Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

Similar documents
HOT AIR GUN MODEL No. CHG 1500B Part No

OPERATION & MAINTENANCE INSTRUCTIONS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

ORIGINAL INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

LEAD ACID BATTERY CHARGER

28W WORK LAMP Model: CTL28 Part No:

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE PUMP HSE RANGE

CFT24 &CFT230 PART NOS:

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

9 (230mm) ANGLE GRINDER Model No. CAG232

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

SUBMERSIBLE WATER PUMP

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

SUBMERSIBLE WATER PUMP

VARIABLE SPEED JIG SAW

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS

BENCH GRINDER MODEL CBG6RP OPERATING & MAINTENANCE INSTRUCTIONS 0101

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

OPERATION & MAINTENANCE INSTRUCTIONS

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

1200W INVERTER GENERATOR

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATING & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

BENCH GRINDER WITH LIGHT AND WIRE WHEEL MODEL NO: CBG8370LW

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

CORDLESS IMPACT WRENCH

BENCH GRINDER WITH WIRE BRUSH WHEEL, LIGHT AND WHEEL DRESSER MODEL NO: CBG6250LW

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

VARIABLE SPEED JIG SAW

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

12V OIL & DIESEL PUMP MODEL NO: CFTP12

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

ELECTRIC CAR POLISHER

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

POND PUMP Model Nos:SPP3 & SPP6 0200

BATTERY/BOOSTER CHARGER. Model No: BC100N Part No: OPERATING & MAINTENANCE INSTRUCTIONS

18V CORDLESS DRILL MODEL NO: CON18LiC

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

OPERATING & MAINTENANCE INSTRUCTIONS

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

BENCH GRINDER MODEL NO: CBG6250

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

PROFESSIONAL CORDLESS IMPACT WRENCH

1 ELECTRIC WATER PUMP

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

BATTERY CHARGER-STARTER

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

12 amp RMS Battery Charger

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

18V CORDLESS STAPLER/NAILER

ELECTRIC IMPACT WRENCH

ELECTRIC IMPACT WRENCH

18V CORDLESS COMBI DRILL MODEL NO: CON18NI

BENCH GRINDER WITH LIGHT AND WHEEL DRESSER

SUBMERSIBLE WATER PUMP

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

1/2 HP SUMP PUMP OWNER'S MANUAL

SWIMMING POOL PUMPS Models SPP07, SPP10 & SPP15 Part Nos: , &

Cordless Rechargeable Saw Instructions for Use

SPOT WELDER. Models CSW11 & CSW11T OPERATING & MAINTENANCE INSTRUCTIONS. Part No &

720W PORTABLE GENERATOR

KING 130 HOT WASHER Part No Product Serial No:...

ELECTRIC ENGRAVER 15W WARRANTY INSTRUCTION MANUAL SPECIFICATIONS WHAT S IN THE BOX. ozito.com.au. Electric Engraver

ENGINE DRIVEN 3 FULL TRASH PUMP

Car Battery Charger Instructions for Use

1100W PORTABLE GENERATOR

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

6 x 10 Belt Disc Sander

12V Oil Extractor Pump

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

COLD WATER WASHER OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. ELS145, 145R & ELS160R. Part Nos , &

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

RMT1201. ORIGINAL INSTRUCTIONS Cordless Multi-Tool

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

RECHARGEABLE SPOTLIGHT

CEMENT MIXERS & MACHINERY USER & WARRANTY GUIDE. Electric and Petrol Models

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

RECHARGEABLE SPOTLIGHT

Battery Charger JCB-FCH12Li

MONZA OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

Transcription:

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos: 7150710 7150715 USER INSTRUCTIONS ORIGINAL INSTRUCTIONS 1117

Thank you for purchasing this CLARKE Bore Hole Pump, which is designed for use in a domestic environment only. Please read this instruction leaflet thoroughly and follow the instructions carefully, in doing so you will ensure the safety of yourself and that of others around you, this will also ensure that the Bore Hole Pump will give you long and satisfactory service. Please keep these instructions in a safe place for future reference. CLARKE GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which is was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. ENVIROMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility. Please Note that details and specifications herein, are correct of time of going to print. However CLARKE International reserve the right to change specifications at any time without prior notice. Copyright CLARKE International All rights Reserved 2006. 2

GENERAL SAFETY PRECAUTIONS WARNING: As with all machinery, there are certain hazards involved with their operation and use. Exercising respect and caution will considerably lessen the risk of personal injury. However, if normal safety precautions are overlooked or ignored, personal injury to the operator or damage to property, may result. ALWAYS learn the machine s applications, limitations and specific potential hazards peculiar to it. Read and become familiar with the entire operating manual. ALWAYS ensure that the local supply voltage corresponds with the supply information on the machine s data plate. ALWAYS check for damage before use, any damaged part should be checked to ensure that it will operate properly and perform it s intended function. Check for alignment of moving parts, breakage of parts, mountings, and any other condition which may effect the machine s operation. Any damage should be properly repaired or the part replaced. If in any doubt DO NOT use the machine. Consult your local CLARKE dealer. ALWAYS keep children away. All visitors should be kept at a safe distance from the work area, especially whilst operating the machine. ALWAYS maintain machine in top condition. Keep the machine clean for best performance. Follow maintenance instructions. ALWAYS handle with extreme care, do not carry the machine by it s electrical cable, or yank the cable to disconnect it from the power supply. ALWAYS concentrate on the job at hand, no matter how trivial it may seem. Be aware that accidents are caused by carelessness due to familiarity. ALWAYS wear proper apparel. Loose clothing or jewellery may get caught in moving parts. Wear protective hair covering to contain long hair. ALWAYS remove plug from the electrical outlet when adjusting, changing parts, or when working on the machine. ALWAYS use recommended accessories, the use of improper accessories could be hazardous. ALWAYS guard against electric shock. Safety can be further be improved by using a residual current device (RCD). ALWAYS ensure that the power supply used to power the machine is connected to an efficient grounding system. ALWAYS store the machine out of the reach of children, DO NOT allow children to operate the machine. NEVER operate the machine when under the influence of drugs, alcohol or any medication. NEVER leave the machine running unattended. Turn power OFF. Do not leave the machine until it comes to a complete stop. NEVER force the machine, it will do a better and safer job at the rate for which it was designed. DO NOT use the machine if the electrical cable, plug or motor is in poor condition. 3

SAFETY PRECAUTIONS FOR BORE HOLE PUMPS ONLY use the pump for it s intended applications (refer to setup & operation). ALWAYS protect the power supply plug from getting wet, the plug must be accessible when the pump is running. ALWAYS ensure that nobody is in contact with the water in which the pump is submerged. ALWAYS protect the pump and pipe from frost, drain the pump and pipe and store in a protected location. ALWAYS ensure that the weight of the pump is borne by the rope and not the main supply cable or the delivery pipe. DO NOT carry the bore hole pump by the mains supply cable. DO NOT make any modifications to the pump, or tamper with it in any way. NEVER operate the pump with the delivery port closed or obstructed. TECHNICAL SPECIFICATION Model No: CBB75 CBB100 Part No: 7150710 7150715 Supply Voltage/Frequency: 230V/50Hz 230V/50Hz Input Wattage: 750W 1000W Mains Supply Cable Length: 15M 15M Flow Rate: 60 litres/min 80 litres/min Max. Immersion Depth: 15M 15M Max Head: 55M 60M Max. Temperature: 35 O C 35 O C Max. Sand Content: 90g/m 3 90g/m 3 Max. Size of Suspended Particles 2mm dia 2mm dia Number iof Impellers: 7 8 Delivery Diameter: 1 inch 1 inch Pump Diameter: 98mm 98mm Rope Length: 15M 15M Weight 10.3kg 10.8kg 4

ELECTRICAL CONNECTIONS This product is provided with a standard 13 amp, 230 volt (50Hz) BS1363 plug, for connection to a standard, domestic electrical supply. Should the plug need replacing at any time, ensure that a plug of identical specification is used. WARNING: Should it ever be necessary to change the plug, the wires in the mains lead should be wired according to the following colour code: BLUE - NEUTRAL BROWN - LIVE GREEN & YELLOW - EARTH Connect the BLUE coloured wire to the plug terminal marked with a letter N or coloured BLACK. Connect the BROWN coloured wire to the plug terminal marked with a letter L or coloured RED. Connect the GREEN & YELLOW coloured wire to the plug terminal marked with a letter E or or coloured GREEN or GREEN & YELLOW. IMPORTANT!: If this appliance is fitted with a plug which is moulded on to the electrical cable (i.e. non-rewireable) please note: The plug MUST be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is subsequently inserted into a socket outlet. NEVER use the plug without the fuse cover fitted. Should you wish to replace a detached fuse carrier, ensure that the correct replacement is used (as indicated by marker or colour code). The fuse in the plug MUST be replaced with one of the same rating (13amps) and this must be approved to BS1362. IMPORTANT!: If the pump s power supply cable is damaged it MUST be replaced by the manufacturer or an authorised service centre. IMPORTANT!: If in any doubt, do not attempt any electrical repair yourself. Consult a qualified technician. IMPORTANT!: Always use an approved cable extension suitable for the power rating of this tool (see specifications), the conductor size should also be at least the same size as the machine, or larger. When using a cable reel, ALWAYS unwind the cable completely. 5

SETUP AND OPERATION This bore hole pump is designed to pump soft water from bore holes, wells, underground springs or storage tanks to supply single sprinkler or irrigation systems. The pump is watertight and must be submerged in water (max depth 15m). Suitable pumping liquids are: Clear water. Rain water. The pump must NOT be used to pump: Salt water. Liquid foods. Corrosive or chemical substances. Flammable, explosive or volatile liquids. Sandy or abrasive liquids. Sewerage. Liquids containing textile materials or paper fragments. SETUP: Attach the delivery pipe to the delivery port. NOTE: DO NOT install a non-return valve on the pump delivery side, as one is already built into the pump. The non-return valve prevents the pump from draining when stopped. Secure the supply cable to the delivery pipe. Secure the rope, and lower the pump into the bore hole. NOTE: the rope should bare the weight of the pump, NOT the delivery pipe or the supply cable. The pump must be positioned at least one metre above the bottom of the bore hole. Sand and other material found in pumped liquid will cause rapid deterioration of the pump and reduce it s efficiency. Before starting the pump, make sure that the delivery pipe is unobstructed and the delivery port is open. To start the pump insert the plug into the mains supply, to stop the pump remove the plug from the supply. NOTE: the pump is equipped with a thermal-amperometric motor protector. In case of overload, the motor protector shuts down the pump automatically. When the motor has cooled the pump starts up again automatically. If the motor protector steps in, it is absolutely necessary to locate and eliminate the cause of the malfunction. (refer to trouble shooting on page 6). NOTE: The water being pumped will be polluted if this pump becomes damaged and lubricant within the pump escapes. 6

MAINTENANCE WARNING: ELECTRIC SHOCK HAZARD! Before carrying out any maintenance or cleaning operations, disconnect the pump from the power supply. This pump does not require any particular maintenance and all repairs must be carried out by an authorised service centre only, however: After removing the pump from the water, drain and rinse with clean water. To clean the suction filter, use a jet of clean water. If the pump s turbines need replacement, take the pump to an authorised service centre. If the pump s power supply cable is damaged it MUST be replaced by the manufacturer or an authorised service centre. TROUBLE SHOOTING PROBLEM: The pumps motor does not start or stops suddenly after a few seconds. CAUSE: No power supply. The thermal-amperometric motor protector has deactivated the pump due to overload. Solid particles have obstructed the suction filter. PROBLEM: The pump is running but no water is being delivered. CAUSE: The pump is not sufficiently submerged. Clogged suction filter. There is no outflow of air because the delivery pipe is obstructed. TROUBLE SHOOTING: Check the electrical connections. Unplug the pump and clean it. Check the water temperature (max 35 C). Unplug the pump and clean it. TROUBLE SHOOTING: Lower the pump deeper in the water. Unplug the pump and clean it. Remove obstructions from the delivery pipe. PROBLEM: The flow rate is insufficient. CAUSE: Clogged suction filter. Diameter of external pipe is too small. Too high head. TROUBLE SHOOTING: Unplug the pump and clean it. Use a larger diameter pipe. Reduce the head. 7