Installation Manual Infinity LED Light

Similar documents
SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Installation Instructions: Eco Linear High Bay

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

INSTALLATION INSTRUCTION MANUAL

ZIP LIGHT LED LUMINAIRE

INSTALLATION INSTRUCTIONS

Universal Retrofit System Installation Instructions Revised:

LDLS Self-Ballasted Linear Detachable Light System User s Manual

Rectangular Linear LED High Bay

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

ASSEMBLY INSTRUCTIONS

Scissor Lift Model : SC60 SC40 Installation Instructions

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

Installation Instructions: Eco SpunBay LED High Bays

X Cube Lift. Model: XCU 190 XCU 180 Installation Instructions

Ceiling Star Installation Instructions

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

EMERY SKY SUSPENDED LED LUMINAIRE

Corded and Cordless LED Worklight

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Mania EF1 user manual

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

The installation must only be performed by a licensed electrician. Disconnect power before installing the product or servicing it.

INTEGRID TRACK (120V) SPECIFICATIONS

LED Tri-proof Light SPEC L07G

Offshore Platform Leg Inspection Wolf Safety

Mania DC3 user manual

INSTALLATION & MAINTENANCE MANUAL HBL

INSTALLATION INSTRUCTION W Track Suspension system

Otte. erbine Frac. ctiona anuall

Air terminal devices

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

INSTRUCTION MANUAL SINKER. By HAY

COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - SUSPENDED

IMPORTANT SAFETY INSTRUCTIONS

Installation instructions for the LUX LED-GYM WAVE

Installation Manual. Low Ambient Cooling Kit. ZLABKA01A Low Ambient Cooling Kit. ZLABKA02A Low Ambient Cooling Kit

INSTALLATION INSTRUCTIONS

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions

CFP-LED Contractor Select Flat Panel. Installation Instructions

Installation and Maintenance Manual (2014)

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

L1EPH ECONO LED HIGH BAY LUMINAIRE FEATURES AND SPECIFICATIONS MOUNTING OPTIONS & ACCESSORIES OVERVIEW

General Installation Instructions LED

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

PT-1441 Cordless Drill Driver 14.4V User s Manual

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

HBDBM High Bay Series

Z8004. KDT916 S197 Performance Watts Linkage

ERGO KIT TEK01 SERIES

Linear Flexible Joint Cart Plus Single Inverted Pendulum (LFJC+SIP)

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

CAUTION. Disconnect Power

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

User s Manual and Operating Instructions

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

PBFAB DROPMEMBER V GM INSTALLATION GUIDE

PrevaLED Line High Flux

Service manual Be-Ge 3000

Color Logo use on white background only. Red: Blue: PMS Black Logo use on white background only

Installation Guide. Hazard Alert Messages. How to Obtain Additional Maintenance, Service and Product Information. Installation of the MTIS

SURFACE TRACK (120/250V) SPECIFICATIONS

INSTALLATION INSTRUCTIONS

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

MIRRORLITE RECESSED EMERGENCY LIGHTING

LED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90.

SISU DP-330 DRIVE GEAR. Maintenance Manual

INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

ASSEMBLY AND INSTALLATION INSTRUCTIONS

HP-2 / HP-6 Direct Installation Instructions Overview

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

MaxLite LED Linear HighBay Fixtures

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

With magnetic fixing With ON/OFF switch

PIL0478 ISSUE 01/ 07/16

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Operating Instructions

SB-H-XTOUR/10W3v3 SKU# Honda Crosstour

Distributed by Kincrome Group

MOTORIZED INSTALLATION INSTRUCTIONS

PNL-MS Belt Conveyor with Metal Detector

AXA DALI P20. DALI Broadcast Controller. Installation Manual

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

2017 TigerStop, LLC. Installation Guide AUTOMATION. February 2017 Mk1

Installation, Operation, and Maintenance Manual

DATA SHEET. GLV92C50501 Series. Part of the simpleled Program v1 P-1

ALL700RM-230V INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

ALL W INSTALLATION INSTRUCTIONS

Model Year: GIANT CONTACT SWITCH SEATPOST

DISCHARGER-ANALYZER BDX USER'S MANUAL

Upper Class Grille Main grille INSERT - #54127 / #54131 / #54133 / #51127 / #51131 / 51133

COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - RECESSED MOUNT

LED IMPORTANT SAFETY INSTRUCTIONS

Wheel Bearing and Wheel Hub All-Wheel Drive (AWD) Vehicles

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

Transcription:

Installation Manual Infinity LED Light

Background This manual provides guidance on installation of the Infinity LED Linear light and associated accessories. Please contact customer support with any installation questions not covered in this guide. Product Overview An exploded view of the Infinity light with power cable (p/n TL-PC2) and end cap is shown below. End cap Power cable Infinity light bar General Guidelines Confirm the overall integrity of the light fixture prior to installation. Maintain at least 8 inches (0.2 meters) between the light fixture and any combustible materials. Keep the light fixture away from sources of heat. The Infinity LED light is an indoor luminaire that should be operated within an ambient temperature range of -20 o C to 40 o C. Ensure power is off before installation. Installation must be carried out by qualified electricians. To clean the light fixture, switch power off and use a dry cloth without corrosive cleaning agents. 1

Daisy-Chaining & Current Ratings The current to each light fixture at the operating conditions of 58 watts/fixture and 120V, 240V & 277V is shown in the table below. Also shown is the maximum number of fixtures that can be linked together at each voltage. 16AWG wire is recommended. Parameter 120 Volts 240 Volts 277 Volts Nominal current / fixture 0.48A 0.24A 0.21A Max # of fixtures linked together in a daisy-chain 12 fixtures 30 fixtures 36 fixtures Mounting & Connection Guidelines The Infinity LED light can be flush mounted or suspension mounted. Additionally, the light fixtures can be daisy-chained together with end-to-end connections or with cables. Accessories for each type of mounting configuration is shown below. Mounting Type Mounting Accessories Daisy-chaining end-to-end connections Daisy-chaining cable connections Flush Mount Suspension Mount Power Cable: TL-PC2 Slide & Lock Clip: TL-SLIP Power Cable: TL-PC2 Suspension Kit: TL-SKIT Interconnection Clip: TL-INCLIP Interconnection Bar: TL-INBAR Interconnection Cable: TL-INC2 2

Flush Mount Installation Prepare accessories. Install slide & lock clips using Push luminaire to secure Press slide & lock clips Clip, anchor, screw, washer. anchor, screw and washer. to clips. to locking position. Flush Mount Installation - End-to-End Daisy-Chain Prepare accessories. Install slide & lock clips Push luminaires into Prepare interconnection Clip, anchor, screw, washers. with anchors. clips and connect at ends. clip at connection joint. Step 5 Press Interconnection clip into position. 3

Suspension Mount Installation Prepare accessories. Loosen screws on rope. Adjust length of rope. Tie rope to support Steel rope, slider. and tighten screws. Step 5 Put slider in channel of fixture and tighten nuts. Suspension Mount Installation - End-to-End Daisy-Chain Prepare accessories. Suspend luminaires as Slide interconnection Connect luminaires Interconnection bar. described previously. bar in fixture channel. end-to-end. Step 5 Tighten screws to secure bar in position. Completed Installation Two luminaires suspended and daisy-chained. 4

Electrical connections It is important to ensure all electrical connections are robust and secure since a loose connection can result in an electrical malfunction. Power Cable Secure the power cable to the light fixture power connector by pressing the cable connector firmly into the mating connector on the fixture. A screw is provided with the power cable to safeguard against the cable loosening over time. Once the power cable is connected to the fixture, tighten the screw see picture below. Screw for power cable End-to-end daisy-chain connections Be sure to use the interconnection clip for flush mount installations and the interconnection bar for suspension installations to create a secure electrical connection when daisy-chaining fixtures together in an end-to-end fashion. Below is a view of the interconnection bar connecting two Infinity lights together. Interconnection bar 5