Overhead line switchgear

Similar documents
Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Section 2 - Substation Switchgear

Disconnectors and earthing switches up to 25 kv AC

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

CPG.0 Single busbar gas-insulated cubicles

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

Air-insulated switchgear UniGear type ZS1

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

NXPLUS C Single busbar. Maintenance-free for lifetime

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

PIX-H Metal-clad switchgear up to 17.5kV

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Disconnectors and earthing switches For HV applications

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

B kv Gas-insulated Substations

FUSES. Safety through quality

SERIES TAP-CHANGER

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Disconnectors and circuit breakers For MV applications

OHB Outdoor sulphur Hexafluoride circuit-breaker

PASS M00. Multifunctional modules for high voltage substations kv; A;... 31,5 ka

Railway Infrastructure. Competent Solutions for Electric Railways and Tramways. the power connection THE PFISTERER GROUP

UniGear. Technical Guide

Substation Concepts for the Future

The 3AH Vacuum Circuit-Breakers Versatile, High-Performing, Economical

The R&S Group Reliable products for grid systems Hannover Messe companies of Rauscher & Stoecklin SERW ZREW Tesar

Gas Insulated Switchgear

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Gas Insulated Metal-clad Switchgear, HMGS!

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

COMPANY MAIN TOPIC [ PRODUCT ] TracFeed MTS. English. Disconnectors. Made in Germany

Gas-insulated switchgear up to 420 kv, 63 ka, 5000 A Type 8DQ1. siemens.com/energy. Answers for energy.

Metal Clad Air Insulated Switchgear

8DJ. Maintenance-free for lifetime

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

3AP1 DTC for 145 and 245 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Benefits, typical uses

ZX-Family Gas-insulated medium voltage switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Innovac SVS/08 - SVS/ kv modular switchgear

HD4. Gas insulated MV circuit-breakers kv A ka

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

شركة كهرباء محافظة القدس المساهمة المحدودة

Outdoor load disconnectors Fla 15/97 GB. three-pole design rated voltage 25 kv rated current 630 A

RAPIER DSB Disconnectors

TECHNICAL INFORMATION. Dipl.-Ing. (FH) Christian Niklis. Stationary Lance Earthing Device

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Certificate of Registration

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

ELECTRIC TRACTION.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Elimsan High Voltage Disconnectors

SafeGear TM Motor Control Center Arc resistant metal-clad construction

NEW CONCEPT FOR MEDIUM VOLTAGE GAS INSULATED SWITCHGEAR (GIS) by LJ Fleischer, Siemens Electricity + Control May 1999

Rapier AX Air Break Switch Disconnector. providing intelligent solutions

A 500kV AIS Switchyard Rejuvenation in British Columbia using Hybrids

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Power IT Air Insulated Cubicle Uniswitch

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Xiria 24 kv Ring Main Unit

Summary Catalogue. In 1998, the daughter company DRIBO Stará Turá s.r.o. (Ltd.) was founded in the Slovak Republic.

Product Specification

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Key elements of the AS3000 Wiring standards and some of the recent changes.

MESG 12 / 17.5 / 24 / 36 KV

Pretest Module 29 High Voltage Unit 1

B kv T&D GAS INSULATED SWITCHGEAR

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Copper Vertical Break Switch kv A.

Aluminum Vertical Break Switch kv A.

>> WI. up to 52 kv. Gas-Insulated Switchgear with Vacuum Circuit-Breaker 1, 2 or 3-phase. System configuration AREVA T&D

Metal Clad Switchgears

High-Voltage Products. Reliable products for all customer requirements. siemens.com/energy-management

High Voltage Operating Rods

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

National Certificate in Electricity Supply (Sub Station Maintainer) (Level 4)

Transcription:

Overhead line switchgear

Overhead line switchgear Typical installation General Rauscher & Stoecklin AG offers a full range of switchgear for overhead line equipment for electric traction systems at AC voltages of 15 kv and 25 kv. Thanks to our long experience in the branch, we have been awarded with accreditation by different national railways. Depending on the requirement, we can deliver complete systems or just the component you need e.g.: disconnector, load break switch, earthing switch, motor drive or manual handle, rod linkage. In addition to the conventional products, we are able to deliver two-pole switches (installed as parallel or antiparallel) as well as special designs for use in tunnels or in substations. Operating rods can even be replaced by flexible actuating systems in case of spacerestricted areas. 1 (Switch-) Disconnector 5 Rod guide 2 Direct status indication (option) 6 Motor-drive 3 Supporting structure 7 Manual handle 4 Rod linkage 8 Supporting structure

Switches Design All our disconnectors comply with the international standards in particular with IEC 60694, 62271-102 and 60265-1. To ensure a long-life service (up to 10 000 cycles), all the steel parts are either hot-dip galvanised or made of stainless steel. In addition, all conducting parts are either silver-, nickel- or tin-plated. Thanks to these features, our switches are practically maintenancefree. Our switches are available in three different designs: two rockertype models with one (design B2) or two (design B1) fixed HV-terminals. One knife-type model (design B3) with two fixed terminals completes our standard product range. Options Although the above described models cover the most customers requirements, a range of options is also available: direct status indication, silicone insulators, forced earthing, two-pole-switch kit. Function Basically, the switch family produced by Rauscher & Stoecklin AG can be divided in three sub-groups: Load break switches, isolating switches and earthing switches. > A load break switch (switch-disconnector) is able to connect or isolate sections of conductor line under load up to 2000 A. Thanks to the use of a high-vacuum disconnecting chamber, no external arc occurs during the switch-off procedure. This is particularly interesting for installations in space-restricted areas such as tunnels. > An isolating switch (disconnector, isolator) is usually actuated at a no-load state. It is able to switch small current up to 6 Amperes and is fitted with arcing horns whose function is to protect the main contact during the switching sequence. > In addition the three basic designs, a new one (design B4) has been developed to allow one disconnector to energise two different overhead lines alternatively. > An earthing switch is used to earth an already isolated section of conductor line. It is able to carry short-circuit currents. A special design (B4) had been developed to allow one disconnector to either energise or isolate or earth a section of conductor line.

The switch-off procedure of the load break switch consists of four steps > 1 The switch is closed; the line is energised. The current flows from side A to side B via the main contact. The vacuum disconnecting chamber circuit (parallel to the main contact) carries only a small part of the operating current (<1%). > 2 The two parts of the main contact are separated. At this moment the current flows entirely through the vacuum disconnecting chamber circuit. > 3 As soon as the isolating distance between the two parts of the main contact is sufficient, the vacuum disconnecting chamber opens the vacuum tube contacts. Now, no current flows through the switch. The line is no longer energised. > 4 The switch-disconnector has reached its open position; the line is now isolated.

Product overview Function Design OHL-voltage 15 kvg 25 kv Load break switch B1 FHV-B1-15 FHV-B1-25 B2 FHV-B2-15 FHV-B2-25 B3 FHV-B3-15 FHV-B3-25 Isolating switch B1 FHF-B1-15 FHF-B1-25 B2 FHF-B2-15 FHF-B2-25 B3 FHF-B3-15 FHF-B3-25 B4 FHF-B4-25 Earthing switch B3 FHE-B3-15 FHE-B3-25 B4 FHE-B4-25 Design overview B1 B2 B3 B4

Operating rods Manual handle The switch can be operated either by a manual handle or by a motor drive. The movement transmission is usually realised through a rod link-age system which is simple and cost-effective, or alternatively, for space-restricted areas, through a flexible actuating system like Flexball. Motor-drive Our motor drive MFL 200 benefits from our long experience. It is of modular design and the electrical part can easily be adapted to fulfil specific customer s requirements. For situations where the motorised design is either not possible or, for security reasons, not desired, a robust 2-position manual handle is available. It can be connected to the same operating rods as for the motorised version. In addition to that, it is possible to deliver it with a mechanical interlocking system to avoid wrong manoeuvres during the switching sequence. The outside cubicle, made of stainless steel, is designed for the worst weather conditions and is completely maintenancefree. < Manual handle Motor-drive >

Two-pole switch In case of power supply through an auto-transformer system, it could be useful to install a two-pole switch on the mast. With an additional set, two single-pole switches can be combined to give one two-pole switch using only one actuating system. As such switches are mainly motorised, the economy could be very substantial. Two-pole switch > Special installations The use of a Flexball transmission system allows optimal movement transmission between the motor drive and the switch in difficult situations as, for instance, tunnels. Special installation for tunnel >