Zirconia Oxygen Probe

Similar documents
ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

Combination ph/redox (ORP) Sensors

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Combustion Gas Analysis

Katharometer Power Supply Units

Combination ph/redox (ORP) Sensors

In Situ Oxygen Transmitter For High Sulfur Environments

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Analytical Instruments Two-Electrode Conductivity Sensors

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

Endura AZ20 oxygen monitor Combustion gas analysis. Superior technology and quality from the world leader in oxygen measurement

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

ABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement

In Situ Oxygen Transmitter

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

Instrumentation for the power industry. Enhanced plant performance, efficiency, reliability. ABB Instrumentation

O 2 CO CO 2 NO NO 2 NO x

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

In Situ Oxygen Transmitter

In Situ Oxygen Transmitter

R Series Electromagnetic flowmeter Reduced-bore flow sensors. The smart solution for remote applications

Electromagnetic Flowmeters

HygienicMaster Electromagnetic Flowmeter. The clean choice for hygienic applications. ABB Instrumentation

OCX 8800 Oxygen/Combustibles Transmitter

Field IT Electro-Magnetic Flowmeters Sensors

A type Ejectors (in line) Dimensions and weights

Transmitting Transducer. Gas/Air Velocity Range:

In Situ Oxygen Transmitter

SERVOTOUGH Fluegas Exact (2700)

Electro-Magnetic Flowmeters Sensors MagMaster MFE

In Situ Oxygen Transmitter for Hazardous Area Applications

Digital ph transmitter

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

In Situ Oxygen Transmitter

Battery-Powered Flow Transmitter

Micro Motion 7827 Digital Viscosity Meter

Model 7A00 7A00 - TB TECHNICAL BULLETIN. Detonation Flame Arrestor

Describe Flame Arrestor Operation and Maintenance Human Development Consultants Ltd.

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Data Sheet 10/ EN November 2004

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Micro Motion Model D and DL Coriolis Flow and Density Meters

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

Model 6A00 TECHNICAL BULLETIN 6A00 - TB Inline Deflagration Flame Arrestor

CATALOG OF REPLACEMENT PARTS

Rosemount TM OCX 8800 Oxygen and Combustibles Transmitter

World Class 3000 Oxygen Analyzer with IFT 3000 Intelligent Field Transmitter

Digital ph transmitter

Conductivity Measuring Cells ConduMax W CLS 19

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

MULTIFIRE. High temperature dual fuel burner

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

THC Heated FID 3-300A

Micro Motion 7829 Viscomaster Series Accessories

Combination ph/redox (ORP) Sensors

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

available in battery up to 4 units for a total of 560 kw

Industrial flue gas probes. Instruction manual

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

OCX 8800 Oxygen/Combustibles Transmitter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

World Class 3000 Oxygen Analyzer with HPS Heater Power Supply Field Module (for use with Existing Signal Conditioning Electronics)

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Model Q45H/ Residual Chlorine Monitor...

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

PRODUCT CONFORMITY CERTIFICATE

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

Micro Motion F-Series Coriolis Flow and Density Meters

SUBMITTAL COVER SHEET

Oxygen Probe Troubleshooting Guide Marathon Monitors, Inc.

Instrumentation for the pulp and paper industry Enhanced performance, efficiency, reliability

Sarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control

4. Sensors and Switches

Differential Pressure Gauges (701P Series)

TORRIX Magnetostrictive level sensor

Armstrong In-Line and Insertion Vortex Flow Meters

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Flame arresters 4301A/4319A ATEX Approved

FUEL OIL BURNERS. By Mark Butterfield March 09

AquaMaster3 Electromagnetic flowmeter

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Instrumentation for the oil and gas industries Enhanced production performance, efficiency, reliability

OCX 4400 OXYGEN/COMBUSTIBLES TRANSMITTER

ABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

The PMI Dilution Probe for In-Situ Sample Conditioning of Stack Gases

SPECIALISTS IN PRESSURE, TEMPERATURE, LEVEL, FLOW, GAS DETECTION, CALIBARATION & FLUID POWER INSTRUMENTATION

NO X EMISSIONS FROM HEAVY FUEL OIL BOILERS

F-2600 SERIES INLINE VORTEX FLOW METER

Differential Pressure - Primary Flow Element Wedgemeter II Series WM: C/F/P

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Transcription:

Data Sheet SS/ZFG Issue Zirconia Oxygen Probe ZFG Series Environmental Certification MCERTS SIRA Certificate MC99000 Combustion monitoring control true wet measurement of net excess oxygen in situ measurement Low cost-of-ownership fully site-serviceable probe Versatile four insertion lengths: 0.4 m (6 in),.0 m (9 in),.5 m (58 in) and m (78 in) flame trap for gas-fired boiler applications soot filter as standard fast response options SIRA ML9900 /00 SIRA Certificate N o ML9900 /00 Superior technology and quality from the world leader in oxygen measurement

ZFG Series SS/ZFG Issue Introduction The ZFG Flue Gas Oxygen Probe is one of the most advanced in the world. A simplified design makes all the component parts easily accessible and field serviceable. This innovative probe construction gives the ultimate system flexibility while retaining all the features, benefits and reliability of the previous generation. The in situ probe is inserted directly into the boiler smoke box, or flue duct, eliminating the need for high-maintenance costly sampling installations. Operating in the process temperature range of 0 to 600 C (68 to F) the system gives true wet analysis of net excess oxygen in combustion gases. When the probe is fitted with the standard flame arrester and mounted in an application as shown in the installation instructions (Section ) all parts of the probe that are wetted by the measured gas are safe against causing ignition of the gases. This applies to all Group IIB gases with ignition temperatures below 00 C which generally includes all conventional combustion fuels. This makes the probe completely safe for continuous use even through 'startup' and 'flame out' conditions without the need for power down interlocks. Installation and commissioning are particularly easy and the level of in-service maintenance is extremely low. Principle of Operation The detector cell is constructed from stabilized zirconia featuring integral platinum electrodes and is specific to oxygen. Air is supplied to the internal (reference) electrode to provide a constant partial pressure of oxygen while the measured gases are in contact with the outer electrode, producing a potential proportional to O concentration. The Probe The zirconia probes, constructed from 6 stainless steel, house a ceramic dust filter, flame trap, detector cell, cell heater and thermocouple. Wiring and reference-air tube between the electronics unit and the probe can be carried in a single flexible conduit up to 0 m (66 ft) in length. Standard options include dual conduit to separate signal/power cables and IP65 rated versions. For other non-standard options contact ABB. The standard probe insertion lengths are 0.4,.0,.5 and.0 m (6, 9, 58 and 78 in) and fixing to the duct or smoke box is by means of a drilled flange. Standoff fixings can be used to reduce the insertion length for smaller ducts. An alternative / in screwed bush is also available for fixing the 0.4 m (6 in) probe to the duct or smoke box. A Deflector Plate can be fitted if excessive dust flows are experienced in the flue. All components of the probe are easily removable and can be replaced on-site without the use of special tools or bonding agents. Replacement of the zirconia oxygen sensor can be made without the need for recalibration of the electronics unit. A calibration gas inlet port is fitted to the probes to enable accuracy checks to be made without removal of the probes from their mountings. Where a faster response is necessary the probe can be supplied with a fast response cell adaptor that replaces the filter and flame arrester. Clamp Screw Ceramic Filter Probe Gas Flow Deflector Plate Deflector Plate fitted to ZFG Zirconia Oxygen Probe

ZFG Series SS/ZFG Issue Probe Construction Standard Cell Flow-through Cell Thermocouple Leads Heater Zirconia Cell Porous Ceramic Filter Thermocouple Leads Heater Zirconia Cell /8 in. BSP Sample outlet Thermocouple Thermocouple Reference Air Electrode Contact Flue Gas Reference Air Electrode Electrode Lead Test Gas Tube Inner Electrode (Reference) Outer Electrode (Measuring) Flame Arrester Sample Electrode Inner Electrode Outer Electrode inlet 'O' Ring Applications include: Industrial boilers, all fuel types Utility boilers, all fuel types Application: The Flow-through cell adaptor enables the 0.4 m (6 in) probe to be used as an extractive (dry) O analyzer system. Recovery boilers Waste incinerators Fast Response Cell Thermocouple Leads Heater Zirconia Cell Test Gas Line Thermocouple Reference Air Electrode Electrode Inner Electrode Outer Electrode Applications include: Industrial boilers, clean fuels only Utility boilers, clean fuels only Note. If protection against ignition of flammable gas mixtures during flame-out conditions is required when using the fast response adapter two methods of protection can be implemented: Using the burner flame-out alarm, to cut off the probe power supply through a lock-out mains switch. Using the burner flame-out alarm to apply 'calibration test gas' as a purge to prevent flammable gases reaching the hot sensor. Test gas should be at l/min and have % O (air) or less with nitrogen balance.

ZFG Series SS/ZFG Issue Specification General Calibration (in situ) One point using clean air Two point using certified test gas and air Flue temperature 0 600 C (68. F) at 0 C (68 F) Pressure Suitable for all normal positive or negative flue pressures Dimensions See Overall Dimensions on Page 6 Probe fixing Flange (or / in NPT screwed fitting for ZFG 0.4 m [6 in]) Probe insertion 0.4,.0,.5 or.0 m (6, 9, 58 or 78 in) Flange options Note. The Flange types listed are NOT pressure retaining. 0.4 m (6 in) ZFG Standard 6.0 ±0.4 mm thick x 0.0 ± mm dia. 6 holes 7. mm dia. equispaced on 80.0 ±0. mm PCD.0,.5 and.0 m (9, 58 and 78 in) ZFG Standard.0 ± mm thick x 65.0 ± mm dia. 6 holes.5 ±0.5 mm dia. equispaced on 40 mm PCD Rosemount/Westinghouse Model equivalent 6.0 ±0.4 mm thick x 7.0 ± mm dia. 4 holes 9.5 mm (0.75 in) dia. equispaced on 99.0 ±0. mm PCD ANSI B 6.5 ( in) 50 lb.0 ± mm thick x 85.0 ±0.5 mm dia. 4 holes 8 mm dia. equispaced on 45.0 ±0. mm PCD DIN 50 Part DN605 PN 6, 5 and 4.0 ± mm thick x 5 ±0.5 mm dia. 4 holes 0.0 ±0. mm equispaced on.0 ±0. mm PCD Cable length 6 m, 0 m, 5 m and 0 m (0 ft ft, 49 ft or 66 ft) fitted. For 5 m and 0 m options (49 ft and 66 ft) contact ABB. Maximum cable length between the probe and the electronics unit 00 m (8 ft) using EXFG/094 signal cable and EXFG/095 power cables. Probe weight 0.4 m (6 in) 6 kg (. lb) [including 6 m (0 ft) cable].0 m (9 in) 0.8 kg (.7 lb) [including 6 m (0 ft) cable].5 m (58 in).6 kg (5.5 lb) [including 6 m (0 ft) cable].0 m (78 in).5 kg (7.5 lb) [including 6 m (0 ft) cable] Measuring Range Response Range Typical response to introducing test gas < 0 s to t90 (less than 0 s to 90% of step change) Probe response to process gas is application and probe configuration dependent Reference gas Clean, oil-free air. Flow rate 50 to 000 cc/minute Construction 6 stainless steel and ceramic Thermocouple NiCr/NiAl EN 60584. PE4 Type K Insertion length 0.4 m,.0 m,.5 m or.0 m (6 in, 9 in, 58 in, 78 in) Protection class Meets requirements of NEMA 4X/IP65 Environmental data Storage 5 C to 55 C ( to F) Up to 95 % humidity (non condensing) JIS B 8 DN65 5K.0 ± mm thick x 55.0 ±0.5 mm dia. 4 holes 5 equispaced on 0.0 ±0. mm PCD 4

ZFG Series SS/ZFG Issue Flanges & Fittings (Dimensions in mm [in]) Note. The flange types listed are NOT pressure retaining. Standard Mounting Flange 0.4 m (6 in) Probe Mounting Flange mates with ANSI B6.5 ( in) 50 lb (All Probes) 6 holes 7. Ø (0.9) on 80 (.5) p.c.d. 6 (0.5) 4 holes 0 (0.78) on (4.7) p.c.d. (0.47) 0 (.97) Dia. 5 (6) Standard Mounting Flange.0 m,.5 m &.0 m (9 in, 58 in & 78 in) Probes JIS Mounting Flange mates with JIS B8 DN65 5K (all Probes) 6 holes.5 (0.5) on 40 (5.5) p.c.d. (0.47) 4 holes 5 (0.6) on 0 (5.) p.c.d. (0.47) 65 (6.5) 55 (6.) DIN Mounting Flange mates with DIN 50 Part DN65 PN 6, 5 and 40 (all Probes) Model Mounting Flange 0.4 m (6 in) Probe 4 holes 8 (0.7) on 45 (5.7) p.c.d (0.47) 4 holes 9.5 (0.7) on 99 (.9) p.c.d. 6 (0.5) 85 (7.8) 7 (5) 5

ZFG Series SS/ZFG Issue Mounting Plates Dimensions in mm (in) Six M6 studs equispaced on 80 p.c.d. 7 (0.7) Six M0 studs equispaced on 40 p.c.d. 0 (0.80) 60 (6.0) 0 (0.80) 60 (6.0) 0.4 m (6 in) Probe 6 (0.6) 0 (0.80).0,.5 and 0 m (9, 58 and 78 in) Probes (0.) Overall Dimensions Dimensions in mm (in) 50 (5.9) 90 (7.48) nom. 400 (5.74) 6 (.44) 6 (.44) dia. 5 (5.98) 0.4 m (6 in) Probe For Flange Dimensions see Page 5 6 (.44) dia..0,.5 and.0 m Models (9, 58 and 78 in) 40 (6.4) nom. 000, 500 or 000 (9.7, 59.05 or 78.74) 6

ZFG Series SS/ZFG Issue Ordering Information ZFG Zirconia Oxygen Probe ZFG X X X X X X X X X Insertion length 0.4m (6 in).0m (9 in).5m (58 in).0m (78 in) Flange Type Standard DIN ANSI JIS Model Special Conduit Entry Type Quantity Length *Available for Standard cell only. Ordering Example Transmitters 0 mm (0.78 in) / in NPT None One standard Two standard One IP65 Two IP65 None 6 m (0 ft) 0 m ( ft) Cell Standard cell Flow-through cell Fast response cell Flame Arrester None Flame arrester* Reference Air Internal External Mounting Plate Assembly None Standard (0.4 m [6 in] probes) (ABB standard flange only) Standard (long probes) (ABB standard flange only) / in NPT 0.4 m (6 in) probe only ZFG Zirconia Oxygen Probe ZFG Insertion length.0 m (6 in) Flange type standard Conduit entry type 0 mm (0.78 in) Number of conduits two Conduit length 6 m (0 ft) Cell type standard Flame arrester fitted Reference air internal tubing (within conduit) Mounting plate assembly standard (long probes) For details of transmitters for use with the ZFG probe see data sheets SS/ZMT and SS/ZDT/FG. 4 4 5 9 0 4 0 0 0 9 7

ZFG Series ABB has Sales & Customer Support expertise in over 00 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (09.08) ABB 008 SS/ZFG Issue ABB Limited Oldends Lane, Stonehouse Gloucestershire GL0 TA UK Tel: +44 (0)45 8666 Fax: +44 (0)45 8967 ABB Inc. Analytical Instruments 976 S. Virginia St., Ste. E Reno, Nevada 895 USA Tel: + 775 850 4800 Fax: + 775 850 4808