Type C Track Circuit Uninterruptable Power Supply

Similar documents
Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

A1P OPERATING MANUAL

A6Z OPERATING MANUAL

MODEL ELC-12/40-CVM-D BATTERY CHARGER

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

SUBSTATION EQUIPMENT - Page 1 of 8

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

MaxPak Plus Analog DC V S Drive

Installation and Operations Manual

A3Z OPERATING MANUAL

12VDC TO 230VAC INVERTERS

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

SDC,Inc. SCR-Regenerative Ac Drive

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

SECTION DC POWER SUPPLY/BATTERY CHARGER

O W N E R ' S M A N U A L

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DART Charger Product Description, Information and Specification

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

PS24/AC Volt AC 16 Amp

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

MASTR II/III 12/24V Power Supply 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz 19A149979P3 220VOLT/60 Hz

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

ATD WATT INVERTER

A Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd

TPM/GMT Panel Installation Guide

General safety and installation information.

XP800i POWER INVERTER OWNER S MANUAL

XENON POWER SUPPLY 4000 Watt Gladiator IV

POWER AMPLIFIER SERVICE MANUAL CONTENTS

5001TCP SPEED CONTROLLER

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

DP140e. Installation & Operations Manual

Uninterruptible Power Systems

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

55 Series - Miniature General Purpose Relays 5-10 A

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

AT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

TECH XP250 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

High Frequency SineWave Guardian TM

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

CONTROL FEATURES AVAILABLE OPTIONS

The Power of Reliability INSTRUCTION MANUAL

ATD WATT INVERTER

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

Battery Control Center - Diesel

5001TCP SPEED CONTROLLER


A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

DNH INDUSTRIES ***** COMPACT ***** EASY TO INSTALL ***** STATUS INDICATORS ***** DUAL LINE FUSING ***** INSULATED FRONT COVER ***** ADJUSTABLE OUTPUT

3 Uninterruptible Power Systems

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

SAFETY WARNINGS AND GUIDELINES

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

ESD5500E Series Speed Control Unit

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

Euclid Full Voltage Magnet Controller

XENON POWER SUPPLY Watt

OWNERS MANUAL JANUARY 2007 ISO

ADI-125/750 ADI-125/1500 ADI-125/2500

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Solar Hybrid Inverter SP Efecto Series

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

MODEL 8002SW (1996 MSRP $ )

********SERVICE MANUAL********* MODELS:

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Installation Sheet January, 2016 Supersedes February, 2013

Transcription:

Safetran Systems Instruction & Maintenance Model CXP-3 Type C Track Circuit Uninterruptable Power Supply

Instruction & Maintenance Type C Track Circuit Uninterruptable Power Supply Contents Introduction...2 Specifications...3 Installation...4 TroubleShooting...5 Replacement Parts...6 Schematic...7 Notes...8 I & M 010350-13 New 2/95

Model CXP-3 Type C Track Circuit Uninterruptable Power Supply The model CXP-3 Type C Track Circuit Uninterruptable Power Supply (UPS) employs a track feed transformer, power transfer relay, and standby inverter in a single housing. The CXP-3 acts as a track feed transformer when the circuit is operated with 115 VAC input power. In the event of AC power interruption, the CXP-3 converts standby battery power to an output voltage of the same RMS value as the output under normal operating conditions. The output voltage is proportional to the input voltage. The inverter runs in the standby mode. It is turned on by an internal power transfer relay in the event of the AC input power being lost. The inverter uses rugged MOSFET power transistors with the highest available current rating. The operating frequency is kept to within 1 Hz of nominal under any voltage, load, or temperature condition. Surge protection for the solid state circuitry consists of seven separate stages, including MOV's, Transorbs, Zeners, inductors and capacitors. All electronics are isolated from the chassis, giving a 3000 VAC breakdown voltage. The model CXP-3 is capable of operating up to 4 track circuits through 4 separate outputs of 6.3 VAC and 3.5 amperes each. Inputs are provided for both 115 VAC commercial power and 12 VDC standby battery power. The inverter unit is of a high efficiency design to maximize run time on the battery in the event of power failure. The model CXP-3 measures 8 inches in height, 5-1/4 inches in width, 9 inches in depth and weighs 15 pounds. It can be mounted on a standby relay rack, backboard, or shelf. 2

Specifications Electrical: Input Current: no load.25a half load 3.5A full load 6.5A Input Voltage: 12.8V Output Voltage: no load 7.3VAC half load 6.2VAC full load 5.6VAC Output Current: 3.5A Maximum Efficiency: 1/4 load 70% half load 89% Output Wave: Square Frequency: no load 60.0Hz half load 60.0Hz full load 60.0Hz Physical: Ambient Temperature: maximum 159.8 F (71 C) Dimensions: height 9 inches width 5-1/4 inches Exclusive of mounting tabs or terminals depth 9 inches 3

Installation 1. The Model CXP-3 should be rack, wall or shelf mounted within a dry, well ventilated housing. Four #10 wood screws are provided. 2. Connect the battery to the input terminals being careful to observe the proper polarity. A buzzing sound should be audible indicating that the inverter is working properly. Leads between the battery and power supply should be No.9 AWG at minimum and should be as short as practicable. 3. Measure the AC output voltage across the output terminals. The value read should be in accordance with the no load specification value. Note that the output voltage will vary proportionally with the input voltage applied. 4. Connect the load to the output terminals and again measure the AC voltage to make certain that it is satisfactory. 5. With power off, connect commercial AC power to the CXP-3 unit between terminals BX and CX as labeled on the cover. Once the power is applied, the internal power transfer relay will pick up, removing power supplied to the inverter and therefore eliminating the buzzing sound created by the inverter. 6. Again measure the AC output voltage across the output terminals to make certain that it is satisfactory. 7. Surge protection for track circuits and AC line should be provided in accordance with Railroad Standard Practice. See application drawing below for recommended surge protection. MODEL 485-28 CLEARVIEW LIGHTENING ARRESTER (#022485-28X) 1T 2T 3T MODEL 700-1 HEAVY DUTY EQUALIZER (#022700-1X) 1TR 2TR 3TR DC MODEL CXP-3 POWER SUPPLY AC 115 VAC/12 VDC INPUT MODEL SP19-2A SURGE PROTECTION NETWORK (#010806-3AX) EQUIPPED WITH A MODEL 700-1 HEAVY DUTY EQUALIZER (#022700-1X) MODEL SP20-2A SURGE PROTECTION NETWORK (#010807-6AX) EQUIPPED WITH A MODEL 701-1 AC LINE PROTECTOR (#022701-1X) 4

Trouble Shooting Trouble encountered with the CXP-3 will generally be contained within the internal solid state inverter as a result of low or no output. The following causes may be responsible and steps are outlined to isolate the cause. 1. Low output or loss of output Check the input to see that it is close to its nominal value. The output AC voltage will vary directly with the input DC voltage. If a low input voltage is responsible, this condition must be corrected. Considerable drop in voltage may occur in the leads between the battery bus and inverter under heavy load conditions. It is for this reason that heavy gauge wire and short leads are recommended on the input. 2. Excessive or short circuited load If this cause is suspected, remove the load and measure the no load voltage of this output. Check to be sure the fuses have not blown. Always replace with fuses of the same type and rating. This reading should be consistent with the no load specification values. If the no load conditions are proper, connect the load through an AC ammeter to see if the drain is excessive. A load current greater than 3.5A per output indicates a faulty or excessive load. Note that at full load the input current requirement may be as much as 10.0A. The battery must be kept well charged to insure that input voltage will be maintained with this load. With a short circuit or very high current load, either fuse can be blown. 5

Model CXP-3 Type C Track Circuit Uninterruptable Power Supply Replacement Parts To Order: Specify Description and Part Number Description Part No. Qty. Req'd Schematic Power Supply CXP-3 010350-10 1 Side Wrap CXP-3 Power Supply 010350-9 1 Top Wrap Inverter 010247-9 1 Transformer 88 VA 010247-88 1 Choke Coil #11 Wire 10" Leads 010802-7L 1 Insulating Shield 1-7/16 W/1 Slot 023408-14 2 Insulating Cap 023408-13 2 Fuse Holder 010019-9 2 Fuse 3AG 15 Amp 010350-8 1 Fuse 3AG 1.5 Amp 010350-6 1 Varistor 24 Volt 010900-51 4 Varistor 150 Volt 010900-45 1 PC Board Assembly CXP-3 w/lead 010247-10X1 1 Wire Transorb Assembly Unidirectional 010247-16X 1 Relay 120VAC P&B #PM17AY 010350-11 1 Screw Wood RD #10 x 3/4 Stl Zinc 5730-RSC 4 6

Schematic 7

Notes 8

Safetran Systems Safetran Systems Corporation 4650 Main Street N.E. Minneapolis, MN 55421 (612) 572-0466