HORIZONTAL INCLINOMETER PROBE. User Manual

Similar documents
TILT METERS. User Manual

_ ANCHOR LOAD CELLS USER MANUAL

S200D DIGITAL MEMS INCLINOMETER SYSTEMS INCLINOMETERS & PENDULUMS

T-REX T-REX INCREMENTAL EXTENSOMETER SETTLEMENT GAUGES

S143 _ EASY-LOCK INCLINOMETER CASING INCLINOMETERS & PENDULUMS

S430 _ BH PROFILE INCLINOMETER INCLINOMETERS & PENDULUMS

S430 _ BH PROFILE INCLINOMETER INCLINOMETERS & PENDULUMS

Digitilt Inclinometer Probe

RST INSTRUMENTS LTD.

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

INSTALLATION AND MAINTENANCE MANUAL Rev. 12/2015 Deda Elementi. seat post. seat post

MOD. MASTER METER INSTALLATION OPERATION AND MAINTENANCE. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Fixed Ladder: A ladder that cannot be readily moved or carried because it is an integral part of a building or structure

SUSPENSION MODULE by

Installation Instructions. Y-Series Brushless Servo Motor

USER MANUAL RHF SERIES

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Instruction Manual. Model MEMS Inclinometer Probe

Sondex Settlement System

In-Place-Inclinometer Installation Manual

OPERATIONS MANUAL LEVER CHAIN HOIST

FIXED DEPTH INSERTION METER INSTRUCTIONS

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

1. Foreword. Content. 1. Foreword. Content. WESA-X operating manual. WESA-X operating manual

BlinkerBeam SL80 Controller User Guide

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0

Owners manual. Öhlins Superbike front fork FG 170

Note: Please read through the entire guide before attempting any kind of installation.

IDENTIFICATION KLR.5100 Bagels bagger Left/right: right SERIAL NUM:

CSA products for waste water. Anti water hammer combination air valve. Mod. SCF-RFP

Note: Please read through the entire guide before attempting any kind of installation.

RS4000 Setup. Before you install the RS4000 system, check to ensure that nothing was damaged or lost during shipping.

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

In-Place-Inclinometer Installation Manual

Remote Start Kit for GM Installation RS1/3/4/7 + ADS-DL Tip Sheet

Instruction Manual. Vibration Severity Meter VM12

User manual for. Exalto windshield wiper Type 223 BD 12/24 Volt

WS-9116U Wireless 433 MHz Temperature Station. Instruction Manual

Note: Please read through the entire guide before attempting any kind of installation.

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Installation Tips for your Remote Start system (for RS4LX>GMBP for GM vehicles)

HEADIGHT TESTER HD113

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

Installation Tips for your Remote Start/Keyless Entry (for Honda/Acura Vehicles) [EVO-ALL] v1.02 updated 9/13/2013

External wiper housing

Operator s ManualMOWERS

Index. Inclination IN910 INCLAB IN915 IN920 IN921 IN922 IN923 IN930 IN935 IN940 IN950 IN980 INTBS

Larson Systems Inc. V200, V750 and V1500 Digital Valve Spring Tester User Manual. Current for Software Version 6.9

Installation Tips for your Remote Start system (for Toyota Camry & Prius C, ) Crimestopper RS0+ EVO-ALL T3468 rev#1.

Assembly Instructions of Geeetech Aluminum Prusa I3

User Guide. Model Insulation Tester / Megohmmeter. Introduction

OLYMPIAN MODEL 740 Operation and Service Manual

User's Manual. Earth Ground Resistance Tester. Model Introduction

EL Beam Sensors Standard & SC Versions

I n s t r u c t i o n M a n u a l. Swiss Jib Crane

USE AND MAINTENANCE MANUAL

N4 Series Magnetic Encoder Module High Resolution Module

GeoFlex In-Place Inclinometer DGSI. All Rights Reserved.

Megohmmeter Test Probe

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

XR Conveyor Maintenance Guide

DIGITAL TORQUE GAUGE MODEL BTGE-G

AeroVironment Universal Solar Pump Controllers

Service information. How to avoid equipment failures with preventive maintenance measures. 1. General information 08/2017

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

AXD 530 MicroManometer

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

RADEX -N Composite Operating/Assembly instructions

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

Woody Brushcutter. 5 and 6 lateral models OPERATOR S & MAINTENANCE MANUAL

Water Level Meter + Temperature

TIP SHEET. Installation Tips for your RS IB-MUX / PKUMUX (D) + SPDT T1205 v1.2 4/3/14. 1 P a g e

TECHNICAL MANUAL MT064

Type AB with limitation of axial backlash

SERVICE MANUAL. Hollandia 300 Large

Servicing a Katadyn PUR40E

Monitoring of Shoring Pile Movement using the ShapeAccel Array Field

Instruction Manual. Magnetic Mixer MM UltraPure ESE01696-EN Original manual TD

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

HF Series Incremental Magnetic Encoder Decade Count High Resolution Kit

Trus-T-Lift 750 Limited Maintenance Manual. Copyright 2016

INSTRUCTION MANUAL Oil level with pointer indicator

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

C3600P AND C7200P OPERATION INSTALLATION AND SERVICE MANUAL PRECISION TON CONTAINER SCALES

Astor 20 Colony Counter User s Manual

(450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind)

Mod: KLD6-12/35XLAS-N

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation Tips for your Add-on Remote Start (for GM vehicles with INTSL Install 2) v3.2 Updated 11/12/2012

UNIVERSAL SOLAR SYSTEM (USS) USER MANUAL. For Millennium Low Power Gas Detectors or other continuous loads less than 0.

PRODUCT SERVICE MANUAL

A Member of the. Integrated Metering Technologies

KIT CONSISTS OF: FEATURES. S-Digit mini

Transcription:

HORIZONTAL INCLINOMETER PROBE User Manual

INDEX Introduction Pag. 4 Description Pag. 5 Taking measurements Pag. 6 Data processing Pag. 8 Maintenance Pag. 10 Troubleshooting Pag. 10 Maintenance service Pag. 11 Appendix 1 Pag. 12 Appendix 2 Pag. 13 Information contained herein are property of SISGEO S.r.l. This document is subject to change without notification and is subject to be returned upon request. No part of this User s Manual may be reproduced in any form without SISGEO s S.r.l. written permission. SISGEO S.r.l. Horizontal Inclinometer Probe_EN_00_12 Pag. 2 of 13

Notes on the use of product For a safe and efficient use of the instrument, please read carefully the following instructions before starting any operation. Any use of the instrument other then the one described in this manual shall be considered at user s full responsibility. The same applies for any unauthorized modifications. In addition to the hereby listed standards, the user must comply with the provisions of the current legislation on the matter of personal safety and health of persons in the workplace. SISGEO is not responsible for any trouble, breakdowns, accidents etc.. due to the lack of knowledge and/or confidence (or non-compliance with) with the requirements contained in this manual. Check that the instrument has not been damaged during the transport. Verify that the package includes all items as well as any requested optional accessories; if anything is missing, please promptly contact the manufacturer. The user must strictly follow all the operations described in this manual. Maintenance or repair of the instrument is allowed only to authorized operators. These operators must be physically and intellectually suitable. For information about instrument or order spare parts request, please always specify data written on the identification label. When replacing parts, always use ORIGINAL SPARE PARTS. The manufacturer reserves the right to make changes without prior notice for any technical or commercial requests. We ll try anyway to keep the manuals updated in order to reflect product s revisions/updates. Symbols This symbol will be used used to catch reader s attention on the manual: Pay special attention to the following instruction. Identification Instruments can be identified From a production lot number (written on the Compliance Certificate) From a serial number (s/n) engraved indelibly on the instrument From a label on the instrument From a label on the cable SISGEO S.r.l. Horizontal Inclinometer Probe_EN_00_12 Pag. 3 of 13

Introduction The horizontal inclinometer probes are used to measure settlements and vertical deformations. They are used mainly in foundations, embankments and tanks. Inclinometer probe is a part of a system which includes: Horizontal inclinometer probe; Inclinometer cable; Portable Datalogger for data management; Incli2 data management software Measurements are usually carried out moving the probe inside inclinometer casing (aluminum or ABS made). The casing follows the deformations of the material where it is installed. A pulley is required when one end of the casing is not accessible (open) in order to pull (move) the inclinometer probe inside the casing by means of a pulling steel wire. pully inclinometer probe inclinometer casing reel and inclinometer cable steel wire pulling steel wire portable datalogger inclinometer casing PVC pipe SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 4 of 13

Description The horizontal inclinometer probe consists of a cilinder stainless steel body with digitized uniaxial MEMS tilt sensor. Probe is equipped with: Two electrical connectors with O-Ring (1 and 2) at each ends; Two wheel assemblies 500mm apart, for guiding the probe through the grooves of the inclinometer casing. The inclinometer operating cable supplied on reel mounts at one end the probe mating connector. The cable has metal marks every 500mm. The first mark is 1m far from the middle of the probe wheel assemblies. Every 5m a colored reference tape identifies the distance/position (see Appendix 2). Yellow cable is suitable for both servo-accelerometer and MEMS digital probes. It is reinforced with a stainless steel shield in order to avoid torsions and elongations. Orange cable designed for the MEMS probe is lighter and easy to handle. It has a kevlar stress member in order to avoid elongation. wheel assemblies electric connector electrical connector cable connector inclonometer cable connector with O-Ring SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 5 of 13

Taking measurements The inclinometer reading consists in a survey, at regular steps, of the inclinometer casing tilt compared to the horizontal. The step is usually the same of the wheels assembly interaxis or a multiple. The first reading, called zero reading, is the reference reading compared to which all the displacements of the inclinometer casing will be calculated; the following readings are called exercise readings. The following drawing shows the convention: Reference wheels 1 2 A < 0 1 Reference wheels 4 2 Install the inclinometer casing with the groove 1 and 3 in vertical position compared to the supporting surface. 3 To carry out inclinometer measurements proceed as follows: Remove the probe from the carrying bag; Check the wheels assembly and the wheels functionality; Check the O-ring; Keep the probe in vertical position on the ground and connect the inclinometer cable to the connector 1 paying attention to fit the connector references. DON T TURN and DON T STRAIN the connectors in order to avoid any irreparable damages; Once the connectors are matched, screw manually the nut until is fully locked. If well connected, the tightness is guaranteed up to 2MPa; Connect the steel wire to the steel cap on the connector 2 ; Put the probe into the inclinometer casing with the reference wheels in the groove no. 1. Position the probe at the end of the casing using the steel wire; Connect the datalogger to the inclinometer cable with the supplied connector. Be careful to respect the connectors polarity; SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 6 of 13

Switch-on the datalogger and wait for 10-15 minutes until the temperature stabilization; Pull the probe until the first available mark is at the border of the inclinometer casing. Place very carefully the marks since, in order to have good results, their position must never change. Wait until the value stabilization, identified as A1, and record this value; Pull the probe, placing the next mark at the reference point according to the step set; Proceed in this way for the whole length of the casing; Once ended, pull out the probe from the casing and disconnect the moving wire; Disconnect the inclinometer cable from the connector 1 and connect it to the connector 2 ; Connect the steel wire to the steel cap and screw it on the connector 1 ; Put the probe into the inclinometer casing with reference wheels in the groove no. 1 and position it at the end of the casing using the steel wire. Proceed as already explained above. In this case the values will be identified as A3. Once ended the reading, disconnect the datalogger, unscrew the nut and disconnect the probe from the inclinometer cable; Check the connectors (probe and cable): be sure that there is no humidity inside; Screw the protection caps; Clean and dry the probe carefully; Put the probe in its carrying casing; Rewind carefully the inclinometer cable on the reel, avoiding any torsion. Advices: Use always the same inclinometer system (probe-datalogger-cable) to survey the casing. Pay attention to the reference points (marks). Wait until the inclinometer system temperature is stable: it could be useful, in this case, to check the values shown by the datalogger. When you move from a quote to the next one, record the data only when the values are settled. In case of wrong positioning, put the probe at the previous position. Avoid pulls and excessive speed during the probe recovery. SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 7 of 13

Data processing The data processing is usually made using a dedicated software (i.e. FIELD-SISGEO INCLI2); see the reference manual for further details. Herewith below are clarified the basic notions for data processing. SISGEO inclinometer probes have a constant k of 20000. Different k shall be required at order placing. The values (digits) displayed from SISGEO dataloggers are: digits = (sinα) x (k) Example: Ch. A: 698(digits) α= arcsin (698/20000) = 2 To calculate the casing inclination at each quote proceed with the following formula: P D i where D i = P x sinα D i = casing displacements at the generic quote P = measurement step sinα = casing inclination angle at the generic quote The inclination value for each measuring step is: (A1-A3)/2 Example: At i quote we have the following values: A1 = 480 A3 = -506 P = 500mm The inclination at the i quote is 12.325mm α To calculate the global displacement D of the casing proceed with the following formula: D= n 1 D i SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 8 of 13

The global displacement calculation must be done considering that one of the end of the casing is not subject to movements or considering the absolute displacements of the casing taken, for example, by means of topographic measurements. Hints on checksum The checksum is the algebraic half-sum of the measurements obtained on the matched grooves 1-3. It s like an electric and/or mechanic offset of the inclinometer probe and, as shown in the following example, does not affect the final result: it is a sign of the well-functioning of the inclinometer system and its regular check is important. The checksum can be affected by deposits in the grooves, by inclinometer casing dents or ovalization, from the wheel positioning near the couplings and also by the differences between different models of Dataloggers. Checksum value can change in time but, if the variation is not sudden, usually there is nothing to worry and is not necessary to contact SISGEO for technical assistance. Anyway SISGEO suggests a check of the inclinometer system in case of checksum values higher than 25. Example: inclination 2, theoretical value =698 (digits), A1= 713, A3=-683 checksum= (A1+A3)/2= 15 A1-checksum= 713-15=698; A3-checksum= -698-15=-698 Anyway, the value obtained by the matching measures at the end of the processing is: Am= (A1-A3)/2= [713-(-683)]/2 = 698 SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 9 of 13

Maintainance Probe maintainance The inclinometer probe is a precision instrument and has to be handled carefully, avoiding accidental shocks both during the transport and the use. Use the carrying case during the transport and the storage. Clean the probe with water and lubricate the wheels and the springs without using grease. Clean up the possible mud and dirt on the springs. Take away the protection cap from the probe and inclinometer cable, clean and eventually dry the connector and the thread. Clean the connectors with cotton wads and alcohol. Don t use solvents or other products that can cause a damage. The probe and the accessories must be stored in a dry place. To avoid condensation we advise to store probe and cable without protection caps; they have to be put back on in case the instrument has to be moved. Clean the inclinometer cable with water and dry it. Be careful during the unwind and rewind of the cable in order to avoid stretching and rolling that can damage the cable. When they are not in use, always protect the connectors with their caps. To keep the system in perfect conditions we advise a maintenance check in our laboratories once a year. Troubleshooting Problem Possible cause Solution Wrong measures Instable measures Checksum values unsteady Wrong choice of the reference Low battery voltage Low insulation Damp in the connector One or more electric wires are disconnected Excessive movement of the wheels Wheels out of grooves Dirty casing Use the correct reference groove Check the voltage on the display and put in charge (see the manual) Measure the insulation between the pins of the probe connector and the steel body. If it s less than 50 MΩ,send it back to SISGEO Assistance Dry it. Verify the integrity of the "O-ring" Verify wiring in the Appendix 1. Send back to SISGEO Assistance if any disconnection is found. Verify wheels movement. If necessary send back to SISGEO Assistance. Verify and insert correctly the wheels in the grooves. Move the probe more slowly. Clean the casing SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 10 of 13

Maintainance service After-sales assistance on SISGEO products for calibrations, maintenance and repairs is performed by SISGEO service department. The authorization of shipment shall be activated by RMA Return Manufacturer Authorization". Fill in the RMA module clicking on: http://www.sisgeo.com/en/assistance/repairs/ Send back the instrument/equipment with the complete accessories, using suitable packaging or, even better, the original ones. The shipping costs shall be covered by the sender. Please send the goods to the following address with suitable delivery document: SISGEO S.r.l. Via F.Serpero, 4/F1 20060 MASATE (MI) On the delivery note is mandatory to indicate the received RMA code. Technical assistance e-mail: assistance@sisgeo.com SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 11 of 13

Appendix 1 CONNECTION TABLE Probe Functions MEMS DIGITAL PROBE Inclinometer cable (orange) Conn. 6 pins Color Conn. 7 pins Female Male Panel A +Vcc A RED A B -Vcc B BLACK C C D N.C. N.C. E RS485 A E WHITE E F RS485 B F GREEN F Universal inclinometer cable (yellow) Conn. 6 pins Female Color Conn. 7 pins Male Panel A ORANGE A B GREY C C BLACK B D YELLOW D E BLUE E F GREEN F SHIELD G FLYING CABLE MOD. ECAV07V2 Female Connector (at the cable pulley) Male Connector (to Datalogger) A B C D E F G A B C D E F G SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 12 of 13

Appendice 2 REFERENCE MARKS METERS GREEN BLACK RED WHITE 5 1 10 1 15 1 1 20 1 25 1 1 30 1 1 35 1 1 1 40 2 45 1 2 50 1 55 1 1 60 1 1 65 1 1 1 70 1 1 75 1 1 1 80 1 1 1 85 1 1 1 1 90 2 1 95 1 2 1 100 2 105 1 2 110 1 2 115 1 1 2 120 1 2 125 1 1 2 130 1 1 2 135 1 1 1 2 140 2 2 145 1 2 2 150 3 155 1 3 160 1 3 165 1 1 3 170 1 3 175 1 1 3 180 1 1 3 185 1 1 1 3 190 2 3 195 1 2 3 200 4 SISGEO S.r.l. Horizontal inclinometer probe_ EN_ 00_ 12 Page 13 of 13