Medium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

Similar documents
High-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

300 kw ~ 6,300 kw (400 HP ~ 8,500 HP) MEDIUM VOLTAGE VERTICAL MOTORS

Low and Medium Voltage Motors. 21-FII Series. New High Efficiency Design 37 kw 1,400 kw (50 HP 1,850 HP)

High Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP)

Design specifications

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Three-phase Induction Motors Global Series Empowering the Future

Cutting-edge technologies backed by a century of experience

GE Power Conversion. N3 Series Model N37 MV Induction Motor 4 Pole, 50Hz

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

Compact, flexible, highest availability.

GE Motors. PegasusTMMHV. Medium Voltage AC Induction Motors. NEMA Frames ,000 HP IEC Frames ,000 kw

Pricing Guide for Horizontal Above NEMA Motors ANSP , Rev.0 above NEMA

Permanent Magnet Motors for Cooling Tower Applications PAUL HUMBERT TOWER ENGINEERING, INC

MJH. Model. Up to kva. Power. Up to V. Voltages. Frame 400 ± Pole 4, 6, 8. (over contact MM) Cooling IC 01

W22 Medium Voltage Motors TEFC - Severe Duty

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

Medium Voltage Motors

+7 /342/ Двигатели с фазным ротором (серии AML, AMK; 4-12 полюсов, до 8000 кв, HP) Телефон (многоканальный):

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

Innovation fuels our passion for reliable performance

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Industrial Machinery PU LARGE MOTORS

Compact, flexible, highest availability. H-compact PLUS

NEMA & IEC Product Features and Benefits

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

MJB. Model. Up to kva. Power. Up to V. Voltages. Frame 160 ± 900. Pole 4, 6, 8, 10 and 12. (over contact MM) Cooling IC 01

Pricing Guide for Horizontal AboveNEMA Motors Rev. 2

Slip-ring motors MAR Series

Modifiable TITAN Horizontal Motors Accessories and Modifications

HIGH VOLTAGE MOTOR SQUIRREL CAGE INDUCTION

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

Induction and ,000 HP 75-15,000 kw Pegasus MHV Quantum LMV Custom Synchronous Motors. GE Energy

Electric Machines Catalogue. Quality MV and HV Machines from Stock & Engineered to Order PRODUCT CATALOGUE

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

Weather Protected Type II (WPII) Totally Enclosed Fan-Cooled (TEFC) Totally Enclosed Air to Air Cooled (TEAAC)

From 4 to 20 poles ( over contact MM) IP 23. Available up to IP 44 with filters.

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

WORLD SERIES I N D U C T I O N M O T O R S & G E N E R A T O R S

SECTION MOTOR REQUIREMENTS for HVAC

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

Hazardous Area Motors Protecting production and life. Empowering the Future

YKK High-voltage Three-phase Asynchronous Motor

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

High voltage flameproof induction motors The simplest solution for hazardous environments

Hazardous Area Motors Protecting production and life. Empowering the Future

DOCUMENTATION PACKAGE

DRIP-PROOF SPLASH-PROOF WOUND ROTOR HORIZONTAL AND VERTICAL INDUCTION MOTORS. Custom designed. 100% U.S. manufactured

DOCUMENTATION PACKAGE

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

Power Generation for the 21st Century

Quantum LMV. Low and Medium Voltage AC Induction Totally Enclosed Fan Cooled Motors. GE Power Conversion

A Full Line of Low Voltage IEC Motors In-Stock

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

General purpose aluminum motors Technical data for totally enclosed squirrel cage three phase motors, two-speed

7.0 High HP Low and Medium Voltage

SQUIRREL CAGE THREE PHASE INDUCTION MOTORS INDUCTION MOTORS

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

4-Pole Turbine Generator 4-Pole Air-Cooled Turbine Generator

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE VOLT CONNECTION(S). IF OTHER VOLTAGE CONNECTIONS ARE AVAILABLE, THE AMPERES WILL

IECEx Certificate of Conformity Annexe

DRY TYPE TRANSFORMERS

AC Induction Motors. Installation and operating instructions

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

Suitability of Direct Drive Motor Technology as applied to ACC s. Bill Martin & Tom Weinandy

BRUSHLESS EXCITERS FOR TURBINE GENERATORS

INDUCTION MOTOR. There is no physical electrical connection to the secondary winding, its current is induced

ANNEX No 1. C 17/05/2006 SGA112B TERMINAL BOX ARRANGEMENT Ex e, Ex na &Ex td V (OPTION 2)

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SERIES COOLING TOWER. MULTI-CELL HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE

2-Pole Turbine Generator

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

Motor Basics AGSM 325 Motors vs Engines

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

INTER PLANT STANDARD STEEL INDUSTRY. Corresponding IS does not exist

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Features and Benefits

XQ-5200 Solar T60 Gas Turbine-Generator 5,200 ekw Iso Conditions 13.8 kv

MAX-E1 HIGH EFFICIENCY. Severe Duty

QUARTER-TURN ELECTRIC ACTUATORS

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Marine generators Proven generators for reliable power on board

SUPER-MAX INDUCTION MOTOR

Catalog. Low voltage General performance IE2 high efficiency motors according to EU MEPS

INDEX NEMA PREMIUM EFFICIENCY

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Alternating Current Motors in Detail

Duty Master Above NEMA Frame AC Induction Motors

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Transcription:

Medium Voltage Induction Motors 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

series: Combining over 100 years of experience with innovative new technology makes the series the right choice for the demanding needs of today's industry. Superior Electrical Performance, Unsurpassed Reliability The 21-L series three-phase high-voltage motors are at the leading edge of motor technology. Designs up to 18,500 kw (25,000 hp) From 2 pole up to 24 pole designs 2,300 13,800 Volts, 50 or 60 Hz Wide variety of enclosures Rugged, high quality fabricated steel construction Frame sizes from 450 mm ~ 900 mm shaft height Designed to be able to meet worldwide standards (NEMA, IEC, BS, AS and others) Features/Benefits: Excellent Electrical Performance Higher efficiency than any previous design High power factor Superior starting characteristics Enclosure Options ODP, WP1, WP2/IP24 TEAAC, TEWAC, TESV/PIPE/IP55 New Compact Design derived Through Extensive electrical magnetic field analysis Heat transfer analysis Improved ventilation Lower Noise & Less Vibration Advanced techniques in core/frame construction Advanced VPI Insulation System Compatible with VFD voltage supplies and effects of surge voltages Excellent In-Service Availability Low operating and maintenance costs High reliability Oil-lubricated sleeve bearings or anti-friction bearings Extended re-greasing intervals Designs for all Applications and Industries Compatible with Variable Frequency Drive Applications Fabricated Copper Bar Rotor Construction 2

Series Motor Enclosures Output: 50 Hz 450 ~ 16,500 kw (600 ~ 22,000 HP) 60 Hz 450 ~ 18,500 KW (600 ~ 25,000 HP) Voltages: 2,300 V ~ 13,800 V Insulation Class: F Class, with B design temperature rise Standards: IEC, NEMA, BS, AS and others available Totally-Enclosed Air-Water- Cooled Type TEWAC/IP55 This type of motor is especially useful in a location where low noise operation is required or where it is desired to remove heat from the area where the motor is located. The motor includes an air-to-water heat exchanger in the air housing above the motor. A drain in the air housing protects the motor from damage should any water leakage ever occur. Totally-Enclosed Air-Air Cooled Type TEAAC/IP55 In an environment containing corrosive or harmful gas, a totally- enclosed fancooled motor can be applied. An external fan mounted on the opposite drive end shaft directs fresh air through the pipes in the air housing above the motor. The pipes serve as a heat exchanger in which outside fresh air passing through cools the hot air inside. NEMA Weather-Protected WPII/IP24 This motor is designed for outdoor operation. In accordance with NEMA WPII, the housing air path includes right-angled turns, dropping air intake air velocity below 3 m/sec (600 ft/min.). This traps water, dust, and foreign materials. A section is provided that allows air to pass through without being forced into the motor. Open Drip Proof Type ODP/IP22 A drip-proof type motor is a common choice for a protected, well-ventilated room. Cooling air intake and hot air exhaust windows are located at the top of the hood. Openings are covered by screens and enclosure is constructed to prevent intrusion of water drips and other foreign materials into the motor meeting NEMA WP-I requirements. Common Foundation Base IC01, IC61 and IC81W cooling per IEC Standard construction are available by changing the top-mounted air housing. The main terminal box can be rotated through 90 angles, and is large enough for easy cable connection. A shaft current protection insulator in the non-drive end bearing on 450 frame and larger, and all sleeve bearing machines, is included as standard. 3

Features of Reliability & Easy Operation/Maintenance Series Motors Main Terminal Box NEMA Type II terminal box is standard. Boxes including surge protection and/or differential CT's are readily available. Standard main terminal box can be rotated every 90. Adequate space is allowed below main terminal box for cable connection. Stator Core Stators use high grade electrical steel with low magnetic losses. Stator assembly is easily removed from the stator frame if ever necessary. Frame Increased rigidity of stator frame and lower vibration are achieved through frequency analysis. Auxiliary Terminal Box Modular arrangement for accessory connections allows flexibility with standardized mechanical construction. 4

Air Housing NEMA Open Drip Proof (IP22) construction provides protection from dripping liquids and foreign materials. NEMA WPII (IP24) top hood construction prevents instrusion of rain water and foreign matter. IP55 protection is standard on TEAAC (aircooled) and TEWAC (water-cooled) motors, and isolates the motor interior from environmental contamination. Stator Coil Utilizes a highly reliable, vacuum pressurized impregnation (VPI) insulation system providing firmly-fixed coil ends and the ability to withstand most environments. Bracing ensures long life despite the stresses imposed by starting and duty cycles. Rotor Copper rotor bars are standard. They are shaped to provide excellent torque characteristics and mechanical strength. Bars are fixed firmly in the slots by continuous swaging of each rotor bar. Bearing Antifriction and sleeve bearings are easily maintainable. Antifriction (ball, roller) bearings use a refined lubrication design that makes regreasing simple. 5

Open Drip Proof Induction Motor DP/IP22 Forced feed lubricated sleeve bearings Four Pole, 6.6 kv, 60 Hz Example outlines for 4 pole machine specifications shown below. 2 pole to 24 pole designs available * Example, not for construction Dimensions (mm) Frame Poles C D 2E 2F H J K L M N P Z 450-1400 4 450 1830 800 1400 1505 160 265 2550 1000 1930 650 48 450-1600 4 450 1830 800 1600 1505 160 265 2750 1000 2130 650 48 500-1600 4 500 1950 900 1600 1675 180 265 2800 1120 2130 710 56 500-1800 4 500 1950 900 1800 1675 180 265 3030 1120 2330 710 56 560-1800 4 560 2115 1000 1800 1880 225 265 3120 1260 2330 805 66 560-2000 4 560 2115 1000 2000 1880 225 265 3320 1260 2530 805 66 630-2000 4 630 2275 1120 2000 2115 250 265 3320 1420 2530 885 66 630-2240 4 630 2275 1120 2240 2115 250 265 3757 1420 2770 885 66 Power (kw) Frame Weight (kg) Speed (rpm) (A) Rated Current Torque Efficiency Power Factor Safe Stall Time (SEC) 11500 630-2240 14600 1780 1143 550 60 170 97.9 97.7 97.1 90.0 89.9 89.0 10 15 6 Max. F.L. 3/4 L 1/2 L F.L. 3/4 L 1/2 L Hot Cold 1800 450-1400 4500 1775 185 500 60 190 96.6 96.4 95.6 88.3 87.5 84.0 12 15 2000 450-1400 4700 1775 205 500 60 190 96.7 96.5 95.8 88.4 87.7 84.5 12 15 2250 450-1400 4700 1775 230 500 60 190 96.8 96.6 95.9 88.5 87.9 84.8 12 15 2500 450-1400 4900 1775 255 500 60 190 96.9 96.8 96.1 88.5 88.1 85.0 12 15 2800 450-1400 5100 1775 285 550 60 190 97.1 96.9 96.3 88.6 88.2 85.1 12 15 3150 450-1600 5900 1775 320 600 60 220 97.2 97.1 96.5 88.8 88.3 85.6 12 15 3550 450-1600 5900 1775 360 600 60 200 97.3 97.2 96.6 88.9 88.3 86.2 12 15 4000 500-1800 6800 1775 405 500 60 160 97.3 97.2 96.7 89.9 88.7 86.9 12 15 4500 500-1800 7300 1775 452 500 60 170 97.5 97.3 96.7 89.4 88.9 87.5 12 15 5000 500-1800 7700 1780 502 500 60 170 97.6 97.4 96.8 89.4 89.0 87.7 12 15 5600 500-1800 8000 1780 560 500 60 170 97.7 97.5 96.8 89.6 89.0 87.8 12 15 6000 500-1800 8200 1780 299 500 60 170 97.6 97.5 96.9 89.8 89.3 87.9 12 15 6300 560-1800 9500 1780 629 500 60 180 97.7 97.5 96.8 89.8 89.4 88.2 10 15 6500 560-1800 9500 1780 648 450 60 170 97.7 97.5 96.9 89.9 89.4 88.4 10 15 7100 560-2000 9800 1780 708 450 60 170 97.7 97.5 96.9 89.9 89.4 88.5 10 15 7500 560-2000 10300 1780 747 450 60 170 97.7 97.5 96.9 89.9 89.4 88.5 10 15 8000 560-2000 10700 1780 797 500 60 180 97.8 97.6 96.9 89.8 89.4 88.6 10 15 8500 560-2000 11000 1780 847 500 60 180 97.7 97.6 96.9 89.8 89.5 88.6 10 15 9000 630-2000 12400 1780 897 500 60 170 97.7 97.6 96.9 89.8 89.4 88.6 10 15 9500 630-2000 12400 1780 948 500 60 170 97.7 97.6 97.0 89.8 89.5 88.7 10 15 10000 630-2000 12800 1780 997 500 60 170 97.8 97.6 97.1 89.8 89.6 88.6 10 15 10500 630-2000 12800 1780 1046 500 60 170 97.8 97.7 97.1 89.8 89.7 88.8 10 15 11000 630-2240 14600 1780 1094 550 60 170 97.9 97.7 97.1 89.9 89.8 88.9 10 15

Outdoor Induction Motor WPII/IP24 Forced feed lubricated sleeve bearings Four Pole, 6.6 kv, 60 Hz Example outlines for 4 pole machine specifications shown below. 2 pole to 24 pole designs available * Example, not for construction Dimensions (mm) Frame Poles C D 2E 2F H J K L M N P Z 450-1400 4 450 1830 800 1400 2135 160 265 2550 1000 1930 650 48 450-1600 4 450 1830 800 1600 2135 160 265 2750 1000 2130 650 48 500-1600 4 500 1950 900 1600 2375 180 265 2800 1120 2130 710 56 500-1800 4 500 1950 900 1800 2375 180 265 3030 1120 2330 710 56 560-1800 4 560 2115 1000 1800 2665 225 265 3120 1260 2330 805 66 560-2000 4 560 2115 1000 2000 2665 225 265 3320 1260 2530 805 66 630-2000 4 630 2275 1120 2000 2995 250 265 3320 1420 2530 885 66 630-2240 4 630 2275 1120 2240 2995 250 265 3757 1420 2770 885 66 Power (kw) Frame Weight (kg) Speed (rpm) (A) Rated Current Torque Efficiency Power Factor Safe Stall Time (SEC) 11500 630-2240 15100 1780 1143 550 60 170 97.9 97.7 97.1 90.0 89.9 89.0 10 15 7 Max. F.L. 3/4 L 1/2 L F.L. 3/4 L 1/2 L Hot Cold 1800 450-1400 4800 1775 185 500 60 190 96.6 96.4 95.6 88.3 87.5 84.0 12 15 2000 450-1400 5000 1775 205 500 60 190 96.7 96.5 95.8 88.4 87.7 84.5 12 15 2250 450-1400 5000 1775 230 500 60 190 96.8 96.6 95.9 88.5 87.9 84.8 12 15 2500 450-1400 5200 1775 255 500 60 190 96.9 96.8 96.1 88.5 88.1 85.0 12 15 2800 450-1400 5400 1775 285 550 60 190 97.1 96.9 96.3 88.6 88.2 85.1 12 15 3150 450-1600 6200 1775 320 600 60 220 97.2 97.1 96.5 88.8 88.3 85.6 12 15 3550 450-1600 6200 1775 360 600 60 200 97.3 97.2 96.6 88.9 88.3 86.2 12 15 4000 500-1800 7100 1775 405 500 60 160 97.3 97.2 96.7 89.9 88.7 86.9 12 15 4500 500-1800 7600 1775 452 500 60 170 97.5 97.3 96.7 89.4 88.9 87.5 12 15 5000 500-1800 8100 1780 502 500 60 170 97.6 97.4 96.8 89.4 89.0 87.7 12 15 5600 500-1800 8300 1780 560 500 60 170 97.7 97.5 96.8 89.6 89.0 87.8 12 15 6000 500-1800 8600 1780 299 500 60 170 97.6 97.5 96.9 89.8 89.3 87.9 12 15 6300 560-1800 9900 1780 629 500 60 180 97.7 97.5 96.8 89.8 89.4 88.2 10 15 6500 560-1800 9900 1780 648 450 60 170 97.7 97.5 96.9 89.9 89.4 88.4 10 15 7100 560-2000 10200 1780 708 450 60 170 97.7 97.5 96.9 89.9 89.4 88.5 10 15 7500 560-2000 10800 1780 747 450 60 170 97.7 97.5 96.9 89.9 89.4 88.5 10 15 8000 560-2000 11100 1780 797 500 60 180 97.8 97.6 96.9 89.8 89.4 88.6 10 15 8500 560-2000 11400 1780 847 500 60 180 97.7 97.6 96.9 89.8 89.5 88.6 10 15 9000 630-2000 12900 1780 897 500 60 170 97.7 97.6 96.9 89.8 89.4 88.6 10 15 9500 630-2000 12900 1780 948 500 60 170 97.7 97.6 97.0 89.8 89.5 88.7 10 15 10000 630-2000 13300 1780 997 500 60 170 97.8 97.6 97.1 89.8 89.6 88.6 10 15 10500 630-2000 13300 1780 1046 500 60 170 97.8 97.7 97.1 89.8 89.7 88.8 10 15 11000 630-2240 15100 1780 1094 550 60 170 97.9 97.7 97.1 89.9 89.8 88.9 10 15

Totally Enclosed Air to Water Cooled Induction Motor TEWAC/IP54 Forced feed lubricated sleeve bearings Four Pole, 6.6 kv, 60 Hz Example outlines for 4 pole machine specifications shown below. 2 pole to 24 pole designs available * Example, not for construction Dimensions (mm) Frame Poles C D 2E 2F H J K L M N P Z 450-1400 4 450 1940 800 1400 1865 160 265 2550 1000 1930 760 48 450-1600 4 450 1940 800 1600 1865 160 265 2750 1000 2130 760 48 500-1600 4 500 2065 900 1600 2015 180 265 2800 1120 2130 825 56 500-1800 4 500 2065 900 1800 2015 180 265 3030 1120 2330 825 56 560-1800 4 560 2225 1000 1800 2130 225 265 3120 1260 2330 915 66 560-2000 4 560 2225 1000 2000 2130 225 265 3320 1260 2530 915 66 630-2000 4 630 2380 1120 2000 2330 250 265 3320 1420 2530 990 66 630-2240 4 630 2380 1120 2240 2330 250 265 3757 1420 2770 990 66 Power (kw) Frame Weight (kg) Speed (rpm) (A) Rated Current Torque Efficiency Power Factor Safe Stall Time (SEC) 11500 630-2240 15300 1780 1143 550 60 170 97.9 97.7 97.1 90.0 89.9 89.0 10 15 8 Max. F.L. 3/4 L 1/2 L F.L. 3/4 L 1/2 L Hot Cold 1800 450-1400 5000 1775 185 500 60 190 96.6 96.4 95.6 88.3 87.5 84.0 12 15 2000 450-1400 5200 1775 205 500 60 190 96.7 96.5 95.8 88.4 87.7 84.5 12 15 2250 450-1400 5200 1775 230 500 60 190 96.8 96.6 95.9 88.5 87.9 84.8 12 15 2500 450-1400 5400 1775 255 500 60 190 96.9 96.8 96.1 88.5 88.1 85.0 12 15 2800 450-1400 5600 1775 285 550 60 190 97.1 96.9 96.3 88.6 88.2 85.1 12 15 3150 450-1600 6400 1775 320 600 70 220 97.2 97.1 96.5 88.8 88.3 85.6 12 15 3550 450-1600 6400 1775 360 600 70 200 97.3 97.2 96.6 88.9 88.3 86.2 12 15 4000 500-1800 7300 1775 405 500 60 160 97.3 97.2 96.7 89.9 88.7 86.9 12 15 4500 500-1800 7800 1775 452 500 60 170 97.5 97.3 96.7 89.4 88.9 87.5 12 15 5000 500-1800 8300 1780 502 500 60 170 97.6 97.4 96.8 89.4 89.0 87.7 12 15 5600 500-1800 8500 1780 560 500 60 170 97.7 97.5 96.8 89.6 89.0 87.8 12 15 6000 500-1800 8800 1780 299 500 60 170 97.6 97.5 96.9 89.8 89.3 87.9 12 15 6300 560-1800 10200 1780 629 500 60 180 97.7 97.5 96.8 89.8 89.4 88.2 10 15 6500 560-1800 10200 1780 648 450 60 170 97.7 97.5 96.9 89.9 89.4 88.4 10 15 7100 560-2000 10500 1780 708 450 60 170 97.7 97.5 96.9 89.9 89.4 88.5 10 15 7500 560-2000 11000 1780 747 450 60 170 97.7 97.5 96.9 89.9 89.4 88.5 10 15 8000 560-2000 11400 1780 797 500 60 180 97.8 97.6 96.9 89.8 89.4 88.6 10 15 8500 560-2000 11700 1780 847 500 60 180 97.7 97.6 96.9 89.8 89.5 88.6 10 15 9000 630-2000 13200 1780 897 500 60 170 97.7 97.6 96.9 89.8 89.4 88.6 10 15 9500 630-2000 13200 1780 948 500 60 170 97.7 97.6 97.0 89.8 89.5 88.7 10 15 10000 630-2000 13600 1780 997 500 60 170 97.8 97.6 97.1 89.8 89.6 88.6 10 15 10500 630-2000 13600 1780 1046 500 60 170 97.8 97.7 97.1 89.8 89.7 88.8 10 15 11000 630-2240 15300 1780 1094 550 60 170 97.9 97.7 97.1 89.9 89.8 88.9 10 15

Totally Enclosed Air to Air Cooled Induction Motor TEAAC/IP54 Forced feed lubricated sleeve bearings Four Pole, 6.6 kv, 60 Hz Example outlines for 4 pole machine specifications shown below. 2 pole to 24 pole designs available * Example, not for construction Dimensions (mm) Frame Poles C D 2E 2F H J K L M N P Z 450-1400 4 450 1830 800 1400 1920 160 265 3015 1000 1930 650 48 450-1600 4 450 1830 800 1600 1920 160 265 3215 1000 2130 650 48 500-1600 4 500 1950 900 1600 2090 180 265 3215 1120 2130 710 56 500-1800 4 500 1950 900 1800 2090 180 265 3465 1120 2330 710 56 560-1800 4 560 2115 1000 1800 2280 225 265 3465 1260 2330 805 66 560-2000 4 560 2115 1000 2000 2280 225 265 3695 1260 2530 805 66 630-2000 4 630 2275 1120 2000 2420 250 265 3815 1420 2530 885 66 630-2240 4 630 2275 1120 2240 2420 250 265 4055 1420 2770 885 66 Power (kw) Frame Weight (kg) Speed (rpm) (A) Rated Current Torque Efficiency Power Factor Max. Safe Stall Time (SEC) F.L. 3/4 L 1/2 L F.L. 3/4 L 1/2 L Hot Cold 1400 450-1400 5000 1780 145 550 60 200 96.0 95.5 94.2 88.5 88.0 84.8 12 15 1600 450-1400 5200 1780 164 500 60 190 96.2 95.8 94.6 88.9 88.2 85.6 12 15 1800 450-1400 5400 1780 184 600 60 210 96.4 96.0 94.8 88.9 88.2 85.5 12 15 2000 450-1400 5600 1780 204 600 60 210 96.6 96.2 95.1 89.0 88.3 85.6 12 15 2250 450-1400 5800 1780 229 600 60 210 96.7 96.4 95.3 89.0 88.3 85.6 12 15 2500 450-1600 6300 1780 254 600 60 210 96.9 96.5 95.5 89.1 88.5 85.7 12 15 2800 450-1600 6700 1780 283 600 60 220 97.0 96.6 95.6 89.3 88.6 86.1 12 15 3150 500-1600 7400 1780 317 550 60 190 97.0 96.6 95.6 89.9 89.0 86.7 10 15 3550 500-1600 7900 1780 355 550 60 200 97.2 96.8 95.8 90.2 89.4 87.1 10 15 4000 500-1800 8400 1780 399 550 60 210 97.3 96.9 95.9 90.2 89.4 87.1 10 15 4500 500-1800 8900 1780 448 600 60 220 97.4 96.9 69.0 90.3 89.5 86.9 10 15 5000 560-1800 10400 1780 498 500 60 190 97.4 96.9 96.0 90.2 89.6 87.2 10 15 5600 560-2000 11600 1780 557 550 60 210 97.4 97.0 96.0 90.5 89.6 87.3 10 15 6000 630-2000 12500 1780 598 550 60 190 97.4 97.1 96.1 90.1 89.4 87.3 10 15 6300 630-2000 12500 1780 628 500 60 190 97.4 97.1 96.1 90.2 89.3 87.4 10 15 6500 630-2000 12900 1780 647 600 70 210 97.5 97.1 96.1 90.2 89.4 87.2 10 15 7100 630-2000 13300 1780 706 600 70 210 97.6 97.2 96.2 90.3 89.5 87.2 10 15 7500 630-2000 14200 1780 745 600 70 200 97.6 97.3 93.3 90.3 89.8 87.5 10 15 8000 630-2000 14500 1780 794 600 70 200 97.7 97.3 93.3 90.3 89.8 87.4 10 15 8500 630-2240 15400 1780 844 600 70 200 97.7 97.4 96.4 90.3 89.6 87.2 10 15 9

Main Terminal Box Drawing 640 800 450 205 205 STAND OFF INSULATORS 3 A DIA HOLES 510 525 470 6 Large Main Terminal Box 40 50 740 GROUNDING TERMINAL M10 SCREWS 30 60 1050 390 PF4 GRADE B P. No. 1 2 3 A Dimensions (mm) 12 15 28 Area available for accessories such as arrestors, surge capacitors, CTs, etc. Other Accessories Available RTDs Space Heaters Dial Thermometer Vibration Detector 10

Series Internal Details AIR HOOD BEARING COVER AIR DEFLECTOR COOLING HOUSING STATOR CORE STATOR WINDING AIR DEFLECTOR INTERNAL FAN COVER EXTERNAL FAN COVER BEARING HOUSING BEARING BRACKET SPACE HEATER TERMINAL BOX MAIN TERMINAL BOX RTD TERMINAL BOX STATOR FRAME ROTOR CORE AND CAGE WINDING SHAFT WITH FANS BEARING BRACKET BEARING HOUSING 11

TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION Mita 43 MT Bldg., 13-16 Mita 3 chome Minato-ku Tokyo, 108-0073 Japan Tel.: +81-3-5444-3828 www.tmeic.co.jp TMEIC Corporation 1325 Electric Road, Suite 200 Roanoke, VA, 24018 Tel.: +1-540-283-2000 info@tmeic.com www.tmeic.com TMEIC Corporation, Houston Branch 2901 Wilcrest Dr., Suite 110 Houston, TX 77042 Tel.: +1-837-767-2680 OilGas@tmeic.com www.tmeic.com 2012 TMEIC Corporation, U.S.A. All Rights Reserved Information provided in this brochure is subject to change without notice. M-1153