Powered by Dongfeng Cummins 4B Series Engine. Genset Prime Power Range: 27kw-80kw. Basic Characteristics of Diesel Generator Set

Similar documents
Powered by Cummins K38 Series. Genset Standby Power :820KW. Basic Characteristics of Diesel Generator Set

WPS20/S EP Series. Features:

WPS60/S EP Series. Features:

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

WPS350/S EP Series. Features:

WPS250/S EP Series. Features:

GMS100C/S EC Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

GMS350C/S EC Series. Features:

GMS200C/S EC Series. Features:

1 / Genset general description

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Technical specification

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

23 KW / 29 KVA POWERED by

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

PPU Diesel Power 50/60Hz Containerized Generator Set

DIESEL GENERATOR DATA SHEET

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

45 KW / 55 KVA POWERED by

300 KW / 375 KVA POWERED by

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Powered by Cummins Model:YN-95C

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set

DIESEL GENERATOR SET MTU 12V1600 DS660

70 KW / 90 KVA POWERED by

64 KW / 80 KVA POWERED by

1800 KW / 2250 KVA POWERED by

Voltage adjusting range % Voltage stabilization time(100% load sudden reduce) 3. Voltage fluctuation rate: Frequency volatility ±0.

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Diesel Generating Set. Generator Ratings

CGT Stamford UCI 274 E1

FE - C KW / 650KVA 600KVA

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

Better Soundproof, Better Life!

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

2000 KW / 2500 KVA POWERED by

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

APD-ULJ250. Standby Power

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

Diesel Generating Set

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

1000 KW / 1250 KVA POWERED by

500 KW / 625 KVA POWERED by

28 KW / 28 KVA POWERED by

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

1 / Genset general description

TPD2250H6.3 TECHNICAL DATA

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

60 KW / 75 KVA POWERED by

130 KW / 165 KVA POWERED by

80 KW / 100 KVA POWERED by

600 KW / 750 KVA POWERED by

GMS800C/ Features:

700 KVA / 550 KW POWERED by

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

DIESEL GENERATOR SET MTU 10V1600 DS500

55 KW / 70 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

CUKUROVA GENERATOR SYSTEMS

204 KW / 254 KVA POWERED by

PGKT / / / / / / / / / / / /

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

PGDLS352KW 380/ / / / / / / / /

Rental Power QSB7 series engine

640 KW / 800 KVA POWERED by

GMP80PX/ Features:

PGDLS / / / / / / / / /

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

Dual Frequency Diesel Genset

Diesel Generating Set

EC series GMS30CS-AU 50

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

APD-NG400. NG Standby Power

Diesel generator set QSX15 series engine

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

DIESEL GENERATOR SET MTU 18V2000 DS1400

Super Silent, Superior Life!

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

DS100C6S. 2 Years or 2000 Hours Warranty. Power Your Dream! Enclosed structure, Small in size, High safety, Easy installation and operation

Transcription:

Powered by Dongfeng Cummins 4B Series Genset Prime Power Range: 27kw-80kw Basic Characteristics of Diesel Generator Set All series powered by Dongfeng Cummins engine, modern technique, dependable performance,high combustion efficiency and low fuel consumption, long time continuous running, long working life. Conform to the standard of IS03046. All series adopt alternator of Stamford / Marathon/ Faraday/Engga; Excellent excitation characteristics, Ensure that the genset can withstand high power load moment, small Voltage fluctuation, quickly recover. Conform to the standard of GB755,BS5000, IEC34-1,CSA22.2,AS2359. Controller System All series use automatic Powertec GC6110 as controller, Integrating digital, intelligent, network technology,use for a single diesel generator set automation and monitoring system,implement a automatic starting/stopping,the data measured, Alarm protection function of the genset. Radiator Standard 40 ambient temperature online radiator, Closed water circulation cooling system, ensure the rated power output of under high temperature environment. Steel welding base, inbuilt shock absorber Inbuilt shock absorber, perfect shock absorption performance, Easy installation and transport No need to install shock pad on the connection of base foundation and fixed. The performance parameters of the diesel generator set 230/400VAC,60HZ 0.8PF Three phase four wire output (Electronic speed) Frequency drop 3% Voltage modulation 0.3% The steady state frequency 0.5% The steady state voltage deviation ±1% The transient frequency deviation +10% -7% The transient voltage deviation +20% -15% Frequency recovery time 3S voltage recovery time 1S(voltage ±3%) THF <3 TIF <50 Conform to the standard of NEMA MG1-22.43 www.grupotecnolife.com Page 1 of 5 PGS: 08/2012

Equipment Instruction Performance Parameters Model:Dongfeng Cummins engine 4B series Construction:Adopt forged steel camshaft and crankshaft, High strength cylinder block design, plenty parts cast on the Cylinders, stiffness strong, high pressure resistant capacity is high, longer service life. Starting system:24vdc starting motor Integrated design: Cylinders cylinder head together, decreased connection, reduced 40% parts than other same kind engine, failure rate bring down a lot. Fuel system: Rotator high pressure fuel pump, lower fuel consumption, and reduce noise effectively. Filter system: Dry core air filter with intake resistance indicator. Rotate Paperbased full flow and bypass oil filter. Rotate anti-corrosion water filter. Advanced design and superior manufacture: Adapt severe work condition, high strength, heavy loading work capacity. Performance Parameters Type: Stamford / Marathon/ Faraday/Engga Brushless, 4 pole rotating magnetic field, single bearing, with protective cover. H class insulation Standard IP23 grade Cooling system AC exciter, rotate rectifying unit Stator winding after dip treating, Surface override epoxy insulation varnish Rotor and exciter get treatment of high temperature insulating resin, will be more applicable for severe environment. Rotor dynamic balancing accord with standard BS5625,class 2.5. Advanced lubricating grease seal long time bearing. Supplied Accessories Silencer bellows exhaust bend Battery connect wire Files of original factory of engine and alternator Generator set manual book, certificate of conformity Optional Items Silent/trailer type genset Oil water separator Heat exchanger water tower cooling system Low water level, low fuel oil warning function Genset environmental protection Mains supply monitoring automatic control system Storage fuel tank BAC 06 battery charger www.grupotecnolife.com Page 2 of 5 PGS: 08/2012

Intelligent Control System Standard Detection Function 3 phases voltage Ua,Ub,Uc 3 phases current La,Lb,Lc Frequency F1 Active power PA Apparent power PR Power factor PF Coolant temperature WT / display Oil pressure OP kpa/psi/bar display Speed RPM Battery voltage V HC timer records 99999 hours The maximum cumulative times of starting can reach 999999 Standard Protection Function Genset Protection Programmable alarm and status input Emergency stop Protection Stop for over speed Alarm for low/high battery voltage Alarm/Stop for low oil pressure Alarm for shortage of battery Alarm/Stop for high coolant temperature Stop for failure to start/jigger Indication for sensor fault Protection Stop for over high/low voltage Stop for over frequency Alarm/stop for over current Stop for low frequency Stop for loss of voltage detection signal Control System Components Control switch manual/auto/stop/start Screen menu selection button Setting button Emergency stop button Fault status indicators Digital display Communication Interface (optional function) Adopt international standard MODBUS communication protocol with error detection as well as RS232/ RS485 (RS485 is opto-isolated type) Realize functions including remote control, telemetry and telesignalling, which are facilitate to monitor gensets. www.grupotecnolife.com Page 3 of 5 PGS: 08/2012

Data sheet of Genset Model PDC30S-60 PDC38S-60 PDC60S-60 PDC66S-60 PDC80S-60 Genset Prime Rating (kw) 27 35 55 60 72 Standby Rating (kw) 30 38 60 66 80 Prime current(a) 48.7 63 99 108 130 Frequency(hz) 60 60 60 60 60 Model 4B3.9-G2 4BT3.9-G2 4BTA3.9-G2 4BTA3.9-G2 4BTA3.9-G11 Gross 80 30 40 60 67 output-prime (kw) Gross / / 45 65 / output-standby (kw) Bore * stroke 102*120 102*120 102*120 102*120 102*120 Cylinders and build 4-Inline 4-Inline 4-Inline 4-Inline 4-Inline Cubic capacity(l) 3.9 3.9 3.9 3.9 3.9 Compression Ratio 17.5:1 17.5:1 17.3:1 17.3:1 17.3:1 Intake way Naturally aspirated Turbocharging Max intake resistance (kpa) 5.08 6.35 6.2 6.2 6.2 Air intake (m 3 /h) 118 177.6 354 354 375 Max exhaust back pressure (kpa) 10.2 10.2 10.2 10.2 10.2 Exhaust gas 243 426 888 888 450 flow(m 3 /h) Exhaust temp( ) 410 487 497 497 526 Cooling way Radiator and Radiator and fan fan Radiator and fan Radiator and fan Radiator and fan Fan exhaust flow 150 150 158 158 102 (m 3 /min) Coolant capacity (L) 17.2 21 24 24 24 Highest water temperature( ) 104 104 104 104 100 Minimum air opening 0.9/0.5 0.9/0.5 0.9/0.5 0.9/0.5 0.9/0.5 to room (m 2 ) Thermostat range ( ) 82-95 82-95 82-95 82-95 82-95 Max oil temperature ( ) 121 121 121 121 121 Lubrication system oil capacity (L) 11 11 11 11 11 Fuel consumption(l/h) 7.4 10.5 14.2 14.2 20 Standard Governor/Class electronical electronical electronical electronical electronical Prime voltage(v) 400/230 400/230 400/230 400/230 400/230 Prime power factor 0.8 0.8 0.8 0.8 0.8 www.grupotecnolife.com Page 4 of 5 PGS: 08/2012

Exciter Brushless, Brushless, Brushless, Brushless, Brushless, Self-exciter Self-exciter Self-exciter Self-exciter Self-exciter Max voltage regulation ±1% ±1% ±1% ±1% ±1% phase 3 phase 3 phase 3 phase 3 phase 3 phase Protection class IP21 IP21 IP21 IP21 IP21 Insulation class H H H H H Battery Rated capacity (AH) Dimension and Weight Model Fuel tank capacity (L) Gross weight (kg) Net Weight (kg) Dimension A Dimension B Dimension C PDC30S-60 110 744 672 1980 790 1320 PDC38S-60 110 786 714 2030 790 1320 PDC60S-60 110 880 808 2080 790 1340 PDC66S-60 110 880 808 2080 790 1340 PDC80S-60 110 920 843 2180 790 1340 www.grupotecnolife.com Page 5 of 5 PGS: 08/2012