For BLOWER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Similar documents
For ELECTRONIC INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TO BE USED IN CONJUNCTION WITH: SERVICE GUIDE for Gage Unit

FOR GAGE UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

D-Series Blowers and Exhausters

HA/HAB Fiberglass Wall Mount Ventilators

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

Environmental Series Air Curtains

User s Manual D-Series Blowers and Exhausters

Hydraulic Transmission Jacks

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Heavy Duty Bottle Jacks

High Velocity Series Air Curtains

Low Profile Service Jack

Table of Contents. Safety... 2 Specifications... 3 Setup Parts List and Diagram Warranty Operation Maintenance

Installation Instructions

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Installation Precautions. Use Precautions. Specifications

Cincinnati, OH USA

!"" #$% "!&' ( ( ) *

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

Hydraulic Clutch Jack

WELDING FUME EXHAUSTERS & ARMS

Replacement Parts List

Component Size Weight Capacity

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

Model 90 Twin Control Unit

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Low Profile Service Jack

AC Electric Capstan Owner s Manual Installation and Operating Instructions

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Giant Cone Display Case

IMPORTANT SAFETY INFORMATION

Bag-In-A-Box Oil Pump System

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Models eged/egsd. Installation, Operation, and Maintenance Manual. Direct Drive Sidewall Propeller Fans (Exhaust and Supply)

PLINKO Instruction Manual Model #7760

Air Chain Hoist. Follow all instructions and warnings for. Capacities. 250 lbs (113 kg) 300 lbs (136 kg) 500 lbs (226 kg) 600 lbs (272 kg)

Operating Instructions & Parts Manual

Heavy Duty Engine Cranes

Tissue Master. User Manual

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Instruction Manual. Fudge Puppy Display Case

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

BCFS Belt Driven Centrifugal Filtered Supply Fans

Operating Instructions & Parts Manual

MODEL 900 IMPELLER-TYPE FLOW METER

Color Wheel Instruction Manual Model #7767

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

Owner s Manual & Safety Instructions

2SHE Series Direct-Drive Shutter Fans

Air Actuated Hydraulic Bottle Jacks

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Installation Power Management Unit Battery Cables and Battery Harness

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Air Curtain. Installation, Operating and Maintenance Instructions

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

!"" #$% "!&' ( ( ) *

OPERATION & SERVICE MANUAL DRUM (MANUAL DRUM LIFTER)

Telescopic Transmission Jacks

Manual Operated Floor Jack

HOW TO INSTALL YOUR BOV

Integrated Heating System

25 GALLON PORTABLE OIL LIFT

Owner s Manual & Safety Instructions

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Universal Bevel Drives Service Manual

TECHNICAL SERVICE MANUAL

Air Actuated Hydraulic Bottle Jack on Wheels

Operating Manual PFB-2500

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

Force Test Stands Series ES MODEL ES05

BP1204 INSTALLATION/OWNER'S MANUAL

DISC BRAKE CALIPER TOOL SET

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

SUBMERSIBLE MINI-PUMP

Fast Lift Service Jack, Low Profile

Accu-Meter Oil Pump. Instruction Manual. Model #2114. Cincinnati, OH USA. Part No Revised June 1996

PUSH BUTTON KEY CABINET

MIL-24/2600Q MIL-24/3200DQ

CUSTOM CARRIERS. Crane Carrier Company Standard Warranty

Owner s Manual, Operating Instructions Manual, and Replacement Parts Manual. Lift-Rite Hand Pallet Trucks Model SS45

Long Chassis Hydraulic Service Jacks

INSTALLATION AND OPERATIONS MANUAL POWER OPERATED TUBING STORAGE REEL MODEL TSR-P PRODUCTS, INC.

Ambient Collection System AT-3000

SDBDe, STXDe, ered* Installation, Operation, and Maintenance Manual INSTALLATION AND WIRING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES

INSTALLATION/OWNERS MANUAL

MODEL 200 MULTI-JET FLOW METER

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Low Profile Service Jack Jack Stand Combo

Positive Displacement Pump

Portable Electric/Gas Compressor Operating Instructions

DEINES MANUFACTURING CORPORATION

Transcription:

www.purafil.com FIRST IN CLEAN AIR SERVICE GUIDE For BLOWER ASSEMBLY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Purafil, Inc. 2654 Weaver Way, Doraville, Georgia, 30340, U.S.A. www.purafil.com tel: (770) 662-8545 (800) 222-6367 Purafil 2012 SrvcGde - Service Guide - BLOWER - 1 ISO 9001:2008

TABLE OF CONTENTS 1.0 PRE-INSTALLATION INSTRUCTIONS 1.1 SAFETY CONSIDERATIONS 1.2 STORAGE 2.0 ELECTRICAL CONNECTIONS 3.0 METHOD OF INTERNAL CONNECTIONS 4.0 BLOWER UNIT 4.1 LUBRICATION PROCEDURE 4.2 BELT REPLACEMENT 5.0 WARRANTY INFORMATION 6.0 TROUBLESHOOTING 7.0 BEARINGS LUBRICATION RECORD FIGURE TITLE 1 FAN ROTATION DIRECTION 2 NU-T-LINK BELT 3 BLOWER ASSEMBLY AND PARTS

1.0 PRE-INSTALLATION INSTRUCTIONS 1.1 SAFETY CONSIDERATIONS Read this Service Manual carefully. Be thoroughly familiar with the controls and the proper use of the equipment. This manual should be retained with the unit because it contains the information necessary for proper maintenance. There is a pocket envelope provided for this purpose. Attach it permanently to the unit. Keep all nuts, bolts, and screws tight to be sure the equipment is in safe working condition. CAUTION: Installer should be a trained, experienced service person. Disconnect power supply before wiring connections are made to prevent possible electrical shock of damage to equipment. Check the equipment weights to be sure that the rigging equipment can handle them safely. Be sure that the unit is balanced well in the transporting device. Never pressurize the equipment in excess of specified test pressure. Always conduct a thorough check when the installation is complete. Never enter an enclosed blower cabinet or reach into a unit while fan is running. The motors in PURAFIL equipment get very hot. This is normal and should not be regarded as a problem with the motor. However, take special care to avoid touching the hot areas. 1.2 STORAGE If the motor starter is purchased with the unit (optional) and it is to be stored with the unit, be sure to read instructions enclosed in the starter kit to prevent problems due to storage.

2.0 ELECTRICAL CONNECTIONS To allow maximum flexibility in installation of the unit, no internal electrical connections or external electrical openings have been made. A qualified electrician should connect wiring from the motor to the starter and to the supply panel. All wiring and controls should comply with current NEC and local codes. The standard unit does not have motor starter controls. Should the starter be purchased separately, the motor starter should be sized to provide proper overload protection. 3.0 METHOD OF INTERNAL CONNECTIONS The motor should be wired to the power supply according to the motor manufacturers instructions. The instructions are included with the motor. 4.0 BLOWER UNIT Refer to Figure 3 and the bearing discussion below for maintenance of the blower assembly. BEARING LUBRICATION IMPORTANT:READ THIS SECTION CAREFULLY! All bearing units are pre-lubricated with grease chosen for its chemical and mechanical stability and should be checked at least once a month. Although operating conditions vary, the optimum lubrication interval is established at every three months. Conditions such as speed, temperature, and environment may indicate shorter or longer intervals. FIGURE 1: FAN ROTATION DIRECTION Direction of Rotation

4.1 LUBRICATION PROCEDURE 1 Every 3 months, turn unit off. 2 Wipe the surface of the bearings and the grease fitting clean. 3 While rotating the shaft by hand, gently add grease* to the bearing until a slight bead forms at the seal. CAUTION: DO NOT OVER-GREASE Over-greasing will damage seals and void warranty. For normal operating conditions, lubrication requires a grease which conforms to NLGI No. 2 penetration, free from chemical impurities, such as dust, rust, metal particles, and abrasives. Lubrication is usually accompanied by a slight rise in operating temperature of the bearing, until the bearing chamber is stabilized with the proper amount of grease. 4.2 BELT REPLACEMENT Replace the NU-T-LINK belt (Size A 1/2) by following the instructions describing the illustration below. Note, the large end of belt links should be pointed in the direction of rotation. FIGURE 2: INSTALLATION INSTRUCTIONS FOR NU-T-LINK

FIGURE 3: BLOWER ASSEMBLY AND PARTS LIST Item Description Quantity 1 Weldment, Blower 1 2 Bearing, 1" 2 3 Label, Rotation Arrow 1 4 Wheel, Aluminum 1 5 Cone, Aluminum 1 6 Pop Rivets 10 7 Junction Box 1 8 Motor Mount 1 9 Motor 1 10 Belt, NU-T-LINK A 1/2, 44" 1 11 Sheave, Motor 1 12 Bolt, 5/16 x 1, Motor 4 13 Nut, Motor 5/16 4 14 Washer, Flat, Motor, 5/16 4 15 Bolt, 3/8 x 1-1/4 8 16 Washer, 3/8 8 17 Shaft 7 Key Assembly 1 18 Sheave, Blower 1 19 Nut, 3/8 8 20 Label, Quality Assurance 1

5.0 WARRANTY INFORMATION PURAFIL warrants hardware equipment manufactured by PURAFIL to be free from defects in material and workmanship under normal use and service for twelve (12) months from startup date or eighteen (18) months from shipment date. PURAFIL'S obligation under this warranty shall be limited to replacing any parts thereof which shall be demonstrated to have been defective. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. PURAFIL MAKES NO WARRANTIES AS TO MERCHANTABILITY OR AS TO THE FITNESS OF THE MERCHANDISE FOR ANY PARTICULAR USE AND SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE, DIRECTLY OR INDIRECTLY, ARISING FROM THE USE OF SUCH MERCHANDISE OR FOR CONSEQUENTIAL DAMAGES. No person, firm or corporation is authorized to assume for PURAFIL any other liability in connection with the sale of these goods. Equipment, parts and material manufactured by others and incorporated in PURAFIL equipment are warranted by PURAFIL ONLY TO THE EXTENT OF THE ORIGINAL MANUFACTURERS LIABILITY TO PURAFIL.

6.0 TROUBLESHOOTING SYMPTOM PROBLEM CHECKS/REMEDY Squeal sound coming from Belt is loose (or installed Follow instruction in Section blower section backwards) 4.2 in this manual Motor seems to be running Electrical connections may be Have an electrician compare too slowly incorrect the connections with the instructions in Section 3.0 of this manual and modify Abnormal or excessive noise coming from the bearing housing Lubrication may have been incorrectly done accordingly Review bearing lubrication instructions in Section 4.1 in this manual Bearing housing seems too warm Belt loose Same as above See Section 4.2 Same as above Note: In the event of any abnormal condition, immediately check the electrical wiring and motor rotation direction.

7.0 BEARING LUBRICATION RECORD Initial Start Up Date: Projected Lubrication Date Date Lubrication Procedure Completed

Represented By: Important Notice The information contained in this bulletin reflects the results of various testing and analytical procedures believed by PURAFIL, INC. (a USA corporation) to be useful indicators of the relative performance of air filtration systems and media. It is intended for use by persons having appropriate scientific and technical knowledge and experience, at their own risk. This bulletin does not in any way constitute a representation, warranty, promise, or guarantee by PURAFIL, INC. of the installed performance of PURAFIL media.