HOYMILES MICRO-IVERTER MI-250

Similar documents
HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

MICRO-INVERTER OMNIKSOL M-300

Product manual Rapid Shutdown (RSD) system for residential and small commercial

Installation Manual AXITEC SOLAR MODULES

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Switching DC Power Supply

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

HD UNIT INSTALLATION & SERVICE BOOKLET 3-7

i-energy i-micro inverter GT260

High Frequency SineWave Guardian TM

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Operating Instructions CYR52

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Philadelphia Solar Installation and Operation Manual

INSTALLATION MANUAL.

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

230VAC Power Inverter 400W Owner s Manual

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

User Manual. Solar Charge Controller 3KW

STONESTAR AUSTRALIA PTY LTD

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Photovoltaic Solar Plan Review

Product Manual SP-SP-2.0-EN

MIG240UL00 Micro Inverter

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Galaxy VM. Battery Breaker Box Installation 09/

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

SCC-MPPT Solar Charge Controller

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Technical Manual. DLM Module. This manual should remain with the unit.

Solar module user manual Conergy PM 225P-250P

M Series External Battery Frame. User Guide

Multi-Mover Charger for model L25

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Power Inverter 400 MW Owner s Manual

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Owner's/Installation Manual

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Aurora Wind Interface Box

Appendix: Safety and application notes for... 15

User Manual Solar Charge Controller 3KW

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Micro Diaphragm Gas Sampling Pumps

8300 Series Installation Guidelines

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

RP Instruction Manual

SAVE THESE INSTRUCTIONS!!

Wilo-Control SC-Fire Jockey

Solar Charge Controller

CP /240-MC4 User Manual

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

SCC-MPPT Solar Charge Controller

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

Installation Manual LIGHTWAY PV MODULES. Revision Date March 30, 2013 /Applicable for IEC certified products

General Precautions. Personnel Precautions

SCC-MPPT Solar Charge Controller

EVS RP6020. Instruction Manual

LED Twister II. User manual UK Version 1.0

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Safety and Installation Instructions For Fluitecnik PV Modules

RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide

c-go 24V/6A 24V/8A 24V/12A

2016 Photovoltaic Solar System Plan Review List

User Manual Rittal PMC UPS 6kVA

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

Contents. VBHNxxxSJ40 series. VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT TM. VBHNxxxSJ40 series. VBHNxxxSJ25 series

Contents. VBHNxxxSJ40 series VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT R. VBHNxxxSJ25 series VBHNxxxSJ40 series

CALTRAP INSTALLATION AND OPERATIONS MANUAL

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

Safety and Installation Instructions

Transcription:

HOYMILES MICRO-IVERTER MI-250

TECHNICAL MANUAL CONTENTS INTRODUCTION... 3 SAFETY... 4 SYMBOL ILLUSTRATION... 4 INSTALLATION WARNINGS... 5 PREPARE FOR INSTALLING... 6 TRANSPORT AND INSPECT... 6 CHECK INSTALLATION ENVIRONMENT... 7 INSTALLATION POSITION... 7 MOUNTING AND WIRING... 8 INSTALLING DIAGRAM... 8 ASSEMBLY INSTRUCTION... 9 Step 1. Install Micro-inverter... 9 Step 2. Connect AC Cable of Micro-inverter... 9 Step 3. Protecting Unused Ends... 9 Step 4. Connecting AC-TRUNK Cables to Junction Box... 10 Step 5. Drawing System Map... 11 Step 6. Install Photovoltaic Modules... 11 Step 7. Install CDD... 12 MAINTENANCE GUIDE... 13 ROUTINE MAINTENANCE... 13 STORAGE AND DISMANTLING... 14 APPENDIX... 15 TECHNICAL DATA... 15 EFFICIENCY CURVES... 错误! 未定义书签 TEMPLATE FOR MAP OF MICRO-INVERTER INSTALLATION... 16

INTRODUCTION Thank you for using MI-250 Micro-Inverter! This Micro-Inverter system is the world s most technologically advanced inverter system with benefits of efficient, flexible, safe and reliable for use in utility-interactive applications. This system is composed of a group of Micro-inverters that convert direct current (DC) into alternating current (AC) and feeds it into the electric grid. Different from systems that photovoltaic modules are subdivided into strings and controlled by one or several inverters, this system is built for the incorporation of a Micro-inverter for each photovoltaic module. Each Micro-inverter works independently of the others to guarantee maximum power of each photovoltaic module. This setup enables direct control over the production of a single photovoltaic module, consequently improving the flexibility and reliability of the system. This manual contains important instructions for the MI-250 Micro-inverter and must be read in its entirety before installing or commissioning the equipment. For safety, only qualified technician, who has received training or has demonstrated skills can install and maintain this Micro-inverter under the guide of this document. There are two models of the Micro-inverter, delineated by the maximum output power. This document applies only to the inverter models listed in Table 1 below: Table 1 Output Power 250W 500W Model Number MI-250 MI-500 Hoymiles can provide commissioning. Please contact Hoymiles customer service at 086-0571-89775158. More information at website: http://www.hzconverter.com/cn/index.php

SAFETY IMPORTANT SAFETY INSTRUCTIONS! PLEASE KEEP THIS INTRODUCTION IN A SAFE PLACE! SYMBOL ILLUSTRATION The safety symbols used in this manual are list below and illustrated in detail. Symbol Usage Indicates a hazardous situation that can result in deadly electric shock hazards, other serious physical injury, or fire hazards. Indicates directions which must be fully understood and followed in entirety in order to avoid potential safety hazards including equipment damage or personal injury. This points out that the described operation must not be carried out. The reader should stop, use caution and fully understand the operations explained before proceeding.

INSTALLATION WARNINGS The MI-250/500 Micro-inverter is designed and tested according to international safety requirements (IEC 62109-1/2; VDE4105/0126). However, certain safety precautions must be taken when installing and operating this inverter. The installer must read and follow all instructions, cautions and warnings in this installation manual All operations including transport, installation, start-up and maintenance, must be carried out by qualified, trained personnel. Before installation, check the unit to ensure absence of any transport or handling damage, which could affect insulation integrity or safety clearances. Choose installation location carefully and adhere to specified cooling requirements. Unauthorized removal of necessary protections, improper use, incorrect installation and operation may lead to serious safety and shock hazards or equipment damage. Before connecting the Micro-inverter to the power distribution grid, contact the local power distribution grid company to get appropriate approvals. This connection must be made only by qualified technical personnel. It is the responsibility of the installer to provide external disconnect switches and Overcurrent Protection Devices (OCPD). Only one photovoltaic module can be connected in the input of the inverter. Do not connect batteries or other sources of power supply. The inverter can be used only if all the technical characteristics are observed and applied. Do not install the equipment in adverse environment conditions such as flammable, explosive, corrosive, extreme high or low temperature, and humid. Do not use the equipment when the safety devices do not work or disabled. Use personal protective equipment, including gloves and eye protection when working. Inform the manufacturer about non-standard installation conditions. Do not use the equipment if any operating anomalies are found. Avoid temporary repairs. All repairs should be carried out using only qualified spare parts, which must be installed in accordance with their intended use and by a licensed contractor or authorized Hoymiles service representative. Liabilities arising from commercial components are delegated to their respective manufacturers. Anytime the inverter has been disconnected from the power network, use extreme caution as some components can retain charge sufficient to create a shock hazard. Prior to touching any part of the inverter use care to ensure surfaces and equipment are at touch safe temperatures and voltage potentials before proceeding. Hoymiles accepts No liability for damage from incorrect or careless operation

PREPARE FOR INSTALLING TRANSPORT AND INSPECT Hoymiles packages and protects individual components using suitable means to make the transport and subsequent handling easier. Transportation of the equipment, especially by road, must be carried out by suitable ways for protecting the components (in particular, the electronic components) from violent, shocks, humidity, vibration, etc. Please dispose the packaging elements in appropriate ways to avoid unforeseen injury. It is the customer s responsibility to examine the condition of the components transported. Once receiving the Micro-inverter, it is necessary to check the container for any external damage and verify receipt of all items. Call the delivering carrier immediately if damage or shortage is detected. If inspection reveals damage to the inverter, contact the supplier, or authorized distributor for a repair/return determination and instructions regarding the process. Components supplied by Hoymiles are list in Table 2 below: Table 2 Code Description AC trunk end cap End cap for 10 AWG AC cable

CHECK INSTALLATION ENVIRONMENT Installation of the equipment is carried out based on the system design and the place in which the equipment is installed. The installation must be carried out with the equipment disconnected from the grid (power disconnect switch open) and with the photovoltaic modules shaded or isolated. See Appendix: Technical Data to check the environmental parameters to be observed (degree of protection, temperature, humidity, altitude, etc.) To avoid unwanted power derating due to an increase in the internal temperature of the inverter, do not expose it to direct sunlight. To avoid overheating, always make sure the flow of air around the inverter is not blocked. Do not install in places where gasses or flammable substances may be present. Avoid electromagnetic interference that can compromise the correct operation of electronic equipment. INSTALLATION POSITION When choosing the position of installation, comply with the following conditions: Install only on structures specifically conceived for photovoltaic modules (supplied by installation technicians). Install Micro-inverter underneath the photovoltaic modules so that they work in the shade. If this condition cannot be met, the inverter could undergo derating. PV Module Micro Inverter Fig.1. Installation position of Micro-inverter

MOUNTING AND WIRING INSTALLING DIAGRAM System Schematic Diagram AC Distribution Panel Red:Live Black:Neutral Green:Ground Junction Box PV Module DC AC Micro inverter AC Cable DC AC Fig.2. 230Vac single phase Assembly Diagram PV Module AC End Cap Bracket AC Cable DC Cables From Micro Inverter PV Module Junction Box Fig.3. Assembly Illustration

ASSEMBLY INSTRUCTION Step 1. Install Micro-inverter Mark the approximate center of each photovoltaic module on the frame and install the Micro-inverter with the logo side facing downwards. Observe the certification documents concerning the maximum number of Micro- inverters permitted for installation at each cable section! The Micro-inverter must be under the module, out of long-term exposure to direct sunlight or rain. Step 2. Connect AC Cable of Micro-inverter Connect the AC cable of the Micro-inverters. The connectors are coupled correctly when two clicks are heard. Step 3. Protecting Unused Ends Fig.4. Connect AC Cable of Micro-inverter The unused ends of the AC-TRUNK cable must be terminated with the proper end. Fit the appropriate AC-TRUNK END CAP on the unused ends of the AC-TRUNK cable. AC End Cap Fig.5. Unused Ends

Step 4. Connecting AC-TRUNK Cables to Junction Box Connect the AC-TRUNK cables coming from the MICRO inverters to the junction box. Close the junction box after the wiring is complete. Ensure that the seal is tight. Fig.6. Junction Box To prevent electrical hazards, all the connection operations must be carried out with the equipment disconnected from the grid. All the external connections to the insulated junction box (caps, adapters, etc.) must be made with securely-sealed Hoymiles components.

Hoymiles AC cables from the Micro-inverters have three conductors with different colors to identify the function of each conductor: Red: Live Black: Neutral Yellow-Green: Ground Pay special attention and ensure not to reverse the phase with the neutral! The installation technician is responsible for selecting a junction box with the appropriate dimensions and insulation. The installation technician is responsible for selecting a cable running between the junction box and the load distribution panel with the appropriate length and cross section. Step 5. Drawing System Map Draw a map of the system, affixing the extra label that comes attached to each inverter, on the appropriate position on the diagram (found in the Appendix of this manual). Fig.7. System Map Step 6. Install Photovoltaic Modules Install the photovoltaic modules, and connect the DC cables of the modules to the corresponding DC input side of the Micro-inverter.

DC Cable From PV Module DC Cable From Micro Inverter Fig.8. Connect DC Cables The recommended installation need keeping the Micro-inverters underneath the photovoltaic modules, so that the Micro-inverters can operate in the shade. Direct sunlight may cause damage to the Micro-inverters. Each module must be connected to the Micro-inverters with a DC cable having a length of less than 3m. Step 7. Install CDD Install the CDD (Concentrator Data Device) and commission

MAINTENANCE GUIDE ROUTINE MAINTENANCE Only authorized personnel are allowed to carry out the maintenance operations and are responsible to report any anomalies. Always use the personal protective equipment provided by the employer when carry out the maintenance operation. During normal operation, check that the environmental and logistic conditions are correct. Make sure that the conditions have not changed over time and that the equipment is not exposed to adverse weather conditions and has not been covered with foreign bodies. DO NOT use the equipment if any problems are found, and restore the normal conditions after the fault removed. Conduct an annual inspection on various components, and clean the equipment with a vacuum cleaner or special brushes. Do not attempt to dismantle the Micro-inverter or make any internal repairs! In order to preserving the integrity of safety and insulation, the Micro-inverters are not designed to allow internal repairs! The AC output wiring harness (AC drop cable on the Micro- inverter) cannot be replaced. If the cord is damaged the equipment should be scrapped. Maintenance operations must be carried out with the equipment disconnected from the grid (power switch open) and the photovoltaic modules obscured or isolated, unless otherwise indicated. For cleaning, DO NOT use rags made of filamentary material or corrosive products that may corrode parts of the equipment or generate electrostatic charges. Avoid temporary repairs. All repairs should be carried out using only genuine spare parts.

STORAGE AND DISMANTLING If the equipment is not used immediately or is stored for long periods, check that it is correctly packed. The equipment must be stored in well-ventilated indoor areas that do not have characteristics that might damage the components of the equipment. Take a complete inspection when restarting after a long time or prolonged stop. Please dispose the equipment properly after scrapping, which are potentially harmful to the environment, in accordance with the regulations in force in the country of installation.

APPENDIX TECHNICAL DATA Model MI-250 MI-500 Input data(dc) Recommended PV module 200-310 200-310 power (STC) range (W) MPPT voltage range (V) 27~48 27~48 Operating voltage range (V) 18~60 18~60 Maximum input voltage (V) 60 60 Maximum input current (A) 10 10 2 Output Data (AC) Rated output power (W) 250 500 Rated output current (A) 1.08 2.16 Nominal output voltage 230 230 Nominal frequency 50 50 Power factor >0.99 >0.99 Output current harmonic <3% <3% distortion Mechanical Data Ambient temperature range ( ) -40 ~ +65-40 ~ +65 Operating temperature range ( ) -40 ~ +85-40 ~ +85 Dimensions (W H D mm) 178 153 29 240 155 29 Weight (kg) 1.5 2.2 Enclosure rating IP67 IP67 Cooling Natural convection No fans Natural convection No fans Features Communication Wireless Wireless Warranty 15~25 years 15~25 years

TEMPLATE FOR MAP OF MICRO-INVERTER INSTALLATION Customer Information: Please affix the extra label that comes from each inverter, on the appropriate position on this diagram. HANGKAI GROUP HOYMILES 1 2 3 4 5 A B C D E