MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

Similar documents
MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMR - 67P 67P 09/05/2016 GMR - 067P

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

MODEL GSW80 Deutz & 110 Perkins.

MODEL GSW Deutz.

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

P6000s 230V 50Hz #CONN #DPP

MODEL GBW15-22 Yanmar

THE COMPLETE PETROL PACKAGE

S V50HZ #AVR #CONN #DPP

P V 50HZ #CONN #DPP

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

The GRW Series Designed for rental businesses POWER FOR RENT

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GE.PK.022/020.SS+0_all

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Standby Amper VOLTAGE

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Standby Amper VOLTAGE

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Model NA 2 L

Model MP150 W W

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

GQW1400V. 1MWe TWINGEN in container 20 HC

GSW SERIES COMPACT ENERGY

Rating Definitions and Conditions

LWALR LIQUID COOLED LONG RUNNING GENSETS

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Rating Definitions and Conditions

Rating Definitions and Conditions

MITSUBISHI STAMFORD P CM control system. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

PGKT / / / / / / / / / / / /

Diesel generator set QSL9 series engine

Rating Definitions and Conditions

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

ENGINE brand Yanmar Yanmar Yanmar Perkins Perkins model 3TNV76 3TNV88 4TNV88 403D-15G 404D-22G Cooling system Water Water Water Water Water

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

DIESEL GENERATOR SET MTU 12V1600 DS660

POWER ENGINEERING KVA 50 HZ rpm

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PGDLS352KW 380/ / / / / / / / /

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

PGDLS / / / / / / / / /

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GE.VO.360/325.SS+0_all

Rating Definitions and Conditions

Transcription:

MSW Series 65-220 P Reliable, strong and versatile. With a large list of optional extras, these generators are suitable for many applications. High quality standards guaranteed. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

PLASTIC FUEL TANK (CANOPY VERSION) COMPLETE WITH THE FOLLOWING COMPONENT: Filler neck Air breather (ventilation pipe) Minimum fuel level sensor HEAVY DUTY ANTI- VIBRATION MOUNTS FOR DAMPING, REDUCING VIBRATION AND SHOCK PROTECTION NOISE ATTENUATION THANKS TO SOUNDPROOFING MATERIAL (ROCK WOOL) CANOPY VERSION PROVIDED WITH SINGLE DETACHABLE LIFTING EYE PLACED ON THE ROOF INTEGRATED METAL FUEL TANK (OPEN VERSION) BASEFRAME PROVIDED WITH FEET FOR EASY HANDLING EXHAUST SILENCER WITH RAIN FLAP NICHE FOR EXTERNAL EMERGENCY PUSH-BUTTON

GENERATING SET MSW65P MSW80P MSW110P MAIN DATA POWER RATING kva kwe kva kwe kva kwe STAND BY POWER - LTP 66,9 53,5 83,0 66,4 115 92 PRIME POWER - PRP 60,7 48,6 78,0 62,4 104 83 VOLTAGE (VOLT) 400/230V 400/230V 400/230V FREQUENCY 50Hz 50Hz 50Hz DIESEL ENGINE BRAND Perkins Perkins Perkins MODEL 1103A-33TG2 1104A-44TG2 1104C-44TAG2 NUMBER OF CYLINDERS / DISPLACEMENT (cc) 3 in line / 3300 4 in line / 4400 4 in line / 4410 ASPIRATION Turbocharged Turbocharged Turbocharged COOLING SYSTEM Water Water Water STARTING SYSTEM / ELECTRIC CIRCUIT (Volt) Electric / 12V Electric / 12V Electric / 12V SPEED (rpm) 1500 1500 1500 SPEED GOVERNOR (Type) Mechanical Mechanical Electronic STAND-BY POWER [LTP] (kwm) 59,3 79,2 99,5 PRIME POWER [PRP] kwm 55 73,4 90,1 FUEL CONSUMPTION @ 75% PRP (l/h) 10,4 13,4 18,0 ALTERNATOR TYPE Brushless Brushless Brushless POLES 4 4 4 VOLTAGE REGULATION SYSTEM Digital Digital Digital GENSET VERSION OPEN CANOPY OPEN CANOPY OPEN CANOPY FUEL TANK MATERIAL Metal Plastic Metal Plastic Metal Plastic CAPACITY (L) 240 209 240 209 240 209 AUTONOMY @ 75% PRP (h) 23,0 20,1 18,0 15,6 13,3 11,6 NOISE LEVEL NOISE POWER [LWA] - db(a) - 96-96 - 96 NOISE PRESSURE @ 7 m - db(a) - 67-67 - 67 OVERALL DIMENSIONS LENGTH (mm) 2200 2285 2200 2285 2200 2400 WIDTH (mm) 1000 920 1000 920 1000 1000 HEIGHT (mm) 1743 1465 1743 1465 1743 1530 DRY WEIGHT (Kg) 909 1085 964 1144 1170 1400

GENERATING SET MSW150P MSW165P MSW200P MSW220P MAIN DATA POWER RATING kva kwe kva kwe kva kwe kva kwe STAND BY POWER - LTP 148 118 164 131 203 162 216 173 PRIME POWER - PRP 138 110 153 122 183 146 196 157 VOLTAGE (VOLT) 400/230V 400/230V 400/230V 400/230V FREQUENCY 50Hz 50Hz 50Hz 50Hz DIESEL ENGINE BRAND Perkins Perkins Perkins Perkins MODEL 1106A-70TG1 1106A-70TAG2 1106A-70TAG3 1106A-70TAG4 NUMBER OF CYLINDERS / DISPLACEMENT (cc) 6 in line / 7000 6 in line / 7000 6 in line / 7000 6 in line / 7000 ASPIRATION Turbocharged Turbocharged Turbocharged Turbocharged COOLING SYSTEM Water Water Water Water STARTING SYSTEM / ELECTRIC CIRCUIT (Volt) Electric / 12V Electric / 12V Electric / 12 V Electric / 12 V SPEED (rpm) 1500 1500 1500 1500 SPEED GOVERNOR (Type) Mechanical Mechanical Mechanical Electronic STAND-BY POWER [LTP] (kwm) 136,9 203,3 180,2 191,3 PRIME POWER [PRP] kwm 123,7 199,7 162,7 173,9 FUEL CONSUMPTION @ 75% PRP (l/h) 22,72 24,47 30,9 33,6 ALTERNATOR TYPE Brushless Brushless Brushless Brushless POLES 4 4 4 4 VOLTAGE REGULATION SYSTEM Digital Digital Electronic Electronic GENSET VERSION OPEN CANOPY OPEN CANOPY OPEN CANOPY OPEN CANOPY FUEL TANK MATERIAL Metal Plastic Metal Plastic Metal Plastic Metal Plastic CAPACITY (L) 240 350 240 350 240 350 240 350 AUTONOMY @ 75% PRP (h) 10,6 15,4 9,8 14,3 7,8 11,3 7,1 10,4 NOISE LEVEL NOISE POWER [LWA] - db(a) - 97-97 - 97-97 NOISE PRESSURE @ 7 m - db(a) - 68-68 - 68-68 OVERALL DIMENSIONS LENGTH (mm) 2600 3000 2600 3000 2600 3400 2600 3400 WIDTH (mm) 1000 1150 1000 1150 1000 1250 1000 1250 HEIGHT (mm) 1743 1760 1743 1760 1743 1770 1743 1770 DRY WEIGHT (Kg) 1417 2080 1451 2038 1980 2088 2030 2138

MCP - Manual control panel Mounted on the generator and complete with analogue instrumentation, control, module for engine protection, secured with lockable door. INSTRUMENTATION (ANALOGUE) Voltmeter (1 phase) Ammeter (1 phase) Hour meter COMMANDS Start/stop selector switch with key Emergency stop button PROTECTION WITH ALARM Low fuel level Battery charger failure Low oil pressure High engine temperature Earth Fault PROTECTION WITH SHUTDOWN Low fuel level Battery charger failure Low oil pressure High engine temperature. Circuit breaker protection: III poles Emergency stop button OTHER PROTECTION Panel secured with lockable door POWER OUTPUT Power cables connection to circuit breaker ACP - Automatic control panel Automatic control panel mounted on the generator, complete with digital control unit AMF26P for monitoring, control and protection of the generator. DIGITAL INSTRUMENTATION (AMF-26P) Mains voltage Generator voltage (3 phases) Generator frequency Generator current (3 phases) Battery voltage Hour meter COMMANDS AND OTHER Four operation modes: OFF - Manual - Automatic - Automatic test Push-button for forcing Mains contactor or Generator contactor Push-buttons: start/stop, fault reset, up/down/page/enter selection Emergency stop button Remote starting availability DC system disconnection switch Automatic battery charger Password security option PROTECTION Engine protection: low oil pressure, high engine temperature Generator protection: under/over voltage, overload, under/over battery voltage Circuit breaker protection: III poles Differential protection OUTPUT PANEL ACP Plinth row for connection from ACP to LTS panel

MPP - Modular Parallel Panel Mounted on the generator, complete with digital control unit IG-NTC for monitoring, control, protection and load sharing for both single and multiple generators operating in standby or parallel modes (up to 32 generators in island). DIGITAL INSTRUMENTATION (through IG-NTC control unit) Mains: voltage, Intensity, Frequency Mains kw - kvar -Power factor Cos φ Generator voltage (3 phases) Generator frequency Generator current (3 phases) Generator Power (kva - kw - kvar) Generator Power factor Cos φ Generator kwh and kvah Battery voltage Hour meter Engine speed r.p.m. Fuel level (%) Engine temperature (depending on model) Oil pressure (depending on model) COMMAND AND OTHER Graphical display 128x64 pixels Operation modes: OFF - AMF function - Single Parallel to mains Island application - Single Parallel to Mains AMF application - Multiple parallel generator Island application Push-button for forcing Mains Breaker/contactor or Generator Breaker/ contactor Push-buttons: start/stop, fault reset, up/down/page/enter selection Multiple parallel and Power Management operation with digital load AVR sharing Automatic synchronizing and power control (via speed goveroner or ECU) Base load Import/Export and Peak shaving Voltage and PF control (AVR) Configurable digital I/O (12/12) and analogue inputs (3) Integrate PLC programmable functions Event-based history (up to 500records) Selectable measurement range 120/277V and 0-1/0-5A Remote starting and Blocking signal availability DC system disconnection switch Acoustic alarm Automatic battery charger 2xRS232/RS485/USB Communication ports Password security option PROTECTION WITH ALARM AND SHUTDOWN Engine protection: low fuel level, low oil pressure, high engine temperature Generator protection: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Others: overcurrent, short-circuit, reverse power, earth fault OTHER PROTECTION Circuit breaker protection: IV poles Motorized Emergency stop button Panel secured with lockable door OUTPUT PANEL MPP Multi-pin connectors (in and out ) for parallel with other generators Connecting cable with 2 connectors multipin (length 10m) ETB External terminal board

KPR - PREMIUM KIT To upgrade the generator equipment with a leak proof tray, leak detection sensor and manual lube oil drain pump EFT - EXTENDED FUEL TANK Larger metal fuel tank integrated in a bigger base frame allowing longer generator autonomy, at least till 48h at 75% PRP. Provided with pull bars and drainage facility AFP - AUTOMATIC FUEL PUMP Automatic fuel transfer system from an external storage fuel tank to the one integrated in the generator LTS - LOAD TRANSFER SWITCH To allow load transferring operations from Mains to generator and vice-versa. Up to 140A equipped with contactors and from 160A equipped with motorized changeover switch RCG - REMOTE CONTROL Large list of additional modules/devices for remote operation and control of the generator

www.masonsgenerators.com The producer reserves the right to introduce changes to models and features without prior notice. The pictures are purely indicative - Ed. 2015 EN/09_2015 MASONS DISTRIBUTOR IN YOUR AREA IS: PR MIDDLE EAST FZE 1206 JAFZA View 18, P.O. Box 262478 - Jebel Ali Free Zone - South 1, Dubai Tel.: +971 4 8865275 - Fax: +971 4 8865276