T YPE MZ DISTRIBUTION S TANDARD CUTOUT

Similar documents
T HREE-SHOT TYPE MZR F USE CUTOUT

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

S&C Recloser Bypass Disconnects

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

S&C Type XS Fuse Cutouts

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A January 2014

Disconnect & ByPass Switches

S&C Type XS Fuse Cutouts

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Loadbuster Disconnects

Figure 1. HX cutout fuseholders.

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA March 2013

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10A October 2015

Figure 1. HX cutout fuseholders. Positive Interruption

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Cutouts (Standard, Linkbreak, Loadbreak) and Cutout-Arrester Combinations. Catalog 10AA August 2015

JUMPERS & SWITCHING TOOLS

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

NOTE: Because Hubbell has a policy of continuous product improvement, we reserve the right to change design and specifications without notice.

Cutouts (Standard, Linkbreak & Loadbreak) and Cutout-Arrester Combinations U.S. Patent 4,546,341; 6,392,526

34-SDMS-01 SPECIFICATIONS FOR

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

TYPE V CENTER BREAK SWITCH

PRODUCT CATALOGUE. Overhead System

SPECIFICATION BULLETIN

RBA Catalog Numbers and Information

Jumpers & Load Pickup Tools

3.0OVERHEAD TRANSMISSION SWITCHES

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

TYPE BLT DISCONNECT SWITCHES

Specif ications. Minimum Surge Arrester Rating, kv

شركة كهرباء محافظة القدس المساهمة المحدودة

15 kv and 25 kv Thru-Bushings

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

POWER SYSTEMS, INC. CUTOUTS (Standard, Linkbreak & Loadbreak) and CUTOUT-ARRESTER COMBINATIONS

OVERHEAD DISTRIBUTION SWITCHES

OVERHEAD DISTRIBUTION SWITCHES

Technical Specification for Pole Mounted Capacitor Rack

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

M-Force three-phase switch

Technical Specification For Outdoor Substation Harmonic Filter Banks

25 kv Apparatus Bushings

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

M-Force three-phase switch

SF 6 Gas Insulated Load Break Switch

S&C Manual PME Pad-Mounted Gear

GROUP D. Switch & Protective device.

Catalog 14A January 2013

Solid Dielectric, Single Phase Recloser

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

K-Limiter high ampere Companion II fuse

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

Aluminum Vertical Break Switch kv A.

Kuhlman Electric Corporation Volt Instrument Transformers

Easy-On II Terminations

Underground Distribution Switchgear

Figure 1. Kearney Type HX cutout.

Type ICX Outdoor open type cutout

Product Specifications for Aluminum Vertical Break Switches

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

Copper Vertical Break Switch kv A.

Copper Double Break Switch

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

AIR CORE REACTORS. Phoenix Electric Corporation

GENERAL. CONSTRUCTION External

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

Cobra-S. Catalog Cobra-S

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Application guide. Tmax Link OEM UL 891 Switchboard Program

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-

TABAN NIROO CO. DENA POWER LINE INSULATORS

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Solid Dielectric, Single Phase Reclosers

Transcription:

T YPE MZ DISTRIBUTION S TANDARD CUTOUT Page 1 of 7

The Fuse Cutout type MZ was developed to operate in overhead distribution systems rated at 15, 27 and 38 kv grounded systems with 100 or 200 A nominal currents. Especially designed to protect transformers, capacitors, cables or lines. It is robust construction, made of rigorously tested material, will interrupt all faults under the most severe conditions, maintaining mechanical and electric characteristics. The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel. The Fuse Cutout type MZ can be applied on all three-phase system rated at or below the maximum operational rating of the cutout. In highly polluted environments or environments with high levels of salinity, a cutout may be used with a higher nominal rating than that of the system where it is being installed, where the insulator will have a greater leakage distance to ground, allowing for increased safety against discharge. For an even better protection against abrasions, the hardware may be supplied in stainless steel. The fuse cutout type MZ has attachment hooks in aluminum. The Fuseholder has a stainless steel flipper, which associated with a spring doesn t allow the fuse link to be subject to traction forces of over 3 Kgf, especially during closing. This mechanism also allows for high speed fuse link separation. The fuse cutout type MZ allows for the insertion of the fuse tube in a precise manner and always in perfect alignment, due to the large distance between the trunnion pocket. Lower contact, silver-to-silver, provide duel current path, independent of hinge pivot. Stainless-steel back-up springs prevent arcing when tube rises in hinge during recoil. The fuse cutout type MZ may be transformed into a DICONNECT up to 300 A, by simply changing the fuse tube for an electrolytic copper blade. (See Figure 1) Figure 1 The MAURIZIO fuse cutouts designs are tested in accordance with ABNT, ANSI and IEC standards. Page 2 of 7

S PECIFICATIONS System Voltage, kv kv Rating Amperes, RMS to Ground (Minimum) Nom. Max. Cont. Interrupting (60Hz) Inches (mm) Sym. Asym. thru 15 14.4 15 110 15 thru 25 25 27 25** thru 34.5** 25 36 125 150 170 150 170 100 7,100 10,000 10,600* 16,000* 200 8,000* 12,000* 100 5,600 8,000 8,000* 12,000* 100 5,600 8,000 8,000* 12,000* 100 8,000* 12,000* 100 8,000* 12,000* 100 8,000* 12,000* * These units include an arc shortening rod and must be used with removable buttonhead fuse links. 9.4 240 12.6 320 17 432 26 660 17 432 ** Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connect ed capacitor banks in solidly grounded-neutral (multigrounded-neutral) systems. 26 660 Page 3 of 7

KV Dimensions in Inches (mm) A B C D E 110 21.6 (549) 16.1 (409) 12.9 (327) 3.7 (93) 5.7 (144) 125 26.8 (682) 18.8 (478) 13.5 (343) 3.1 (79) 5.7 (144) 150 26.8 (682) 18.8 (478) 13.5 (343) 3.1 (79) 5.7 (144) 170 31.9 (811) 21.5 (547) 14.1 (359) 2.5 (64) 5.7 (144) Page 4 of 7

C HARACTERISTICS 1- Parallel Connector Made of tinned bronze for cables from 8 AWG to 4/0 ACSR. To ease the connection, it can accommodates two conductors with different size in a single connector. Also available in other models. 2- Upper Contact Silver to silver; stainless steel springs offers high contact pressure. 3- Attachment Hooks Used as tool support for energized opening as well as to guide the fuse tube during closing. 4- Fuse Tube Vulcanized fiber covered with fiberglass and painted with a special UV resistant epoxy. 5- Lower Contacts Silver to silver; non ferrous springs offer high contact pressure 6- Toggle-joint Stainless steel construction. 7- Flipper Stainless steel construction; in conjunction with the toggle joint allows, especially during closing, the fuse link to be subject to traction forces of over 3 Kgf; it also allows for high speed fuse link separation. 8- Trunnion Silver plated high strength cast bronze construction; it assists the fuse tube alignment during closing. 9- Insulator High strength porcelain in accordance with ANSI, IEC. Page 5 of 7

S TYLES Thru 15 kv 110 kv 9.4 (240mm) Net Weight (lbs) 12.279 13.227 12.390 Pallet Quantity 66 66 66 Thru 27 kv 125 kv 12.6 (320mm) Net Weight (lbs) 14.925 15.983 15.123 Pallet Quantity 66 66 66 Page 6 of 7

Thru 38 kv 150 kv 17 (432mm) Net Weight (lbs) 19.180 20.238 19.400 Pallet Quantity 48 48 48 Thru 38 kv 170 kv 26 (660mm) Net Weight (lbs) 24.691 26.014 24.912 Pallet Quantity 24 24 24 MAURIZIO & CIA. LTDA. Av. Dr. Abilío Sampaio, 725 - Vila Gustavo 02209-040 - São Paulo - SP - Brasil Tel.: 55-11-2951-1700 - Fax.: 55-11-2981-9566 www.maurizio.com.br - maurizio@maurizio.com.br Page 7 of 7