Industry 4.0 Is Unthinkable Without Calibration!

Similar documents
Industry 4.0 Is Unthinkable Without Calibration!

Happily Wireless! Wireless measuring technology offers versatile application options

JUMO PEKA Process Connection Adapter

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

SITRANS P measuring instruments for pressure

Pressure transmitter UNIVERSAL CA

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Cleaning Technology DUNOS S DUNOS R DUNOS O SO EVERYTHING KEEPS FLOWING.

OPTIFLUX 6000 Technical Datasheet

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Dear Readers, Contact: Phone:

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Pressure transmitter COMPACT ECOnomic

Thermowell For sanitary applications Model TW61, for orbital welding

ISOCAL - 6 Range Europa Venus Calisto

T-smart Butterfly Valves. Made by GEA Tuchenhagen. GEA Mechanical Equipment / GEA Tuchenhagen

A Guide to Dry Block Calibration

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

In Good Shape Temperature and Pressure Measurement in Injection Molding

Plastics and Packaging Technology. Innovative solutions for your success

Continuous level sensor NSK

Simply a question of better measurement

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Pressure. Innovative solutions for the toughest requirements

How innovative valve technology can improve cooling of die casting processes

Proven to be better. Development trends in industrial rolling bearings

Thermowell For sanitary applications Model TW61, for orbital welding

HEALTH is the inestimable value to which Pharmaceutical Industry is committed.

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

Technical Information Omnigrad TST90, TET90

PFA579lift/PFA579xlift Efficient Cleaning 100% Stainless Steel Robust Industrial Design Ex Designs. Setting a New Standard in Challenging Environments

Pharmaceuticals and Biotechnology. Innovative solutions for your success

Safety technology/equipment

better measurement Simply a question of

Temperature Calibration Guide

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

JUMO LOGOSCREEN nt A new generation of paperless recorders, with pioneering functionality

Continuous level sensor NSK

Optidew Vision Optical Dew-Point Meter

Dear Reader, For industrial furnace construction JUMO offers you a range of innovative solutions for different applications.

Pressure transmitter for elevated media temperatures

Process Filtration From Pure to Sterile

Products Solutions Services. Customized Pressure Sensors and Components Made by Endress+Hauser

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

RTD Insert for Temperature Sensor omniset- TPR100

Brewery technology Innovative solutions for your success

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

White paper: Pneumatics or electrics important criteria when choosing technology

Thermowell For sanitary applications Model TW22

better measurement Simply a question of

Mini Pressure Transmitter HA7

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

The Continuing Evolution of Food Grade Lubricants

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Recording. Innovative solutions for the highest requirements

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

BATCHFLUX 5500 C Technical Datasheet

Price List 2013 In-House Repairs and Calibration

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

High Quality Pressure Gauges

UK Weighing Federation Technical Articles

Information for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Triple offset butterfly valve meets the stringent requirements of TA-Luft and ISO Advanced environmental protection the ZETRIX way!

Q&A ON EMISSIONS TESTING

SITRANS T measuring instruments for temperature

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Butterfly valves Leakage butterfly valves Ball valves

SITRANS F flowmeters SITRANS F C

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive Flow Meter FMI

NEUMO BioControl Model

Is Low Friction Efficient?

Process Filtration From Pure to Sterile

Railway Technology. Innovative solutions for your success

OPTIMASS 3000 Technical Datasheet

EFFICIENCY, HYGIENE, OCCUPATIONAL HEALTH AND SAFETY FOR PHARMACEUTICAL PRODUCTION

RTD Temperature Sensor omnigrad T -TR 470

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Selecting Weights and Certificates

Industrial furnaces. Innovative solutions for your success

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

How do things run smoothly even in rough winds?

Process Filtration From Pure to Sterile

Temperature. Innovative solutions for the highest requirements

International Palm Oil Purchasing Policy

Servo-pneumatic drive solution for welding guns. Top quality welding!

ETA-TP008 Revision 2 Effective March 1, Battery Charging

SITRANS F C. Flow sensor MC2 4/193. Overview

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Transcription:

Industry 4.0 Is Unthinkable Without Calibration! Improved plant availability through regular sensor calibration The much-discussed Industry 4.0 cannot be implemented without a clear increase in automation solutions. At the same time, this development necessitates a growing demand in high-grade sensor technology to control and monitor the increasingly complex cross-linked processes. Although they may limit the wear of the automation system, sensors are subject to a natural aging process. Only through regular calibration can the performance capability of the overall system be guaranteed. At the same time, calibration is the basic requirement for precise measurement results. For Fulda-based JUMO GmbH & Co. KG, the subject of calibration has therefore been an issue for many years. Temperature is the central measurand for many processes in the food and pharmaceutical industry. With optimally designed measurement technology, the cleaning processes of the plants and the product quality can be significantly improved. A decisive factor here is the choice of measurement probes and the correct process connection. To meet industry rules and requirements, easy sensor cleaning and regular sensor calibration must be an option. In the food and pharmaceutical industry, measuring devices subject to specific requirements are used. One such requirement focuses on the materials from which these measuring devices are made. The materials must be nonhazardous to health if the parts made from them come into direct contact with the product. Special regulations and standards exist for this purpose. Examples are the EU framework regulation for consumer products ("Regulation [EC] No. 1935/2004 on materials and articles intended to come into contact with food") or "Regulation EC No. 2023/2006 on good manufacturing practice for materials and articles intended to come into contact with food". The pharmaceutical industry is another industry in which various standards determine the use of materials. The basis here is primarily the FDA, which has created requirements especially for plastics and chemicals in Title 21 of the CFR (Code of Federal Regulations). Furthermore, Title 21 of the CFR also includes guidelines for "Current Good Manufacturing Practice." However, the ASME (American Society of Mechanical Engineers) has also defined requirements for materials and the quality of materials coming into contact with the medium in its standard for "Bioprocessing Equipment." 1

Calibration is becoming more important The motivation of customers from the food and pharmaceutical industry to calibrate sensors varies. Quality assurance models that take the abovementioned rules as basic principles are frequently the decisive factor. However, this may also be in-house objectives. Examples are the burden of proof in the event of a complaint or more cost-effective production on the basis of quality assurance measures and the associated reduction in costs. Ultimately, calibrated sensors also provide the user with a high degree of process reliability. Increased quality consciousness, improved measurement technology, and in particular quality assurance systems such as DIN ISO 9000 have further increased the importance of process documentation and monitoring of measurement equipment. A particularly stringent requirement arises from the standard DIN ISO 9001/9004 for test equipment monitoring. This means that the suppliers and manufacturers of products subject to temperature-relevant processes are obliged to check all test equipment that may affect the product quality before use or at specified intervals. As a rule, this is done using calibrations performed in accordance with the national standards. Due to the high demand for calibrated devices and the variety of devices to be calibrated, industry has set up and maintains calibration laboratories accredited by Germany's National Accreditation Body (Die Deutsche Akkreditierungsstelle GmbH, DAkkS). Why do sensors need to be calibrated? Regular sensor calibration is required by the International Featured Standards Food. With the IFS Food, a uniform quality assurance standard has been established that supports companies with its requirements. This standard is based on the quality management standard DIN EN ISO 9001:2008, and includes Good Manufacturing Practice (GMP) as well as HACCP principles. Version 6, Part II Section 5.4 stipulates that the measurement equipment must be checked and documented at defined intervals. Companies that are certified according to this standard must show a documented quality and food safety system during audits. For this purpose, the IFS Food defines the content requirements, the procedure, and the evaluation of the audit. In addition, it provides a requirements profile for the auditing organizations. The IFS Food standards stipulate how the various components of the quality system used by a company must be documented, implemented, maintained, and continually improved. For instance, they stipulate that in cases in which the control of process parameters (e.g. temperature, time, pressure) is a 2

deciding factor for product quality, this must be monitored and recorded continually or at appropriate intervals. In the pharmaceutical industry, in addition to the national and international pharmacopeias the EU GMP guidelines, chapter 3, point 3.40, and chapter 4, point 4.26 form the basis for regular calibration of all sensors used. For the food and pharmaceutical industry, JUMO offers the inspection and calibration of temperature measuring devices as part of your quality assurance system. JUMO has a wide range of paperless recorders in its product portfolio for recording and monitoring process parameters (Fig. 1). Figure 1: The JUMO LOGOSCREEN nt (left) and fd (right) paperless recorder. These completely record the crucial process parameters for the product and generate electronic forms for documentation, which can also be customerspecific, with the PCA3000 evaluation software. The paperless recorders can also generate an alarm at defined intervals (e.g. to represent the calibration cycle for the measurement technology that is used in the process). To guarantee precise, reproducible, and traceable calibration, JUMO established a DAkkS calibration laboratory accredited according to DIN EN ISO/IEC 17025 for the measurand temperature in 1992. JUMO also performs on-site calibrations. Temperature probes and temperature control units are quickly and easily calibrated by qualified personnel. All results are documented according to DIN EN 10204 in a manner that can be traced back to the national standards. 3

Which sensors are calibrated? To determine which sensors in a plant need to be calibrated, it must first be verified whether the sensor meets the requirements for the measuring point. For this purpose, the sensor must be designed in such a way that it is 100 % suitable for the process. In doing so, all parameters and process conditions must be considered. Furthermore, the sensor must be checked in terms of its CIP/SIP capability as well as the effort required for maintenance and calibration work. It must be installed in the process in such a way that the sensor fulfills all hygienic requirements and is easily accessible for maintenance work. Ideally the sensor should be suitable for inline calibration. In the food and pharmaceutical industry, RTD temperature probes equipped with Pt100 measurement sensors are widely used. Here, "Pt" stands for platinum this precious metal has established itself as the material for resistors in industrial measurement technology. According to DIN EN 60 751, the number 100, the nominal value, indicates that with a temperature of 0 C there is a resistance of 100 Ω. The sensors have a high degree of measuring accuracy and cover a wide measuring range from -200 to +600 C. The advantages of the devices lie in their high durability and the good reproducibility of the electrical features. For the electronic system, high-grade stainless steel heads with protection type IP67 are generally used. Sensors that have direct contact with the medium must meet specific hygienic requirements. For example, this applies to the material used, which is typically stainless steel 316 L (1.4404/1.4435) with a surface roughness 0.8 µm and 0.4 µm. If seals are used, FDA-compliant material is used in a standardized manner. In addition, resistance of the material to various cleaning agents such as caustic soda and nitric acid is required. The range of JUMO s hygienic temperature probes includes both standard devices with or without transmitter as well as compact devices that are equipped with M12 connectors and are ideal for narrow measuring points in particular. The portfolio is rounded off with a temperature switch with display and analog output. These devices are used wherever users want a display directly on the plant, and at the same time want to actuate a relay, for example, via the temperature. The calibration As part of a DAkkS calibration, the thermometer is measured at different temperatures. Using the measurement data, characteristic parameters are calculated and a certificate is issued on the measurements that are carried out. Here it is important that the used temperature probe can be calibrated. 4

This includes, in particular, testing the nominal value stability after annealing in the active temperature range as well as testing the leakage resistance. If a temperature probe does not satisfy these conditions, calibration is refused. At JUMO, DAkkS calibration certificates can, for example, be issued for RTD temperature probes, thermocouples, measuring chains, data loggers, and temperature block calibrators in the measuring range between -80 and +1,100 C. Figure 2: The JUMO DAkkS laboratory for temperature The calibration certificate The calibration certificate documents all measurements, the corresponding measurement conditions, and the calculated measurement uncertainties. All specifications that clearly identify the test piece are included to eliminate any confusion. Upon request, the customer receives a temperature/resistance table or a temperature/thermoelectric voltage table over the entire measuring range of the test piece in 1 K steps with the associated increase values. This means that the linear interpolation between two consecutive table values is made possible. For the calibration of temperature block calibrators, the spatial and temporal temperature stability in the plant is also shown on the calibration certificate. Safe and clean Specific regulations also apply for the connection between the sensor and the production plant, known as the process connection. This concerns above all its cleaning capability: if the process connection is not easy to clean, 5

remaining pollutants can contaminate the next batch. An important aspect of good cleaning is not only choosing the correct connection, but also its correct insertion. For this purpose, regulations and standards also exist. These were developed by such organizations as the EHEDG (European Hygienic Engineering and Design Group). The PEKA process connection adapter system from JUMO is particularly userfriendly. This is available for measuring devices measuring the measurands temperature, pressure, and conductivity. PEKA means: a practical, EHEDGcompliant adapter system. The parts of the EHEDG-certified adapter system that come into contact with the product are made from 316 L stainless steel with FDA (Food and Drug Administration)-compliant seals and a standard surface roughness of Ra = 0.8 µm. Thanks to cavity-free installation and the hygienic design, the system is easy to clean and tailored specifically to the requirements of the food and pharmaceutical industry. The system s different process connections (welding socket, orbital welding socket, clamp, aseptic according to DIN 11864-1, and VARIVENT ) make it versatile to use and suitable for virtually every application. The benefits are obvious: Measuring devices can be easily replaced and unscrewed/screwed back in several times without affecting quality. The installation location is sealed with a plug designed specifically for this purpose. Thanks to the comparatively low effort required for regular calibrations, a significant amount of time and costs can be saved with this system. Calibrating a measuring chain on-site The calibration of the temperature probe alone is not enough in many cases because other components are still involved in the temperature measurement and the display that influence the measurement result. These components include connection cables for the temperature probe, the measuring point changeover switch, and evaluation electronics such as controllers, recorders, or indicators. Only an on-site calibration can evaluate all influential factors correctly and include them in the calibration result. Recently, JUMO also received the important DAkkS accreditation for the on-site calibration of temperature sensors. JUMO sets the same high quality standards for on-site calibration in the temperature block calibrators as it does in its in-house DAkkS laboratory. Different temperature block calibrators are used on-site. The accredited temperature range lies between -40 and +700 C. The smallest measurement uncertainty assigned lies between 0.25 and 2.5 K, depending on the calibration range. Alongside RTD temperature probes and thermocouples, thermometers with transmitters can also be calibrated with a direct reading. 6

Figure 3: Example of on-site calibration The installation location of the temperature probe is also a frequently underestimated influential factor. An excessively low immersion depth during the process or an unfavorable positioning can also negatively influence the temperature measurement. For on-site calibration, a calibration expert examines the installation location and can give recommendations to optimize the temperature measurement or take these into account in the calibration result. All results are documented in a calibration certificate and can be traced back to the national standards. Uses in industry and in the laboratory Thermometers are subject to an aging process known as "drift." The extent of the "drift" depends on the loads to which the thermometer is subjected during daily use as well as its design. Maximum operating temperatures, stress caused by temperature changes, and mechanical influences therefore play a decisive role. However, the user will rarely notice these changes and proceeds with incorrect values. This results in a loss of quality in development and production as well as in time-consuming product repairs. 7

Figure 4: Example of temperature test equipment Routine measurements comparing DAkkS calibrated RTD temperature probes and in-house operating thermometers are therefore highly recommended. A thermostatic bath or block calibrator is frequently used for this task. The DAkkS calibrated thermometer is used to set the temperature. The thermometer is also used to measure the output signal of the RTD temperature probes to be compared. Two calibrated thermometers should always be available for comparative measurements. A third thermometer should be kept in a safe place and should only be used to make a majority decision if a discrepancy between the other two thermometers exists. Maximum security through a maintenance concept If users wish to play it safe, a maintenance concept should be implemented for the entire plant. This involves compiling maintenance reports with qualityrelevant protocols, monitoring calibration deadlines, and replacing wearing parts in good time. JUMO offers these maintenance concepts both in-house as well as on-site. The creation of calibration certificates during maintenance intervals according to EN 10204 is also possible for complete measuring chains. 8

Summary The calibration of sensors should not be regarded as an unpleasant task, but an absolute necessity in modern production processes. Only then can optimum plant availability be ensured. The securing of investments, minimized downtimes, and the reduction of the burden on individual service staff are further advantages. Author: Christina Hoffmann Market Segment Manager Pharma and Food JUMO GmbH & Co. KG, Fulda, Germany Phone: +49 661 6003 9384 Fax: +49 661 6003 862 christina.hoffmann@jumo.net www.jumo.net 9