DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Similar documents
DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Medium Voltage Metal-Enclosed Switches

F1-1 ACCESSORIES AND SPARE PARTS FOR DRIWISA EQUIPMENTS INDOOR SERVICE OVERVIEW DRIESCHER Y WITTJOHANN, S.A.

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

vertical fuse switch disconnectors

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Fuse switch disconnectors

DBM Range 1500VDC (13,5kA to 20kA)

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

33KV INDOOR SWITCHGEAR

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

HD4. Gas insulated MV circuit-breakers kv A ka

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

I-1 DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE. Overview

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

CERTIFIED TEST REPORT

3TM Vacuum Contactors

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

SF6 Gas-Insulated Metal Enclosed Switchgear

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Gas Insulated Metal-clad Switchgear, HMGS!

Limitor -G General Purpose Fuses

Gas Insulated Switchgear

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

045 : 2000 CEB STANDARD

Medium Voltage current limiting Fuse links

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Elimsan High Voltage Disconnectors

STROM SICHER SCHALTEN

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

PIX-H Metal-clad switchgear up to 17.5kV

Extensible Unit - VCE2a

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

TECHNICAL SPECIFICATIONS

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Medium Voltage current limiting Fuse links

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

OTEC Transfer switch open transition

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

100 / 110 DRYWELL FUSE SPECIFICATION

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

B4 Load Break Switches

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

CPG.0 Single busbar gas-insulated cubicles

IEC Standard Back-Up Fuse-Links

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

HMI, APRIL, Test Laboratories in Ratingen

Prüffeld der Schaltwerke

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

MEDIUM VOLTAGE DISCONNECTOR SWITCHES for indoor installation

Technical Information

Benefits, typical uses

CP Automatic capacitor bank

High Power Switches. Expertly engineered for reliable performance. L High Power Switches

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

EMPAC Metal enclosed capacitor bank for wind applications

High-voltage high-breaking capacity VV fuse-links

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Transcription:

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS TECHNICAL SPECIFICATION LOAD BREAK DISCONNECTOR SWITCHES WITHOUT FUSE HOLDER UIT FUSE HOLDER

SECTION CONTENTS PAGE 1 General Features 3 2 Standards 3 3 Service Conditions 4 4 Electrical Capacities 4 5 Construction 5 6 Technical Information 6 7 Tests 6 8 Marking 6 9 Accessories and Spare Parts 7

1.- General Features Load break disconnector switches on air DRIWISA are used in medium voltage systems from 7.2 kv up to 38 kv, fulfilling the following applications: Sectionalize and isolate lines or cables, metal enclosed substations, bars and the power supply. Sectionalize and isolate ring networks. Connect or disconnect transformers. Load break disconnector switches on air DRIWISA have as main features: Opening and closing operation in tripolar group. Quick main and quick break mechanism, without depending the operator ability. Fuse operation (load break disconnector switches with fuse holder). Load break disconnector Switches on air DRIWISA are installed inside the metal enclosed substations or medium voltage metal enclosed switchgear for indoor or outdoor service and complies with the following requirements: 2.- Standards Easy installation. Vertical, horizontal or inverted mounting. Safe and simple operation. Minimum Maintenance. Load break disconnector Switches on air DRIWISA comply with the following Standards: NMX-J-098 NMX-J-564 NMX-J-323 NMX-J-068 NMX-J-149/1 IEC 62271-1 IEC 62271-103 IEC 62271-105 IEC 62271-200 IEC 60273 IEC 60282-1 ANSI-IEEE STD C37.20.3 ANSI C37.22 IEEE STD C37.20.4-2001 Sistemas eléctricos de potencia-suministro-tensiones eléctricas normalizadas Equipos de desconexión y su control - parte 1: especificaciones comunes Cuchillas seccionadoras de operación con carga para media tensión - especificaciones y métodos de prueba Tableros de alta tensión Fusibles alta tensión-parte 1: cortacircuitos - fusibles limitadores de corriente Common specifications Switches for rated voltages above 1 kv and less than 52 kv Alternating current switch-fuse combinations Ac metal-enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv Characteristics of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 v High-voltage fuses - Part 1: Current-limiting fuses Standard for metal-enclosed interrupter switchgear Preferred ratings and related required capabilities for indoor ac medium-voltage switches used in metal-enclosed switchgear Standard for indoor ac switches (1 kv 38 kv) for use in metal-enclosed switchgear

3.- Service Conditions Load break disconnector switches on air DRIWISA are able to operate within the range of the following environment conditions. Temperature: -10 ºC / +40 ºC. Relative Humidity: < 60% Altitude: 0-1000 msnm * *For higher installation heights must apply the appropriate correction factor. (IEC 60694) The enclosure, metal enclosure substation or board, must have the appropriate NEMA or IP degree protection to secure the specified temperature or humidity conditions and keep the inside air free of smoke, gases, water, corrosive or explosive steamers and electrically conductive particles (dust). IEC 60529 NEMA 250 Degrees of protection provided by enclosures (IP Code) Enclosures for electrical equipment (1000 volts maximum) 4.- Electrical Capacities Load break disconnector switches on air DRIWISA comply with the following electrical values (according to the requirements of Section 2 Standards): RATED MAXIMUM VOLTAGE RATED CURRENT RATED PEAK CURRENT RATED SHORT CIRCUIT CURRENT RATED WITHSTAND VOLTAGE IMPULSE (BIL) 1.2 X 50µs RATED WITHSTAND VOLTAGE 60Hz DRY 1 min. kv A ka ka (rms) @ 3 sec kv kv 400 65 25 60 20 7.2 630 65 25 60 20 1250 99 38.1 60 20 400 65 25 95 38 17.5 630 65 25 95 38 1250 99 38.1 95 38 400 65 25 125 60 25.8 630 65 25 125 60 1250 99 38.1 125 60 400 65 25 150 80 38 630 65 25 150 80 1250 99 38.1 150 80

4.1.- Rated operating capacities: Maximum switching current load In (rated current with a FP 0.7). Mechanical life: Electrical life: 1000 non-load operations 40 operation at the maximum interrupting current. 5.- Construction Load break disconnector switches on air DRIWISA are mainly constructed with the following elements: 5.1- Mounting structure A steel frame made of angles and canals with an electrolytic galvanized corrosion coating with a 18 µm thickness, able to support mechanical efforts resulting of the normal operation and the effects of short circuit currents. 5.2- Insulators Non-hydroscopic and non-flammable material with the mechanical strength to support the efforts generated of the the normal operation and the effects of short circuit currents. Its mechanical strength does not allow deformations that cause insulation failures in the non-load isolator switches. 5.3- Arc extinguíshing system It is constructed of insulating material to extinguish the maximum interrupting current and suport the electrical life established in section 4.1. 5.4- Conductive parts Are made of electrolytic cooper (99.9%) with round edges, plated with 5 µm, able to support short-term currents and stand up to the limits of temperature increase according to the standards in Section 2 Standards. 5.5.- Quick main and quick break mechanisms A solid steel bar with anticorrosive electroplated zinc coating with 18 µm thickness. La resistencia de los materiales empleados garantiza las operaciones mecánicas indicadas en el punto 4.1. 5.6- Mechanism axis (shaft) A solid steel bar with anticorrosive electroplated zinc coating with 18 µm thickness, able to support mechanical strenght efforts generated of the the normal operation and the effects of short circuit currents. 5.7.- Fuse clip holder (only in load break disconnector switch with fuse holder) Are made of electrolytic cooper (99.9%), plated with 5 µm, contact area with the fuse more than 80%. The contacts are designed to receive DRIWISA current limiting fuses (IEC 60282-1) for a 45 mm diameter contact area. 5.8.- Transmission set and tripping system for 3 poles (only in load break disconnector switch with fuse holder) Material designed for temperature rises, this ensures that can work with conductive parts or be in contact with steel parts as is indicated in NMX-J-323 standard. The designed admit DRIWISA current limiting fuses with striker pin (120 N).

5.9.- Fuse Holder (only in load break disconnector switch with fuse holder) DRIWISA fuse holder design admit the installation of DRIWISA current limiting fuses indicated i NMX-J- 149/1 and IEC 60282-1 standards and complain with the following dimensions: Striker pin is situated at the midle line of the fuse. Ø A B Ø C 2 (minimum) Ø C 1 y C 2 (maximum) 45 33 50 88 Dimensions in mm D 192 292 442 537 6.- Technical Information 6.1.- Drawings Printed drawings as required can be provided in letter size, multiple letter size or electronic format (2D and 3D). 6.2.- Instructives Easily accessed on our website http://www.driwisa.com/instructions.htm 7.- Tests 7.1.- Prototype test reports Reports of prototype tests performed in accredited national laboratories (LAPEM) that guarantee the fulfillment of the values and capacities specified in Section 4 Electrical Capacities. 7.2.- Routine Tests Routine test are done to each load break disconnector switches on air DRIWISA. Visual inspection and dimensional analysis. Contact resistance. Voltage withstand 60 Hz. 10 non-load mechanical operations

8.- Marking Load break disconnector switches on air DRIWISA contain a nameplate made of stainless steel material and has recorded the following information: Name of the manufacturer. Serial number. Type and model. Nominal voltage kv. Rated withstand voltage impulse in kv. Rated current A. Rated short circuit current in ka. Rated short circuit current time (1 s or 3 s). Legend Made in México. 9.- Accesories and spare parts. 9.1.- Accessories It offers optional accessories to be installed before or after the delivery of the non-load isolator Switches on air DRIWISA. Trip coil system. Auxiliary contacts to indicate the main blade position. Auxiliary contacts to indicate the fuses position. Auxiliary contacts to indicate the grounding switch position. Disc operator mechanism. Dual fuse kit conversion. Fuse dimension kit conversión. Motor operate with local or remote operation. Pliers for high voltage fuses with wall holders. High voltaje indicators. Conductive parts lubricant. 9.2.- Spare parts It has all components parts to provided for maintenance of the load break disconnector switches on air DRIWISA. Fuse clip holder. Complete pole Live part set. Insulators. Arc extinguís system. Quick break mechanism. Quick main mechanism.