Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance free battery Lockable battery isolator switch Powder coated canopy (Only for Soundproofed sets) 50 radiator Oil pump on the engine Steel base frame with fork holes Vibration isolators between the engine/alternator and base frame Dry type air filter Base fuel tank for daily running Drain points for fuel tank Operation Manual / Specifications Model Length (L) Width (W) Height (H) Dry Weight kg WPS250 2936 1060 1756 2196 WPS250S 4250 1400 2150 3147 Notes: *** Dimensions and Weights *Prime Power Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; **Standby Power Standby duty, operation under variable load, without over load; Standard Reference Conditions Note: Standard reference conditions 25 C (77 F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Output Ratings Generating Set Model Prime Power* Standby Power** WPS250 250kVA/200kW 275kVA/220kW WPS250S 250kVA/200kW 275kVA/220kW Ratings at 0.8 power factor Ratings and Performance Data Engine Make & Model: Alternator Brand: Alternator Model: Control System: Circuit Breaker Type: Frequency & Phase: Perkins 1306C-E87TAG6 Leroy somer LSA46.2L6 Auto Gen Engine Speed: RPM 1500 Fuel Tank Capacity: litres WPS250 WPS250S Fuel Consumption: l/hr (100% ) Power -Standby Power 3 Pole MCCB 50Hz & 3PH 435 660 54 59 1/ 5
Engine model:1306c-e87tag6 Engine Technical Data No. of Cylinders / Alignment: Cycle: 6/Vertical, in-line 4 Stroke Bore / Stroke: 116.6/135.9 Induction: Cooling Method: Governing Type: Governing Class: Turbocharged Water cooled Electronic BS 2869 CLASS A2 Compression Ratio: 16.9:1 Displacement: 8.7L Moment of Inertia: kg m² 0.536 Engine Electrical System: - Voltage / Ground - Battery Charger Amps Weight: kg - Dry - Wet 24/Negative 24/50 889 939 Cooling System Capacity with Radiator: l 24.2 Capacity without Radiator: l Energy to Coolant and Oil: kwt Energy to Radiation: kwt 9 11 98 101 Energy to Cooling Fan: kwm 11 Radiator Cooling Airflow: m³/min ( 440 External Restriction to Cooling Airflow: Pa Designed to operate in ambient conditions up to 50 C (122 F). Contact your local PowerLink Dealer for power ratings at specific site conditions Performance Engine Speed: rpm 1500 Gross Engine Power: kwb 228 250 BMEP: kpa 2099 2298 Lubrication System Oil Filter Type: Spin-On, Full Flow Total Oil Capacity: l 26.5 Minimum: l 22.7 Oil Type: API-CI-4/DHD-1 Fuel System Fuel Filter Type: Replaceable Element Recoended Fuel: Diesel Class A2 Fuel Consumption: l/hr Prime 110% 100% 75% 50% WPS250 49.7 45.0 36.0 24.0 WPS250S 49.7 45.0 36.0 24.0 (Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2) Oil Cooling Method: Water-cooled Exhaust System Air Systems Silencer Type: Exhaust Outlet Size: Silencer Noise Reduction Level: Maximum Allowable Back Pressure: kpa Industrial 10.7 Air Filter Type: Combustion Air Flow:kg/s Dry Paper Element 0.29 0.31 Exhaust Gas Flow: kg/s 0.30 0.32 Max. Air Intake Restriction: kpa -clean filter -dirty filter 2.5 6.22 Exhaust Gas Temperature: C 579 579 The weights are approximate and without fuel. 2/ 5
Alternator model: LSA46.2L6 Alternator Physical Data Manufactured for FG Wilson by: Leroy somer Model: LSA46.2L6 No. of Bearings: Single Insulation Class: H Winding Pitch Code: 2/3 Wires: 12 Ingress Protection Rating: IP23 Excitation System: SHUNT, AREP or PMG AVR Model: R250, R450 Alternator Operating Data Overspeed: rpm 2250min 1 Voltage Regulation: (Steady state) ±0.5% Wave Form NEMA = TIF: <50 Wave Form IEC = THF: <2% Total Harmonic content LL/LN: No load <2.5% on load <2.5% Radio Interference: Radiant Heat: kw (Btu/min) -WPS250 -WPS250S Alternator WPS250 WPS250S Performance Data: Data Item Motor Starting Capability* kva Short Circuit Ratio** % Reactances: Per Unit Xd X'd X"d 462/504 462/504 0.41 0.41 327 327 15.5 15.5 9.3 9.3 Voltage Technical Data WPS250 Voltage Prime: Standby: kva kw kva kw 380/220V 250 200 254 203 400/230V 250 200 260 208 415/240V 240 192 254 203 Voltage Technical Data WPS250S Voltage Prime: Standby: kva kw kva kw 380/220V 250 200 254 203 400/230V 250 200 260 208 415/240V 240 192 254 203 3/ 5
Control System PLC-7420 FEATURES Microprocessor control, with high stability and credibility. Mains supply and generator operation monitoring. Indicating operation status and fault conditions. Multiple protections; multiple parameters display, such as pressure, temperature. Manual and automatic work mode selectable. Real time clock for time and date display, overall runtime display, 99 log entries. Overall power output display. Integral speed/frequency detecting, telling status of start, rated operation, overspeed. Counication with PC via RS485 or RS232 interface, using MODBUS protocol. Engine ECU is available. Coon USB cable is usable for parameter configuration. Multi-language is available. PLC-920 (Optional) FEATURES Parameter configuration via RS-232 serial counication; Log last 50 events & alarm information with measured values; Statistics records; Remote start/stop; Speed sensing from alternator voltage or magnetic pickup; Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection; Automatic transfer switching control and engine control; Adjustable start, load and stop timers. 4/ 5
Optional Engine Alternator Generator Set Fuel System Canopy Water Jacket Preheater Oil Preheater Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Fuel T-valves Trailer Lubricating System Exhaust System Cooling System Control System Voltages Oil with the machine Protection board from hotness Front heat protection Coolant (-30 C) Remote control panel PLC-920 ATS 415/240V 400/230V 380/220V 220/127V 200-115V The following lists are optional by the needs of customers. Minor Repair / 1000 hrs optional No. Part Name Part No. Qty Remark 1 Fuel Filter 26560137 6 2 Oil Filter 26540244 6 3 Air Filter 26510289 5 4 BELT 1841559C1 1 5 SEAL ROCKER BOX COVER 1825602C91 1 6 GASKET CYLINDER HEAD 1830189C2 1 7 THERMOSTAT 1830256C93 1 8 FRONT OIL SEAL 1833096C94 1 9 SEAL REAR END OIL 1817867C92 1 If you have any question or inquiry, please contact PowerLink sales organization or contact: info@powerlinkworld.com Local Distributor Specification may change without prior notice. For more info, please contact PowerLink or your local distributors. /2013 1 st Edition 5/ 5