DIESEL GENERATOR SET MTU 16V4000 DS2500

Similar documents
DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 20V4000 DS3600

KVA KW KVA KW

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET DG00660D5

POWER MODULE MTU 16V4000 DS2560

KVA KW KVA KW

KVA KW KVA KW

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Standby Rating 220/ / / / / /

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

STANDBY 200 ekw 250 kva

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

220 to volts. Electronic unit injection

Specifications. 3406C Generator Set Electric Power

Voltage 220 to or 1800 RPM

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

Continuous, Prime, Standby, Mission Critical

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Generator Set Specifications 60 ekw (75 kva)

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Generator Set Specifications 100 ekw (125 kva)

Part III : Technical Specification POS C)

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

DIESEL GENERATOR DATA SHEET

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

Model NA 2 L

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

Transcription:

DIESEL GENERATOR SET MTU 16V4000 DS2500 380V 11 kv/50 Hz/Standby Power with overload/ta-luft Optimized MTU 16V4000G63/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Low fuel consumtion - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certifi ed to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Power Rating - System ratings: 2000 kva - 2350 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 85% load factor - Verifi ed product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Circuit breaker/power distribution - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system - Exhaust system - Mechanical and electrical driven radiators - Medium voltage alternators // Emissions - TA-Luft optimized // Certifications - CE certifi cation option

2 / / / MTU 16V4000 DS2500 / 50 Hz / 380V - 11kV APPLICATION DATA ➀ // Engine Manufacturer MTU Model 16V4000G63 Type 4-cycle Arrangement 16V Displacement: l 76.3 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1500 Engine governor ADEC (ECU 7) Max power: kwm 1965 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 20 l/hr g/kwh At 100% of power rating: 516.1 218 At 75% of power rating: 378.2 213 At 50% of power rating: 252.1 213 // Liquid Capacity (Lubrication) Total oil system capacity: l 300 Engine jacket water capacity: l 175 Intercooler coolant capacity: l 50 // Combustion Air Requirements Combustion air volume: m 3 /s 3.3 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 68.5 Coolant flow rate (LT circuit): m 3 /h 30 Heat rejection to coolant: kw 830 Heat radiated to charge air cooling: kw 500 Heat radiated to ambient: kw 90 Fan power for mech. radiator (40 C): kwm 70 // Exhaust System Exhaust gas temp. (after turbocharger): C 495 Exhaust gas volume: m 3 /s 7.9 Maximum allowable back pressure: mbar 85 Minimum allowable back pressure: mbar 30 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.

3 / / / MTU 16V4000 DS2500 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) Generator model Voltage TA-Luft optimized 40 C/400m without radiator with mechanical radiator with electr. driven radiator kwel kva* AMPS kwel kva* AMPS kwel kva* AMPS Marathon 744RSL7092 380 V 1720 2150 3267 1720 2150 3267 1680 2100 3191 (Low voltage 400 V 1800 2250 3248 1760 2200 3175 1760 2200 3175 marathon standard) 415 V 1680 2100 2922 1680 2100 2922 1600 2000 2782 Marathon 1020FDL7093 380 V 1720 2150 3267 1720 2150 3267 1680 2100 3191 (Low voltage 400 V 1800 2250 3248 1760 2200 3175 1760 2200 3175 marathon oversized) 415 V 1680 2100 2922 1680 2100 2922 1600 2000 2782 Leroy Somer LSA 51.2 VL95 380 V 1880 2350 3570 1800 2250 3419 1800 2250 3419 (Low voltage 400 V 1880 2350 3392 1800 2250 3248 1800 2250 3248 Leroy Somer) 415 V 1880 2350 3269 1800 2250 3130 1800 2250 3130 Marathon 1020FDH7099 11 kv 1840 2300 121 1800 2250 118 1800 2250 118 (Medium volt. marathon) Leroy Somer LSA 53.1 UL85 11 kv 1880 2350 123 1800 2250 118 1800 2250 118 (Medium volt. Leroy Somer) * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation Governor-electronic isochronous Common rail fuel injection TA-Luft optimized engine // Generator NEMA MG1, BS5000, ISO, DIN EN and IEC standards Self-ventilated Superior voltage waveform Solid state, volts-per-hertz regulator No load to full load regulation ±0,25% voltage regulation no load to full load Brushless alternator with brushless pilot exciter 4 pole, rotating fi eld Sustained short circuit current of up to 250% of the rated current for up to 10 seconds (marathon generator) Sustained short circuit current of up to 300% of the rated current for up to 10 seconds (Leroy Somer generator) Marathon low voltage generator Leroy Somer generator Oversized generator Medium voltage generator Represents standard features Represents optional features

4 / / / MTU 16V4000 DS2500 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Mechanical radiator Electrical driven front-end cooler Jacket water heater // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) Automatic mains failure operation with ATS (V3a) Automatic mains failure operation incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) Automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator Protection Functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Differential protection with multi-finction protection relay Modbus RTU-TCP gateway // Circuit Breaker/Power Distribution 3-pole circuit breaker 4-pole circuit breaker Manual-actuated circuit breaker Electrical-actuated circuit breaker Stand-alone solution in seperate switch box // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Switchable fuel filter with water separator Seperate fuel cooler Fuel cooler integrated into cooling equipment // Starting/Charging System 24V starter Starter batteries Battery rack & cables Battery charger Represents standard features Represents optional features

5 / / / MTU 16V4000 DS2500 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Exhaust silencer with 10 db(a) sound attenuation Exhaust silencer with 30 db(a) sound attenuation Exhaust silencer with 40 db(a) sound attenuation Y-connection-pipe Represents standard features Represents optional features

6 / / / MTU 16V4000 DS2500 / 50 Hz / 380V - 11kV WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 5090 x 1836 x 2330 mm 12893 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA NO x + NMHC CO PM 1700 300 50 All units are in mg/nm 3 Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided refers to ISO standard ambient conditions (25 C and 100m above sea level). The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation. RATING DEFINITIONS AND CONDITIONS // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO-3046-1, BS 5514 and AS 2789. Average Load Factor: 85%. Operating hours/year: max. 500. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation distributor for temperature derations. Rated power is available up to 40 C and 400m above sea level. Subject to change. 3238821 Edition 01/14 ENC 2014-07. Materials and specifications subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com