Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Similar documents
Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Reference Number PDS 18 - (RIC Standard: EP SP)

Title Specification - Fuses for Railway Signalling Applications. Reference Number SPS 32 - (RIC Standard: SC SP)

Status Date Prepared Reviewed Endorsed Approved

Title Requirements for Electric Aerials Crossing ARTC Infrastructure. Reference Number PYS 02 - (RIC Standard: EP SP)

Low Voltage Power Supplies in Electrified Areas

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Specification for 1500V DC Traction Supply WOS 01.E

GT/TDINT100 Issue: 1 Date: SEP 1993 Page 1 of 11

Procedure PR D Electrical Permits. Engineering Procedure Electrical Distribution Unit. Version 1.0. Date in Force: 4 November 2015

Title 11 kv AC Indoor Switchgear Non-Withdrawable. Reference Number PPS 04 - (RIC Standard: EP SP)

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Procedure PR D Definitions and Conventions for Electrical Safety. Engineering Procedure Electrical Distribution Unit. Version 1.

Guidance for Low Voltage Electrical Installations

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

Underground Distribution Construction Manual

Substation Lightning Protection. Document Number: 1-11-FR-11

MESP TECHNICAL SPECIFICATION FOR A STATIONARY CONTROL BATTERY AND CHARGER SET FOR USE IN A SUBSTATION

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

Minimum Operating Standards for. Rolling Stock WOS 01

The impact of the 18 th Edition (BS 7671:2018) Sections 722, 753 and [new] 730

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

This page is purposely left blank

PREVENTION OF STRAY CURRENT BY THE MAINTENANCE-OF-WAY

Research Brief. Impact of higher 25kV fault currents. T873 - October Background. Aims

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

SNZ TR 6120:2014. New Zealand Technical Report. Low voltage supply earthing systems SNZ TR 6120:2014

Structural Requirements For Drawgear And Buffers On Railway Vehicles

Engineering Instruction

Australian/New Zealand Standard

Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

EARTHING YOUR QUESTIONS ANSWERED

Engineering Recommendation P26

TRANSMISSION SYSTEMS

Maintenance of Signal Sighting and Signals

CHAPTER V RESIDENTIAL WIRING

Network Safeworking Rules and Procedures

Scale of Inspection Fees of Electrical Inspectorate Schedule. I. Fees for Initial Inspections:

MCST LIGHTING AND POWER DESIGN AND CONSTRUCTION

Service & Installation Rules

Equipotential Bonding of Rail Vehicles to Running Rail Potential

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Electrical Testing Company Pty Ltd / download at electricaltestingcompany.com.au / AS/NZS 3003:2011 Cardiac (Rev C)

Guidelines for connection of generators:

Small craft Electric propulsion system

Small craft Electrical systems Alternating current installations

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

Signalling Power Systems

Voltage limiting device HVL

Substation LV AC Supplies. Document Number: 1-11-FR-04

Discipline: Engineering (Track & Civil) Category: Code of Practice. Clearances. Section 7. Applicability. ARTC Network wide.

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

MAINTENANCE AND TESTING OF ENTITY WORKS, ELECTRICAL INSTALLATIONS AND ELECTRICAL EQUIPMENT CS-OHS-32

Locating Ground Mounted Equipment

Energized Electrical Work

Voltage limiting device HVL

Track Circuit Assister Configuration for Rail Vehicles

AS/NZS :2016. Grid connection of energy systems via inverters AS/NZS :2016. Part 1: Installation requirements

FREMANTLE PORTS 2015 ELECTRICAL PLANNING FACT SHEET PLANNING BRANCH

Construction and Connection of Street Light Assets

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

Electrical Awareness and Considerations

Requirements for Secondary Voltage Revenue Metering (750 V and less)

The Knowledge Bank at The Ohio State University. Ohio State Engineer. Electrolysis in Underground Structures

Estimation of electrical losses in Network Rail Electrification Systems

2 x 25 kv ac / 1 x 25 kv ac Grounding and Bonding

User's Manual. Earth Ground Resistance Tester. Model Introduction

Electricity Safety (Electrical Installations) Regulation 2005

Earthing Principles. Symmetra PX 250/500 kw

AS/NZS 3112:2004 AS/NZS

045 : 2000 CEB STANDARD

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

Electrical Testing Company Pty Ltd / / AS/NZS 3003:2011 Body (Rev E)

Functions provided by measuring relays in railway equipment

Network Safeworking Rules and Procedures

Technical Standard - TS 129. Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW. SA Power Networks. Published: November 2017

Electrification Asset Usage Charge. Presentation to TESG. Matt Skinner, Development Manager 11 th March 2013

The Licensed Distribution Network Operators of Great Britain

Solar PV General Introduction Guide for Electricians

UK Power Networks Use of System Charging Methodology

Electricity Safety (Installations) Regulations 2009

Australian/New Zealand Standard

FAQ s. Designing metering switchboards as per Victorian service installation rules

NETWORK ELECTRICAL TECHNOLOGY LLC

FINAL-ER 42 Electrician Regulations Answer Schedule

NZQA registered unit standard version 1 Page 1 of 5. Apply and remove portable earths in an electricity supply system

POSITION PAPER Version 3.0

Management of Clearances

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

THUNDERBIRD Solar Electric Fence Energisers. S20 / S20B / S40 / S40B / S79 / S150

Operating Procedures Overhead and Electrical Equipment - Procedures 1 to 11

NP 007 Service Rules

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

FACT SHEET Standard: Electrical Safety

Transcription:

Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards and Systems Refer to Reference Number Signalling Standards Engineer T Moore GM Infrastructure Strategy & Performance M Owens Safety Committee Refer to minutes of meeting 24/01/05

Disclaimer Australian Rail Track Corporation has used its best endeavors to ensure that the content, layout and text of this document is accurate, complete and suitable for its stated purpose. It makes no warranties, express or implied, that compliance with the contents of this document shall be sufficient to ensure safe systems of work or operation. Australian Rail Track Corporation will not be liable to pay compensation in respect of the content or subsequent use of this document for any other purpose than its stated purpose or for any purpose other than that for which it was prepared except where it can be shown to have acted in bad faith or there has been willful default. Document Approval The technical content of this document has been approved by the relevant ARTC engineering authority and has also been endorsed by the ARTC Safety Committee. Document Supply and Control The Primary Version of this document is the electronic version that is available and accessible on the Australian Rail Track Corporation Internet and Intranet website. It is the document user s sole responsibility to ensure that copies are checked for curency against the Primary Version prior to its use. Copyright The information in this document is Copyright protected. Apart from the reproduction without alteration of this document for personal use, non-profit purposes or for any fair dealing as permitted under the Copyright Act 1968, no part of this document may be reproduced, altered, stored or transmitted by any person without the prior written consent of ARTC. March 2005 Page 2 of 12

About This Standard This document lists the publications and drawings that are referenced in the documents contained in Volume 2 of this manual, or that can provide extra background information. The drawings are held in the RSA Plan Room in Transport House. This document also provides a list of definitions of words that have a precise meaning in relation to the documents contained in Volume 2 of this manual. March 2005 Page 3 of 12

Document History Primary Source RIC Standard EP 12 00 00 02 SP Version 2.0 List of Amendments ISSUE DATE CLAUSE DESCRIPTION 1.1 11/03/2005 Disclaimer Minor editorial change March 2005 Page 4 of 12

Contents 1. References...7 1.1. General Publications...7 1.2. Drawings...7 2. Definitions used in this Volume...7 2.1. 1500 V structure...7 2.2. Appreciable dc leakage current...8 2.3. Bonding conductor...8 2.4. Conductor...8 2.5. Consumer s mains...8 2.6. Consumers terminals...8 2.7. Distribution Substation...8 2.8. Earth grid (also known as Earth mat)...8 2.9. Earth potential rise...8 2.10. Earthing conductor...8 2.11. Earthing system...8 2.12. Electrified area...8 2.13. Electrode (also known as earth rod)...9 2.14. Electrolysis...9 2.15. High voltage...9 2.16. Installation main switchboard...9 2.17. Insulated...9 2.18. Local Electricity Distributor...9 2.19. Low voltage...9 2.20. Metalwork...9 2.21. Near 1500 V track...9 2.22. Point of attachment...10 2.23. Prospective touch voltage...10 2.24. ARTC consumer s terminals...10 March 2005 Page 5 of 12

2.25. ARTC service mains...10 2.26. ARTC supply...10 2.27. Rail...10 2.28. Railway corridor...10 2.29. Remote earth...10 2.30. Sectioning Hut...10 2.31. Service equipment...10 2.32. Service line...11 2.33. Spark gap...11 2.34. Step voltage...11 2.35. Substation...11 2.36. Supply main switchboard...11 2.37. Switchboard...11 2.38. System Substation...11 2.39. Touch voltage...11 2.40. Traction Substation...11 2.41. Transfer voltage...12 2.42. Transformer mains...12 2.43. Voltage...12 March 2005 Page 6 of 12

1 References 1.1 General Publications AS-3000 - SAA Wiring Rules AS-3108 - Approval and test specification-particular requirements for isolating transformers and safety isolating transformers - 1990 EC 5 - Guide to protective earthing - Electricity Council of N.S.W. - 1992 UIC - 605-1 - International union of railways codes Cathodic protection of underground structures by W. K. Woodberry 1.2 Drawings D 89147 A1 88496 B 87137 K 87124 C 87115 B 82693 C 79930 D 77535 Electrolysis isolating joint for underground water pipe. Station low voltage electrical services general information Strathfield - MacDonaldtown S & C Relay Building Electrical Branch Power Room, Equipment Layout and Schematic Diagram Standard Platform Lighting Arrangement Earthing Systems. Arrangement of LV Installations in Contact with 1500V Structures. Train maintenance centres proposed low voltage earthing arrangements. HV outdoor equipment typical earthing arrangements. AC welding machines installation of earth leakage circuit breaker typical wiring diagrams. C 74378 Modified earthing systems 415/240 V. 2 Definitions used in this Volume 2.1 1500 V structure A 1500 V structure is a structure which has 1500 V equipment attached to it with insulators. This includes structures specifically designed for supporting overhead wiring and structures built for other purposes but also supporting overhead wiring, such as overbridges. 2.2 Appreciable dc leakage current If 200 ma of dc current can be measured for a period of 2 hours during a test conducted over 24 hours, this structure or building is to be regarded as likely to pick up appreciable amounts of stray current. March 2005 Page 7 of 12

2.3 Bonding conductor A bonding conductor is a conductor connecting two or more metal structures with 1500 V overhead wiring attached for the purpose of carrying traction fault currents during electrical disturbances. The bonding conductor shall have a minimum size of 70 mm ² copper and shall be insulated to 0.6/1.0 kv. 2.4 Conductor A conductor is a wire, cable or other form of material suitable for carrying current. 2.5 Consumer s mains The consumer s mains the conductors between the point of attachment and the service equipment. They are determined in accordance with the local Electricity Distributor s Service and Instalation Rules and from AS 3000. 2.6 Consumers terminals The consumers terminal is the point at which the Distributors system is connected to the consumer's installation. 2.7 Distribution Substation The distribution substation means all non-system substations containing high voltage electrical equipment (ie high voltage locations without circuit breakers). 2.8 Earth grid (also known as Earth mat) The earth grid or earth mat is a group of conducting elements, both vertical and horizontal, in electrical contact with the earth designed to disperse electrical fault currents into the earth and to control touch and step voltages. 2.9 Earth potential rise The earth potential rise is the maximum potential rise of an earthing system, with respect to remote earth. 2.10 Earthing conductor The earthing conductor is a conductor used to connect any metal work required to be earthed to the neutral point of the transformer or such other earthing point as may be determined. 2.11 Earthing system The earthing system includes the earth grid and all conductors, piping, electrodes, clamps and other metalwork connected to the grid. 2.12 Electrified area The electrified area is the section of railway provided with 1500 Vdc overhead wiring, nominally bounded by Bowenfels, Glenlee, Kiama and Newcastle. March 2005 Page 8 of 12

2.13 Electrode (also known as earth rod) The electrode or earth rod is a vertical conducting element specifically designed or adapted for discharging the earth fault current into the ground as required by the earthing system design. 2.14 Electrolysis Electrolysis refers to the process where corrosion occurs to a buried metal structure when dc current leaves the structure to enter the electrolyte of the surrounding soil. 2.15 High voltage This is a voltage exceeding 1000 Vac or 1 500 Vdc. 2.16 Installation main switchboard This is a low voltage switchboard from which the supply to the whole installation can be controlled. An installation is as defined in AS 3000, SAA Wiring Rules. This switchboard contains the consumer terminals and should not be confused with the supply main switchboard, refer to definition 2.36. 2.17 Insulated Insulated means separated from adjoining conducting material by a nonconducting substance which permanently provides resistance to the passage of current, or to disruptive discharges through or over the surface of the substance at the operating voltage, to obviate danger of shock or injurious leakage of current. 2.18 Local Electricity Distributor The local electricity distributor is any organisation engaged in the supply of electricity, excluding the Australian Rail Track Corporation. 2.19 Low voltage Low voltage is a voltage exceeding 50 Vac or 120 Vdc but not exceeding 1000 Vac or 1 500 Vdc. 2.20 Metalwork Metalwork includes any reinforced or prestressed concrete parts of an installation but shall exclude minor attachments to wood poles and wood pole identification discs. 2.21 Near 1500 V track Near 1500 V track is that area inside the railway boundary and within 20 m of the centre-line of any track with overhead wiring which is electrified at nominal 1500 Vdc, or 20 m of any 1500 Vdc negative equipment or conductors, or 20 m of any metal which is spark-gapped to the rail measured horizontally at right angles. March 2005 Page 9 of 12

2.22 Point of attachment The point of attachment is the point at which a local Electricity Distributors service mains are terminated on a ARTC building, pole or structure. 2.23 Prospective touch voltage The prospective touch voltage is the voltage difference which may appear between any uninsulated metalwork located within 2.4 metres of the ground and any point on the surface of the ground separated by a horizontal distance of one metre, which is considered to be equal to a person s normal reach. 2.24 ARTC consumer s terminals ARTC consumer s terminals are the point at which the ARTC Distribution system is connected to the consumer s instalations. 2.25 ARTC service mains The ARTC service mains are the conductors between the supply main switchboard, or change-over panel if there is a back-up supply, and the ARTC consumers terminals on the installation main switchboard. 2.26 ARTC supply 2.27 Rail The ARTC supply is an electricity supply taken from a Australian Rail Track Corporation owned high voltage or low voltage network. Rail is the traction rail, that is the rail intended for conduction of the traction return current. 2.28 Railway corridor The railway corridor is any land owned by one of the three railway entities nominated under the Transport Administration Amendment (Rail Management) Act 2000, ie, Australian Rail Track Corporation, State Rail Authority of NSW or Freight Corp. 2.29 Remote earth Remote earth is a true earth potential of zero volts. 2.30 Sectioning Hut A sectioning hut is a System Substation, with dc circuit breakers but without rectifiers, that sectionalises the 1500 Vdc overhead wiring for dc protection and voltage regulation. 2.31 Service equipment Service equipment is the metering and control equipment supplied and installed as specified in either ARTC's or the local Electricity Distributor's service and installation rules. March 2005 Page 10 of 12

2.32 Service line Service lines are the conductors supplied by a local Electricity Distributor to the point of attachment. 2.33 Spark gap The spark gap is a device used to connect specific types of 1500 V structures (refer to Specification EP12200001 SP - Bonding of Overhead Wiring Structures to Rail contained in Volume 1) to rail when the potential difference between the two rises above 750 V. 2.34 Step voltage The step voltage is the voltage which may appear between any two points on the surface of the ground separated by a horizontal distance of one metre, which is considered to be equal to a person s normal step. 2.35 Substation This a substation, traction substation, transformer room, switchroom, sectioning hut, pole or pad mounted transformer location, containing high voltage electrical equipment. 2.36 Supply main switchboard The supply main switchboard is the first low voltage switchboard between the transformer terminals and the low voltage installation. The supply main switchboard is owned by ARTC and is the location to establish the one and only connection between earth and neutral. 2.37 Switchboard A switchboard is any distribution board or switchboard other than the supply main switchboard or installation main switchboard. 2.38 System Substation A system substation a traction substation, sectioning hut or a substation location that has a voltage greater than 2 kv and includes a high voltage circuit breaker as an item of equipment. The voltage of greater than 2 kv has been selected to exclude the ARTC 2 kv (nominal) distribution system. 2.39 Touch voltage Touch voltage is the voltage across the body, under fault conditions, in a position described as for the prospective touch voltage but allowing for the voltage drop caused by a current flowing in the body. 2.40 Traction Substation A traction substation is a System Substation that supplies 1500 Vdc power for the overhead wiring using high speed dc circuit breakers. March 2005 Page 11 of 12

2.41 Transfer voltage Transfer voltage is the voltage difference between an earthing system and an exposed metal object connected to a remote earth. 2.42 Transformer mains Transformer mains for a supply from the ARTC high voltage network are the conductors between the transformer secondary terminal and the supply main switchboard, or change-over panel where there is a back-up supply. For a supply from a local Electricity Distributor network the transformer mains are the conductors on either side of the isolating transformer, that is, between the service equipment and the supply main switchboard, or change-over panel where the supply is installed as a back-up supply. 2.43 Voltage Voltage means nominal potential difference between conductors or the nominal potential difference between a conductor and earth, whichever is applicable. March 2005 Page 12 of 12