For the National Voluntary Laboratory Accreditation Program

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Flow Research and Test Center. Creating resource technology for today and tomorrow.

Stainless Steel Precision Weights and Weight Sets

Flow Research and Test Center

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Selecting Weights and Certificates

Accredited Laboratory

OIML Weights & Weight Sets

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone:

SPECIALTY WEIGHTS CALIBRATION WEIGHTS

Certificate of Accreditation

Certificate of Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION

Certificate of Accreditation

STAINLESS STEEL NIST Class F

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis

Certificate of Accreditation

Certificate of Accreditation

Calibration of Pipe Provers in the field

Global Flow Measurement Calibration Consistency

Certificate of Accreditation

Certificate of Accreditation

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

Page 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager

Certificate of Accreditation

Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES

500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE PRESSURE

TEST EQUIPMENT USED. Part , ANSI C63.4, RSS 210

Certificate of Accreditation

Standard Calibration Certificate

Certificate of Accreditation

Laboratory Accreditation Programmes

Standard Calibration Certificate

Hellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION

SOUTH AFRICAN NATIONAL STANDARD

Healthweigh. Rice Lake Weighing Systems

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

Welcome to Garber C O R P O R AT E O V E R V I E W

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

Chapter 2. The Vehicle-Tank Metering System

Confidence in measurement.

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Comprehensive Portfolio For Consistent Performance

NAVSEA STANDARD ITEM. 2.1 Calibration Requirements List (CRL) for Shipboard Installed Instrumentation

OIML and ASTM Weights

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

DFX Series Liquid Ultrasonic Flow Meters

Model 378B02. ICP Microphone System. Installation and Operating Manual

PERFORMANCE OF THE NEW PRIMARY TORQUE STANDARD MACHINE OF INMETRO, BRAZIL

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Technical Datasheet. HM AC Series. Turbine Flow Meters. for High Pressure Applications up to 1,400 bar

Hydraulic Deadweight Tester Model CPB5800

NAVSEA STANDARD ITEM. 1.1 Title: Meter, Gage, Switch, and Thermometer; repair

System 8. Digital Torque Tester. Our most accurate digital torque tester with Fail Safe Engineering! Page 48 Sturtevant Richmont

ANALYTICAL STUDY ON THE UNCERTAINTY OF LOAD CELLS CALIBRATED WITH DEADWEIGHT-FORCE-STANDARD MACHINE AND FORCE-COMPARATOR MACHINE

Model 070A80. Front Panel Display. Installation and Operating Manual

UK Weighing Federation Technical Articles

PRELIMINARY FOR REVIEW ONLY

CERTIFICATE OF ACCREDITATION

Pressure balance Differential pressure version Model CPB5600DP

Traceability overview

Newton s 2 nd Law Activity

Model 393B31. Seismic, high sensitivity, ceramic flexural ICP accel., 10 V/g, 0.1 to 200 Hz, Installation and Operating Manual

Table of Contents. Weight Summary. Individual Weight Cases. Weight Set Cases. Custom Weight Cases. Custom Weight Carts. Weight Accessories

NC General Statutes - Chapter 81A Article 1 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Model Type T Hydraulic Deadweight Tester

Model Type T Hydraulic Deadweight Tester

Page 2 of 23 UNT150420C11

ISO-9001:2008 CYLINDERS CATALOG. Phone: Fax: Web:

Type T Hydraulic Deadweight Tester

ASTM E74-13a Explained

Calibration, Fluid Property Effects Reproducibility and Long Term Stability. All in 20 minutes! Dr Gregor Brown Cameron

Multi-Parameter Certified Reference Material

Design Aids For Structural Welded Wire Reinforcement (Metric Units for WWR/Rebar Comparison Tables)

Small hydrocarbon flow calibration facilities at NMIJ

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

Rototherm Certificates of Calibration Traceability and Quality System

PRODUCT REQUIREMENTS

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Florida Department of Agriculture Metrology Laboratory 3125 Conner Blvd. Lab #2 Tallahassee, FL 32399-1650 Ms. Amy Smith Phone: 850-921-1570 Fax: 850-921-1593 E-mail: amy.smith@freshfromflorida.com URL: http://www.freshfromflorida.com Fields of Calibration Mechanical This laboratory is compliant to ANSI/NCSL Z540-1- 1994; Part 1. (NVLAP Code: 20/A01) MECHANICAL MASS DETERMINATION (20/M08) Metric 30 kg 20 mg Echelon II 25 kg 20 mg 20 kg 12 mg 10 kg 3.0 mg 5 kg 1.6 mg 3 kg 1.7 mg 2 kg 0.82 mg 1 kg 0.18 mg 500 g 0.10 mg 300 g 59 µg 200 g 44 µg 100 g 30 µg 50 g 12 µg 30 g 8.4 µg 20 g 12 µg 10 g 5.2 µg 5 g 2.9 µg 3 g 1.7 µg 2 g 2.7 µg 1 g 2.2 µg 500 mg 2.7 µg 300 mg 8.2 µg Page 1 of 6 NVLAP-02S (REV. 2011-08-16)

200 mg 1.1 µg 100 mg 1.1 µg 50 mg 1.3 µg 30 mg 1.9 µg 20 mg 1.0 µg 10 mg 1.1 µg 5 mg 1.1 µg 3 mg 1.1 µg 2 mg 1.2 µg 1 mg 4.1 µg Avoirdupois 50 lb 13 mg Echelon II 30 lb 3.7 mg 25 lb 3.2 mg 20 lb 3.2 mg 10 lb 1.6 mg 5 lb 86 µg 3 lb 77 µg 2 lb 0.21 mg 1 lb 0.12 mg 0.5 lb 52 µg 0.3 lb 40 µg 0.2 lb 34 µg 0.1 lb 16 µg 0.05 lb 12 µg 0.03 lb 7.2 µg 0.02 lb 6.4 µg 0.01 lb 3.8 µg 0.005 lb 2.7 µg 0.002 lb 1.9 µg 0.001 lb 1.9 µg 10 oz 64 µg 8 oz 52 µg 5 oz 42 µg 4 oz 35 µg Page 2 of 6 NVLAP-02S (REV. 2011-08-16)

3 oz 28 µg 2 oz 16 µg 1 oz 10 µg 1/2 oz 7.8 µg 1/4 oz 4.3 µg 1/8 oz 3.3 µg 1/16 oz 2.1 µg 1/32 oz 1.9 µg Metric 500 kg 11 g Echelon III 250 kg 4.3 g 30 kg 0.36 g 25 kg 0.30 g 20 kg 0.24 g 10 kg 0.24 g 5 kg 0.12 g 3 kg 36 mg 2 kg 24 mg 1 kg 12 mg 500 g 8.3 mg 300 g 7.1 mg 200 g 4.7 mg 100 g 2.4 mg 50 g 1.2 mg 30 g 0.72 mg 20 g 0.49 mg 10 g 0.27 mg 5 g 0.18 mg 3 g 0.16 mg 2 g 0.13 mg 1 g 0.11 mg 500 mg 88 µg 300 mg 74 µg 200 mg 67 µg 100 mg 55 µg 50 mg 47 µg Page 3 of 6 NVLAP-02S (REV. 2011-08-16)

30 mg 42 µg 20 mg 38 µg 10 mg 33 µg 5 mg 30 µg 3 mg 27 µg 2 mg 26 µg 1 mg 25 µg Avoirdupois 1000 lb 7.4 g Echelon III 500 lb 4.7 g 50 lb 0.28 g 30 lb 0.17 g 25 lb 0.14 g 20 lb 0.11 g 10 lb 53 mg 5 lb 27 mg 3 lb 17 mg 2 lb 11 mg 1 lb 8.3 mg 0.5 lb 5.6 mg 0.3 lb 3.4 mg 0.2 lb 2.1 mg 0.1 lb 1.1 mg 0.05 lb 0.53 mg 0.03 lb 0.32 mg 0.02 lb 0.21 mg 0.01 lb 0.18 mg 0.005 lb 0.14 mg 0.003 lb 0.12 mg 0.002 lb 0.11 mg 0.001 lb 86 µg 10 oz 7.1 mg 8 oz 5.6 mg 4 oz 2.9 mg 3 oz 2.0 mg Page 4 of 6 NVLAP-02S (REV. 2011-08-16)

2 oz 1.3 mg 1 oz 0.64 mg 1/2 oz 0.33 mg 1/4 oz 0.20 mg 1/8 oz 0.16 mg 1/16 oz 0.13 mg 1/32 oz 0.11 mg Weight Carts 5000 lb 91 g NIST HB 105-8 4000 lb 77 g 3000 lb 63 g VOLUME AND DENSITY (20/M12) Volume 1500 gal 36 in 3 Volume Transfer Method 1000 gal 25 in 3 750 gal 19 in 3 525 gal 15 in 3 500 gal 15 in 3 200 gal 5.4 in 3 100 gal 2.8 in 3 60 gal 2.1 in 3 50 gal 1.9 in 3 10 gal 0.44 in 3 5 gal 0.47 in 3 4 in neck 5 gal 0.28 in 3 3 in neck 5 gal 0.30 in 3 J Liquefied Petroleum Gas Prover (LPG) 100 gal 3.4 in 3 Volume Transfer Method 25 gal 1.2 in 3 END Page 5 of 6 NVLAP-02S (REV. 2011-08-16)

Notes Note 1: A Calibration and Measurement Capability (CMC) is a description of the best result of a calibration or measurement (result with the smallest uncertainty of measurement) that is available to the laboratory s customers under normal conditions, when performing more or less routine calibrations of nearly ideal measurement standards or instruments. The CMC is described in the laboratory s scope of accreditation by: the measurement parameter/device being calibrated, the measurement range, the uncertainty associated with that range (see note 3), and remarks on additional parameters, if applicable. Note 2: Calibration and Measurement Capabilities are traceable to the national measurement standards of the U.S. or to the national measurement standards of other countries and are thus traceable to the internationally accepted representation of the appropriate SI (Système International) unit. Note 3: The uncertainty associated with a measurement in a CMC is an expanded uncertainty with a level of confidence of approximately 95 %, typically using a coverage factor of k = 2. However, laboratories may report a coverage factor different than k = 2 to achieve the 95 % level of confidence. Units for the measurand and its uncertainty are to match. Exceptions to this occur when marketplace practice employs mixed units, such as when the artifact to be measured is labeled in non-si units and the uncertainty is given in SI units (Example: 5 lb weight with uncertainty given in mg). Note 3a: The uncertainty of a specific calibration by the laboratory may be greater than the uncertainty in the CMC due to the condition and behavior of the customer's device and specific circumstances of the calibration. The uncertainties quoted do not include possible effects on the calibrated device of transportation, long term stability, or intended use. Note 3b: As the CMC represents the best measurement results achievable under normal conditions, the accredited calibration laboratory shall not report smaller uncertainty of measurement than that given in a CMC for calibrations or measurements covered by that CMC. Note 3c: As described in Note 1, CMCs cover calibrations and measurements that are available to the laboratory s customers under normal conditions. However, the laboratory may have the capability to offer special tests, employing special conditions, which yield calibration or measurement results with lower uncertainties. Such special tests are not covered by the CMCs and are outside the laboratory s scope of accreditation. In this case, NVLAP requirements for the labeling, on calibration reports, of results outside the laboratory s scope of accreditation apply. These requirements are set out in Annex A.1.h. of NIST Handbook 150, Procedures and General Requirements. Note 4: Uncertainties associated with field service calibration may be greater as they incorporate on-site environmental contributions, transportation effects, or other factors that affect the measurements. (This note applies only if marked in the body of the scope.) Note 5: Values listed with percent (%) are percent of reading or generated value unless otherwise noted. Note 6: NVLAP accreditation is the formal recognition of specific calibration capabilities. Neither NVLAP nor NIST guarantee the accuracy of individual calibrations made by accredited laboratories. Page 6 of 6 NVLAP-02S (REV. 2011-08-16)