Data sheet: Wilo-VeroLine-IPL 1/145-1.5/4 Pump curves 4-pole, 5 Hz H[m] Qmin 1 8 Wilo-VeroLine-IPL 1/175 - Wilo-VeroLine-IPL 1/135 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures (for -4 vol.% glycol and fluid temperature 4 C) 6 IPL 1/175-3/4 Cooling and cold water 4 P [kw] 3 η p[%] IPL 1/165-,/4 IPL 1/145-1,5/4 IPL 1/135-1,1/4 1 3 4 5 4 8 1 16 Q[m³/h] Ø 157 Ø 141 1 Ø 134 4 8 1 16 Q[m³/h] 8 6 4 4 8 1 16 Q[m³/h] Dimension drawing Ø 177 NPSH [m] Q[l/s] DN 1 8 6 4 Heat transfer oil Special version at additional charge Permitted field of application Standard version for operating pressure Special version for operating pressure p max p max Temperature range at max. ambient temperature +4 C 1 bar 16 bar -...+1 C (depending on the fluid) Max. ambient temperature +4 C Installation in closed buildings Outdoor installation Special version at additional charge Pipe connections 15 Nominal flange diameter DN 1 8 x Ø 19 Ø 156 Ø 18 Ø Flanges (according to EN 19-) Flange with pressure-measurement connections PN 1 (PN 16 on request) R 1 / 8 43 1 II 6 Note: 1 II III 3 x M1 356 159 197 c 6 5 146 6 5 Housing with feet for installation on a base, brackets on request; II Pressure measuring connection R1/8; III Ventilation R1/8 Materials Pump housing EN-GJL-5 Lantern EN-GJL-5 Impeller EN-GJL- Impeller (special version) Pump shaft 1.41 [AISI4] Mechanical seal AQEGG Other mechanical seals On request Terminal diagram W U V U1 V1 W1 L L 1 L3 PE W U V U1 V1 W1 L L 1 L3 PE : Connection diagram delta connection Y: Connection diagram star connection Motor protection switch required on-site. Check the direction of rotation! To change the direction of rotation, exchange any two phases. P 3 kw P 4 kw 3~4 V Y 3~3 V 3~69 V Y Subject to change without prior notice. 3~4 V www.wilo.co.uk 5 Hz 15-1 / 8 After removing the bridges, Y- start is Electrical connection Nominal speed n 145 rpm Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI).4 Pump with max. impeller diameter for determining the MEI Motor/electronics IPL1/175-3/4
Data sheet: Wilo-VeroLine-IPL 1/145-1.5/4 Integrated full motor protection Special version with PTC thermistor sensor (KLF) at additional charge Protection class IP 55 Insulation class F Rated current (approx.) I N 3~4 Motor efficiency level V 3.3 A IE Motor efficiency Power factor η m /η 5% m /η 75% m 1% cos φ 78.7/81.3/8.8 %.79 Nominal motor power P 1.5 kw Motor winding up to 3 kw Motor winding from 4 kw 3 V Δ/4 V Y, 5 Hz 4 V Δ/69 V Y, 5 Hz Installation options Pipe installation ( 15 kw motor power) Support-bracket mounting Information for order placements Weight approx. m 71 kg Make Wilo Type VeroLine-IPL 1/145-1.5/4 Art no. 89566 Observe motor name plate data Subject to change without prior notice. www.wilo.co.uk 5 Hz 15- / 8
Dimensions and dimension drawings: Wilo-VeroLine-IPL 1/145-1.5/4 Dimension drawing Ø 177 DN 1 8 x Ø 19 15 Ø 156 Ø 18 Ø 43 146 II II III 159 1 c 3 x M1 1 197 356 6 6 6 5 5 Note: Housing with feet for installation on a base, brackets on request; II Pressure measuring connection R1/8; III Ventilation R1/8 Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-3 / 8
Pump curves: Wilo-VeroLine-IPL 1/145-1.5/4 Pump curves 4-pole, 5 Hz H[m] 1 Qmin Wilo-VeroLine-IPL 1/175 - Wilo-VeroLine-IPL 1/135 8 6 IPL 1/175-3/4 4 IPL 1/165-,/4 IPL 1/145-1,5/4 IPL 1/135-1,1/4 4 8 1 16 NPSH [m] Q[m³/h] 8 6 4 P [kw] 3 η p [%] 1 3 4 5 Ø 157 Ø 141 1 Ø 134 4 8 1 16 Q[l/s] Q[m³/h] 8 6 4 4 8 1 16 Q[m³/h] Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-4 / 8
Ordering information: Wilo-VeroLine-IPL 1/145-1.5/4 Information for order placements Make Wilo Type VeroLine-IPL 1/145-1.5/4 Art no. 89566 EAN number 416399176 Colour Green Minimum order quantity 1 Minimum order quantity unit PCE Weight (net) kg 7.8 Length (net) mm 55 Width (net) mm 356 Height (net) mm 5 Weight (gross) kg 78.3 Length (gross) mm 79 Width (gross) mm 4 Height (gross) mm 6 Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-5 / 8
Specification texts: Wilo-VeroLine-IPL 1/145-1.5/4 Single-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With forced-flow circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller. Flange with R 1/8 pressure measuring connections. Pump housing and lantern are cataphoretic-coated. Materials Pump housing: EN-GJL-5 Lantern: EN-GJL-5 Impeller: EN-GJL- Pump shaft: 1.41 [AISI4] Mechanical seal: AQEGG Permitted field of application Standard version for operating pressure: 1 bar Temperature range at max. ambient temperature +4 C: -...+1 C (depending on the fluid) Max. ambient temperature: +4 C Pipe connections Nominal flange diameter: DN 1 Flanges (according to EN 19-): PN 1 (PN 16 on request) Flange with pressure-measurement connections: R 1 / 8 Overall length: 5 mm Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI):.4 Pump with max. impeller diameter for determining the MEI: IPL1/175-3/4 Motor/electronics Protection class: IP 55 Insulation class: F Rated current (approx.): 3.3 A Motor efficiency level: IE Motor efficiency: 78.7/81.3/8.8 % Power factor:.79 Nominal motor power: 1.5 kw Nominal speed: 145 rpm Weight Weight approx.: 71 kg Information for order placements Art no.: 89566 Type: VeroLine-IPL 1/145-1.5/4 Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-6 / 8
Specification texts: Wilo-VeroLine-IPL 1/145-1.5/4 Make: Wilo Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-7 / 8
Terminal diagram : Wilo-VeroLine-IPL 1/145-1.5/4 Terminal diagram W U V U1 V1 W1 W U V U1 V1 W1 : Connection diagram delta connection Y: Connection diagram star connection Motor protection switch required on-site. Check the direction of rotation! To change the direction of rotation, exchange any two phases. P 3 kw P 4 kw 3~4 V Y 3~3 V 3~69 V Y 3~4 V L L 1 L3 PE L L 1 L3 PE After removing the bridges, Y- start is possible. Subject to change without prior notice. www.wilo.co.uk 5 Hz 15-8 / 8