USER MANUAL. SDI-P Series. PWM Solar Charge Controller. Compatible Models: SDI-P20A SDI-P30A SDI-P40A SDI-P50A SDI-P60A SDI-P70A SDI-P80A

Similar documents
ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

User Manual. Solar Charge Controller 3KW

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

HP Series Smart Solar Charge Controller HP2430/2440/2450/2460 HP4830/4840 UserManual

PWM Charge Controller with LCD Display 30A. User Manual

User Manual Solar Charge Controller 3KW

PWM Charge Controller with LCD Display 10A 20A. User Manual

Instruction of Solar Charge Controller. User s Manual

HP Series Smart Solar Charge Controller User Manual HP2410/HP2420/HP2420-S

Instruction of Solar Charge Controller. User s Manual

itracer-nd series MPPT Solar charge controller with DC load output BEIJING EPSOLAR TECHNOLOGY CO.,LTD. Models: Features:

User Manual Version: 1.4

Instruction of Solar Charge Controller. User s Manual

The Traveler Series: Adventurer

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

LS0512 Solar Charge Controller

EPEVER. LS-E Series. Solar Charge Controller USER MANUAL

CAPSOL. Solar charge controller. New ViewStar series. Models. Features

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

XTRA-N SERIES. New MPPT Solar Charge Controller. Product models XTRA1206N/XTRA2206N XTRA1210N/XTRA2210N XTRA3210N/XTRA4210N.

User Manual. ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller ML V/24V

MPPT Solar charge controller

The Traveler Series: Wanderer

Eclipse Solar Suitcase

LS0512R Solar Light Controller

SMPPT. Solar Charge Controller with Maximum Power Point Tracking. Installation & Operation Manual

20A\30A\40A\50A\60A. Maximum PV(voc) Voltage: DC150V

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Solar Controller / Battery Charger User s Manual

PV Generation System. Solar Charge Controller SPECIFICATION

MPPT SOLAR CONTROLLER FOR MODELS: 20A baterai 12V 24V

Harness the Power of the Sun

The Traveler Series TM : Adventurer

The Traveler Series: Wanderer

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

User Manual. Hybrid PV Inverter. Version: 2.1

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

Installation and Operating Instructions. Solar System Controller ISC3030

30A PWM Solar Charge Controller with LCD Model: PWM30CC-LCD

User Manual. UPower Series. Inverter/charger

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Owner s Manual. Contents GP-PWM-10-SQ

Advanced Hybrid Wind / Solar Charge Controller. User Manual

MPPT Solar Charge Controller INSTRUCTION MANUAL

KC5 PV Charge Controller Instruction Manual

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Duo Battery Charge Controller

P H O T O V O LTA I C

User Manual. Grape Solar ZENITH Series Solar Charge and Load Controller. 12V/ 24V with Auto-Recognition 20A 40A 20A

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

I t n e t l e l l i l g i e g n e t n So S l o a l r a Ch C a h r a g r e g Co C n o t n r t o r l o l l e l r U e s r e s Man an al

Owner s Manual. Solar Controller GP-PWM-30

User Manual. Tracer AN series. MPPT Solar Charge Controller

User Manual. 3kW Hybrid PV Inverter HX-3000

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

Installation and Operating Instructions. Solar System Controller ISC3020

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Maximum Power Point Tracking ML Serial

Solar Inverter Manual

GSM Series MPPT PV Controller. Version 1.0. Manual

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product

Solar Hybrid Inverter SP Brilliant Series

User Manual of MPPT Solar Charge Controller

Operating Manual MP-3739

SCC-MPPT Solar Charge Controller

Ningbo Star Solar Co.,Ltd Tel:(86) Fax:(86)

ML Maximum Power Point Tracking (MPPT) Series. Solar Charge and Discharge Controller User Manual

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Thank you for choosing our product!

1. Introduction OHY1P kW Hybrid Inverter USER MANUAL V2.0

HQST 20A 30A 40A. MPPT Solar Charge Controller. User Manual

Solar charge controller. Manual

SCC-MPPT Solar Charge Controller

Solar Charge Controller

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

User Manual 1KVA-5KVA INVERTER / CHARGER

Solar Charge and Discharge Controller User Manual

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

SCC-MPPT Solar Charge Controller

ORVALDI Solar Infini 5kW

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

Solar Hybrid Inverter SP Initial Series

Steca Solarix PLI. Inverter / Charger with Solar Charge Controller. Installation and operating instructions. Download manual at

Transcription:

SDI-P Series V2.2 PWM Solar Charge Controller USER MANUAL Compatible Models: SDI-P20A SDI-P30A SDI-P40A SDI-P50A SDI-P60A SDI-P70A SDI-P80A High Technology Create A Better Life! 1

Preface Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,use and troubleshooting,etc. Please read this manual carefully before using the product any pay attention to the safety recommendations in it. Contents of this manual are subject to change without notice, and updates will be added in the new version of the user manual. For ease of reference, please take good care of this manual. 2

Contents ============================================= 1. Products Introduction...4 1.1 Product Description...4 1.2 Main Features...5 2. Installation & Operation...6 2.1 Function...6-7 2.2 Dimension...8 2.3 Installation Step...9-11 2.4 Operation...11-13 2.5 controller operate description...14-16 2.6 Remote Communication (optional)...16 2.7 Others...16 3.Attention & Protection... 17 3.1 Attention...17 3.2 Protection...17-19 4.Technical Data...20 5.0 Warranty...21 3

Product Introduction 1.1 Product Description SDI-P series is the solar power system charge controller with high performance and high reliability. SDI-P series charge controller optimize the algorithm of the battery charge and discharge.provide the best possible energy to the PV output and battery storage.system looses to a minimum.the LCD screen will provides more detailed system parameters and display digital meters.and with automatic sleep capability.the lowest quiescent current can be less than 8mA. SDI-P series products use the high-quality components.and through a rigorous quality control and factory test.already got CE certification. Products can have a long-term safe and reliable operation within the definition. PV and Battery both with against reverse protection. All products are equipped with soft start and overload time limit protection, adaptation capacitive load, such as inverters. 4

1.2 Main Features Optimized PWM charging mode.support MCT three-stage charging. 12/24v(20A-40A type),12v/24v/36v/48v (50A to 80A) system voltage. max PV open circuit voltage at 100v Compatible with normal types of batteries(lead-acid,gel or custom) Variety parameters can be modified.(support panel keypad or infrared remote control) Support PV/Battery/Load key parameters display and check. Manual,Light Control or automatic dual period load out can be set Support for RS-485 interface,modbus communication,support for PC remote monitoring (optional) Support USB charge port(5v 1A,optional) Quiescent current can lowest as 8mA Support for external battery temperature sensor(optional) Excellent Radiating design,all-metal shell heat radiating.efficient and artistic 5

Installation & Operation 2.1 Function (1) PV terminal Positive and negative electrode for connecting PV array. (2) Battery terminal Positive and negative electrode connected with battery pack. (3) Load terminal Positive and negative electrode connected with DC load. (4) RS485 terminal Connected with computer or other controllers to realize the remote communication. (5) The terminal of the temperature sensor Connected with the controller temperature sensor that offered, to provide battery data for controller.. (6) USB terminal Provide 5V/1A power supply, can be charged for mobile phones and other devices. (7) Infrared signal sensor Remote infrared communication. (8) Enter or OK button 6

(9) Page down button (10) Page up button (11) LCD screen display Display the operating state of controller, real-time parameters, as well as the realization of human-computer interaction. Also operating settings for the controller. (12) Mounting holes 7

2.2 Dimension SDI-P20A SDI-P30A SDI-P40A SDI-P50A SDI-P60A SDI-P70A SDI-P80A Figure 2.2 Product Appearance 8

2.3 Installation Step a) Type Selection Please strictly follow the system application range.choose the most appropriate products,special attention that the PV side maximum open circuit voltage should not exceed the controller maximum allowable voltage.the SDI-P Series products can stable operation in a long-term at rated current.and can also withstand a certain amount of overload.but should be use to avoid overload operation in a long time. b) Installation Way SDI-P Series controller should be perpendicular installation.to ensure that the thermal resistance of the wind through the radiator is minimum, the controller external upper and lower ends should at least keep 15cm space for airiness c) Battery Connection Please select the connect cable diameter according to the controller input/output maximum current value.and it is better select the thicker cable.the wiring length as short as possible to avoid too long or too thin.in order to reduce the cable loss and cable temperature. Firstly,connect the battery,after correctly connection.the LCD display will light up within 2 seconds.and enter self-test,will display the automatic identification system voltage value.if the voltage which display does not match with the actual system voltage.please enter manually set state to adjust it.typically,as long as the battery voltage is in the range shown in the following table,the controller can correctly recognize the system voltage without manually 9

setting. 12V system DC 7V-17V 24V system DC 18V-28V 36V system DC 32V-40V 48V system DC 42V-60V Noted.:please use insulating screw driver when wiring, to ensure the connection is secure After battery connection,the user should set up the battery type and charge way.sdi-p series with default battery type at lead-acid battery,three stage charging. d) Battery temperature detection cable Connection Battery temperature detection,mainly in order to compensate for the battery temperature characteristics of the battery at different temperature, normal is -5mV/ /2V, in the case of less demanding system can not be installed. A standard temperature Sensor(DS18B20) for SDI-P series. e) Solar Panel Connection Make sure the PV voltage in the correct range before wiring, to avoid damage to the controller. After connecting the PV, LCD screen will display the status of PV solar panel. f) Load Connection Before load connected, turn off it. If you need control the load work,please connect it at controller load port. SDI-P controller defaults to directly open load. Users can set the controller work mode as needed. 10

In many cases, users also can directly connected the load to the battery, but at this time,the current between load and battery has not be detected & controlled by the controller. We suggest user installed external fuse or breaker to avoid excessive inrush current blown the fuse which built-in. SDI-P series controller can be soft-start and provides a larger starting current to the load, especially for the capacitive load equipment such as inverters, switching power supplies,motors etc. 2.4 Operation After wiring, SDI-P controller will display system status and parameters and enter the normal operating state. Once abnormal, the fault code will be displayed. 1, LCD panel setup Instructions SDI-P series comes standard with large LCD screen and 3 buttons. You can set various functions and parameters through the panel keypad. also supports infrared remote control(rc-3)to setup. After battery connected, the LCD will enter normal working status in a few seconds, the message shown in Figure 2.4.1. Figure 2.4.1 LCD screen display 11

In addition to panel displays battery type,work model,charge and discharge status. The user can press the up or down button to view the parameters of the controller (battery voltage, load current,pv current, the charge/discharge capacity of last week) In manual mode, press the "OK" button to on/off the load. Note: When Controller fails,the error icon flashes and an error code display on the LCD screen.user can press up or down button to view details. Table of Error Code E101 load short-circuit E203 Battery Over-temperature E102 load Overload E301 PV over-voltage E201 Battery over-discharge E302 PV Over-current E202 Battery Over-charge E401 Controller over-temperature 2,Parameter Setting Press "OK" button Continue for three seconds, the controller will enter the setup mode.as Figure 2.4.2 Figure2.4.2 LCD screen display 12

The user can press up or down button to select the controller parameters which need be modified.then press ok to set it.when it flashes data can be modified. After edited press ok again.it will stop flash.data be saved. After setting,press ok in 3 seconds or no operation in 50s,it will automatic return back to the main page. Items FUN parameter LOAD 0 Load work model LOAD 1 1 st period time(auto mode ) LOAD 2 Morning period time (auto mode) PV 3 Light control voltage PV 4 Light control delay time(minute) BAT 5 Battery type BAT 6 System Voltage Note:following parameter only for battery type at DIY BAT 7 Over voltage BAT 8 Over discharge voltage BAT 9 Over discharge return voltage BAT b Boost charge voltage BAT F Float charge voltage Table of Parameter Selection 13

2.5 Controller Operate Description 1, Charge after the battery type be set, SDI-P series controller will be automatic running,without human intervention. In special cases, the user also can adjust parameters. The controller uses three-stage charging method provides a fast, efficient, and safe battery charging. See the following chart Figure 2.5 Charging of lead acid or gel battery: The controller manages battery charging based on specified charging curves for different types of cells and settings. If the cell type defined in the controller is lead acid or gel battery, the whole charging process includes three phases: Fast charge stage, equalize charge stage, and float charge stage. 3.1.1 Gel/lead acid battery Trickle pre-charge stage: at the beginning of charging. If the battery voltage is too low, in order to protect the battery, to avoid large 14

current impact caused damage to the internal structure of the battery. The controller will charge battery in a small current. And will enter fast charge stage after the battery voltage be some improvement. Fast charge stage: The battery voltage has not reached the setting, and the controller will provide the maximum solar power to charge the battery. During Fast charging, the solar panel and the battery are connected directly. The voltage of the solar panel is clamped at the battery voltage. Equalize charge stage: When the equalizing charge voltage is reached, pulse width modulation (PWM) is activated. When the battery voltage reaches the setting, the controller continues to adjust battery voltage to maintain it at the setting and prevent over-charging of battery.and this stage will keep 2hours then enter Float charge stage. Float charge stage: In this phase, the battery requires no further power, but the controller still provides weak charging to meet power consumption needs of small loads and to make up for power consumption by the battery itself. In this way, the battery is always kept at a saturated state for a longer service life. 15

2,Discharge SDI-P series controllers can be used in unattended mode, run automatically according to the set operating mode. The controller with 3 work modes. A) Light Control mode: when there is no sunlight, the PV voltage drops to light control starting value.load will running after server minutes. when the sun rise, the PV voltage will rise to light control voltage start point, the load output will be off. B) Manual mode: it will manual on or off by press OK button or RC-3 infrared remote control. C) Auto mode: This mode with light control + time delay function.there are 2 period working time can be set..after Sun set, load output will be on auto and work from 1st period.then,load will cut off at the end of 1 st period.before sun rise,it will work in 2nd period,and cut off when sun rise. 2.6 Remote Communication (optional) SDI-P series controllers with optional 485 communication interface for remote communication through MODBUS protocol, in order to change the controller operating parameters and status, monitor status of the controller. 2.7,Others A. Additional interfaces(optional) SDI-P series controller configuration USB interface is optional interface, which Supports load output capability of USB-5V1A. B. Battery Temperature Sensor(optional) SDI-P series controller configure an external battery temperature sensor DS18B20. 16

Attention & Protection 3.1 Attention SDI-P series charge controller heat dissipation through the bottom radiator,please ensure good ventilation when vertical installed according to the best air duct,when controller work in a big current.the radiator may with a high temperature.please careful not to touch the radiator to avoid burns. SDI-P series already built in over-current fuse of the battery charge and discharge.but we still suggested that user configure as appropriate effective fuse and circuit breaker switch according to the system case. SDI-P series charge controllers all with TVS lightning protection and surge protection at the access terminal.but such protection is limited.when use in a large-scale system,we suggest set more effective lightning and surge protection device separately. When use in a complex electrical environment.we suggest you make a appropriate ground connection for the system. When connect battery and PV panel.please note the correct wiring and protection.to avoid wrong wiring and short-circuit.wiring too long,it will have a greater voltage drop and line loss,and cause excessive surges. 3.2 Protection The controllers have the best protection features to protect the safety and reliability of the controller. PV array input short circuit,over voltage,over current,reverse polarity protection. Battery over charge,over discharge,reverse,polarity, 17

over-temperature protection. Load short circuit,overload time limited protection(support for capacitive load) Controller over temperature protection A,Over-discharge protection the battery during discharge, more than the termination voltage of the battery discharge, it may cause pressure within the battery while also continue to discharge, positive and negative active material damage was reversible, so that the battery capacity to produce significantly reduced. When the battery reaches over-discharge protection voltage, the controller into the over-discharge protection state, turn off the load output, protect the battery will not be damaged. When the battery charge is higher than the over-discharge voltage returns, the controller exits over-discharge protection, restore power to the load. B, over-voltage protection When the battery voltage is increased to over-voltage point, the controller enters the state of overcharge protection, turn off the load output, in order to protect the load is not damaged. When the battery voltage is lower than over-voltage, the controller exits over-voltage protection, restoration load output. C, Overload protection When the load current exceeds the rated current, will enter the overload time limited protection mode, to avoid damage to the controller. When the load current is less than 1.25 times the rated current, the controller may overload long run, but by the controller temperature protection control. 18

D,overload time limited protection The load current is equal to 1.25 times the rated current with working for 120s,load disconnect output; 1.5 times for 10S,2 times overload protect immediately. E,Load Fault protection If load short circuit, the controller automatically protection, the Controller will detect whether the load fault exclusion. If the fault persists more than 5 times, the controller will off the load output. F,Over-temperature protection When the controller itself temperature is too high (> 85 ), in order to avoid damage, the controller will cut off the load output or charging, stop working, and so on after the temperature dropped to 65, and then restarting the load or charge. G,Temperature sensor damage fault protection When the temperature sensor short circuit or damage, the controller will default to work at 25, in order to avoid erroneous temperature compensation for damage to the battery. H, Battery polarity protection Battery reverse polarity, the controller will not be damaged, will continue normal operation after correcting wiring errors. I, Light battery polarity protection the photovoltaic cell polarity reverse, the controller will not be damaged, will continue normal operation after correcting wiring errors. 19

Technical Data Model SDI-P 20A SDI-P 30A SDI-P 40A SDI-P 50A SDI-P 60A SDI-P 70A SDI-P 80A Rated charge current 20A 30A 40A 50A 60A 70A 80A System voltage 12/24V 12V\24V\36V\48V PV max open circuit voltage 100V Rated load current 20A 30A 40A 50A 60A 70A 80A Direct charge voltage GEL: 14.4V, LEAD ACID: 14.2V, Custom: 9~17V (12V) Boost charge voltage Float charge voltage Over-discharge return voltage Over-discharge voltage GEL: 14.8V, LEAD ACID: 14.6V, Custom: 9~17V (12V) GEL / LEAD ACID: 13.8V, Custom: 9~17V (12V) GEL / LEAD ACID: 12.6V, Custom: 9~17V (12V) GEL:11.0V,LEAD ACID: 11.1V, Custom: 9~17V (12V) Loss Load dual period control External temperature sensor Temperature compensation Communicate interface USB interface 15mA(12V); 10mA(24V); 8mA(48V) Auto DS18B20(optional) -5mV/ /2V RS485,MODBUS(optional) 5V 1A(optional) Dimensions 157x90x43mm 186x107x67mm Terminal Connection 6 AWG 16mm 2 AWG 25mm Net weight 510g 1025g Protection class LCD oprate temperature range Work temperature range IP30-20 ~+70-25 ~+55 Humidity 95% N.C. 20

Warranty Warranty Card Product Name Product Model Serial number Date of purchase: Date Month Year Company Name: Contact: Address: Tel: 1. The product warranty period is three years since factory. 2. During the warranty period, any problem caused by normal use under the user manual (determined by the controller factory), reparation is free of charge. 21