Supply Return. Pumping station 2-way "Solar 2" _!':'! _. Directions for the use of the flowmeter to fill the installation:

Similar documents
Pumps Certified for North American Market

Installation instruction

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Series description: Wilo-Stratos ECO-STG

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Liquid ring compressors

Contents. Identification

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors

Data sheet: Wilo-Stratos PICO 25/1-6

Data sheet: Wilo-Yonos PICO 25/

Data sheet: Wilo-Stratos PICO 25/

SCX-DCX SXM-DXM. SINGLE AND TWIN-HEAD CIRCULATORS Heating and air conditioning Light commercial range 2 Pole - 50 Hz 230 V OPERATING LIMITS

Data sheet: Wilo-CronoLine-IL 65/160-5,5/2

Data sheet: Wilo-CronoLine-IL 65/130-4/2

Data sheet: Wilo-CronoLine-IL 50/120-2,2/2

Data sheet: Wilo-CronoLine-IL 80/145-1,1/4

Data sheet: Wilo-CronoLine-IL 50/200-1,5/4

Data sheet: Wilo-Yonos MAXO 40/0,5-16

FAC, FAD, FAT, FAG, FAH, FACV, FADV, FATV SIGMA PUMPY HRANICE THREE-SCREW PUMPS

Inline Pumps. Product review. Wilo-VeroLine-IPL. Single-head pumps: Single stage inline, flanged, long coupled, mechanical sealed dry rotor pump

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

3 Specification Magneta Smedegaard

Series description: Wilo-TOP-STGD

Data sheet: Wilo-CronoLine-IL 40/220-1,5/4

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

real quality made in italy circulation pumps

RUJA AUTOMATION June User manual. D R PP Filter - Unit. Page 1 of 10 User manual D-R--P-Filter -Unit

CIRCULATION PUMPS FOR HEATING SYSTEMS AND AIR-CONDITIONING SYSTEMS VORTEX HEATING PUMPS

Grundfos Home Booster

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Liquid ring vacuum pumps

Data sheet: Wilo-CronoLine-IL 125/210-5,5/4

FCX TECHNICAL BOOKLET

40 geothermal ground loop manifolds

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC VALVES

Pressure boosting Single pumps

2-port ball valves with flanged connection, PN25

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data

CEB 71204/a of 13 december 2005 SLSHR. 3-Phase Totally Enclosed Induction Motor Steel Housing Water-Cooled 30 to 1800 kw

ACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB

2-port seat valves PN25 with flanged connection

4 Specification Magneta Smedegaard twin pumps

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Data sheet: Wilo-CronoLine-IL 100/250-5,5/4

Accessories. UP timer. Timer control. Approvals. UP Series

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

High-pressure pumps Series HP49

Electronic Control Valves

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF GB

HERZ PUMPFIX HERZ PUMPFIX. Datasheet 1 45XX XX, Issue Table of contents. Page 1. General information about HERZ PUMPFIX pump groups...

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

Circulators for heating and air-conditioning

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

High pressure centrifugal pumps

RMG Meßtechnik GmbH. Publication No E

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

M Series Condensate Recovery Unit

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

4-Way Mixing Panel Submittal - Page 1 of 6

T200 Pressure Regulator

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Data sheet: Wilo-TOP-Z 30/10 (1~230 V, PN 10, RG)

SIL Inline Single Stage Centrifugal Pumps

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

Series: CT. 4CT RPM - 60Hz. CT RPM - 60Hz. (See Indivdual curves for symbol number)

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

Powers TM Controls SW 141 Differential Static Airflow Switches

Hydraulic gear pumps and motors

Off-line filter / cooler unit BKF

Data sheet: Wilo-Stratos-Z 25/1-8

2-Port Seat Valves with Flange, PN 25

SCX-DCX - SXM-DXM. SINGLE AND TWIN-HEAD CIRCULATORS Heating and air-conditioning Light commercial range 50 Hz OPERATING LIMITS APPLICATIONS ADVANTAGES

2-Port Seat Valves with Flange, PN 25

Richter Sampling Valves

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Submit Manufacturer certification and test reports. Submit Detail drawing brochure catalogue. Submit Manufacturer certification and test reports

Richter Sampling Valves

LPE4. OptiLine. Product Description. Max differential pressure: 16 bar LPE GB

Centrifugal pumps. Main catalogue.

DESCRIPTION 9.4 G 3/4"M

Data sheet: Wilo-VeroLine-IPL 100/ /4

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

Data sheet: Wilo-VeroLine-IPL 65/ /2

Liquid ring vacuum pumps with magnetic coupling

2-Way & 3-Way Non Spring Return Characterized Ball Valves

Richter Sampling Valves

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Transcription:

Pumping station 2-way "Solar 2" F+ F+ (C) Security unit The security unit, CE and TUV approved, protects the installatjon from the overpressures. lt is calibrated at 6 bar, over this pressure the security unit starts, lt is also Drovided with a manometer and with a connection to the expansion vessel by a 3/4" flexible kit (optional), see here at the rioht. @@ Supply Return (A) Ballvalve on the supply way (thermoter with red ring and scale 0-120"C) with "Sola/' checkball. (B) Ball valve on the return way (thermoter with blue ring and scale 0-120"C) with "Solar" checkball. Solar Checkhall It is included into the ball valve both in the supply way and in the return way. lt ensures the seal and low head losses. To exclude the checkball valve, for instance case ol emptying rotate the handle by 45' clockwise. (D) Flowmeter The flowmeter allows to regulate the flow rate to the capacity of the installation, by a 3-way ball valve. lf the valve is closed the usual circulation is cut off, it is possible to use the side filling tap to flll the installation. There is also another side tap, for the draining. The proximity of the two taps helps these operations minimizing the distance between the filling and the draining. The flow rate is measured and shown by the special sliding cursor: the measurement is immediate thanks to the proximity to the regulation valve. As shown hereinunder three flowmeters are available with different intervals of measurement: 2-12Llmin,8-28 Umin and 8-38 Umin. (E) Circulating pump Three speed circulating pump with manual regulation, Thanks to the seal of the ball valves before and after the circulating pump, it can be removed without emptying the installation. Directions for the use of the flowmeter to fill the installation: Blockin! th. f lling/dr.ln Unscr whe fixing $rew, il again tum ng il ol 180' Flow nte shown (in this case _!':'! _.-,''':L-- (1) - Filling the installation: Remove the plugs from the side valves and connect the hose unions. Close the ball valve and open the side filling valve and draining valve. (2J- Starting the installation working: Open the ball valve and close the side filling and draining valves. Remove the hose unions and screw again the plugs. To avoid any casual opening of the side valves, il is beffer fo sfop the levers in the close posifron, as shown here aside. (3)- Regulate the flow rate using the regulation rod until the right flow rate is shown. lv.b. The flow rate is shown taking as reference the lower edge of the sliding cursor. (see picture)

General information Standard quick connection module V1 Connection type PL Capacitor Capacitor Yellow / Green Blue Brown Connection type PR Capacitor Capacitor Brown Yellow / Green Blue 6

General information Approved pump mounting arrangements : Viscous fluids / Hydraulic datas All hydraulic datas contained in this catalogue are based on handling water having a kinematic viscosity = 1 mm 2 / s Water / glycol mixtures, max. mixing ratio 1:3. These data are measured after a minimum of 12 hours of running-in. Minimum inlet pressure to prevent cavitation To avoid cavitation (vapour forming within the pump) it is necessary to maintain at the pump suction port an adequately high positive pressure (static head) in relation to the vapour pressure of the fluid being handled. Minimum inlet pressure in psi (m) at the pump suction inlet to avoid cavitation noise at 104 F (+40 C) ambient and max. water temperatures 122 F (50 C) 0.7 psi (0.5 m) 203 F (95 C) 4.4 psi (3.0 m) 230 F (110 C) 14.5 psi (10.0 m) For higher altitudes: add 0.14 psi (0.1 m) head / 328 ft (100 m) height increase. These minimum heads must be respectively increased when handling fluids of higher temperatures or lower densities, higher resistances at the pump suction side and in regions of lower atmospheric pressures. Circulating pump threaded connection Designation A T WILO Pump's section designation 15 25 30 Pump's thread diameter (inch) 1" 1½" 2" Pump's thread diameter (mm) 33,25 47,8 59,61 Pipe's diameter (inch) ½" 3/ 4 or 1" 1¼" Pipe's designation (mm) 15/21 20/27 or 26/34 33/42 7

General information General reference Permissible ambient air temperatures From 32 F to 140 F - with a fluid temperature not exceeding 203 F (From 0 C to +60 C - with a fluid temperature not exceeding 95 C) Condensation Pumps listed as being suitable of handling chilled water down to 14 F ( 10 C) are fully condensation-proof. Working Pressure Maximum working pressures to which pumps can be internally subjected to are: > pump housing cast iron: PN 10 > pump housing composite : PN 3 or PN 6 (please contact us) Max. fluid temperature > Cast iron pump housing: 230 F (110 C) > Composite pump housing: 203 F (95 C) Terminal box connections > The connecting cable can be led by the client through the packing cable gland on either right or left Electrical Wiring > All Wilo Intec UL pumps are suitable for wiring to the appropriate North American standard voltage 115 V (±10%) Frequency > All Wilo Intec UL pumps operate at 60 Hz as required in North America Replacement Pumps Customers are requested to provide after sales service when replacement pumps are required by their customers in North America. By prior agreement, Wilo North America can provide spares from its stock in Chicago and Calgary for pumps with standard configurations. These are defined as pumps with the following: 3 speeds 5 inch (130 mm) height Terminal box position 9 or 12 o clock for 1 inch connection Terminal box position 9 o clock for STAR U 25 (1.5 inch) and NFSL Packing gland left with cap (plug) on right hand side 16 ft (5 m) U, RSL, NFSL, HU pump housings. 8

Heating pump STAR U Type : STAR U STAR S 16 U 15 STAR S 16 U 25 STAR U Pump head (height of water at 0 flow): 16, 21 ft Pump Body: Cast Iron Connections Width: 1, 1 1 / 2, 2 Pump Height: 5 inch (130 mm), 7 inch (180 mm) 1 speed or 3 speed 9

Heating pump STAR U Star S 16 U Head (ft) 25 20 15 10 5 0 Water flow (m 3 /h) 0 0,5 1 1,5 2 2,5 3 8 7 6 5 4 3 2 1 0 0 5 10 15 Water flow (US gpm) Head (m) Max. Speed Av. Speed Min. speed FLOW HEAD P1 I1 Qm3/h H mwg Watts Amps 1,00 4,7 74,3 0,64 1,00 2,1 64,7 0,59 1,00 0,5 43,7 0,41 Star S 21 U Head (ft) 25 20 15 10 5 0 Water flow (m 3 /h) 0 0,5 1 1,5 2 2,5 3 0 0 5 10 15 Water flow (US gpm) 8 7 6 5 4 3 2 1 Head (m) Max. Speed Av. Speed Min. speed FLOW HEAD P1 I1 Qm3/h H mwg Watts Amps 1,00 5,0 82,4 0,71 1,00 3,2 67,3 0,62 1,00 1,3 49,3 0,45 10