DIGITAL CLAMP TESTER MODEL HCL-5000D

Similar documents
ROGOWSKI LEAK METER MODEL RLM-1

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL

Clamp Earth Tester MET-2. Instruction Manual

Safety design conforming to the following provisions

OPERATING INSTRUCTION

DIGITAL RCD(ELCB) TESTER

1.Safe testing IMPORTANT:

Safety design conforming to the following provisions

Table of Contents Title Page No.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

User's Manual. Earth Ground Resistance Tester. Model Introduction

User Guide. Model Insulation Tester / Megohmmeter. Introduction

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

OPERATING INSTRUCTION

Marin Control Digital

Lumitester PD-20 Control Kit

Model Battery Powered Milliohm Meter

TOWA SEIDEN INDUSTRIAL CO., LTD.

INSTRUCTION MANUAL DM5B Fax: (503)

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

OPERATING INSTRUCTIONS

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

MANUAL. Single charger

HST-BL-2830MS & HST-BL-2830MS-USA

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Digital/Analog Megohmmeter Model 1026 USER MANUAL

HI-POT/CONTINUITY TESTER Model PLEP01

Sonic Meter. Soni. Operating Manual. Rev. A

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Dawson DDM190D. Digital Multimeter User s Manual

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

Filterpack FR-BFP2-(H)0.4K to (H)15K

Phase Sequence Tester

Video & Power Over Coax Kit

Lumitester PD-30. Instruction Manual. Table of Contents

BEFORE USING THE PRODUCT

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Digital/Analog Megohmmeter Model 1026

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

INSTALLATION INSTRUCTIONS

Model Insulation Tester / Megohmmeter. User Manual

DIGITAL EARTH RESISTANCE Model KM 2030

For technical questions and replacement parts, please call

MCA-700Ⅱ JAPAN BONKOTE CO.,LTD. Instruction manual. Preparation in April The 1st edition

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

FX2N-2LC SPECIAL FUNCTION BLOCK

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

EVS RP6020. Instruction Manual

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

Operators Manual. Recirculating Chiller /06/08

Pressure Transmitter

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

TMD90A Dual Input Digital Thermometer

I. Safety precautions

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Doc. No. NDP 149M-05 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-10Fi DP-20Fi

OPERATING MANUAL CMP-200

AT8020. Breath Alcohol Tester. Using manual. Ver:HW

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

OPERATING INSTRUCTIONS

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

User Guide. Model Insulation Tester / Megohmmeter

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

SPECIFICATION FOR APPROVAL CHARGER JBC036-11

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

OPERATING INSTRUCTION

Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER. Model : EMF-828

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

82V LITHIUM-ION BATTERY CHARGER GC 400

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

EC1 Pocket Conductivity Tester Instruction Manual

Installation manual wall-mounted distributor

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Manufacturer Kakogawa, Japan DC5S

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

BATTERY & STARTER ANALYSER (BSA-12) User Manual

Read and understand this manual for safely usage.

Transcription:

DIGITAL CLAMP TESTER MODEL HCL-5000D INSTRUCTION MANUAL Thank you very much for selecting our digital clamp tester model HCL-5000D for AC line current in Hi-voltage circuit. This model is complex instrument and employ a very reliable mechanical/electronic design. Before you use your new instrument, read this instruction manual completely and familiarize yourself thoroughly with all functions and keep this instruction manual carefully to take out whenever you need. MULTI MEASURING INSTRUMENTS CO.,LTD. Akihabara Murai Bldg., 7F, 1-26 Kanda Sakuma-cho, Chiyoda-ku, Tokyo, 101-0025 Japan TEL : 81-3-3251-7016 FAX : 81-3-3253-4278 Home Page : http://www.multimic.com/ E-mail : multi@multimic.com

1. SAFETY SUMMARY observe by all means To use this instrument safely, read this SAFETY SUMMARY carefully and apply the instrument correctly. The CAUTIONs and WARNINGs which appear on the following pages are stated to prevent the operator & other people from the dangers and their properties from the damages beforehand.! WARNING : This symbol indicates the contents "Possibilities of the death or the serious wound can be supposed" caused from mis-operations.! CAUTION : This symbol indicates the contents "Possibilities of the injury or only the material damage can be supposed" caused from misoperations.! WARNING POSSIBLE ELECTRICAL SHOCK When using this instrument in the circuit more than AC 1000V, operate very carefully (always wear the rubber gloves). Apply only the coated cables and do not clamp the bare cables. Do not handle the instrument in the rain, at humid place, with a drop of water and or with wet hands. Do not use the instrument if the CT case, instrument body and or rubber handle cover are damaged. Replace the rubber handle cover to new one, if it is damaged. Do not disassemble this instrument High voltage circuit is very dangerous and people without expertise should not operate the instrument.

2. SPECIFICATIONS Measuring Method Measuring Function Display Measuring Range Accuracy :Dual integration mode :AC Current by clamping CT :3.5 digit LCD, max. 1999 count : 0-20A/600A (50/60Hz), two range manual :23 o C±5 o C, 80%RH or less Range Resolution Accuracy 20A 0.01A 0~20A ±2%rdg±8dgt 600A 1A 0~400A ±2%rdg±9dgt 1A 400A~600A ±3%rdg±10dgt Jaw Opening Capability: :φ35mm Overload Indication: :Blanking of all digits except MSD 1 Data Hold : DH mark on the display for holding measured data Low Battery Indication : B mark on LCD readout Sampling Auto Power Off :2 times/second :approx. 5 minutes after power on Operation Circuit Voltage :AC 80V 7000V Insulation Resistance :100M ohm or more (between handle and CT core) Withstanding Voltage :AC 15KV, 1 minute (between handle and CT core) Power Supply :UM-3 (1.5V) x 2 pcs. Operating Temperature Storage Temperature :0~40 less than 80%RH without condensation :-10 ~60 less than 80%RH without condensation Dimension Weight :70(W)x356(H)x32(D)mm :Approx. 370 g (including batteries) Accessories Carrying case.1 Instruction Manual...1 Batteries..2

3. DIMENSION & PANEL 70 51.5 1 Clamp CT : CT sensor detecting the current by clamping method. 2 Open/Close Guide for CT : Clamping/releasing CT to or from the conductor by pushing /drawing this part. 3 Power Switch : Switch for power on and off. 4 Range Switch : Switch for range selection of 2000mA/20A 5 Display : LCD readout the measurement value, B battery sign and DH data hold mark. 6 Data Hold Switch : Push once this switch to hold the data and DH mark will appear on the display. Push once again to release. 7 Battery Cover : Remove this cover to install or replace batteries. 8 Grip : Grip part for handheld. 4. OPERATION 4-1 PREPARATION BEFORE MEASUREMENT Battery Installment: 1 Confirm the power switch OFF. 2 The battery cover is fixed by screw and turn it to the left for removing cover. 3 Install the batteries according to the indication of battery case (do not mistake to place + and - polarity). 4 After the replacement, put the battery cover to the original position firmly.

B sign will appear on the display when batteries are exhausted and get less than operation voltage. Replace to new batteries immediately. Do not use the batteries mixed new one and once used and or different kind ones.! WARNING POSSIBLE ELECTRICAL SHOCK OR ACCIDENT Do not replace the batteries under the conditions of measuring current or voltage Do not operate the instrument with battery cover off.! CAUTION When not using the instrument for a long period, remove the batteries and keep separately. The batteries may leak and may cause damage to the instrument. 4-2 OPERATION METHOD 1 Power switch on and select the appropriate range to be measured by range select switch. 2 Push up CT guide to the conductor to be measured for clamping CT. 3 Push Data Hold switch to hold measured value. 4 After measurement, pull out CT from the conductor and read the measured value. 5 Set power switch off after finished operation. Cable to be measured When B mark appears on LCD during measurement, replace the batteries immediately, as the batteries are consumed and get lower than operation voltage.! CAUTION POSSIBLE DAMAGE OF INSTRUMENT Do not apply the current more than 20A to the instrument, as it may cause damage and heating by giving excess big current to CT. This model is high precision measuring instrument. It may cause defect, if CT part receives heavy load.

REPAIR SERVICE When requesting for repair service, please bring the instrument directly to the dealer where you bought. When mailing the instrument, always pack it in its original or equivalent packing materials to avoid any damage during the transportation and also put together with documents showing your name, address, phone number and defect point. WARRANTY This instrument is sent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our workmanship or the original parts, Please contact the dealer where you bought the instrument. The warranty period is 12 months from the date of purchase and the instrument shall be repaired at free of charge, provided that we judge the cause of defect is obviously resulted from our responsibility. GURANTEE REGULATIONS 1. This instrument is warranted for the operation under normal use for 12 months from the date of purchase. 2. This warranty does not cover the following defects: a. Defect caused from the improper use and operation. b. Defect caused from the use, operation and storage beyond the original specifications, designs and conditions. c. Defect caused from the renovations or repairs done by someone else than us or our representatives. d. Defect not caused from our responsibilities.