Valve bodies type RA-N with integrated presetting

Similar documents
Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

High Capacity Valve Body, Type RA-G

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

High capacity valve body, type RA-G

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

X-tra Collection for designer radiators and bathroom towel rails

Floor heating system, heating circuit with FHV-A in flow.

X-tra Collection for designer radiators and bathroom towel rails

Manual presetting valve MSV-C

Manual presetting valves LENO MSV-BD

Manual Presetting Valves LENO MSV-B

Flow controller (PN 25) AVQ - return and flow mounting

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Automatic balancing valves ASV-PV DN (3rd gen.)

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Flow-compensated temperature controller AVTQ DN 15

Pressure relief controller AVA (PN 25)

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Assisted lift operated 2/2-way solenoid valves Type EV251B

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Horizontal Distribution Units - HDU Multi-port

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

FHV control valves are flexible to use, easily installed and are available in two versions:

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

SonoSensor 30 Ultrasonic flow sensor

ON/OFF zone valves AMZ 112, AMZ 113

Integrated valves Series 3

Mikrotherm F. Manual Radiator Valves With presetting

Regutec F. Return Lockshield Radiator lockshield

SonoMeter 30 Energy Meters

Changing pistons APP 21-43

Actuator type ABNM with Theft Protection, 0-10 V Proportional

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

Premounted Midi Shunts

RTL. Floor Heating Controller Return temperature limiter with and without presetting

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

SSM Floor Heating Manifold

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

Oil pump type RSA. Catalogue 1. Burner Components

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Flow controller (PN 25) AVQ - return and flow mounting

RADIATOR VALVE ACCESSORIES

Thermostatic valve Type AVTA

Crankcase pressure regulator Type KVL

Steel butterfly valves SBFV (PN 16/25)

Crankcase pressure regulator Type KVL

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

XV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

SonoMeter 30 Energy Meters

Thermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Servo-operated 2/2-way solenoid valves Type EV220A

Changing pistons APP and APP 16-22

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.

The precise step to take

Technote. CirCon/TemCon - thermostatic valves for domestic hot water. Application. Advantages. Functions.

TDU.3 floor distribution unit SK

PAHT pump PAHT X

Static Balancing Valve

Thermostatic radiator valves with presetting

2018 High Performance Check Valves for liquid and gaseous media

APP S pumps APP S / APP S / APP S 21-38

R134a R134a R13. 4a R134a R134a R134

Extensions to a comprehensive product range

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

V2000Kx KV type TRV Body

Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size

Tel: +44 (0) E mail: Web: Data sheet. APP pumps APP ro-solutions.com

STAF-SG. ANSI flanges. Balancing valves DN

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Technical information Thermostatic radiator valves

Fan-coil valves Series

Disassembling and assembling isave 21

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

SonoSelect and SonoSafe energy meters

k VS DN (mm) Connections ( C) (m 3 /h)

Infocal 9 Energy calculator for heating and cooling applications

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

Transcription:

Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000 series. To be able to distinguish between other valve bodies of the RA 2000 series the protective cap is equipped with a red setting screw. The valve bodies are fitted with a kv limiting device for pre-setting of max. water flow. Compression fittings for 15 mm, 10 mm or 8 mm copper tube are available for valve body RA-N with 3/8" and 1/2" BSP connections. The valve body RA-N is used in two-pipe heating systems and is available with the following setting ranges for max. water flow: RA-N 10: kv = 0.04-0.56 m3/h RA-N 15: kv = 0.04-0.73 m3/h RA-N 20/25: kv = 0.10-1.04 m3/h Valve bodies are manufactured from brass with nickel plating. The pressure pin of the gland seal is of chrominium steel and works in a lifetime lubricated O-ring. The complete gland assembly can be replaced without draining down the system. Should water treatment be used it is essential that dosing instructions of the manufacturer are strictly observed. It is recommended that formulations containing mineral oil are avoided. The valve bodies are supplied with a protective cap and adjusting screw which can be used for manual regulation during the construction phase. The protective cap must not be used as a manual shut off device. A special manual shut off device (code no. 013G5000) should be used. Approved to EN 215 Quality Standards Danfoss Heating Solutions All Danfoss RA 2000 radiator thermostats are manufactured to the highest standards, and are approved to the European standard EN 215 and dimension standard HD 1215, which superseeds BS 6284 1983. All Danfoss radiator thermostats are manufactured in factories, assessed and certified by BSI against BS 5750 (ISO 9000). VDTYA202 Danfoss 12/2010 1

Principles Data and Ordering Type RA-N 10 RA-N 15 RA-N 20 RA-N 25 Connections Pre-setting Design Inlet Outlet k v -max. 1) (m 3 /h at Δp = 1 bar) k vs Rp R 1 2 3 4 5 6 7 N N Angle 3/8 3/8 0.04 0.08 0.12 0.19 0.25 0.33 0.38 0.56 0.65 Straight 3/8 3/8 0.04 0.08 0.12 0.19 0.25 0.33 0.38 0.56 0.65 Horiz. angle 3/8 3/8 0.04 0.08 0.12 0.19 0.25 0.33 0.38 0.56 0.65 Right angle 3/8 3/8 0.04 0.08 0.12 0.19 0.25 0.33 0.38 0.56 0.65 Left angle 3/8 3/8 0.04 0.08 0.12 0.19 0.25 0.33 0.38 0.56 0.65 Angle 1/2 1/2 0.04 0.09 0.16 0.25 0.36 0.43 0.52 0.73 0.90 Straight 1/2 1/2 0.04 0.09 0.16 0.25 0.36 0.43 0.52 0.73 0.90 Horiz. angle 1/2 1/2 0.04 0.09 0.16 0.25 0.36 0.43 0.52 0.73 0.90 Right angle 1/2 1/2 0.04 0.09 0.16 0.25 0.36 0.43 0.52 0.73 0.90 Left angle 1/2 1/2 0.04 0.09 0.16 0.25 0.36 0.43 0.52 0.73 0.90 Angle 3/4 3/4 0.10 0.15 0.17 0.26 0.35 0.46 0.73 1.04 1.40 Straight 3/4 3/4 0.10 0.15 0.17 0.26 0.35 0.46 0.73 1.04 1.40 Horiz. angle 3/4 3/4 0.16 0.20 0.25 0.35 0.47 0.60 0.73 0.80 1.00 Angle 1 1 0.10 0.15 0.17 0.26 0.35 0.46 0.73 1.04 1.40 Straight 1 1 0.10 0.15 0.17 0.26 0.35 0.46 0.73 1.04 1.40 Type RA-N 10 RA-N 15 RA-N 20 RA-N 25 Design Max work. press. Max diff. 2 ) press Test Max work. temp. bar bar bar C Code no. Angle 10 0.6 16 120 013G0011 Straight 10 0.6 16 120 013G0012 Horiz. angle 10 0.6 16 120 013G0151 Right angle 10 0.6 16 120 013G0231 Left angle 10 0.6 16 120 013G0232 Angle 10 0.6 16 120 013G0013 Straight 10 0.6 16 120 013G0014 Horiz. angle 10 0.6 16 120 013G0153 Right angle 10 0.6 16 120 013G0233 Left angle 10 0.6 16 120 013G0234 Angle 10 0.6 16 120 013G0015 Straight 10 0.6 16 120 013G0016 Horiz. angle 10 0.6 16 120 013G0155 Angle 10 0.6 16 120 013G0037 Straight 10 0.6 16 120 013G0038 2 VDTYA202 Danfoss 12/2010 Danfoss Heating Solutions

1) The k v -value indicates the water flow (Q) in m 3 /h at a pressure drop ( p) across the valve of 1 bar; At setting N the k v -value is stated according to EN 215, at X P = 2K i.e. the valve is closed at 2 C higher room temperature. At lower settings the X P value is reduced to 0.5K of the setting value1. The k vs -value states the flow Q at a maximum lift, i.e. at fully open valve at setting N. 2) Working pressure = static + differential pressure. The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 30 to 35 kpa. The differential pressure can be reduced by the use of the Danfoss differential pressure regulators types AVD, AVDL, AVDS, IVD or ASV-P. Accessories Product Dimension For valve body Code no. Gland seal - All RA valves 013G0290 Rp 3/8 x Ø10 mm 013G4100 RA-N 10 Rp 3/8 x Ø12 mm 013G4102 Compression fitting for steel and copper tubes Rp 1/2 x Ø10 mm 013G4110 Rp 1/2 x Ø12 mm RA-N 15 013G4112 Rp 1/2 x Ø15 mm 013G4115 All accessories comes in boxes of 10 pcs. Setting Presetting area Reference mark Operating Principle 1. Gland seal 2. O-Ring 3. Pressure pin 4. Seal 5. Regulation spring 6. Setting dial 7. Valve body 8. k v -nozzle The radiator thermostats consist of the thermostatic elements of the RA 2000 series and the valve body RA-N. The element and the valve body are ordered separately. A clamping band with Allen screw ensures a simple, firm connection between element and valve body. The gland seal of the valve can be changed in operation, i.e. with water and pressure on the system. Danfoss Heating Solutions VDTYA202 Danfoss 12/2010 3

Valve body and other metal parts Kv-limiter O-ring Valve cone Pressure pin and valve spring Nozzle Ms 58, brass PPS EPDM NBR Chrome steel PP The valve bodies are nickle-plated on the outside. Max ambient temperature 60 C Max medium temperature 120 C Max working pressure 10 bar Test pressure 16 bar Capacities RA-N 10 4 VDTYA202 Danfoss 12/2010 Danfoss Heating Solutions

RA-N 15 Sizing example: Required heat: Cooling across radiator: Flow through radiator: 0.7 kw 20 C Pressure drop across valve: p = 1 mwg Valve setting: RA-N 10 2 RA-N 15 2 RA-N 20/25 1 Alternatively the setting can be read directly in the table "Data and Ordering". Danfoss Heating Solutions VDTYA202 Danfoss 12/2010 5

RA-N 20 UK 6 VDTYA202 Danfoss 12/2010 Danfoss Heating Solutions

RA-N 20, 25 Note As with any device which imposes a pressure drop in the system, noise may occur under certain flow/ pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 30-35 kpa (3-3.5 mwg). Dimensions Straight valve body with thermostatic sensor RA 2990 Angle valve body with thermostatic sensor RA2992 Danfoss Heating Solutions VDTYA202 Danfoss 12/2010 7

UK-angle valve body with thermostatic sensor RA 2990 Right mounted angle valve Type ISO 7-1 Arc. flats L 1 L 2 L 3 L 4 L 5 L 6 L 7 L 8 L 9 L 10 DN D d 2 S 1 S 2 RA-N 10 10 R p 3/8 R 3/8 50 75 24 49 20 47 96 27 52 22 22 27 RA-N 10 UK 10 R p 3/8 R 3/8 59 108 26 51 22 22 27 RA-N 15 15 R p 1/2 R 1/2 50 82 26 53 23 47 96 30 58 26 27 30 RA-N 15 UK 15 R p 1/2 R 1/2 60 109 29 57 27 27 30 RA-N 20 20 R p 3/4 R 3/4 65 98 30 63 26 52 101 32 37 RA-N 20 UK 20 R p 3/4 R 3/4 61 110 34 66 30 32 37 RA-N 25 20 R p 1 R 1 90 125 40 75 34 52 101 41 46 Danfoss A/S Heating Solutions Haarupvaenget 11 8600 Silkeborg Denmark Phone:+45 7488 8000 Fax: +45 7488 8100 Email: ComfortControlsInternet@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 VDTYA202 Danfoss 12/2010 Danfoss Heating Solutions