFire Electrical Pump

SW14.5TI INTEGRAL HYDRAULIC FLANGE SPREADING WEDGE. Repair Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

Lincoln Multi-line and progressive systems

16000SIII Automatic Grease System

Lubrication Systems. Section 26

DM Valve LINE 1 LINE 1 LINE 2. Positive indication at every bearing. No small ports No system redesign when

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

DP556 Pump. 55:1, Air-operated, Grease. General. Operation. Technical Data. Installation. Mounting with Reinforced Cover (Recommended)

Single- and Multicircuit Pumps

Hydraulic Motor (Radial piston multi-stroke)

Single-Line Centralized Lubrication Systems

Levelling valve

INSTRUCTION MANUAL. Portable Greasing System S1180, REV C GS

Bulletin No.: PRO Effective Date: 10/30/69 Cancels: N/A Page: 1 of 9

Injection oilers, micro pumps for minimal quantity metering

FARVAL DUALINE SYSTEMS. + Ideally suited for heavy industry + Continuous duty operation + More than half a century of excellence

INSTRUCTION MANUAL ÅSSA LUBRICATORS TYPE FL & TYPE FE

Radial piston motor for wheel drives MCR-F

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

funnels, measures, gravity cocks, jerry cans and oil suction pumps...

Progressive Block Distributor PVB

I N S T R U C T I O N M A N U A L

DROPS INSTEAD OF LITRES!

Component List for Graco Trabon Lubrication Systems Products

FARVAL DUALINE SYSTEMS + + Ideally suited for heavy industry + + Continuous duty operation + + Over 80 years of excellence

DM Valve LINE 1 LINE 1 LINE 2. Positive indication at every bearing. adding or subtracting points at every bearing. Has only two moving parts.

General Equipment. Content - Section 8. Grease Nipples. Grease Equipment. Garage Equipment. Coils, Plugs & Sockets. Electrical Cable.

REV lubrication systems PEGPEO Electropumps for progressive systems

Electric Pump EP-1. Electric pump EP-1 with steel reservoir and pump element PE-120 V with manometer:

MULTILINE LUBRICATOR Working Type of drive

Axial Piston Variable Pump A2VK

Identify and Assemble the Pneumatic Components

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Transcription:

FZ- Lubricator Electric, Oil & Grease General The FZ- Lubricator is primarily designed for direct feed applications for servicing up to 12 lubrication points. The lubricators are supplied with pump bodies comprising either a single row of outlets (1-6) or a double row of outlets (1-12). Discharge is adjustable for each outlet or set of outlets via adjusting spindles located at the top of the pump body. Service to more than 12 lubrication points can be accomplished by installing progressive dividers downstream of the lubricator. FZ- lubricators are typically driven by a flange mounted motor or via the machine being lubricated through either a ratchet or rotary drive. Maximum permissible speed of the piston plunger is 10 rpm for rotary drive lubricators and 6 rpm for ratchet drive. wide range of transmission ratios are available making this lubricator adaptable to meet a diversity of machine requirements. pplication The FZ- Lubricator is predominantly intended for multiline centralized lubrication systems. The pump is usually driven by the flange motor or by the machine to be lubricated via an oscillating lever or coupling. Working outlets should never be plugged. Plugging a working outlet will result in pump damage. Contact Bijur Delimon representatives for consultation. Refer to Operators Manual: FZ-. Operation The FZ- Lubricator incorporates a single piston plunger connected to a cam plate. Rotation of the cam plate and contact with a pressure cam allows for the suction and pressure stroke of a grooved piston. The vertical grooves align themselves with each outlet or set of outlets during the pressure stroke discharging up to 0.1cc (0.006 cu. in.) of lubricant per outlet per rotation of the piston plunger. The adjusting spindle determines the actual stroke of the piston corresponding to each outlet or set of outlets. djustment of Discharge Rate The figures 0-4 are stamped on the adjusting spindles. The maximum delivery 0.1cc (0.006 cu. in.) is obtained in position 4. The volume delivered is reduced by turning the adjusting spindles clockwise. To ensure reliable delivery from the lubricator, output should be no less than 1/4 of the maximum rating. If you are using a pump with 7-12 outlets installed, the output rate of two outlets, located one above the other, is adjustable by one adjusting spindle. Features ++ Robust components for harsh and severe applications ++ Grease agitator and reservoir wedge plate assures delivery of grease to piston chamber ++ daptability to various drive speeds of the machine to be lubricated, eliminating the need for additional control systems ++ utomatic refill capabilities utilizing ultrasonic high/low level switch and fill port connection ++ daptable to progressive systems and gear spray systems 1

Technical Data Reservoir Capacity 8 liter (16. lb) dditional sizes available upon request. Permissible Lubricants Suitable for oil and grease up to NLGI grade 000-2 Number of Outlets (Optional) 1 to 12 Maximum Permissible Feed Pressure Maximum Permissible Piston Speed Delivery Volume Per Outlet for One Rotation of Piston Plunger Maximum Delivery Volume Per Outlet Per Hour* Operating Temperature Outlet Thread Connection 2900 psi (200 bar) 36 psi (0 bar) for short periods only 6 rpm (with ratchet drive) 10 rpm (with running drive) 16 rpm (with oscillating drive) 0 to 0.1cc (0 to 0.006 cu. in.) djustable 60cc (3.66 cu.in.) 36cc (2.2 cu.in.) ratchet drive -4 F to 176 F (-20 C to 80 C) 1/4 BSPP Drive Type and Transmission Ratios Ratchet 3:1, 12:1, :1, 0:1 Filler Valve Low Level Switch (Optional) Free shaft 3:1, 12:1, :1, 0:1 Transmission gear 9:1, 21:1, 34:1, 710:1, 1420:1, 2880:1 Transmission gear w/ flange motor 21:1, 34:1, 710:1, 1420:1, 2880:1 Optional (Fill the grease reservoir by means of a forced-fed barrel pump.) Ultrasonic * Delivery volume from all outlets can be reduced by selecting a lower driving speed or higher gear ratio, so that the piston plunger rotates at less than 10 rpm and 6 rpm, respectively. Start Up Instructions Installing and Connecting the Lubricating Pump The pump should be installed and mounted vertically. Connection of the motor to be control box must be carried out in accordance with the appropriate circuit diagrams. Filling the Lubricant Tank and Piping ll piping must be carefully cleaned before descaling and blowing through and filled with clean grease using a grease gun. For initial start-up, the grease tank is first filled up to the strainer with oil and then with grease, because otherwise a longer start-up time is required to allow venting. Before connecting the piping the pump must operate long enough at full capacity to ensure that the grease emerges evenly and without air from each outlet. Next, the piping should be connected (use sealing washers), until air-free grease emerges at the ends of the piping. Once the bearings to be lubricated are also filled with grease, the piping can be connected to the lubricating points. The system can be started after adjustment of the required lubricant quantity. 2

Setting the Delivery Rate t full capacity, corresponding to 0.1cc lubricant per discharge and piston stroke, an arrow on the discharge identification points to the number 4 stamped on the head of the setting spindle. By turning the spindle clockwise the delivery is reduced. Reduction below 1/4 of the maximum delivery (setting 1) should be avoided. In case of pumps with 7 to 12 outlets, the delivery rate of two vertically arranged outlets is adjusted by means of an adjusting spindle. The second arrow of the discharge identification points to the outlet bore relating to the setting spindle. By changing the drive speed or the internal gear ratio of the pump or also by changing the altitude of the oscillating lever, the output volume of all outlets and thus the overall output volume is changed. Customer should specify 1 or 2 outlets at time of order. Do not attempt to simply plug an outlet as this may damage the pump. Maintenance Filling the Grease Tank s soon as approximately 3/4 of the tank capacity are consumed, the grease tank should be refilled. The grease level should never drop to a level where the feed screw is visible, because air may otherwise penetrate into the piping. During filling, care should be taken to ensure that only clean grease is used and no dirt penetrates into the tank when the cover is opened, because this may result in malfunctioning. Filling via a filling valve and firmly installed pipelines is at all events to be preferred. How to Order FZ Number of Outlets 01 1 outlet 02 2 outlet 03 3 outlet 04 4 outlet 0 outlet 06 6 outlet 07 7 outlet 08 8 outlet 09 9 outlet 10 10 outlet 11 11 outlet 12 12 outlet ccessories 00 Without 01 Ultrasonic level switch 02 Filler valve 03 Ultrasonic level switch & filler valve Reservoir Capacity 8 liter (16. lb) Drive Position O Ratchet or free shaft Motor or transmission (left side) E Motor or transmission (right side) Revision Level Revision Motor Options 01 Ratchet drive 3:1 02 Ratchet drive 12:1 03 Ratchet drive :1 04 Ratchet drive 0:1 0 Free shaft 3:1 06 Free shaft 12:1 07 Free shaft :1 08 Free shaft 0:1 09 Free shaft w/ transmission 9:1 10 Free shaft w/ transmission 21:1 11 Free shaft w/ transmission 34:1 3 12 Flange motor 230-260/0-460/0/60 Hz 21:1; Three phase 13 Flange motor 230-260/0-460/0/60 Hz 34:1; Three phase 14 Flange motor 230-260/0-460/0/60 Hz 710:1; Three phase 1 Flange motor 230-260/0-460/0/60 Hz 1420:1; Three phase 16 Flange motor 230-260/0-460/0/60 Hz 2880:1; Three phase Flange motor w/transmission 11 VC/60 Hz 21:1; Single phase 6 Flange motor w/transmission 11 VC/60 Hz 34:1; Single phase 7 Flange motor w/transmission 11 VC/60 Hz 710:1; Single phase 8 Flange motor w/transmission 11 VC/60 Hz 1420:1; Single phase 9 Flange motor w/transmission 11 VC/60 Hz 2880:1; Single phase

Dimensional Schematics Ratchet Drive Free Shaft Measurements shown in millimeters. B 2 116 6 ø108 C 0 196 139 24 6 48 ø22.4 ø20h6 48 102 10 22 23 6 Close-up of C 164 134 72 11 30 144 Reservoir Capacity B* 2. liter 330mm mm 8 liter mm 76mm * Height with the lid open. 4

Free Shaft with Transmission Flange Motor Measurements shown in millimeters. ø16h6 22 ø124 84 84 18 36 317. 114. 72 131 30 106. 10 MX DI ø90mm