TOWER BTG CHILLED AND HEATED RF BTG RF6 BTG RF9 BTG RF12 BTG RF15 BTG RF18 Heated double glazed glass top, sides and front Heated rear sub frame Argon filled rear doors Sliding rear doors Deck forced refrigeration Three adjustable shelves Ticket strips on shelves and base Undershelf and canopy LED lights Integral condensor Sliding front doors - optional 1380 178 719 80 153 745 505 560 708 25 600 900 1200 1500 1800 HT BTG HT6 BTG HT9 BTG HT12 BTG HT15 Deck forced heating SIngle glazed Sliding rear doors Four adjustable shelves Ticket strips on shelves and base Undershelf and canopy LED lights Sliding front doors - optional 1380 178 719 80 745 505 25 600 900 1200 1500 1800 560 Page 1
TOWER BTG AMBIENT AND COMBO CHILLED AB BTG AB6 BTG AB9 BTG AB12 BTG AB15 SIngle glazed Sliding rear doors Four adjustable shelves Ticket strips on shelves and base Undershelf and canopy LED lights Sliding front doors - optional Ambient converted from heated Air removal fan installed in ceiling 1380 178 719 80 745 505 25 600 900 1200 1500 1800 560 745 865 635 BTG RA10 BTG RA15 800 504 RA Combo unit chilled and ambient Heated front and top glass Soild front only Sliding rear doors - chilled section Hinged rear door - ambient section Ticket strips on shelves and base Undershelf and canopy LED lights 1380 178 398 710 555 1500 680 320 1000 Page 2
TOWER BTG AND TTG OPEN FRONT CHILLED 745 OR BTG OR6 BTG OR9 BTG OR12 1380h Open front 2 adjustable shelves Stainless steel hinged rear doors Deck forced refrigeration Double glazed glass ends Two adjustable glass shelves Ticket strips on shelves and base Undershelf and canopy LED lights Pull down night blind 1380 805 178 397 346 450 710 120 600 900 1200 745 OR TTG OR6 TTG OR9 TTG OR12 1500h Open front 3 adjustable shelves Stainless steel hinged rear doors Deck forced refrigeration Double glazed glass ends Two adjustable glass shelves Ticket strips on shelves and base Undershelf and canopy LED lights Pull down night blind 1500 925 178 397 394 434 528 710 205 206 195 120 600 900 1200 Page 3
TOWER BTG AND TTG OPEN FRONT HEATED 745 OH BTG OH6 BTG OH9 1380h 135 135 135 346 426 506 Open front heated 3 adjustable shelves Individual shelf heating Deck forced heating Single glazed Ticket strips on shelves and base Undershelf and canopy LED lights 1380 400 168 595 710 555 600 900 745 OH TTG OH6 TTG OH9 1500h Open front heated 4 adjustable shelves Individual shelf heating Deck forced heating Single glazed Ticket strips on shelves and base Undershelf and canopy LED lights 1500 400 595 555 600 900 710 Page 4
TOWER BTG SPECIFICATIONS Cabinet Dimensions & Specifications Model CAbinet Shelving operating temp Length [mm] Depth [mm] Height [mm] POWER CORD LENGTH SHELF BASE TRAY FREQUENCY refrigerant operating current connection voltage Packed for shipping deg c W X D W X D Length [mm] Depth [mm] Height [mm] Weight BTGRF6 600 1380 3 + base 3-5 2200mm 495x445 540 x510 50/60 Hz 134A 4.2 amp 10amp 3 pin plug 220-240V 700 830 1550 175 BTGRF9 900 1380 3 + base 3-5 2200mm 790x445 840 x510 50/60 Hz 134A 4.5 AMP 10 amp 3 pin plug 220-240V 1000 830 1550 224 BTGRF12 1200 1380 3 + base 3-5 2200mm 1095x445 1140 x 510 50/60 Hz 134A 5.0 amp 10 amp 3 pin plug 220-240V 1300 830 1550 273 BTGRF15 1500 1380 3 + base 3-5 2200mm 1395x445 1440 x 510 50/60 Hz 134A 6.0 AMP 10 amp 3 pin plug 220-240V 1600 830 1550 329 BTGRF18 1800 1380 3 x 2 + base 3-5 2200mm 827x445 1740 x 510 50/60 Hz 134A AMP 10 amp 3 pin plug 220-240V 1900 830 1550 BTGHT6 600 1380 4 + base 75-85 2200mm 495x445 540 x 510 50/60 Hz N/A 4.1 AMP 10 amp 3 pin plug 220-240V 700 830 1550 118 BTGHT9 900 1380 4 + BASE 75-85 2200mm 795x445 840 x 510 50/60 Hz N/A 6.2 AMP 10 amp 3 pin plug 220-240V 1000 830 1550 150 BTGHT12 1200 1380 4 + BASE 75-85 2200mm 1095x445 1140 x 510 50/60 Hz N/A 8.3 AMP 1o amp 3 pin plug 220-240V 1300 830 1550 182 BTGHT15 1500 1380 4 + BASE 75-85 2200mm 1395x445 1440 x 510 50/60 Hz N/A 10.4 AMP 15 amp 3 pin plug 220-240V 1600 830 1550 214 BTGAB6 600 1380 4 + BASE N/A 2200mm 495x445 540 x 510 50/60 Hz N/A 0.2 AMP 10 amp 3 pin plug 220-240V 700 830 1550 133 BTGAB9 900 1380 4 + BASE N/A 2200mm 795x445 840 x 510 50/60 Hz N/A 0.3 AMP 10 amp 3 pin plug 220-240V 1000 830 1550 133 BTGAB12 1200 1380 4 + BASE N/A 2200mm 1095x445 1140 x 510 50/60 Hz N/;A 0.4 AMP 10 amp 3 pin plug 220-240V 1300 830 1550 157 BTGAB15 1500 1380 4 + BASE N/A 2200mm 1395x445 1440 x 510 50/60 Hz N/A 0.5 AMP 10 amp 3 pin plug 220-240V 1600 830 1550 158 Page 5
TOWER BTG SPECIFICATIONS Cabinet Dimensions & Specifications MODEL CABINET SHELVING SHELVES SIZE FREQUENCY REFRIGERANT OPERATING CURRENT CONNECTION VOLTAGE PACKED FOR SHIPPING LENGTH (MM) DEPTH (MM) HEIGTH (MM) TOP 2ND 3RD 4TH BASE(WxD) 50/60 Hz LENGTH (MM) DEPTH (MM) HEIGTH (MM) WEIGHT (KG) BTGOR6 600 1380 2+BASE 490x290 490x380 NA NA 545x515 50/60 Hz 134a 3.3AMP 10AMP 3 PIN PLUG 220~240V 700 830 1550 175 BTGOR9 900 1380 2+BASE 790x290 790x380 NA NA 845x515 50/60 Hz 134a 3.7AMP 10AMP 3 PIN PLUG 220~240V 1000 830 1550 224 BTGOR12 1200 1380 2+BASE 1090x290 1090x380 NA NA 1145x515 50/60 Hz 134a 5.4AMP 10AMP 3 PIN PLUG 220~240V 1300 830 1550 273 BTGOH6 600 1380 3+BASE 490x255 490x335 490x415 NA 548x595 50/60 Hz NA 8.1AMP 10AMP 3 PIN PLUG 220~240V 700 830 1550 119 BTGOH9 900 1380 3+BASE 790x255 790x335 790x415 NA 848x595 50/60 Hz NA 12.6AMP 15AMP 3 PIN PLUG 220~240V 1000 830 1550 153 TTGOR6 600 1500 3+BASE 490x295 790x325 790x415 NA 545x515 50/60 Hz 134a 3.3AMP 10AMP 3 PIN PLUG 220~240V 700 830 1670 192 TTGOR9 900 1500 3+BASE 790x295 790x325 790x415 NA 845x515 50/60 Hz 134a 3.7AMP 10AMP 3 PIN PLUG 220~240V 1000 830 1670 246 TTGOR12 1200 1500 3+BASE 1090x295 1090x325 1090x415 NA 1145x515 50/60 Hz 134a 5.4AMP 10AMP 3 PIN PLUG 220~240V 1300 830 1670 300 TTGOH6 600 1500 4+BASE 490x255 490x335 490x415 490x415 548x595 50/60 Hz NA 9.3AMP 15AMP 3 PIN PLUG 220~240V 700 830 1670 132 TTGOH9 900 1500 4+BASE 790x255 790x335 790x415 790x415 848x595 50/60 Hz NA 14.6AMP 20AMP LEAD only 220~240V 1000 830 1670 170 Page 6
TOWER BTGRF6 Page 7
TOWER BTGRF9 1380 Page 8
TOWER BTGRF12 1380 Page 9
TOWER BTGRF15 1380 Page 10
TOWER BTGRF18 A 827 38 827 Heated Solid Front Glass x6 Shelves 745 x6 LED 510 Heated End Glass 710 503 1705 48 1376 25 800 178 1800 (398) A 1802 Page 11
TOWER BTGHT6 1380 Page 12
TOWER BTGHT9 1380 Page 13
TOWER BTGHT12 1380 Page 14
TOWER BTGHT15 Page 15
TOWER BTGOR6 602 38 370 979 150 57 48 48 A 745.5 117 394.2 1376 528.1 684.5 25 B 19.7 177.6 596.8 A A-A 549 Page 16
TOWER BTGOR9 805 Page 17
TOWER BTGOR12 805 Page 18
129 129 136 TOWER BTGOH6 498 348 52 52 602 A 746 351 397 575 1372 150 25 158 717 82 47 20 Page 19 597 A A-A 549 708
TOWER BTGOH9 A 745 346 135 100 506 426 348.5 135 555 400 800 1380 135 168 1380 595 902 48 A 710 797.5 902 Page 20
TOWER TTGOR6 Page 21
TOWER TTGOR9 Page 22
TOWER TTGOR12 1200 746 38 117 120 370 1103 B 1500 25 199 206 205 57 48 48 500 500 394 434 528 808 178 1197 A-A 709 Page 23
TOWER TTGOH6 498 349 52 602 A 46 746 351 150 1496 25 144 116 116 116 123 841 82 20 397 575 A A-A Page 24
116 TOWER TTGOH9 798 348 52 52 902 A 746 351 397 575 150 25 144 1496 841 124 82 46 116 116 20 Page 25 897 A A-A 549 708
TOWER RA10 Page 26
TOWER RA15 1380 Page 27
DRAINAGE - OPTIONAL To Waste The condensate waste pipe may be plumbed directly to the building drainage system Condensate drain pipe To Waste Water Drain Page 28
BTG REAR VENTILATION Rear Ventilation Rear intake and extract ventilation system Side mounted compressor Front can be fully covered with custom panel joinery to suit environment Separation To Wall A separation gap of 150mm must be allow to provide adequate ventilation if unit is being placed hard up against a wall Exhaust air extract through left rear internally ducted to environment Ambient air intake through right rear internally ducted through condenser face Page 29
BTG OPTIONAL FRONT VENTING Standard Configuration as shipped Back to back with front venting Standard rear grill Standard front baffle Air flow intake from left rear side and exhaust through right rear side Optional Configuration - Front to Front Against a wall with front venting Rear grill removed and replaced with solid panel Front baffle panel removed and discarded Front grill detached and re-attached after configuration change Page 30 Air flow intake from left front side and exhaust through right front side
PLACEMENT GUIDES NO AIR FLOW CLEAR FLOW AIR FLOW BLOCKED too much chilled air around coil can create excessive ice build up CORRECT AIR FLOW INCORRECT AIR FLOW Mechanical air flows, such as diffusers and fans can disturb the air curtain on open fronted units causing failure Heat from other equipment and natural conditions, such as direct sunlight straight on units, can cause cooling to fail and overload compressor Blocked air flow will retard operation on both HOT and COLD units Ensure trays or plates are not blocking air flow at rear Natural disruptive air flow such as cross winds can disturb the air curtain on open fronted units causing cooling to fail Locations to avoid : - Close to shop front exterior - In a high wind - In an outsdie location - Near any source producing excessive heat - In direct sunlight - Service units more frequently in dusty or polluted areas Page 31
PLACED IN BENCH DETAIL Dropped Into Benchtop Unit is dropped in to hole cut in bench top and supported by font and rear flange of unit. MODEL CUT OUT SIZE Support Support BTG6 615 X 720 BTG9 915 X 720 BTG12 1215 X 720 BTG15 1515 X 720 Placed Into Benchtop from rear Parts removed Castors, front and side panels removed. Rear panels / grill remain for personnel safety. Unit is slid into custom built frame from rear and supported by the sides of the unit base frame. L shaped supports shown in red in this example. Support Page 32
COPS CLIP ON PANEL SYSTEM Easy install option to eliminate a nib wall Simply roll in and clip on Clip on panels offered in routed 18mm MDF Melteca finish in three colour options 600/900/1200/100 lengths options with end panels Affinity Maple Bliss Shitake Burnished Wood Page 33
COPS CLIP ON PANEL SYSTEM Clips screw fixed to panel Bottom edge sits flush with bottom of panel end panels Double sided velcro Integrated Clip System - Bracket fixing to joinery panels Page 34
SELF SERVICE SYSTEM SELF SERVICE SYSTEM Each unit is self contained Roll-in - Roll-out Install in minutes No on site joinery work required Ease of cleaning and servicing Mobile and flexible Easy to upgrade front panel design Custom branding strip Rear service or against wall All parts as optional component kits Ideal solution for temporary events Optional bottom shelf kit for chilled units Ensure chilled units are kept well ventilated Vent required through front panel Optional bottom meltica shelf kit - BY OTHERS Optional rear loading shelf kit 200mm deep Optional bottom meltica shelf kit - BY OTHERS Page 35
180 mm BTG ACCESSORIES Top Mounted Controller Panel For against wall installations Sold individually Base Tray - Heated Units Stainless Steel For heated units Sold in pairs Price Tabs Stainless Steel Write on with marker or adhesive tape Measure 60mm x 30mm Sold in packs of 20 Tong Holder Stainless Steel Drop into counter tray race Sold individually 100 mm 190 mm 80 mm Bag Holder 220 mm 105 mm Front and Rear Work Shelves Stainless Steel Sold individually 600-900 mm - 1200 mm - 1500 mm 300 mm Front Castor Extension Kit Increases cabinet height to 1660mm 75 mm 190 mm 600-900 mm - 1200 mm - 1500 mm 250 mm Rear Set of four, uses existing castors, includes fixing bolts and washers 280 mm 370 mm Humidity Dish Stainless Steel Perforated lid is removable 90 mm Page 36
BTG ACCESSORIES OR Units - Rear door locking plate For against wall or back to back installations used to prevent rear hinged doors from being opened. Rear door handles are removed and discarded and plate is screwed in place. OR OH Units - Unit Spacer For OH and OR units. Provides a 100mm space between open fronted heated and chilled units to prevent the transfer of hot and cold air which can reduce proformance. Attached to the bottom side of one unit using exisitng screws on side panel. screws are removed and spacer is screwed in place. 100mm Page 37
MERCHANDISE TRAY Merchandise Tray Clip on stainless steel tray for all free standing units Attached to front of unit Built in ticket strip Angled base for maximum display Page 38
Charcuterie RACK 190mm 190mm Charcuterie Rack Stainless steel heavy duty shelf brackets 3 x 20 dia Stanless steel tubes Replaces existing shelves to allow hanging of cured meats, cheeses etc. Available in 900 and 1200 lengths only Maximum of 50kgs Hooks not included Weight to be spread evenly over front, middle and rear rods Page 39
MIRROR FILM Blocks work areas behind units Mirror film adhered to inside of rear door glass Mirror film adhered to inside of rear door glass Add depth to your displays FREE STANDING UNITS Applied to the inside glass rear doors Suitable for heated and chilled units BENCHTOP UNITS Page 40
BTG SHELVING Glass Shelf Options Standard wire racks are removed and replaced with 6mm toughened glass panes Pie Trays Stainless Steel Construction Stainless Steel glass shelf support bracket PIE TRAYS MODEL No. OF SHELF TRAYS WIDTH MM DEPTH MM PER SHELF TOTAL BTGHT6 4 per SHELF 120 445 4 16 BTGHT9 6 PER SHELF 130 445 6 24 BTGHT12 9 PER SHELF 120 445 9 36 Model GLASS DEPTH MM width MM PER SHELF PANES SHELVES TOTAL PANES BTGRF6 6MM TOUGHENED - POLISHED EDGES 430 240 2 3 6 BTGRF9 6MM TOUGHENED - POLISHED EDGES 430 390 2 3 6 BTGRF12 6mm TOUGHENED - POLISHED EDGES 430 540 2 3 6 BTGRF15 6mm TOUGHENED - POLISHED EDGES 430 690 2 3 8 BTGHT6 6MM TOUGHENED - POLISHED EDGES 430 240 2 4 8 BTGHT9 6MM T(OUGHENED - POLISHED EDGES 430 690 2 4 8 BTGHT12 6MM TOUGHENED - POLISHED EDGES 430 540 2 4 8 BTGHT15 6MM TOUGHENED - POLISHED EDGES 430 690 2 4 8 Page 41
GASTRO PAN RACK 1 Rack 1x 1/1 pan One rack with full size pan 1 Rack 2 x 1/2 pan One rack 2 x half pans 1 Rack 5 x 1/9 pans 3 x 16 pans One rack varrious size pans with divider 1 Rack 1 Rack GASTRONORM PAN SYSTEM One rack with drop in divider MODEL PAN DEPTH RACKS NO. BTG 6 65MM 1X 1/1 BTG 9 65MM 2 X 1/1 BTG 12 65MM 3 X 1/1 BTG 15 65MM 4 X 1/1 Page 42
COLOUR WRAP OPTIONS COUNTER TOP MODEL - CURVED OR SQUARE all exterior visible areas covered DROP IN COUNTER TOP MODEL - CURVED OR SQUARE - all exterior top visible areas covered FREE STANDING - CURVED OR SQUARE all exterior visible areas covered FREE STANDING BEHIND NIB WALL - CURVED OR SQUARE all exterior top visible areas covered 2mm gap left around rear frame Rear of units cut around serial number plate, exhaust fan and controller WRAP TRIMMINIG Page 43