Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Similar documents
Beverage Grade Carbon Dioxide

C2, C3, C4 Monomer Analysis

Antek Gas Chromatography Products: A Guided Tour Through Industry

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Experience the Difference

GC Method Compliance and Large Valve Oven Application

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Application. Gas Chromatography June 1995

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

S-PRO 3200 GC System for Sulfur Analysis

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

Irving Oil Whitegate Refinery Limited

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

Operation and Applications of Differential Flow Modulation

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

Live Crude Oil Volatility

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

performance productivity reliability

Using the PSD for Backflushing on the Agilent 8890 GC System

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

DANI Transformer Oil Gas Analyzer

Live Crude Oil Volatility

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Fundamentals of Petroleum Refining Refinery Products. Lecturers: assistant teachers Kirgina Maria Vladimirovna Belinskaya Natalia Sergeevna

Application Note. Abstract. Authors. Environmental Analysis

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN)

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

ETHYLENE-PROPYLENE PROCESS ECONOMICS PROGRAM. Report No. 29A. Supplement A. by SHIGEYOSHI TAKAOKA With contributions by KIICHIRO OHYA.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Zeolite Catalyst. Methanol. Propylene. Petrochemical Research & Technology پژوهش و فناوري پتروشیمی

Application Note. Authors. Abstract. Energy & Chemicals

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard

ANTEK APPLICATED Turn-Key GC solutions

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Technical Procedure for Gas Chromatography (GC-FID)

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Setting up SilFlow for BackFlush in your GC

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

DETERMINATION OF N-BUTANOL AND ISOBUTANOL IN GASOLINE USING GAS CHROMATOGRAPHY (GC-FID)

6. Lone Star NGL Mont Belvieu LP E/P Mix November 16, Lone Star NGL Mont Belvieu LP Refinery Grade Butane November 29, 2012

Rosemount 570 Natural Gas Chromatograph

Catalysts for olefin processes. A range of performance catalysts and absorbents for use across the olefins value chain.

Crude Assay Report. Crude Oil sample marked. Barrow Crude Oil. On Behalf Of. Chevron Australia Pty Ltd. Laboratory Supervisor. Crude Assay Chemist

Hydrocracking of atmospheric distillable residue of Mongolian oil

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Siemens AG, 2008 MAXUM II

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Gary Stidsen Jaap de Zeeuw

Analysis of Petroleum Fractions by ASTM D2887

Lecture 3: Petroleum Refining Overview

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Application of High-Temperature Simulated Distillation to the Residuum Oil Supercritical Extraction Process in Petroleum Refining

Thermal Conversion of Fossil and Renewable Feedstocks

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN)

I SO9001 I SO14001 CE

Agilent and ASTM. Update on Recent Activities. Page 1

ASTM D 6730 Detailed Hydrocarbon Analysis

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

CERTIFICATE OF ACCREDITATION

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

CERTIFICATE OF ACCREDITATION

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

RESOLUTION MEPC.272(69) (Adopted on 22 April 2016) AMENDMENTS TO THE NOX TECHNICAL CODE 2008 NITROGEN OXIDES FROM MARINE DIESEL ENGINES

HD and HDL Single-Stage Non-Lube Gas Compressors

Collection & Analysis of Reduced Sulfur Compounds in Air

Sensitivity analysis and determination of optimum temperature of furnace for commercial visbreaking unit

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

breakthrough versatility

Phillips 66 Pipeline LLC. Blue Pipeline Natural Gas Liquids Specifications

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

MET-Biodiesel Capillary GC Columns

On-Line Process Analyzers: Potential Uses and Applications

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

GC Instruments GC Columns GC Accessories

Extended fuel flexibility capabilities of the SGT-700 DLE combustion system

ABOUT GAS INNOVATIONS

Agilent Multimode Inlet for Gas Chromatography

Transcription:

Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION

Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over 23 years Wasson-ECE refinery gas analyzers are an integral part of any refinery or petrochemical lab. These analyzers provide valuable information regarding plant operations, unit optimization, and quality control and often carry the heaviest sample loads because of the critical information they provide. Comparison Chart Precision 383D 783D 383D-SCD 583D Generating repeatable data through innovative engineering Run Time (minutes) Detectors 15 Method 1: 15 Method 2: 15 Method 1: 15 Method 2: 25 TCD/TCD/FID TCD/TCD/FID TCD/TCD/FID SCD 6 TCD/TCD/FID Efficiency Providing high speed multi-dimensional chromatography Number of Valves Liquid Sample Valves Electronic Pressure Control Fused Silica Lined Tubing On-Line Availability 5 6 6 5 Optional Optional Optional Optional Yes Yes Yes Yes Optional Optional Yes Optional Yes Yes Yes Yes 383D Components 383DH 383D-SCD 583D The refinery gas family of applications is designed to provide a flexible approach to meet your analytical requirements. As a premier channel partner of Agilent Technologies, Wasson-ECE extends the capabilities of the 7890A GC to meet three key requirements of refinery gas analysis: reliability, efficiency, and precision. Method 1 H 2 CO CO 2 Ar/O 2 N 2 H 2 S C 1 -C 7 C 1 -C 5 Method 2 C 3 -C 12 BTEX Trace Sulfurs WASSON - ECE INSTRUMENTATION Refinery Gas

Introduction Multi-dimensional Valves: Valves allow for a custom analysis of complex sample streams. Application Highlights Flame Ionization Detector Flame Ionization Detector (FID) is used to A flame ionization detector (FID) is detect used the to C 1 detect through the C 7 paraffins C and olefins to a lower detection limit of 20 1 through C ppm, except for 7 paraffins and olefins to a lower trace detection peaks eluting limit of on 20 the ppm. tail of a major component. Capillary Columns: Capillary columns have a higher number of theoretical plates than packed columns and when coupled with multi-dimensional valves offer a powerful solution to the most complex analyses. Thermal Conductivity Detectors A thermal conductivity detector (TCD) is used to detect hydrogen in a nitrogen carrier to a lower detection limit (LDL) of 100 ppm. A second TCD is used to detect the other permanent gases in a He carrier to an LDL of 200 ppm. Agilent 7890A Interface: Our solutions are built around the newest Agilent GC. This allows for easy integration into your lab or process. Electronic Pressure Control Electronic pressure control (EPC) allows for an analysis of C 1 through C 7 olefins and benzene with a run time of less than 15 minutes. EPC pressure programming provides a fast analysis for higher sample throughput. Ph. 970.221.9179 www.wasson-ece.com

Application 383D The 383D FID Channel 4. Analysis Time = 15 minutes The FID detects C 1 through C 7 paraffins and olefins to a lower detection limit of 20 ppm. 1. 2. 6. 8. 10. 1. Methane 2. Ethane 3. Ethylene 4. Propane 5. Cyclopropane 6. Propylene 7. Acetylene 8. Isobutane 9. Propadiene 10. n-butane 11. t-2-butene 12. 1-Butene 20. 13. Isobutene 14. c-2-butene 15. Neopentane 16. Isopentane 17. Methyl Acetylene 18. n-pentane 19. 1,3-Butadiene 20. 3-Methyl-1-Butene 21. t-2-pentene 22. 2-Methyl-2-Butene 23. 1-Pentene 24. 2-Methyl-1-Butene 25. c-2-pentene 26. Neohexane 27. Hexane 28. Benzene Optional Configurations 3. 5. 7. 9. 11. 12.13. 16. 14. 18. 17. 15. 19. 22.23. 25. 24. 21. 26. 27. 28. Liquefied Petroleum Gas (LPG) - Allows liquid sample valves to be pressurized for liquid samples. 4 6 8 10 12 Trace CO and CO 2 by methanizer High temperature injection for heavy fractions Analysis of percent level water The 383D refinery gas analyzer allows for a detailed analysis of feed stocks through the use of multiple detectors. This solution can be extended to include the analysis of sulfur components and heavier hydrocarbons. Configuration utilizing dual thermal conductivity and a mass selective detector for maximum flexibility. The 383D TCD Channel Dual TCDs detect hydrogen, carbon dioxide, ethane, ethylene, acetylene, hydrogen sulfide, oxygen/argon composite, nitrogen, and methane. The TCD signals are summed to provide a single chromatogram. 1. 2. 3. 4. 5. 1. Valve Switch 2. Hydrogen 3. Carbon Dioxide 4. Ethylene 5. Ethane 6. Acetylene 7. Hydrogen Sulfide 8. Argon/Oxygen 9. Nitrogen 10. Methane 11. Carbon Monoxide 6. 7. 8. 9. 10. 11. 2 4 6 8 10 12 WASSON - ECE INSTRUMENTATION Refinery Gas

Application 583D Analysis Time = 6 minutes The 583D FID Channel 1. 1. C 6 + Backflush 2. Methane 3. Ethane 4. Ethylene 5. Propane 6. Cyclopropane 7. Propylene 8. Acetylene 9. Isobutane 10. Propadiene 11. n-butane 12. t-2-butene 13. 1-Butene 14. Iso-Butylene 15. Cis-2-Butene 16. Isopentane 17. n-pentane 18. 1,3-Butadiene 2. 3. 4. 5. 6. 7. 9. 11. 8. 10. 12. 13.14. 15. 18. 16. 17. The FID analyzes C 1 through C 5 paraffins and olefins and initial C 6 + backflush. 1 2 3 4 5 The 583D refinery gas analyzer allows for a rapid analysis of feed stocks. This configuration allows the flexibility of a longer analysis if higher resolution is required. 2. 1. Valve Switch 2. Hydrogen 3. Carbon Dioxide 4. Hydrogen (not quantified) 5. Argon/Oxygen 6. Nitrogen 7. Methane 8. Carbon Monoxide 5. 6. The 583D TCD Channels Dual TCDs detect hydrogen, carbon dioxide, argon/oxygen composite, nitrogen, methane, and carbon monoxide. 1. 3. 7. The TCD signals are summed to provide a single chromatogram. 4. 8. 1 2 3 4 5 Ph. 970.221.9179 www.wasson-ece.com

Optional Configurations 783D The 783D extends the capability of the 383D or 583D applications by adding an extra capillary column in series with the FID. This feature allows the system to perform an additional method for analysis of heavier hydrocarbon fractions and BTEX. Benefits of Options on 383D or 583D 783D Extends the capability of the 383D or 583D More economical than buying an additional instrument The ultimate in refinery gas flexibility SCD Option Sulfur detection down to 10 ppb Can be configured in compliance with ASTM D5504 or ASTM D5623 Inert fused silica coating used on all sample wetted components Independent subsystem allows simultaneous sulfur analysis SCD Option The SCD option adds the ability to measure trace sulfurs. Using an Agilent Sulfur Chemiluminescence Detector (SCD), the system can be modified to perform simultaneous refinery gas and trace sulfur analysis. WASSON - ECE INSTRUMENTATION Refinery Gas

Wasson-ECE Instrumentation Engineered Solutions, Guaranteed Results. Wason-ECE Instrumentation specializes in configuring and modifying new or existing gas chromatographs exclusively from Agilent Technologies to become guaranteed, turn-key analytical systems. Our customers describe their objectives and their samples: analytes, concentration ranges, phases, temperature, throughput, and any special needs. From this dialog we configure a task specific instrument. We add extra ovens, valves, plumbing, flow control, columns, electronics, and software to yield a complete solution. This saves our clients valuable time and delivers instruments that are state-of-the-art and ready for use upon installation. The complete analytical method is developed, tested, and documented utilizing our experience working with numerous companies with similar needs and goals. The resulting chromatograms and reports are inspected by our application chemists and you, to ensure system performance and design quality. Our field engineers then install each system and provide training. After installation, and throughout the life of the chromatograph, our support chemists are ready to help. We can assist with application details, questions, training, calibration, maintenance, and on-site service. Wasson-ECE brings experience and efficiency to your project, giving you confidence in the quality of your results. Ph. 970.221.9179 www.wasson-ece.com

Please contact us for more information Engineered Solutions, Guaranteed Results. Ph. 970.221.9179 Fx. 970.221.9364 www.wasson-ece.com sales@wasson-ece.com